Incorporation of polar functional moieties into polyethylene (PE) film has been achieved by graft copolymerization of polar monomers such as methacrylic acid (MAAc) and acrylamide (AAm) on to PE film, preirradiated with ${\gamma}$-rays from $^{60}Co$ source, using benzoyl peroxide (BPO) as initiator in aqueous medium. Percentage of grafting of MAAc and AAm was determined as a function of irradiation dose, monomer and initiator concentration, temperature, reaction time and amount of water. Maximum percentage of grafting of MAAc (1453%) and AAm (21.28%) was obtained at [MAAc] = $235.3{\times}10^{-2}$ mol/L, [AAm] = $23.4{\times}10^{-2}$ mol/L, [BPO] = $5.5{\times}10^{-2}$ mol/L and $16.5{\times}10^{-2}$ mol/L at $80^{\circ}C$, $90^{\circ}C$ in 180 min and 90 min respectively. The grafted PE films were characterized by FTIR, Thermogravimetric analysis (TGA) Scanning Electron Micrography (SEM) and X-ray diffraction methods. Some selective properties of grafted films such as swelling behavior, ion and metal uptake have been carried out. The biodegradation studies of the grafted PE films have also been investigated. The grafted films developed superior swelling behavior with maximum swelling (480%) in water as compared to pristine PE (13.55%), better thermal stability and ion and metal uptake studies showed promising results that can be effectively used for desalination of brackish water and separation of metals from the industrial effluents.
The radiation-induced graft polymerization of methacrlic acid and methyl methacrylate onto a polyester fabric was investigated with ${\gamma}$-ray as the radiation source, and the rate of grafting was examined. When acrylic acid, methacrylic acid, and methyl methacrylate were grafted onto a polyester fabric, grafting efficiency was depened upon the dielectric constant of the solvent in the monomer mixture. The yield of the graft polymerization was related to the total dose, the concentration of the monomer, and the concentration of the swelling agent. The melting point and the glass transition temperature of MA and MMA grafted copolymers were analysed by means of DTA. Physical properties, such as the moisture regain, the antistatic property, and the wicking time were measured.
Potato and garlic irradiated with gamma ray and electron beam at sprout-inhibition doses, 0.15 and 0.30 kGy were subjected to the detection whether they are irradiated or not by measuring thermoluminescence(TL) for the minerals adhering to the samples. Minerals extracted from the samples showed a high correlation coefficients between absorbed doses and corresponding TL responses. Nonirradiated samples, however, did not exhibit characteristic TL glowcurves. Major glowcurve peaks were observed at 200 to $260^{\circ}C$ in all irradiated samples. TL intensity was proportional to irradiated doses, but it varied with the samples tested even at the same dose. It can be concluded from the results that detection of irradiated potato and garlic is possible by measuring TL for extracted minerals from the unknown samples.
본 논문에서는 핵폭발과 같은 고준위방사선환경에서의 전자부품소자의 피해평가분석을 통하여 군용전자장비의 내방사선화를 하기 위한 기반기술의 확립을 위한 연구의 일환으로 74AC04(Inverter) IC에 대한 고준위감마선조사시험을 통하여 Co-60 Gamma-ray 선원을 사용하여 총 400Krad[si] 누적 선량에 대한 74AC04 소자의 동작특성 및 전기적 파라메터의 변화분석을 진행하였다. 시험평가 방법 및 절차는 MIL-STD-883G 1019.7[1] 및 ESA/SCC Basic Specification No.22900[2] 절차를 기준으로 하여 동일 lot에 대한 5개의 샘플을 이용하여 동작특성에 영향을 미치는 주요한 전기 적파라메터인 정지소비전류, 입력누설전류, VIL(Maximum Low Level Input Voltage)에 대한 변화추이를 분석하였다. 이번 조사시험을 통하여 입력게이트에서의 누적선량에 따른 TID(Total Ionizing Dose) 효과로 인한 VIL의 감소 추이를 확인 할 수 있었으며 총 누적선량 160Krad 이상에서의 VIL은 허용기준치이하로 감소하였고 정지소비전류의 경우 누적선량에 따른 점진적 증가 현상과 200Krad부근에서의 설계스펙허용치를 초과하는 결과를 확인하였다.
In the first study, the Radon emanation and radiological hazards associated with radionuclides in soil samples, collected from 9 various date palm farms located in 3 different districts in Saudi Arabia were determined through a high purity Germanium (HPGe) gamma-ray spectrometer. The estimated average values of Radon emanation coefficient and Radon mass exhalation rate for soil samples were 0.535 ± 0.016 and 50.063 ± 7.901 mBqkg-1h-1, respectively. The annual effective dose of radionuclides in all sampling locations was found to be lower than UNSCEAR's recommended level of 0.07 mSvy-1 for soil in an outdoor environment. In the secondary study, gross α and gross β activities in soil and date palm pits samples were measured by a low background α/β counting system. Average values of gross α and gross β activities in soil and date palm pits samples were 5.761 ± 0.360 Bqkg-1, 38.219 ± 8.619 Bqkg-1 and 0.556 ± 0.142 Bqkg-1, 24.266 ± 1.711 Bqkg-1, respectively.
The peripheral neutrophil recovery test was conducted to determine the efficacy of CJ-50001, a drug developed in Cheil Jedang R&D center as a recombinant granulocyte-colony stimulating factor (rG-CSF). Grasin was used as control drug. CJ-50001 and Gratin were subcutaneously administered to ${\gamma}$-ray irradiated mice for 21 days at a dose of 10$\mu$g/kg after bone marrow transplantation and the recovery of neutrophil number was examined on the days of 9, 13, 17, and 21 after the drug administration. It was observed that the peripheral neutrophil number of the vehicle control group was recovered to the normal level on the day of 13 after the transplantation whereas the group administered with CJ-50001 and Grasin respectively, showed the normal level of peripheral neutrophil number on 9th day after the bone marrow transplantation. The number of peripheral neutrophils reached the highest level on the 21 st day of drug administration, and was recovered to the normal level on the 4th day after ceasing of the drug administration (on the 25th day of the transplantation). Thus, it was presumed that CJ-50001 showed efficacy similar to Grasin on the peripheral neutrophil recovery after bone marrow transplantation.
Irradiation is widely used for the treatment of malignant diseases, and possibly cause the osteoporosis. The densitometry and bone scintigraphy are valuable when used to monitor the patients longitudinally to access the progression of osteoporosis and risk of osteoradionecrosis. To evaluate the osteoporosis after irradiation of Cobalt-60 gamma ray on the lumbar spines of New Zealand white rabbits, bone densitometry by dual photon absorptiometry and bone scintigraphy were performed weekly. The decrease of bone density began at the first week after irradiation, and were in the nadir at 4-6th week. The osteoblastic activity measured by bone scintigraphy decreased in the first week, and was in the nadir at 4-6th week. The severity of these changes were related to the radiation dose. In conclusion, the osteoporosis before the presentation of the osteoradionecrosis can be diagnosed early with the dual photon absorptionmetry and bone scintigraphy.
In order to investigate the properties of radiation resistance together with dielectric, and mechanical relaxation behaviors of polyvinylcholoride exposed to several different doses under the .gamma.-ray of Co$^{60}$ source, several observations were carried out on the exposed specimens propared by mixing dibutyl-tin-dilaulate and dibutyl-tin-dimaleate as stabilizer with or without adding dioctyl-phthalate as plasticizer. Conclusions obtained from the study are as follows: The origin of the absorption band at 1,540-1,640$cm^{-1}$ / on I.R. spectrum seems to be RCOO- ion originated from ionization of the stabilizer, and this peak can be useful as a measure of radiation resistance on polyvinylchloride. Addition of increasing plasticizer to polyvinylchloride exhibits increasing radiation resistance and the reason for this result may be attributed to aromatic resonance absorption of radiation energy by diotylphthalate. On dose dependent dielectric characteristics, nonplastized specimen shows a peak at about 10 Mrad and that this peak disappears on the plastification of specimens. Those phenomena may be explainable in considering the statistical distribution of scissored chain molecular segments as well as the plastification process of plasticizer to polyvinylchloride chain molecules.
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
2001.05c
/
pp.43-46
/
2001
Polymers are widely used as insulating materials at various part of power industry. However, electrical properties of these polymers are easily degraded with their working environments, especially radiation areas. In this research, radiation degradation of low density polyethylene (LDPE) used as cable insulation was evaluated with thermoluminescence characteristics. LDPE was irradiated with gamma ray up to 1000 kGy at a dose rate of 5 kGy/hr in the presence of air at room temperature. Each of the irradiated samples were carried out thermoluminescence analysis as a function of temperature. Interrelationships between thermoluminescence and dielectric characteristics and volume resistivity are investigated as well. The results of thermoluminescence analysis showed that those would be significant factors for evaluation of radiation degradation.
Attempts to isolate the naturally occurring ultra-violet resistant bacteria from environmental sources were made. The isolates, designated No.29, 100, and 107, among numbers of bacterial isolates revealed a remarkable resistance to UV ray, whose degree of resistance in dose/response kinetics was comparable to that of an endospore-former, Bacillus subtilis. In a range of 100-300 $Jm^{-2}$/min of UV irradiation, the isolates exhibited 500-1000 fold resistance compated with E. coli. The isolated appeared to possiss cell-bound pigment of organge or crimson-red. The isolate 29 is spherical in pairs or tetrads, whereas the isolates 100 and 107 are rod. All are Gram-gositive bacteria and seemed to be non-endospore-bearer. A number of biochemical studies pursued on the isolates suggested that they are quite different to each other. Electron microscopic examination and the physiological characters of the isolate 29 suggested that this UV resistant spherical bacterium might be one species of Deinococcus, probably Deinococus radiophilus. Since there is no documents on UV resistant, Gram-positive, non-sporeformer bacillus so far, the isolates 100 and 107 might be turned out as new kinds of UV resistant bacteria occurring in nature by further investigation.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.