• 제목/요약/키워드: gain coefficient

검색결과 400건 처리시간 0.031초

광대역의 우수한 이득평탄도를 갖는 V-밴드 전력증폭기 MMIC (V-Band Power Amplifier MMIC with Excellent Gain-Flatness)

  • 장우진;지홍구;임종원;안호균;김해천;오승엽
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.623-624
    • /
    • 2006
  • In this paper, we introduce the design and fabrication of V-band power amplifier MMIC with excellent gain-flatness for IEEE 802.15.3c WPAN system. The V-band power amplifier was designed using ETRI' $0.12{\mu}m$ PHEMT process. The PHEMT shows a peak transconductance ($G_{m,peak}$) of 500 mS/mm, a threshold voltage of -1.2 V, and a drain saturation current of 49 mA for 2 fingers and $100{\mu}m$ total gate width (2f100) at $V_{ds}$=2 V. The RF characteristics of the PHEMT show a cutoff frequency, $f_T$, of 97 GHz, and a maximum oscillation frequency, $f_{max}$, of 166 GHz. The gains of the each stages of the amplifier were modified to have broadband characteristics of input/output matching for first and fourth stages and get more gains of edge regions of operating frequency range for second and third stages in order to make the gain-flatness of the amplifier excellently for wide band. The performances of the fabricated 60 GHz power amplifier MMIC are operating frequency of $56.25{\sim}62.25\;GHz$, bandwidth of 6 GHz, small signal gain ($S_{21}$) of $16.5{\sim}17.2\;dB$, gain flatness of 0.7 dB, an input reflection coefficient ($S_{11}$) of $-16{\sim}-9\;dB$, output reflection coefficient ($S_{22}$) of $-16{\sim}-4\;dB$ and output power ($P_{out}$) of 13 dBm. The chip size of the amplifier MMIC was $3.7{\times}1.4mm^2$.

  • PDF

Comparison of Antenna Parameters of R-/S-Band Standard Gain Horn Antennas

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Park, Jeong-Il
    • Journal of electromagnetic engineering and science
    • /
    • 제15권4호
    • /
    • pp.224-231
    • /
    • 2015
  • A comparison of the antenna parameters for R-band (1.7-2.6 GHz) and S-band (2.6-3.95 GHz) standard gain horn antennas has been performed by the Korea Research Institute of Standards and Science (KRISS), together with seven domestic participants from private companies and public institutions. Its purpose, as a proficiency test program of the 'Antenna Measurement Club' of KRISS, was to check equivalences in antenna parameter measurements between KRISS and the participants, particularly in the R-/S-band, to support antenna manufacturers and end users in Korea. The measurement parameters of this comparison are the power gain, radiation pattern, and reflection coefficient of the traveling standards for R-/S-band pyramidal standard gain horn antennas. The comparison used a gain comparison method and an extrapolation method to measure the power gain of the two traveling standards; the radiation patterns were measured in the far-field region of the transmitting and receiving antennas.

L 대역 EDFA 특성의 펌프 파장 의존성에 관한 연구 (Investigation of Pump Wavelength Dependence of Long-Wavelength-Band Erbium-Doped Fiber Amplifier using 1530nm-Band Pump)

  • 최보훈
    • 한국정보통신학회논문지
    • /
    • 제12권7호
    • /
    • pp.1249-1255
    • /
    • 2008
  • 1530nm 파장 대역이 L밴드 (long-wavelength-band) EDFA(erbium-doped fiber amplifler)를 위한 펌프 파장으로 연구되었다. 이 펌프 광원은 파장 가변 광원과 직렬 연결된 C 밴드 (conventional-band) EDFA로 제작되었다. 이 L밴드 EDFA는 순방향 펌핑 구조를 사용하였다. 1530nm 대역 내에서 1545nm 펌프 파장을 사용하였을 때 0.454B/mW 이득 계수를 얻었는데 이는 기존에 사용되는 1480nm 파장으로 펌핑 하였을 경우보다 2배 이상 높은 수치이다. 1530nm 파장 펌핑의 잡음지수는 가장 좋지 않은 경우가 6.36dB였는데 이는 1480nm 펌핑보다 0.75dB 높은 값이다. 제안된 펌핑 파장을 이용하는 L밴드 EDFA에서 얻은 이 같은 골은 이득 계수는 이 L밴드 EDFA가 전력 소모를 적게 한다는 것을 의미한다.

주택 창의 SHGC가 에너지소비에 미치는 영향에 관한 연구 (A study of Energy use Impacts by SHGCs of Windows in Detached House)

  • 박률;박종일
    • 설비공학논문집
    • /
    • 제22권4호
    • /
    • pp.189-196
    • /
    • 2010
  • U-factor and solar heat gain coefficient(SHGC) usually can be used as the index to evaluate the thermal performance. U-factor is a concept for heat loss by the temperature difference between inside and outside, so it's useful to be applied in heating season. But SHGC that indicates the fraction of heat from incident solar radiation that flows through a window by means of optical transmission, as well as absorption, re-radiation and convection is for cooling season. In other words, U-factor and SHGC of windows by cities have to be reflected to select the window of the energy conservation. The purpose of this research is to analyze the energy use impacts by SHGCs of windows for detached house in Inchon and Ulsan through energy simulation by eQUEST.

고이득 관측기를 이용한 적분 슬라이딩 모드 제어 (Integral sliding Mode Control with High-gain Observer)

  • 오승록;신준형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.233-236
    • /
    • 2002
  • We consider a single-input-single-output nonlinear system which can be represented in a normal form. The nonlinear system has a modeling uncertainties including the input coefficient uncertainties. A high-gain observer is used to estimate the states variables to reject a modeling uncertainty. A globally bounded output feedback integral sliding mode control is proposed to stabilize the closed loop system. The proposed integral sliding mode control can asymptotically stabilize the closed loop system in the it presence of input coefficient uncertainty.

  • PDF

태양열에 의한 냉방 및 난방시스템의 성능향상 (III) - 성층화계수의 예측을 위한 1차원 해석모델의 개발 - (The Improvement of the Performance of Solar Cooling and Heating Systems (III) - Development of One Dimensional Analytic Model for the Evaluation of Stratification Coefficients -)

  • 유재경;노승탁;이준식;정석호
    • 설비공학논문집
    • /
    • 제1권1호
    • /
    • pp.55-63
    • /
    • 1989
  • A one dimensional analytic model for the prediction of the stratification coefficient of a liquid-based solar heating system is developed. The stratification coefficient, $K_s$, is defined as the ratio of the actual useful energy gain to the energy gain that would be achieved if there were no thermal stratification in the storage tank. Previous studies incorporated only collector-side effects, but in this study both the collector and load-side effects are included for the overall performance evaluation.

  • PDF

이중 및 삼중 로이창호의 일사획득에 따른 사무소건물의 냉난방에너지 성능분석 (Heating & Cooling Energy Performance Analysis of an Office Building according to SHGC level of the Double & Triple Glazing with Low-e Coating)

  • 김효중;박재성;신우철;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.90-95
    • /
    • 2008
  • An SHGC(Solar Heat Gain Coefficient) is a determinant of total flux of solar radiation coming indoor and a critical factor in evaluating heating and cooling load. U-value represents heat loss while SHGC denominates heat gain. Recently, windows with high solar gain, mid solar gain or low solar gain are being produced with the development of Low-E coating technology. This study evaluated changes in energy consumption for heating and cooling according to changes in SHGC when using double-layered Low-E glass and triple layered Low-E glass in relation to double layered clear glass as base glass. An Office was chosen for the evaluation. For deriving optical properties of each window, WINDOW 5 by LBNL, an U.S. based company. and the results were analyzed to evaluate performance of heat and cooling energy on anannual basis using ESP-r, an energy interpretation program. Compared to the energy consumption of the double layered clear glass, the double layered Low-E glass with high solar gain consumed $69.5kWh/m^2,yr$, 9% more than the double layered clear glass in cooling energy. The one with mid solar gain consumed $63.1kWh/m^2,yr$, 1% less than the base glass while the one with low solar gain consumed $57.6kWh/m^2,yr$, 10% less than the base glass. When it comes to tripled layered glass, the ones with high solar showed 2% of increase respectively while the one with mid solar gain and low solar gain resulted 5% and 11% in decrease in energy consumption due to low acquisition of solar radiation. With respect to cooling energy. it was found that the lower the SHGC. the less energy consumption becomes.

  • PDF

벼의 호흡 특성 (Respiration Characteristics of Rough Rice)

  • 김동철;김의웅;금동혁
    • Journal of Biosystems Engineering
    • /
    • 제23권4호
    • /
    • pp.335-342
    • /
    • 1998
  • The objectives of this study were to evaluate respiration characteristics and develop empirical respiratory rate equations for short gain rough rice. The carbon dioxide concentrations generated from mush rice at four level temperatures(10, 20, 30, 4$0^{\circ}C$) and 4 level moisture contents(17.2, 21.5, 25.9, 31.6%, d.b.) were measured by gas chromatography. The respiratory rates' increased exponentially with gain temperature and also with moisture content The relationship between respiratory rate and gain temperature fitted the Arrehenius' and Core's equations very well. Two empirical respiratory rate equations were presented as a function of gain temperature and moisture content. The values of determination coefficient for the developed respiratory rate equations were 0.999, and the result of t-test showed that there were no significant differences between predicted and measured respiratory rates on significance level of 1%. Therefore, it appeared that respiratory rates predicted by the respiratory rate equations agreed well with measured values. An equation for predicting dry matter losses of rough rice during storage was presented by modifying the respiratory rate equations based on chemical reaction of decomposition of carbohydrate.

  • PDF

닭의 갑상선기능(甲狀腺機能)과 성장률(成長率)과의 상관관계(相關關係) (Correlation Between Thyroid Activity and Body Gain in Chicken)

  • 권종국;성재기;최형종
    • 대한수의학회지
    • /
    • 제10권1호
    • /
    • pp.1-4
    • /
    • 1970
  • Experiments were carried out in order to study the relationship of thyroid activity to growth potentiality in chicken. Further work was also performed to determine thyroid secretion rate and body gain of the different sexes. A correlation coefficient of 0.241 in the male and 0.237 in the female were obtained between daily gains and daily thyroid $^{131}I$ out put rate in the chicken. The correlation was not statistically significant, but the chicken with a lower thyroid activity tended to gain faster than those with a higher thyroid activity. The average daily gain of the female(12.13 gram) was significantly higher than the male (9.28 gram). The average daily thyroid secretion rate of male tended to have a higher rate, but it was not statistically significant.

  • PDF

송출공의 회전이 송출계수와 압력계수에 미치는 영향 (The Effect of Rotation of Discharge Hole on the Discharge Coefficient and Pressure Coefficient)

  • 하경표;구남희;고상근
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.948-955
    • /
    • 2003
  • Pressure coefficient in rotating discharge hole was measured to gain insight into the influence of rotation to the discharge characteristics of rotating discharge hole. Pressure measurements were done by the telemetry system that had been developed by the authors. The telemetry system measures static pressure using piezoresistive pressure sensors. Pressure coefficients in rotating discharge hole were measured in longitudinal direction and circumferential direction with various rotating speed and 3 pressure ratios. From the results, the pressure coefficient, and therefore the discharge coefficient, is known to decrease with the increase of Ro number owing to the increase of flow approaching angle to the discharge hole inlet. However, there exists critical Ro number where the decrease rate of discharge coefficient with the increase of Ro number changes abruptly; flow separation occurs from the discharge hole exit at this critical Ro number. Critical Ro number increases with the increase of length-to-diameter ratio, but the increase is small where the length-to-diameter ratio is higher than 3. The decrease rate of discharge coefficient with the increase of Ro number depends on the pressure recovery at the discharge hole, and the rate is different from each length-to-diameter ratio; it has tendency that the short discharge hole shows higher decrease rate of discharge coefficient.