• 제목/요약/키워드: fuzzy process

검색결과 1,497건 처리시간 0.027초

온도챔버의 퍼지 자동조정 제어시스템 (Fuzzy Self-Organizing Control of Environmental Temperature Chamber)

  • 김인식;권오석
    • 전자공학회논문지B
    • /
    • 제31B권1호
    • /
    • pp.34-40
    • /
    • 1994
  • The design and implementation of a fuzzy self-organizing controller for an environmental temperature chamber is discussed. The chamber is a non-linear, time-variant system with delay-time and dead-time. And the parameter tuning is required in PI control when the performance degraded. However the proposed fuzzy-SOC monitors the performance of the process. modifies the data base, and performs the delay-time compensation based on the idealized process model. A series of experiments was performed for the conventional PI and the fuzzy-SOC. These experimental results show the usefulness of the fuzzy-SOC.

  • PDF

활성슬러지 폐수처리장 폭기조 DO제어를 위한 퍼지 제어 알고리즘 연구 (Fuzzy algorithm of Automatic control for dissolved oxygen in Activated sludge aeration tank)

  • 손건태;김성덕;고주형
    • 한국환경과학회지
    • /
    • 제8권4호
    • /
    • pp.533-538
    • /
    • 1999
  • Fuzzy algorithm of automatic control for dissolved oxygen(DO) concentration in the aeration tank of an activated sludge process is proposed. Among variables repirometry and air flowrate are selected as significant input factors and the relationship with DO is estimated using a multiple regression model. The DO concentration and the amount of repirometry are fuzzified and the fuzzy rule base are determined. Using the fuzzy algorithm, the change of amount of air flowrate are determined and the change of amount of DO is derived.

  • PDF

활성오니 공정의 퍼지 모델 베이스형 제어기의 설계 (Design of fuzzy model-based controller for activated sludge process)

  • 김현기;오성권;황희수;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.922-927
    • /
    • 1991
  • This study is aimed to investigate a design problem of the fuzzy logic controller for the activated sludge process(ASP) in sewage treatment. The modeling technique proposed by Sugeno is used to express the ASP effectively and identification of a fuzzy model of the ASP is carried out utilizing actual operational data obtained from a metropolitan sewage plants. The model-based fuzzy controller is designed by rules generated from the identified ASP fuzzy model. Feasibility of the designed controller is tested through computer simulations.

  • PDF

상호연관성을 지닌 계층구조형문제의 평가 알고리즘 (On Evaluation Algorithm for Hierarchical Structure of Attributes with Interaction Relationship)

  • 이철영;이석태
    • 한국항만학회지
    • /
    • 제7권1호
    • /
    • pp.5-12
    • /
    • 1993
  • In complex decision making such as ill-defined system, one of the main problem is how to treat ambiguous aspect of the decision making. According to the complexity and ambiguity of the objective systems, many types of evaluation attributes are necessary for the rational decision and the relationship among the attributes become complex and fuzzy. Fuzzy integral is very effective to evalute the complex system with interaction between attributes but how to save the evaluation efforts in the decision making process of grading the membership of the objects or alternative is the problem to be tackled. Because the more object there are to evaluate, the number of decisions to made increase exponentially. Therefore, this paper aimes to propose a new evaluation algorithm based on fuzzy integral which can save the evaluator's efforts in decision making process. The proposed algorithm is constructed as follows : First, compose the fuzzy measure by introducing AHP(Analytical Hierachy Process) & mutual interaction coefficient. Second, generate fuzzy measure value of monotone family set for calculating the fuzzy integral. The effectiveness of the proposed algorithm is investigated through the example and sensitivity of interaction coefficient is illustrated.

  • PDF

Design Of Fuzzy Controller for the Steam Temperature Process in the Coal Fired Power Plant

  • Shin, Sang Doo;Kim, Yi-Gon;Lee, Bong Kuk;Bae, Young Chul
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제4권2호
    • /
    • pp.187-192
    • /
    • 2004
  • In this paper, we proposed the method to design fuzzy controller using the experience of the operating expert and experimental numeric data for the robust control about the noise and disturbance instead of the traditional PID controller for the main steam temperature control of the thermal power plant. The temperature of main steam temperature process has to be controlled uniformly for the stable electric power output. The process has the problem of the hunting for the cases of various disturbances. In that case, the manual action of the operator happened to be introduced in some cases. We adopted the TSK (Takagi-Sugeno-Kang) model as the fuzzy controller and designed the fuzzy rules using the informations extracted directly from the real plant and various operating condition to solve the above problems and to apply practically. We implemented the real fuzzy controller as the Function Block module in the DCS(Distributed Control System) and evaluated the feasibility through the experimental results of the simulation.

A Study on the Introduction of Fuzzy system into the Decision-Making process of HVAC designers

  • Woo, Se-Jin
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제4권1호
    • /
    • pp.12-17
    • /
    • 2004
  • This study is designed to grope for logical methods in the decision-making process of human beings such as creation and analysis. With this in mind, the paper worked with a process where the designers of a design team gather and analyze their opinions in a design process to decide on the HVAC system of buildings. The paper introduced the fuzzy theory, or one of the methods to quantitatively describe language values with ambiguous features, suggesting a method to determine the judgement and suggestion values of the HVAC designers with the characteristics of language variables as the values of design factors greatly influencing the HVAC system. As a result, the paper tested the possibility of the fuzzy system as a logical method to gather the judgement of HVAC designers in a stage of HVAC type selection exerting a great influence on the experience and judgement of the designers and having powerful linguistic features and to determine an appropriate HVAC type which can satisfy the suggested values of related design factors.

퍼지AHP를 이용한 교통신호제어 적합성에 관한 연구 (A Study on a Validity of Traffic Signal Control using Fuzzy Analytic Hierarchy Process)

  • 진현수
    • 한국지능시스템학회논문지
    • /
    • 제16권4호
    • /
    • pp.479-484
    • /
    • 2006
  • 본 논문은 퍼지 계층분석법을 이용하여 교통신호의 교차로에서의 적합성에 대해서 논의한다. 교차로에서의 교통신호는 현시, 주기둥이 현재의 교차로 상황에 적합한가를 구별하여 판별할 수 있다. 교통신호의 적합성 여부는 현시, 주기를 따로 구별한 신호체계에서의 지체차량의 지체시간을 비교하여 구별한다. 교통신호체계는 고정신호체계, 최적선호체계, 퍼지응용 신호체계를 구별하여 응용단계가 높은 신호체계가 적합성이 높음을 퍼지계층분석법을 이용하여 밝히고 이를 이용 새로운 체계의 교통신호 체계도 제시한다.

Fuzzy 전문가 제어계를 이용한 초임계 유체 추출 장치의 운전 (Operation of a supercritical fluid extraction process using a fuzzy expert control system)

  • 이대욱;이광순
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.669-675
    • /
    • 1991
  • Based on process analysis as well as extensive operation experience, two fuzzy expert control algorithms, for startup and control, are proposed for a supercritical fluid extraction process which has high interacting multivariable structure. In the proposed algorithms, a new simple defuzzification method which only requires four fundamental arithmetic rules is also presented. Through numerical simulations, control performance using the proposed control algorithm is compared with that of a different fuzzy algorithm by an other researcher and that of conventional PID-type controllers which are tuned by well-known optimal criteria. Also, the proposed control algorithm has been tested to the bench scale supercritical fluid extraction process. As a consequence, the proposed fuzzy expert controller has shown fast and robust control performance while the other controllers show sluggish and/or highly oscillatory responses.

  • PDF

농업용 필댐의 안전진단등급 평가법 개선을 위한 퍼지논리 적용법 개발 (A Development of Fuzzy-Logic Application for Improving Safety Diagnosis Rating Method of Agricultural Fill Dam)

  • 윤성욱;유찬
    • 한국농공학회논문집
    • /
    • 제65권4호
    • /
    • pp.33-43
    • /
    • 2023
  • In this study, it was developed and verified an application method of fuzzy-logic theory to the rating process of agricultural fill dam safety. A fuzzy-logic is very famous logical system when some decision making is made on the status of a lack of information. Three proxies were selected and configured membership functions (MFs) and these MFs were activated in the process of fuzzification procedures. Fuzzified vlaues were passed through the rule-based inference system, then fire strength could classified among cases of the rule-based inference system. To obtain final results, Mandani-type was adapted in the defuzzification process. As the results, it was shown the developed system can give a correct results that was compared with Matlab - fuzzy inference function. More ever it could perform the detailed analysis and improvement on the infrastructure safety rating process using classical diagnosis method.

퍼지 클러스터를 이용한 비선형 추론 (Nonlinear Inference Using Fuzzy Cluster)

  • 박건준;이동윤
    • 디지털융복합연구
    • /
    • 제14권1호
    • /
    • pp.203-209
    • /
    • 2016
  • 본 논문에서는 퍼지 클러스터를 이용한 비선형 추론을 위한 퍼지 추론 시스템을 소개한다. 전형적으로, 비선형 추론을 위한 퍼지 규칙의 생성은 일반적으로 입력 벡터 차원이 증가하면 규칙의 수가 지수적으로 증가하게 된다. 이러한 문제점을 해결하기 위해, 퍼지 클러스터를 표현할 수 있는 퍼지 클러스터링 알고리즘을 이용하여 입력 벡터 공간을 분산 형태로 분할하여 퍼지 모델의 규칙을 설계한다. 이러한 방법으로 복잡하고 비선형적인 공정을 퍼지 모델링 할 수 있다. 퍼지 규칙의 전반부는 퍼지 클러스터를 갖는 FCM 클러스터링 알고리즘에 의해 결정된다. 퍼지 규칙의 후반부는 4가지 형태의 다항식 함수의 형태를 가지며, 각 규칙의 후반부 파라미터들은 표준 최소자승법을 이용함으로써 추정된다. 그리고 비선형 공정의 특성 및 성능을 평가하기 위하여 비선형 공정으로 많이 이용되고 있는 데이터를 이용한다. 실험 결과는 비선형 추론이 가능하다는 것을 보여준다.