• Title/Summary/Keyword: fuses

Search Result 145, Processing Time 0.029 seconds

DISCO: A COMPUTER PROGRAM FOR PROTECTION COORDINATION OF DISTRIBUTION SYSTEMS (DISCO: 배전 계통 보호 기기 정정 프로그램)

  • Lee, Seung-Jae;Park, Young-Moon;Lee, Jeoung-Won;Yoon, Sang-Hyun;Yoon, Man-Chul;Lee, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.125-128
    • /
    • 1990
  • A program for the protection coordination of distribution systems is reported. The developed program nailed DISCO, consisting of two modules has a capability of selling the overcurrent relays, reclosers, sectionalizers, fuses which are commonly used in the primary feeder systems. Setting is performed in a downstream fashion starting from the substation, and coordination rules are applied identifying the pattern of the primary-backup devices based on the depth-first search. T/C curves of various devices are handled by digitization for accuracy and various graphics and windows are adopted for user-friendly interface.

  • PDF

Development of performance testing technique and equipments for the DC T/C characteristics of miniature fuses (소형퓨즈의 DC용단특성 성능평가기술 및 설비 개발)

  • Kim, Geun-Yong;Park, Nam-Ok;Park, Sung-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.847-848
    • /
    • 2006
  • 최근 안전인증 기술기준의 국제규격(IEC) 부합화에 따라 소형 퓨즈의 DC 시간/전류 특성(DC Time/Current characteristic, 이하 DC 용단특성)에 대한 시험이 중요한 성능평가항목으로 부각되고 있다. 특히 DC 용단특성을 시험하기 위해서는 규격에 적합한 DC 발생기 및 DC 용단시간도 정확하게 측정할 수 있는 시스템이 구축되어야 하므로, 그 성능 평가설비 또한 매우 중요하다고 할 수 있다. 본 논문에서는 안전기준 및 IEC 국제규격을 분석하고, 분석된 규격을 토대로 성능평가설비를 설계하여 국제적 수준의 시험기관 위상에 걸맞은 성능평가기술 기반을 구축하였다. 구축된 설비 및 개발된 성능평가기술은 향후 시험평가기술의 국제화에 중요한 역할을 할 것으로 기대된다.

  • PDF

Determination of panthenol, cholecalciferol and tocopherol in cosmetic products by gas chromatography-mass spectrometry in SIM mode

  • Hye-Jin Jeong;Myo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.22 no.2
    • /
    • pp.153-160
    • /
    • 1996
  • A novel simple method to detect vitamins in cosmetic products by gas chromatography-mass spectrometry(GC-MS) has been developed. Three vitamins(panthenol, cholecalciferol and tocopherol) were used for this study. Vitamins were prepared by dissolving in tetrahydrofuran(THF), and silylated with bis-trimethylsilyltrifluoroacetamide-trichloromethylsilane(BSTFA). Silated vitamins were separated on a fuses-silica capillary column coated with DB-5. The identification of each vitamin was accomplished by retention time and mass spectrum library search with a computer, and the quantitation was made in the selected-ion monitoring(SIM) mode of GC-MS. SIM mode had given sensitivity to determine 50pg of panthenol, 285pg of cholecalciferol and 130pg of tocopherol. Linearity was maintained over the range 0.005-0.20% for each vitamin. Each cosmetic product(i.e. hair tonic and lotion) was found to contain amounts of the vitamins. This method was sensitive and gave 77.5-99.9% recovery of each vitamin from these cosmetic products. From these results, we concluded that silylation with BSTFA followed by GC-MS analysis allows the simple, covenient and exact determination of panthenol, cholecalciferol and tocopherol.

  • PDF

Development of System For Cell Fusion Detection (세포 전기 융합 감지 장치에 관한 연구)

  • Kwon, Ki-Jin;Kim, Min-Soo;Park, Se-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1336-1338
    • /
    • 1994
  • Cell fusion device is an artificial equipment which fuses electrically two types of cells fed from the respective micropump to the fusion chamber by electric pulses. In this case, the detective sensor of flowing cell, along with passage, is required to control the time of pulses applied to cell and the injection of cells which are fed from inlet to micropump. There are two methods of detection of flowing cell; optical, impedance method. The difference of output for optical sensor is about 426mV for 805nm wavelength. about 37mV for 665nm wavelength. In impedance method, sensor output is 132.33mV at middle point and 117.10mV at edge point in the channel. Experimental results show that the optimal frequency range of sensor output is Iron 50Hz to 400Hz.

  • PDF

Analysis on the Crashworthiness of the Full Rake Korean Electric Multiple Unit Train (한국형 표준전동차 전체차량의 충돌안전도 해석 연구)

  • 구정서;김동성;조현직;권태수;최성규
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • In this paper, numerically evaluated is the crashworthiness of the new design of the standard Korea Electric Multiple Unit Train(K-EMU)[developed by the Korea Railway Research Institute]. The 4-car consist of K-EMU is analyzed under collision conditions such as normal coupling, heavy shunting, light collision and heavy collision to collide against another stationary one at 5 kph, 10 kph, 25 kph and 32 kph, respectively. Energy absorbing capacity of its draftgear commercially available in the market and to be equipped in K-EMU is evaluated under each collision condition. Analytical results show that draftgear only is not enough to provide necessary energy absorbing capacity. It is therefore concluded that additional energy absorbers like mechanical fuses should be adopted to improve the crashworthiness of K-EMU.

  • PDF

Consideration On Short Circuit Tests For Evaluation Of Breaking Performance Of Current-Limiting Fuses (한류형 전력퓨즈의 차단성능평가 위한 단락시험에 관한 고찰)

  • Kim, Dae-Won;Suh, Yoon-Taek;Yoon, Hak-Dong;Jung, Hee-Jae;Kim, Maeng-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.543-545
    • /
    • 2003
  • 한류형 전력퓨즈는 계통의 단락사고로 고장 전류가 흐를 때 퓨즈내부에서 발생하는 저항에 의해 고장전류를 회로 고유의 단락전류보다 아주 적은 값으로 제한하고 최소 시간내에 차단하여 회로를 보호하므로 계통기기의 단락용량를 최소한으로 감소시킬 수 있다. 본 논문에서는 이러한 한류형 전력퓨즈의 단락전류 차단성능 평가를 위해 동작책무에 따른 차단성능을 규명하고자 단락발전기를 사용하여 단락전류차단시험을 실시하고 그 결과를 제시하였으며, 또한 차단과정에 따른 스트레스들이 단락시험 시 차단성능에 미치는 영향을 다루고 있다.

  • PDF

Low-cost crowbar system and protection scheme in capacitor bank module (커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로)

  • Rim, Geun-Hie;Cho, Chu-Hyun;Lee, Hong-Sik;Pavlov, E.P.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2089-2091
    • /
    • 2000
  • Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.

  • PDF

Response of self-centering braced frame to near-field pulse-like ground motions

  • Rahgozar, Navid;Moghadam, Abdolreza S.;Aziminejad, Armin
    • Structural Engineering and Mechanics
    • /
    • v.62 no.4
    • /
    • pp.497-506
    • /
    • 2017
  • A low damage self-centering braced frame equipped with post-tensioning strands is capable of directing damage to replaceable butterfly-shaped fuses. This paper investigates the seismic performance of rocking braced frame under near-field pulse-like ground motions compared to far-field records. A non-linear time history analysis is performed for twelve self-centering archetypes. A sensitivity analysis is carried out to examine the influences of ground motion types and modeling parameters. Findings represent the proper efficiency of the self-centering system under both far-field and near-field pulse-like ground motions.

The study of short-circuit breaking characteristics of high-voltage alternating current switch-fuse combinations (교류 스위치-퓨우즈 조합기기의 차단특성에 관한 고찰)

  • Roh Chang-il;La Dae-Ryeol;Kim Sun-Koo;Jung Heung-Soo;Kim Won-Man;Lee Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.836-838
    • /
    • 2004
  • Alternating current switch-fuse combinations shall be designed so as to protect for load circuit of distribution line. this switch system shall be test on making and breaking at short-circuit current. the test dutys were performed to prove correct coordination between the switch and fuses in applied test conditions This paper describes characteristics and test method for prove to performance of alternating current switch-fuse combinations.

  • PDF

A Study on the Amenity of the Residential Environments reflected on the Residents : with a focus on the Environmental Quality of the Multi-Family Housing Estates (주민 의식에 나타난 주거환경의 쾌적성에 관한 연구 -공동주택단지의 주거환경의 질을 중심으로-)

  • 이재준;황기원
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.25 no.1
    • /
    • pp.3-17
    • /
    • 1997
  • The purpose of this study is to suggest an Amenity Meaning of the residential Environment reflected on the Residents. It focuses on the Environmental Quality through interviews and surveys of Multi-Family Housing Estates. The demand of Amenity as Environmental Quality of the Residential Environment will increase significantly in a short period of time. The Amenity Meaning fuses psychological and material elements, Also, these relate synthetic Environmental Qualities with Naturally Friendly Housing Estates. Thus, this paper may be used primarily by researchers, housing developers who may wish to incorporate the environmental quality of housing development.

  • PDF