• Title/Summary/Keyword: fuses

Search Result 145, Processing Time 0.048 seconds

A study on the flashes and filling defects of inner part and on problem-solving measures (내통의 플래시 및 충진불량에 대한 해결방법에 관한 연구)

  • Kim, Sei-hwan;Choi, Kye-kwang;Lee, Choon-kyu
    • Design & Manufacturing
    • /
    • v.6 no.2
    • /
    • pp.79-83
    • /
    • 2012
  • Inner part is used as an insulator in wire fuses. After injection molding, inner part has been showed flashes, filling defects and deformation. After production, operators have to cut off flashes, one by one. this process leads to continuous low productivity and loss of source materials. This study focuses on identifying the causes for flashes, filling defects, clamping force of injectors, mold adhesion, resin of liquidity and others, and on resolving those issues.

  • PDF

Terminal Myelocystocele : Pathoembryogenesis and Clinical Features

  • Lee, Ji Yeoun;Kim, Kyung Hyun;Wang, Kyu-Chang
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.3
    • /
    • pp.321-326
    • /
    • 2020
  • There has been confusion in the classification of terminal myelocystocele (TMCC) due to its diverse morphology and vague pathoembryogenesis. TMCC could be summarized as having the essential features of an elongated caudal spinal cord extruding out of the dorsal extraspinal space that fuses with the subcutaneous fat, which is in the shape of a trumpet-shaped cerebrospinal fluid-filled cyst. The extraspinal portion of the extruded spinal cord is nonfunctional. The morphological features suggest that TMCC is formed during secondary neurulation, specifically the failure of the degeneration of the secondary neural tube near the time of the terminal balloon. This review discusses the definition, as well as the clinical and surgical features, of TMCC with special emphasis on its pathoembryogenesis.

A Study on Electrical Fire of Small Ventilators due to Aged Degradation (경년열화에 의한 소형 환풍기의 전기화재에 관한 연구)

  • Lim, Jong Yong;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.22-26
    • /
    • 2016
  • "Always-on" small ventilators are likely to experience thermal decomposition of insulating material due to thermal, electrical, mechanical and environmental influences, and lose insulating properties by the process of oxidation and physiochemical reaction. This increases the risk of electrical fire because of layer short, short circuit, overload and Plastics are usually used to make ventilator and ventilator enclosures since they make less noise and are cheaper. Although more preferred than iron, plastic, a combustible material, has a higher risk of fire. In this study, several experiments were carried out to find out how RCD(Residual Current Protective Device) and Thermal fuses, which are electric motor protection devices, work and what needs to be done to reduce the risk of fire.

Measuring Technique for Height of Burst using Stereo-vision Recognition (스테레오 영상인식을 이용한 신관폭발고도 계측기술)

  • Kang, Gyu-Chang;Choi, Ju-Ho;Park, Won-U;Hwang, Ui-Seong;Hong, Seong-Su;Yoo, Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.194-203
    • /
    • 1999
  • This paper presents a measuring technique for bursting height of proximity fuses. This technique uses camera calibration to obtain the perspective transformation matrix describing the projection of the world coordinates to image coordinates, and calculates the world coordinates of bursting points from their image coordinates. The surface approximation algorithm by polynomial functions are also implemented.

  • PDF

Position Estimation of Free-Ranging AGV Systems Using the Extended Kalman Filter Technique (Extended Kalman Filter방법을 이용한 자유주행 무인 방송차의 위치 평가)

  • Lee, Sang-Ryong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.12
    • /
    • pp.971-982
    • /
    • 1989
  • An integrating position estimation algorithm has been developed for the navigation system of a free-ranging AGV system. The navigation system focused in this research work consists of redundant wheel encoders for the relative position measurement and a vision sensor for the absolute position measurement. A maximum likelihood method and an extended Kalman filter are implemented for enhancing the performance of the position estimator. The maximum likelihood estimator processes noisy, redundant wheel encoder measurements and yields efficient estimates for the AGV motion between each sampling interval. The extended Kalman filter fuses inharmonious positional data from the deadreckoner and the vision sensor and computes the optimal position estimate. The simulation results show that the proposed position estimator solves a generalized estimation problem for locating the vehicle accurately in space.

  • PDF

전력계통 고장전류 저감을 위한 한류기술 및 초전도 저항형 한류기 개발 동향 분석

  • 이방욱;강종성;박권배;오일성
    • Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.10-17
    • /
    • 2003
  • For limitation and interruption of short circuit currents from low voltage to extra high voltage applications, the electrical equipment including fuses and circuit breakers, are widely used today. But in order to anticipate increasing needs for effective and competitive device for limiting the growing fault current in electrical power systems, fault current limitation technologies and fault current limitation devices are widely introduced and investigated in these days. Furthermore, the applications of high temperature superconducting materials (HTSC) into the current limiting devices are new approach for developing of novel and effective col-rent limitation electrical equipment. In this research, the necessities of current limitation technology and the developed and developing current limitation devices for power systems are introduced. Finally, the investigation of resistive type fault current limiters which is under development by LG and KEPCO were introduced.

  • PDF

A Study on Crashworthiness of Rubber Tired AGT (고무차륜 경량전철의 충돌안전도 연구)

  • 구정서;한형석;조현직
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.4
    • /
    • pp.215-221
    • /
    • 2002
  • In the standard specifications for the urban EMU (Electric Multiple Unit) train, there are several items to ensure safety against accidents. The 21st to the 23rd items have much to do with the crashworthiness of the urban EMU train. In this study, a rubber-tired Automated Guide-way Transit (AGT) System under development by KRRI is numerically evaluated from the point of view of crashworthiness by applying the above crashworthiness items. The numerical results show that the design of the AGT satisfies the 22nd and 23rd items. But a design modification to adopt mechanical fuses is recommended to reduce impact accelerations with respect to the 21st item.

Near-infrared face recognition by fusion of E-GV-LBP and FKNN

  • Li, Weisheng;Wang, Lidou
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.1
    • /
    • pp.208-223
    • /
    • 2015
  • To solve the problem of face recognition with complex changes and further improve the efficiency, a new near-infrared face recognition algorithm which fuses E-GV-LBP and FKNN algorithm is proposed. Firstly, it transforms near infrared face image by Gabor wavelet. Then, it extracts LBP coding feature that contains space, scale and direction information. Finally, this paper introduces an improved FKNN algorithm which is based on spatial domain. The proposed approach has brought face recognition more quickly and accurately. The experiment results show that the new algorithm has improved the recognition accuracy and computing time under the near-infrared light and other complex changes. In addition, this method can be used for face recognition under visible light as well.

Study on the Possibility of Car Fire by Arbitrary Electrical Wiring (자동차 임의배선에 의한 화재발생 가능성 연구)

  • Kim, Min;Yoon, Jang-Soo
    • Congress of the korean instutite of fire investigation
    • /
    • 2010.12a
    • /
    • pp.91-119
    • /
    • 2010
  • There is an increasing number of car fires along with the increasing numbers of cars. The purpose of this study was to verify the possibility of fires caused by car tuning, which is one of the causes of car fires. The result showed that the possibility of car fires was increased by car tuning including replacement of headlights, excess of allowable current of wires or fuses by using multi cigar jacks, wire damage, earth fault, and vulnerability of wires and cables (sold in auto parts stores) to heat.

  • PDF

A Study on the Fuse Sizing Technique for the Protection of Satellite Power System (인공위성 전력 시스템 보호를 위한 퓨즈 선정 기법 연구)

  • Jeon, Hyeon-Jin;Lim, Seong-Bin;Lee, Sang-Rok
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Power system in satellite is protected by installing fuses, LCLs (Latching Current Limiters), etc. between satellite power supply and loads. In this paper, the fuse sizing technique for satellite power system protection is addressed. Detailed fuse sizing method is explained and it is shown that the single fuse connection method is mathematically subordinated to the parallel fuse connection method. In addition, appropriate fuse selection method is newly suggested under a situation where exact current characteristics of a load connected to a fuse is unknown.