• Title/Summary/Keyword: full zirconia

Search Result 88, Processing Time 0.026 seconds

A comparative study on the fracture behavior of zironia, glass infiltrated alumina and PFM full crown system (지르코니아, 유리침투알루미나 및 PFM 전부관 시스템의 파절 경향에 관한 비교연구)

  • Lee, Sang-Hyeok;Ahn, Jin-Soo;Kim, Myung-Ho;Lim, Bum-Soon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.235-242
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the fracture behavior of Zironia, glass infiltrated Alumina and PFM full crown system. Materials and methods: Fifteen crowns for each of 3 experimental groups (Zironia, glass infiltrated Alumina and PFM full crown) were made by the conventional method. The crowns mounted on the testing jig were inclined in 30 degrees to the long axis of the tooth and the universal testing machine was used to measure the fracture strength. Results: 1. The mean fracture strengths were $588.3{\pm}49.6MPa$ for zirconia system, $569.1{\pm}61.8MPa$ for PFM system and $551.0{\pm}76.5MPa$ for glass-infiltrated alumina system (P>.05). 2. The mean shear bond strengths were $25.5{\pm}5.6MPa$ for zirconia system, $38.9{\pm}5.0MPa$ for Ni-Cr alloy system and $39.4{\pm}5.1MPa$ for glass-infiltrated alumina system. 3. The chemical bonding was observed at interfaces between PFM or glass-infiltrated alumina and veneering porcelain, however, no chemical bonding was observed at interface between zirconia and veneering porcelain. Conclusion: With the study, the fracture strengths of PFM crown system had a higher fracture strength than conventional zirconia system crown and glass-infiltrated alumina crowns. and than the shear bond strengths glass-infiltrated alumina system had a higher shear bond strength than conventional PFM system and zirconia system.

Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prostheses

  • Barbin, Thais;Silva, Leticia Del Rio;Veloso, Daniele Valente;Borges, Guilherme Almeida;Presotto, Anna Gabriella Camacho;Barao, Valentim Adelino Ricardo;Groppo, Francisco Carlos;Mesquita, Marcelo Ferraz
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.329-337
    • /
    • 2020
  • PURPOSE. To verify the influence of computer-aided design/computer-aided manufacturing (CAD/CAM) implant-supported prostheses manufactured with cobalt-chromium (Co-Cr) and zirconia (Zr), and whether ceramic application, spark erosion, and simulation of masticatory cycles modify biomechanical parameters (marginal fit, screw-loosening torque, and strain) on the implant-supported system. MATERIALS AND METHODS. Ten full-arch fixed frameworks were manufactured by a CAD/CAM milling system with Co-Cr and Zr (n=5/group). The marginal fit between the abutment and frameworks was measured as stated by single-screw test. Screw-loosening torque evaluated screw stability, and strain analysis was explored on the implant-supported system. All analyses were performed at 3 distinct times: after framework manufacturing; after ceramic application in both materials' frameworks; and after the spark erosion in Co-Cr frameworks. Afterward, stability analysis was re-evaluated after 106 mechanical cycles (2 Hz/150-N) for both materials. Statistical analyses were performed by Kruskal-Wallis and Dunn tests (α=.05). RESULTS. No difference between the two materials was found for marginal fit, screwloosening torque, and strain after framework manufacturing (P>.05). Ceramic application did not affect the variables (P>.05). Spark erosion optimized marginal fit and strain medians for Co-Cr frameworks (P<.05). Screw-loosening torque was significantly reduced by masticatory simulation (P<.05) regardless of the framework materials. CONCLUSION. Co-Cr and Zr frameworks presented similar biomechanical behavior. Ceramic application had no effect on the biomechanical behavior of either material. Spark erosion was an effective technique to improve Co-Cr biomechanical behavior on the implant-supported system. Screw-loosening torque was reduced for both materials after masticatory simulation.

Oral rehabilitation of a patient with severely worn dentition using monolithic zirconia (단일구조 지르코니아 보철물을 이용한 심한 마모 환자의 전악 수복 증례)

  • Park, Jun-Seo;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.273-279
    • /
    • 2016
  • Severe tooth wear may lead to pathological changes of pulp, imbalance in occlusion as well as functional and esthetic problems. In this case, 34-year-old male came to the hospital because of generally worn dentition due to attrition and erosion. After evaluation, a full mouth restoration with elevation of the vertical dimension of occlusion was planned. After occlusion was stabilized by an occlusal stabilization appliance, centric relation position was recorded and subsequent provisional restorations were fabricated. After evaluation, a CAD-CAM (computer aided design-computer aided manufacturing) prosthetic restoration was carried out using monolithic zirconia. After 12 months of follow up observation, the patient was satisfied with function and esthetic appearance.

Comparative study of color reproducibility of zirconia using a dipping method and coating method (도포법 및 침전법을 이용한 지르코니아의 색조 재현성 비교 연구)

  • Lee, Hee-Jung;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Ji-Hwan;Kim, Hae-Young
    • Journal of Technologic Dentistry
    • /
    • v.35 no.3
    • /
    • pp.185-192
    • /
    • 2013
  • Purpose: The aim of this study was to compare with color reproducibility of the coating method and dipping method using a colour liquid. Methods: Two groups of square-shaped specimens ($10mm{\times}10mm$ in diameter, 1.5mm thickness) were prepared for analysis(n=15/group). The CM(Coating Method) group was fabricated as full zirconia specimens with the coating coloring method and Group DM(Dipping Method) was prepared as specimens of 0.7 mm-thick zirconia plate using the dipping coloring method and veneered with 0.8mm-thick porcelain. Color parameters were measured with ShadeEye $NCC^{(R)}$ spectrophotometer and color differences were calculated using the equation ${\Delta}E^*= \{({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2\}^{1/2}$. Non-parametric statistical methods, the Mann-Whitney test, and the Kruskal-Wallis test were used to analyze the data. Type one error rate was set at 0.05. Results: Color difference values larger than 7 were observed between specimens with the coating method and the dipping method, which were detectable difference in a clinical setting. Conclusion: Cautious application of the coating coloring method in a clinical setting and further researches to standardize the coating method are needed.

Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis

  • Peter Gehrke;Maria Julia Pietruska;Johannes Ladewig;Carsten Fischer;Robert Sader;Paul Weigl
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.4
    • /
    • pp.231-243
    • /
    • 2024
  • PURPOSE. The objective of the study was to analyze the impact of cement, bonding pretreatment, and ceramic abutment material on the overall color results of CAD-CAM ceramic crowns bonded to titanium-based hybrid abutments. MATERIALS AND METHODS. For single implant restoration of a maxillary lateral incisor a total of 51 CAD-CAM-fabricated monolithic lithium disilicate crowns were fabricated and subsequently bonded onto 24 lithium disilicate Ti-base abutments, 24 zirconia Ti-base abutments and 3 resin abutment replicas as a control group. The 48 copings were cemented with three definitive and one provisional cement on both grit-blasted and non-blasted Ti-bases. The color of each restoration and surrounding artificial gingiva was measured spectrophotometrically at predefined measuring points and the CIELAB (ΔEab) color scale values were recorded. RESULTS. The color outcome of ceramic crowns bonded to hybrid abutments and soft tissues was affected differently by cements of different brands. Grit-blasting of Ti-bases prior to cementing CAD-CAM copings affected the color results of allceramic crowns. There was a significant difference (P = .038) for the median ΔE value between blasted and non-blasted reconstructions at the cervical aspect of the crown. Full-ceramic crowns on zirconia Ti-base abutments exhibited significantly lower ΔE values below the threshold of visibility (ΔE 1.8). In all subcategories tested, the use of a highly opaque temporary cement demonstrated the lowest median ΔE for both the crown and the artificial gingiva. CONCLUSION. Various cements, core ceramic materials and airborne particle abrasion prior to bonding can adversely affect the color of Ti-base supported ceramic crowns and peri-implant soft tissue. However, zirconia CAD-CAM copings and an opaque cement can effectively mask this darkening.

The Morphology and Crystallography of Isothermal Martensite in Yttria Stabilized Zirconia

  • Pee, Jae-Hwan;Choi, Eui-Seok;Hayakawa, Motozo
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.2 s.285
    • /
    • pp.69-73
    • /
    • 2006
  • A full retention of the tetragonal phase with coarse grains $(50\~60\;{\mu}m)$ was possible with the specimen $ZrO_2-1.9\;mol\%\;Y_2O_3$. In these coarse grains, $\{101\}_t$ annealing twins were frequently observed, although they do not exist in the usual fine grained specimens. The morphology and growth rate of the isothermally formed individual products are studied at an optical microscopic level. The habit planes of both products are also identified by performing two-surface trace analysis on the grains whose orientations are determined by the Electron Back Scattering Pattern (EBSP) method. The morphologies of isothermal martensite were well-defined thin plates and lenticular types. The growth rate in their longitudinal directions was quite slow and temperature-dependent. A two-surface trace analysis, incorporated with the EBSP method, identified the habit planes near $\{013\}_c$, in agreement with previous reports obtained from TEM works.

Full-mouth rehabilitation with CAD/CAM monolithic zirconia in dentinogenesis imperfecta: a case report (상아질 형성 부전증 환자에서 CAD/CAM 단일 구조 지르코니아를 이용한 완전구강회복 증례)

  • Kim, Min-Kyoo;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung;Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.317-323
    • /
    • 2014
  • Dentinogenesis Imperfecta, with a high incidence rate of 1 : 6 - 8000, is inherited by autosomal dominant genetic transmission. This dental disorder causes discoloration of the teeth and the enamel and dentin show hypoplastic or hypocalcified defects which lead to frequent fractures and rapid attrition. Therefore, timely treatment is necessary for the preservation of the remaining teeth. In this particular case, a 19-year-old patient suffering from Type 1 dentinogenesis imperfecta showed signs of brownish hued teeth with multiple fractures, a loss of vertical dimension, excessive interdental space in the maxillary anterior teeth, and a lack of 5 posterior teeth. To improve the esthetic appearance of the anterior teeth, the vertical dimension was increased. Resin caps were used to alleviate the difficulty of taking an impression of multiple teeth at once. Monolithic zirconia materials used in this case showed high fracture strength and the ability to mask the discoloration of the teeth and therefore, functionally and esthetically favorable results were achieved.

Full mouth rehabilitation of edentulous patient with intellectual disability using implants and monolithic zirconia (1급 지적장애 환자에서 임플란트와 단일 구조 지르코니아를 이용한 완전구강회복 증례)

  • Jeong, Ki-Won;Kim, Sung-Hun;Han, Jung-Suk;Yeo, In-Sung;Yoon, Hyung-In
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.156-163
    • /
    • 2017
  • People with class I intellectual disability need lifelong assistance and protection from their surroundings due to impaired adaptive functioning. They have poor oral health and show higher prevalence of dental caries, periapical inflammation and tooth loss that require proper prosthetic restoration. Because removable prostheses for intellectually disabled patients often lack stability, retention, and maintenance, fixed prostheses are essential and the only available option is dental implants. In this case, a 45 year-old male patient with class I intellectual disability had poor oral hygiene with most of his teeth missing and visited the clinic to recover his masticatory function. Due to such systemic conditions, the definitive restoration of choice was the implant-supported fixed dental prosthesis made of biocompatible and highly strong monolithic zirconia. In consequence of the treatment process, the patient was able to improve his oral environment aesthetically and functionally.

Functional and esthetical full mouth rehabilitation with implant supported prostheses: A case report (고정성 임플란트 보철물을 이용한 완전구강회복 증례)

  • Yeon, Jae-Woong;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.81-85
    • /
    • 2015
  • This report describes the prosthetic treatment of a patient with multiple missing teeth. Installation of five fixtures on maxilla with sinus lift and six fixtures on mandible with ramal bone graft were performed. With implant supported all-ceramic with zirconia core using CAD/CAM technology and porcelain-fused-to-gold prosthesis, treatment with positive outcome which satisfies both functional and esthetical aspect was obtained.

Full mouth rehabilitation of an asthma patient with severe tooth wear and occlusion disharmony (심한 마모 및 교합 부조화를 가진 천식 환자의 전악 수복 증례)

  • Jo, Yu-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.22 no.4
    • /
    • pp.225-230
    • /
    • 2022
  • Objectives: Patients with excessive tooth wear should first be diagnosed for the etiology of the tooth wear. Causes of tooth wear include bruxism, clenching, and taking medications for systemic diseases. After identifying the cause of tooth attrition, the final prosthesis should be restored with an appropriate vertical dimension. Methods: A 79-year-old man with worn out teeth desired a whole dental treatment. He was on medications for high blood pressure and asthma. The treatment proceeded with a consultation with a medical doctor. The medications for asthma evoked multiple teeth wear and a loss of the vertical dimension. After recovery of 3 mm of vertical dimension, 2 months of evaluation was followed by an interim prosthesis. Results: The increased vertical dimension caused no problem in function and esthetics, and the final restoration was performed with a full monolithic zirconia crown. Group function, adequate anterior guidance, and the occlusal plane were determined. Conclusions: After the final restoration, the patient was both esthetically and functionally satisfied, and a night guard splint was delivered to prevent prosthesis fracture. The patient was informed about the potential tooth wear associated with asthma drugs and educated to visit the clinic regularly.