• Title/Summary/Keyword: full scale experiments

Search Result 189, Processing Time 0.03 seconds

Application of in-situ Flushing to the Soil Contaminated by Organic Compounds (유기물질에 의해 오염된 토양에 대한 in-situ세척기법의 적용성 연구)

  • 최상일;류두현;김형수
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.2
    • /
    • pp.61-72
    • /
    • 1996
  • A series of batch and lab-scale continuous tests were conducted to optimize the design parameters for the full-scale in-situ soil flushing experiments. The cleaning abilities of the surfactant solutions of Tween 80, Triton X-100 and SDS were compared for the soil artificially contaminated by hydrophobic organic contaminants: n-dodecane, naphthalene and anthracene. Tween 80 and Triton X-100 were shown to be efficient for n-dodecane. SDS and Tween 80 were shown to be efficient for naphthalene and anthracene. At the end of each column test, the sorbed amount of surfactant to soil was also measured. Tween 80 was found to be the least adsorbed surfactant to soil. The flushing ability at flowrate of 7 ml/min, was hampered comparing to flowrate of 3 and 5 ml/min. Initial pH of the soil did not significantly affect the flushing efficiencies. Tween 80 was determined as the most harmless surfactant for the Gram(+) and Gram(-) bacteria.

  • PDF

Reduced-Scale Experiments of the Partial Smoke Extraction System in Tunnel Fires (풀화재를 이용한 터널화재 부분배연 모델실험)

  • Lee, Eui-Ju;Yoo, Yong-Ho
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.58-64
    • /
    • 2006
  • Smoke extraction in tunnel fire is investigated experimently with thermal model. The object is a immersed tunnel, of which the partial extraction system exists between the tubes. The model tunnel is measured 12 m long, 0.5 m wide and 0.35 m high. The fire is simulated to pool fire and the size corresponds to full scale fire of 5 MW based on Froude modeling. The performance of partial extraction system is determined under two ventilations, natural and longitudinal ones. The results show that compared with longitudinal ventilation, the smoke extraction efficiency of natural ventilation is increased about 30% because of smoke stratification in tunnel. Also the efficiency is identical to the iso-thermal model. The results will be help for activation of the ventilation system in emergency such as in the event of tunnel fires.

Prediction of Plant Operator Error Mode (원자력발전소 운전원의 오류모드 예측)

  • Lee, H.C.;E. Hollnagel;M. Kaarstad
    • Proceedings of the ESK Conference
    • /
    • 1997.04a
    • /
    • pp.56-60
    • /
    • 1997
  • The study of human erroneous actions has traditionally taken place along two different lines of approach. One has been concerned with finding and explaining the causes of erroneous actions, such as studies in the psychology of "error". The other has been concerned with the qualitative and quantitative prediction of possible erroneous actions, exemplified by the field of human reliability analysis (HRA). Another distinction is also that the former approach has been dominated by an academic point of view, hence emphasising theories, models, and experiments, while the latter has been of a more pragmatic nature, hence putting greater emphasis on data and methods. We have been developing a method to make predictions about error modes. The input to the method is a detailed task description of a set of scenarios for an experiment. This description is then analysed to characterise thd nature of the individual task steps, as well as the conditions under which they must be carried out. The task steps are expressed in terms of a predefined set of cognitive activity types. Following that each task step is examined in terms of a systematic classification of possible error modes and the likely error modes are identified. This effectively constitutes a qualitative analysis of the possibilities for erroneous action in a given task. In order to evaluate the accuracy of the predictions, the data from a large scale experiment were analysed. The experiment used the full-scale nuclear power plant simulator in the Halden Man-Machine Systems Laboratory (HAMMLAB) and used six crews of systematic performance observations by experts using a pre-defined task description, as well as audio and video recordings. The purpose of the analysis was to determine how well the predictions matiched the actually observed performance failures. The results indicated a very acceptable rate of accuracy. The emphasis in this experiment has been to develop a practical method for qualitative performance prediction, i.e., a method that did not require too many resources or specialised human factors knowledge. If such methods are to become practical tools, it is important that they are valid, reliable, and robust.

  • PDF

Heat Transfer Analysis and Experiments of Reinforced Concrete Slabs Using Galerkin Finite Element Method (Galerkin 유한요소법을 이용한 철근콘크리트 슬래브의 열전달해석 및 실험)

  • Han, Byung-Chan;Kim, Yun-Yong;Kwon, Young-Jin;Cho, Chang-Geun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.567-575
    • /
    • 2012
  • A research was conducted to develop a 2-D nonlinear Galerkin finite element analysis of reinforced concrete structures subjected to high temperature with experiments. Algorithms for calculating the closed-form element stiffness for a triangular element with a fully populated material conductance are developed. The validity of the numerical model used in the program is established by comparing the prediction from the computer program with results from full-scale fire resistance tests. Details of fire resistance experiments carried out on reinforced concrete slabs, together with results, are presented. The results obtained from experimental test indicated in that the proposed numerical model and the implemented codes are accurate and reliable. The changes in thermal parameters are discussed from the point of view of changes of structure and chemical composition due to the high temperature exposure. The proposed numerical model takes into account time-varying thermal loads, convection and radiation affected heat fluctuation, and temperature-dependent material properties. Although, this study considered standard fire scenario for reinforced concrete slabs, other time versus temperature relationship can be easily incorporated.

A Study on Time Series Analysis of Membrane Fouling by using Genetic Algorithm in the Field Plant (유전자알고리즘을 이용한 막오염 시계열 예측 연구)

  • Lee, Jin Sook;Kim, Jun Hyun;Jun, Yong Seong;Kwak, Young Ju;Lee, Jin Hyo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.8
    • /
    • pp.444-451
    • /
    • 2016
  • Most research on membrane fouling models in the past are based on theoretical equations in lab-scale experiments. But these studies are barely suitable for applying on the full-scale spot where there is a sequential process such as filtration, backwash and drain. This study was conducted in submerged membrane system which being on operation auto sequentially and treating wastewater from G-water purification plant in Incheon. TMP had been designated as a fouling indicator in constant flux conditions. Total volume of inflow and SS concentration are independent variables as major operation parameters and time-series analysis and prediction of TMP were conducted. And similarity between simulated values and measured values was assessed. Final prediction model by using genetic algorithm was fully adaptable because simulated values expressed pulse-shape periodicity and increasing trend according to time at the same time. As results of twice validation, correlation coefficients between simulated and measured data were $r^2=0.721$, $r^2=0.928$, respectively. Although this study was conducted limited to data for summer season, the more amount of data, better reliability for prediction model can be obtained. If simulator for short range forecast can be developed and applied, TMP prediction technique will be a great help to energy efficient operation.

Integrated Eco-Engineering Design for Sustainable Management of Fecal Sludge and Domestic Wastewater

  • Koottatep, Thammarat;Polprasert, Chongrak;Laugesen, Carsten H.
    • Journal of Wetlands Research
    • /
    • v.9 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • Constructed wetlands and other aquatic systems have been successfully used for waste and wastewater treatment in either temperate or tropical regions. To treat waste or wastewater in a sustainable manner, the integrated eco-engineering designs are explained in this paper with 2 case studies: (i) a combination of vertical-flow constructed wetland (CW) with plant irrigation systemfor fecal sludge management and (ii) integrated CW units with landscaping at full-scale application for domestic wastewater treatment. The pilot-scale study of fecal sludge management employed 3 vertical-flow CW units, each with a dimension of $5{\times}5{\times}0.65m$ (width ${\times}$ length ${\times}$ media depth) and planted with cattails (Typha augustifolia). At the solid loading rate of 250 kg total solids (TS)/$m^2.yr$ and a 6-day percolate impoundment, the CW system could achieve chemical oxygen demand (COD), TS and total Kjeldahl nitrogen (TKN) removal efficiencies in the range of 80 - 96%. The accumulated sludge layers of about 80 - 90 cm was found at the CW bed surface after operating the CW units for 7 years, but no clogging problem has been observed. The CW percolate was applied to 16 irrigation Sunflower plant (Helianthus annuus) plots, each with a dimension of $4.5{\times}4.5m$ ($width{\times}length$). In the study, the CW percolate were fed to the treatment plots at the application rate of 7.5 mm/day but the percolate was mixed with tap water at different ratio of 20%, 80% and 100%. Based on a 1-year data of 3-crop plantation were experimented, the contents of Zn, Mn and Cu in soil of the experimental plots were found to increase with increasing in CW percolate ratios. The highest plant biomass yield and oil content of 1,000 kg/ha and 35%, respectively, were obtained from the plots fed with 20% or 50% of the CW percolate, whereas no accumulation of heavy metals in the plant tissues (i.e. leaves, stems and flowers) of the sunflower is found. In addition to the pilot-scale and field experiments, a case study of the integrated CW systems for wastewater treatment at Phi Phi Island (a Tsunami-hit area), Krabi province, Thailand is illustrated. The $5,200-m^2$ CW systems on Phi Phi Island are not only for treatment of $400m^3/day$ wastewater from hotels, households or other domestic activities, but also incorporating public consultation in the design processes, resulting in introducing the aesthetic landscaping as well as reusing of the treated effluent for irrigating green areas on the Island.

  • PDF

Experimental Investigation of the CHF for the Narrow Rectangular Channel in the Downward Flow (좁은 사각 유로 내 하향류 유동 조건에서 임계열유속 실험 연구)

  • Kim, Hui Yung;Yun, Byong Jo;Bak, Jin Yeong;Park, Jong Hark;Chae, Heetaek;Park, Cheol
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.153-162
    • /
    • 2016
  • Experimental investigation was carried out on the CHF(Critical Heat Flux) under downward flow condition in narrow rectangular channels simulating subchannel of plate-type-fuel for JRTR(Jordan Research and Training Reactor). The experiments covers the license requirement of the research reactor. Two test sections used in this study simulate full scale subchannels for fission moly uranium target and plate-type-fuel, respectively. From the experimental results, the parameters affecting on the CHF are investigated. By using experimental data, the existing CHF prediction models were evaluated. Finally, the applicability of correlations were analysed to predict CHF in the narrow rectangular channel under the downward flow condition.

Static performance of a new GFRP-metal string truss bridge subjected to unsymmetrical loads

  • Zhang, Dongdong;Yuan, Jiaxin;Zhao, Qilin;Li, Feng;Gao, Yifeng;Zhu, Ruijie;Zhao, Zhiqin
    • Steel and Composite Structures
    • /
    • v.35 no.5
    • /
    • pp.641-657
    • /
    • 2020
  • A unique lightweight string truss deployable bridge assembled by thin-walled fiber reinforced polymer (FRP) and metal profiles was designed for emergency applications. As a new structure, investigations into the static structural performance under the serviceability limit state are desired for examining the structural integrity of the developed bridge when subjected to unsymmetrical loadings characterized by combined torsion and bending. In this study, a full-scale experimental inspection was conducted on a fabricated bridge, and the combined flexural-torsional behavior was examined in terms of displacement and strains. The experimental structure showed favorable strength and rigidity performances to function as deployable bridge under unsymmetrical loading conditions and should be designed in accordance with the stiffness criterion, the same as that under symmetrical loads. In addition, a finite element model (FEM) with a simple modeling process, which considered the multi segments of the FRP members and realistic nodal stiffness of the complex unique hybrid nodal joints, was constructed and compared against experiments, demonstrating good agreement. A FEM-based numerical analysis was thereafter performed to explore the effect of the change in elastic modulus of different FRP elements on the static deformation of the bridge. The results confirmed that the change in elastic modulus of different types of FRP element members caused remarkable differences on the bending and torsional stiffness of the hybrid bridge. The global stiffness of such a unique bridge can be significantly enhanced by redesigning the critical lower string pull bars using designable FRP profiles with high elastic modulus.

Research for establishing a model of optimizing civilian withdrawal plan for the border area (접경지역 최적 주민철수 계획수립을 위한 모형 연구)

  • Jung, Jae Hwan;Yun, Ho Yeong;Jeong, Chang Soon;Kim, Kyung Sup
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.219-229
    • /
    • 2018
  • Purpose: This research proposes an optimization model for effective evacuation routing and scheduling of civilians near the border area when full-scale war threats heighten. Method: To reflect the reality, administrative unit network is created using Kruscal's Algorithm, Harmony Search, CCRP based on the geographical features, population, and traffic data of real cities, and then, optimal civilian evacuation routes are found. Results: Optimal evacuation routes and schedules are computed by repetitive experiments, and it is found that the scenario that minimizes the average civilian evacuation time is effective for the civilian evacuation plan. Conclusion: By using the civilian evacuation plan this research proposes, at the time of establishing the actual civilian evacuation plan, quantitative analysis is used for the effective plan making rather than only depending.

Non-thermal Plasma Process for simultaneous removal of SO2/NOx from a Sintering Plant of Steel Works

  • Nam, Chang-Mo;Mok, Young-Sun;Kwon, Gi-Hong;Suh, You-Duck;Cho, Byeung-Rak
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.1
    • /
    • pp.81-86
    • /
    • 2003
  • For the simultaneous removal of $SO_2$/NOx from an iron-ore sintering plant, industrial plasma experiments have been conducted with a flue gas flow rate of $5,000Nm^3/hr$. The maximum 40kW power using the magnetic pulse compression (MPC) system generates a peak value of 100-150kV pulse voltage with its risetime of 200nsec and full width at half maximum (FWHM) of 500nsec, and with a frequency <300Hz. The plasma reactor module adopts a wire-plate structure with a gap of 200-400mm ID between plates. Initial concentrations of $SO_2$ and NOx were around 100-150ppm, respectively in the presence of 15% $O_2$ and <10% $H_2O$. Various reaction parameters such as specific energy ($Whr/Nm^3$), $NH_3$ injection with corona discharge, flow rate and injection of hydrocarbons were investigated for $SO_2$/NOx removal characteristics. About 90/65% of $SO_2$/NOx were simultaneously removed with a specific energy of $3.0Whr/Nm^3$ when both $NH_3$ and hydrocarbons were injected. Practical implications that the pilot-scale plasma results provide are further discussed.

  • PDF