• 제목/요약/키워드: fuel cell control

검색결과 423건 처리시간 0.034초

연료전지 철도차량 적용을 위한 인터리브드 다상 승압형 컨버터 제어 (The control of Interleaved Multi-phase Boost Converter for Application of a Fuelcell Railway Vehicle)

  • 김재문
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1925-1930
    • /
    • 2016
  • Fuel cell power generation system, unlike conventional energy sources, converts chemical energy into electrical energy through electrochemical reaction of hydrogen and oxygen. This paper presents the control of interleaved multi-phase boost converter as the feasibility study on small-scale prototype electric railway vehicle application using fuel cell generation system. PSIM simulation program is to be used to implement the modeling of the electrical fuelcell as well as traction motor control with interleaved multi-phase boost converter. Comparing the input current ripple rate, two-phase interleaved boost converter is less than the boost converter. But the more multi-phase not less proportional to the ripple factor. we confirmed that the amplitude of the input current ripple rate of converter depend on duty ratio.

5kW급 SOFC 시스템용 전력변환장치 개발 (Development of 5kW PCS for SOFC System)

  • 이정민;최준영;김영욱;이재홍;서영거;서인영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.332-333
    • /
    • 2010
  • The 5kW SOFC(Solid Oxide Fuel Cell) System is composed to 3kW parallel Fuel Cell. We propose to the parallel control of 5kW PCS in the unbalance condition of fuel cell. The developed 5kW PCS can be found control ability of DC/DC converters in the operating conditions of the unbalanced parallel operation. It is verify to the control characteristics by simulation and experiment.

  • PDF

연료전지 하이브리드 전력 시스템에 대한 에너지 제어 시뮬레이션 (Development of Energy Control Simulation for Fuel Cell Hybrid System)

  • 한수빈;송유진;정봉만;박석인;정학근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.355-358
    • /
    • 2005
  • This paper describes an simulation method to utilize the hybrid system with fuel cell and battery. The hybrid system has unique advantage to manage energy state between high energy system (fuel cell) and high power system (battery) according to various type of load. For proper design, the hybrid system is modelled and simulated. Especially, battery SOC is used as an important control parameter to decide the energy control.

  • PDF

연료전지용 계통연계형 전력변환기의 전력품질개선제어 (Improvement Control of Power Quality of Grid-Tied PCS for Fuel Cell System)

  • 이정민;정상민;서인영;한세희;목형수;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.77-79
    • /
    • 2007
  • The phase angle of the utility voltage is used in current control of grid-tied fuel cell power converter. Therefore if the detection of phase angle is a problem, Current control is affected by the distorted phase angle. This paper presents a problem of synchronous reference frame PLL algorithm for single-phase systems and proposes compensated synchronous reference frame PLL algorithm. The proposed method helps power quality improvement of grid-tied fuel cell power converter under distorted utility conditions. Simulation and experimental results are presented to demonstrate the validity of the proposed method.

  • PDF

고분자 전해질 연료전지용 막가습기의 상대습도 추정을 위한 소프트센서 개발 (Soft Sensor Development for Predicting the Relative Humidity of a Membrane Humidifier for PEM Fuel Cells)

  • 한인수;신현길
    • 한국수소및신에너지학회논문집
    • /
    • 제25권5호
    • /
    • pp.491-499
    • /
    • 2014
  • It is important to accurately measure and control the relative humidity of humidified gas entering a PEM (polymer electrolyte membrane) fuel cell stack because the level of humidification strongly affects the performance and durability of the stack. Humidity measurement devices can be used to directly measure the relative humidity, but they cost much to be equipped and occupy spaces in a fuel cell system. We present soft sensors for predicting the relative humidity without actual humidity measuring devices. By combining FIR (finite impulse response) model with PLS (partial least square) and SVM (support vector machine) regression models, DPLS (dynamic PLS) and DSVM (dynamic SVM) soft sensors were developed to correctly estimate the relative humidity of humidified gases exiting a planar-type membrane humidifier. The DSVM soft sensor showed a better prediction performance than the DPLS one because it is able to capture nonlinear correlations between the relative humidity and the input data of the soft sensors. Without actual humidity sensors, the soft sensors presented in this work can be used to monitor and control the humidity in operation of PEM fuel cell systems.

200 W급 휴대용 고분자 전해질막 연료전지 시스템 개발 (Development of a 200 W Portable PEM Fuel Cell System)

  • 한훈식;김윤호;조창환;김서영;현재민
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.91-101
    • /
    • 2012
  • A 200 W portable polymer electrolyte membrane fuel cell (PEMFC) system is developed. The PEMFC system consists of an air-cooled fuel cell stack module, a fuel supply subsystem, a power management subsystem, and a control electronics subsystem. The control logic is designed for the stable system operation. The system-level performance evaluation discloses that the present PEMFC system provides a rated power output of 200.5 W at 13.4 V with the maximum balance-of-plant (BOP) efficiency of 72%, and maximum system efficiency based on lower heating value (LHV) is 37% at 120.7 W system power output.

부하추종 운전방법에 따른 고체산화물 연료전지/가스터빈 하이브리드 동력 시스템의 부분부하 성능특성 (Part-load Performance Characteristics of a Solid Oxide Fuel Cell/Gas Turbine Hybrid Power System Operating with Various Load-following Operation Modes)

  • 김재훈;양진식;노승탁;손정락
    • 대한기계학회논문집B
    • /
    • 제30권3호
    • /
    • pp.193-200
    • /
    • 2006
  • The purpose of this study is to compare the part-load performance of a SOFC/GT hybrid power system with three different kinds of load-following operation modes. The primary mode for the part load operation of a hybrid power system is the reduction of supplied fuel (e.g., fuel control mode) to the hybrid system. The other two options, i.e., variable speed and VIGV controls, are related to the reduction of supplied air simultaneously with the reduction of supplied fuel to the system. With the performance analysis of a SOFC/GT hybrid power system, it is concluded that the variable speed con佐ol mode Provides the best performance for the part-load operations. It is also found that the VIGV control mode, with its better performance behavior than the fuel control mode, can be used as an important option for the part-load operation especially in case that the variable speed control mode can not be adopted.

Low Frequency Current Ripple Mitigation of Two Stage Three-Phase PEMFC Generation Systems

  • Deng, Huiwen;Li, Qi;Liu, Zhixiang;Li, Lun;Chen, Weirong
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2243-2257
    • /
    • 2016
  • This paper presents a two stage three-phase proton exchange membrane fuel cell (PEMFC) generation system. When the system is connected to a three-phase load, it is very sensitive to the characteristics and type of the load. Especially unbalanced three-phase loads, which result in a pulsating power that is twice the output frequency at the inverter output, and cause the dc-link to generate low frequency ripples. This penetrates to the fuel cell side through the front-end dc-dc converter, which makes the fuel cell work in an unsafe condition and degrades its lifespan. In this paper, the generation and propagation mechanism of low frequency ripple is analyzed and its impact on fuel cells is presented based on the PEMFC output characteristics model. Then a novel method to evaluate low frequency current ripple control capability is investigated. Moreover, a control scheme with bandpass filter inserted into the current feed-forward path, and ripple duty ratio compensation based on current mode control with notch filter is also proposed to achieve low frequency ripple suppression and dynamic characteristics improvement during load transients. Finally, different control methods are verified and compared by simulation and experimental results.

Effects of Reynolds Number and Shape of Manifold on Flow Rate in Separator for Polymer Electrolyte Fuel Cell (ICCAS 2004)

  • Huang, Chaii;Ozawa, Yoshikuni;Ennoji, Hisayuki;Iijima, Toshio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.68-71
    • /
    • 2004
  • Recently, a great deal of research and development of a fuel cell have been carried out to solve problems on the drain of fossil fuel, air pollution and global warning. In order to improve the efficiency of a fuel cell, it is necessary to clarify the flow in separator. In this study, distributions of velocity flow rate and pressure, and streamlines are examined in detail from numerical analysis with CFD code. In the experiment the distribution of flow rate is measured and flow in the each grooves of the separator is visualized by dye method changing Reynolds number. Furthermore, effects of size of the inlet and outlet manifolds and shape of ribs near the inlet outlet on the distributions of flow and pressure are examined.

  • PDF

배전계통집 연겨계 연료전지 발전시스템의 제어기 모델링 (Modeling of a Controller for Fuel Cell Plants Connected to a Power Distribution Network)

  • 노경수;박왕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.516-518
    • /
    • 2000
  • This paper presents a methodology for effective control of fuel cell devices connected to the electric utility distribution network. A controller is designed for a fuel cell power plant to assist the conventional generators to damp out oscillations, which is possible by utilizing the fast response characteristic of fuel cells. Computer model of the controller is proposed and its effectiveness is proved by a sample test. Fuel cell devices can be used to improve power system stability when these are connected to a distribution system.

  • PDF