• Title/Summary/Keyword: frost resistance

Search Result 113, Processing Time 0.023 seconds

A Study on Temperature Variation of Contact Wire by De-icing System (해빙시스템에 의한 전차선의 온도변화에 관한 연구)

  • Ahn, Byeong-Lib;Lee, Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.69-74
    • /
    • 2008
  • The frost and freezing on contact wire in winter is a very serious problem Shocks at the mechanical interface of the collecting strips of the pantograph and the contact wire. Extra electrical resistance, which may affect quality of current collection at the contact wire / collecting strips of pantograph interface. De-icing system is to melt frost or freezing in contact wire. The principle of do-icing system is to melt frost or ice by Joule heat of contact wire impedance. The temperature of the contact wire was increased with increasing the current. But temperature of contact wire was decreased with increasing the velocity of the wind.

An Experimental Study on the Resistance of Concrete Included Rice Husk Ash Against Rapid Freezing and Thawing (왕겨재를 혼입한 콘크리트의 동결융해 저항성에 관한 실험적 연구)

  • 이준구;박광수;이응찬;김한중
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.294-300
    • /
    • 1999
  • After researching the physical properties of the concrete included Rice Husk Ash(RHA concrete) and workability of fresh concrete admixed RHA, we have tested durability of RHA-concrete against freeaing and thawing in the winter using rapid freezing and thawing test method(KS F 2456) . There aretwo hypotheses to explain the failure mechanism of a freezing and thawing action. First, the hydraulic pressure in the pores of freezing concrete make an internal stress of concrete structures outbreaking micro crack in the face of concrete, Second, Frost action causing damage to cement paste repeatedly come from soil frost action, freezing water in the capillaries. Initial Relative Dynamic Modulus of Elasticity (DME) was biggest in cae of unit binder weight 600kgf/㎥ and relative dynamic modulus of elasticity increased until 300cycles. In general , initial relative DME was proportional to unit binder weight . Relative DME was decreased in proportion to unit binder weight in the case of 300, 400, 500kgf/㎥ , but relative DME fo the others remained more than 90% until 300 cycles. It was not good effect of intermixed RHA to concrete in case of below unit binder weight 300kgf/㎥ and the resistance of freezing and thawing was not good either.

  • PDF

A Study on the Strength Properties of Mortar Under Various Types and Contents of Accelerators for Freezing Resistance (내한촉진제의 종류 및 혼입양 변화에 따른 모르터의 강도특성에 관한 연구)

  • Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon;Kim, Dong-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.2
    • /
    • pp.151-156
    • /
    • 2002
  • When fresh concrete is exposed to low temperature, the concrete may suffer frost damage due to freezing at early ages and strength development may be delayed. One of the solution methods for resolve these problems is to reduce freezing temperature of concrete by the use of chemical admixture called Accelerators for freezing resistance. In this study, we investigate the effect on strength development of cement mortar using accelerators for freezing resistance with the variance curing condition. As the result of this study, the mortar using accelerators for freezing resistance show that continuously strength development in curing condition of -5$^{\circ}C$. And compressive strength under the variance temperature condition was higher than constant temperature condition in same maturity.

An Experimental Study on Freezing-Thawing Resistance of Concrete Using Ground Granulated Blast-Furnace Slag (고로슬래그 미분말을 사용한 콘크리트의 동결융해 저항성에 대한 실험적 연구)

  • 남용혁;최세규;김동신;김생빈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.148-153
    • /
    • 1996
  • Concrete with ground granulated blast-furnace slag can be affected by frost attack because the reaction of hydration is slow at the early age. In this study, therefore, the freezing and thawing test has been carried out to investigate the freezing and thawing resistance on concrete with ground granulated blast-furnace slag. The freezing and thawing test has been performed on concrete a blended cement, which was substituted by ground granulated blast-furnace slag with 4 kinds of ratio (non-admixture, 20%, 40% and 60%). And also tested on concrete added the AE agents to the concrete of same mix proportion to search the improvement effects about the resistance. As a result, the freezing and thawing resistance showed a tendency of reduction in proportion to the increase of the substitution ratio. For non-AE concrete, resistances of the freezing and thawing were very poor as the durability index indicated less than 5.8%. For AE concrte, resistance of the freezing and thawing were excellent as the durability index indicated more than 80.9%.

  • PDF

A Study on the Freezing and Strength Properties of Cement Mortar using Accelerator for Freezing Resistance (내한촉진제를 이용한 시멘트 모르터의 동결 및 강도특성에 관한 연구)

  • 박상준;김동석;원철;이상수;김영진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1267-1272
    • /
    • 2000
  • When fresh concrete is exposed to low temperature, the concrete may suffer frost damage due to freezing at early ages and strength development may be delayed. These are problems on cold weather concrete. One of the solution methods for resolving these problems has been to reduce the freezing temperature of concrete by the use of chemical admixtures called Accelerators for freezing resistance. Therefore, in this study, we executed freezing temperature of mortar, setting and strength properties with using water reducing accelerator and accelerators for freezing resistance which are producted internationally. As a result of this experiment, the freezing temperature of mortar is lower and the setting property is promoted when the admixing content of accelerators for freezing resistance is increased. Moreover, the compressive strength of mortar used accelerators for freezing resistance represented the result which is similar with result of analysis of compressive strength increase with using logistic curve formula, but in the case of plain and using water reducing accelerator, there is no relation between logistic curve formula, maturity and compressive strength.

A Dynamic Characteristic of the Multi-Inverter Heat Pump with Frosting (착상을 수반한 멀티 가변속 열펌프의 동특성)

  • ;;Shigeru Koyama
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.337-345
    • /
    • 2003
  • In the case of heat exchangers operating under frosting condition, the growth of frost layer causes the heat exchanger to increase the thermal resistance and pressure loss of the air flow. In this paper, a transient characteristic prediction model of the heat transfer for multi inverter heat pump with frosting on its surface was presented taking into account the change of the fin efficiency due to the growth of the frost layer. In this dynamic simulation program, which was peformed for a basic air conditioning system model, such as evaporator, condenser, compressor, linear electronic expansion valve (LEV) and bypass circuit. The theoretical model was driven from the obtained heat transfer coefficient and mass transfer coefficient, independently. And we consider heat transfer performance was only affected by a decrease of the wind flow area. The calculated results were compared with some cases of experiments for frosting conditions.

A Study on the Evaluation of Frost Damage of High-Flowing Concrete using Blast-Furnace Slag (고로슬래그미분말을 사용한 고유동콘크리트의 시공을 위한 내동해성의 평가)

  • 권영진
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.157-162
    • /
    • 2001
  • Recently, lots of studies for high flowing concrete have been suggested under practical use that it is only a way to solve the confronted problem. However, most studies have been concentrated on the manufacture method and properties of fresh concrete, but there is few studies for the durability of hardened concrete, specially for the freezing and thawing. Therefore this study is to investigate for the resistance of high-flowing concrete using finely ground granulated furnace blast slag to frost with experimental parameters, such as binder, ratio of replacement of granulated furnace blast slag, superplasticizer, curing method and blain surface area of granulated furnace blast slag.

  • PDF

Development of the Dynamic Simulation Program of a Multi-Inverter Heat Pump under Frosting Conditions

  • Park Byung-Duck;Lee Joo-Dong;Chung Baik-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.3
    • /
    • pp.113-122
    • /
    • 2004
  • In case of heat exchangers operating under frosting condition, the thermal resistance and the air-side pressure loss increase with a growth of frost layer. In this paper, a transient characteristic prediction model of the heat transfer for a multi-inverter heat pump with frosting on its surface was presented by taking into account the change of the fin efficiency due to the growth of the frost layer. This dynamic simulation program was developed for a basic air conditioning system composed of an evaporator, a condenser, a compressor, a linear electronic expansion valve, and a bypass circuit. The theoretical model was derived from measured heat transfer and mass transfer coefficients. We also considered that the heat transfer performance was only affected by the decrease of wind flow area. The calculated results were compared with the experimental results for frosting conditions.

The Effect on Strength Development of Cement Mortar using Accelerators for Freezing Resistance with the Curing Condition (양생조건이 내한촉진제를 사용한 시멘트 모르타르의 강도증진에 미치는 영향에 관한 연구)

  • Won, Cheol;Kim, Dong-Seok;Park, Sang-Joon;Lee, Sang-Soo;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.533-536
    • /
    • 2001
  • When fresh concrete is exposed to low temperature, the concrete may suffer frost damage due to freezing at early ages and strength development may be delayed. One of the solution methods for resolving these problems is to reduce freezing temperature of concrete by the use of chemical admixture called Accelerators for freezing resistance. In this study, we investigate the effect on strength development of cement mortar using accelerators for freezing resistance with the variance curing condition. As the result of this study, the mortar using accelerators for freezing resistance show that continuously strength development in curing condition of -5$^{\circ}C$. And compressive strength under the variance temperature condition was higher than fixed temperature condition in same maturity.

  • PDF

The Relationship between Microstructure and Freezing Thawing Resistance of Polymer-Cement Mortars (폴리머-시멘트 모르타르의 미세구조 동결융합 저항성의 관계)

  • ;;田英治(Eiji Kamada)
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.9
    • /
    • pp.949-956
    • /
    • 1994
  • In order to investigate the relationship between pore size distribution and freezing-thawing resistance of mortars, polymer-cement mortars were prepared by using styrene-butadiene rubber latex, ethylene-vinyl acetate emulsion and polyacrylic ester emulsion with various polymer-cement ratios at constant flow. From the results of the test, polymer-cement mortars had a good pore size distribution for freezing-thawing resistance compared with unmodified mortars because of having a small pore volume in the pore radius range of 103~104 $\AA$ affecting on the frost damage. And the freezing-thawing resistance of polymer-cement mortars was improved with increasing polymer-cement ratio.

  • PDF