• Title/Summary/Keyword: friction heat

Search Result 947, Processing Time 0.028 seconds

The Development of Automatic Grease Lubricator Driven by Gear Mechanism with Controlled Operating Time (주유시간 조절이 가능한 기어 메커니즘 구동방식의 자동그리스주유기 개발)

  • Wang, Duck-Hyun;Lee, Kyu-Young;Lee, Sang-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.2 s.179
    • /
    • pp.199-206
    • /
    • 2006
  • Automatic grease lubricator is equipment that provides adequate amount of fresh grease constantly to the shaft and the bearings of machines. It minimizes the friction heat and reduces the friction loss of machines to the least. This research is to develop automatic grease lubricator by gear driven mechanism with controlled operation time. The ultimate design of this equipment is to lubricate an adequate amount of grease by a simple switch clicking according to the advanced set cycle. The backlash of the gear was minimized to increase the output power. To increase the power of gear mechanism, the binding frequency and the thickness of the coil were changed. To control the rotating cycles of the main shaft according to its set numbers, different resistance and chips were used to design the circuit to controls electrical signals with pulse. The body of the lubricator was analyzed by stress analysis with different constructed angle. The stress analysis for differing loading pressures applied to the exterior body of grease lubricator due to the setup angle, was found that the maximum stress was distributed over the outlet part where the grease lubricator suddenly narrowed contracts. Digital mock-up was analyzed and the rapid prototyping(RP) trial products were tested with PCB circuit and grease. The evaluation of the outlet capacity for RP trial products was conducted, because the friction caused by the outlet on the wall surface was an important factor in the operation of the equipment. Finally, the finishing process was applied to decrease the roughness of the surface to a comparable level and was able to test the performance examination for the product.

The effects of Welding Conditions on Tensile Properties of Friction Stir Lap Welded of Dissimilar Al Alloy, A6K31/A5J32 (이종 알루미늄 합금 A6K31/A5J32 겹치기 마찰교반 접합부의 인장성질에 미치는 접합조건의 영향)

  • Yoon, Tae-Jin;Kim, Sang-Ju;Song, Sang-Woo;Hong, Jae-Keun;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.29 no.2
    • /
    • pp.72-79
    • /
    • 2011
  • The scope of this investigation is to evaluate the effect of joining parameters on the microstructural features and mechanical properties of dissimilar aluminum alloys, 1mm-thickness fixing AA6K31 at the top position and fixing AA5J32 at the bottom position. The friction stir lap welds were studied under various welding conditions, rotation speed of 1000, 1250, 1500rpm and welding speed of 100, 300, 500, 700mm/min, respectively. Mechanical test has been investigated in terms of tensile shear test and hardness test. The results showed that three type nugget shapes such as onion ring, zigzag type, hooking with the void, have been observed with revolutionary pitch. All welding conditions fractured at the HAZ of top plate, A6K31 and also the strength compare with base metal of lap joints were low efficiency, 52~63%. The thickness of fractured position was decreased with the lower heat input conditions. The relationships were excellent due to linear between the effective thickness of fractured position and peak load. The fractured position was the interface between joint area and not joint area. Also the strength efficiency compared with base metal was lower than decreasing rate of thickness because the hardness was decreased at fractured position due to softened material.

Effect of Process Parameters on Friction Stir Welds on AA2219-AA2195 Dissimilar Aluminum Alloys (마찰교반접합의 공정변수가 AA2219-AA2195 이종 알루미늄 접합에 미치는 영향)

  • No, Kookil;Yoo, Joon-Tae;Yoon, Jong-Hoon;Lee, Ho-Sung
    • Korean Journal of Materials Research
    • /
    • v.27 no.6
    • /
    • pp.331-338
    • /
    • 2017
  • This study was carried out to investigate the optimum condition of a friction stir welding process for a joint of AA2219-T87 and AA2195-T8 dissimilar aluminum alloys. These alloys are known to have good cryogenic properties, and as such to be suitable for use in fuel tanks of space vehicles. The welding parameters include the travelling speed, rotation speed and rotation direction of the tool. The experiment was conducted under conditions in which the travelling speed of the tool was 120-300 mm/min and the rotation speed of the tool was 400-800 rpm. To investigate the effect of the rotation direction of the tool, the joining was performed by switching the positions of the two dissimilar alloys. After welding, the microstructure was observed and the micro-hardness were measured; non-destructive evaluation was carried out to perform tensile tests on defect-free specimens. The result was that the microstructure of the weld joint underwent dynamic recrystallization due to sufficient deformation and frictional heat. The travelling speed of the tool had little effect on the properties of the joint, but the properties of the joint varied with the rotation speed of the tool. The conditions for the best joining properties were 600 rpm and 180-240 mm/min when the AA2219-T8 alloy was on the retreating side(RS).

A study on the Application Effect of Friction Stir Processing for Enhanced Pitting Corrosion Resistance of Stainless Steel Welds in Chloride Environment (염화물 환경에서 스테인리스강 용접부의 공식저항성 향상을 위한 마찰교반공정 적용효과에 관한 연구)

  • Jong Moon Ha;Deog Nam Shim;Seung Hyun Kim
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.2
    • /
    • pp.84-92
    • /
    • 2023
  • As temporary storage facilities for spent nuclear fuels in domestic nuclear power plants are expected to be saturated, external intermediate storage facilities would be required in the future. Spent nuclear fuels are stored in metal canisters and then placed in a dry environment within concrete or metal casing for operation. In the United States, the dry storage method for spent nuclear fuels has been operated for an extended period. Based on the corrosion experiences of dry storage canisters in chloride environments, numerous studies have been conducted to reduce corrosion in welds. With the construction of intermediate storage facilities in Korea for spent nuclear fuels expected near coastal areas adjacent to nuclear power plants, there is a need for research on the corrosion occurrence of welds and mitigation methods for canisters in chloride environments. In this paper, we measured and compared the residual stresses in the Heat-Affected Zones (HAZ) after electron beam welding (EBW) and gas tungsten arc welding (GTAW) processes for candidate materials such as 304L, 316L, and duplex stainless steel(DSS). We investigated the possibility of microstructure control through the application of surface modification processes using friction stir processing (FSP). Corrosion tests on each welded specimen revealed a higher corrosion rate in EBW welds compared to GTAW. Furthermore, it was confirmed that corrosion resistance improved due to phase refinement and redistribution of precipitates when FSP was applied.

Experimental Study on Auto-Transmission Fluid Heat Exchanger for Improving Vehicle Fuel Efficiency (차량 연비개선을 위한 자동변속기유 열교환기에 대한 실험적 연구)

  • Jang, Chung-Man;Lee, Yong-Kyu;Kang, Byeong-Dong;Yoo, Jai-Suk;Lee, Jong-Hwa;Kim, Hyun-Jung;Kim, Dong-Kwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.947-954
    • /
    • 2011
  • Drive-train friction loss in a vehicle may account for 4% of its total fuel consumption loss. An ATF W/C (auto-transmission fluid warmer/cooler) plate-fin heat exchanger is a type of heat exchanger that uses metal plates to transfer heat between the auto-transmission fluid and coolant. The use of an ATF W/C heat exchanger can result in a fuel economy improvement of about 1% in vehicles. An experimental setup for testing the thermal performance of an ATF W/C plate-fin heat exchanger is developed. In this study, the influence of the ATF and coolant, flow rates, and temperature on the efficiency of an ATF W/C heat exchanger are investigated experimentally. From the experimental data, a simple correlation for predicting the efficiency of an ATF W/C heat exchanger is proposed. On the basis of this correlation, the fuel economy of a vehicle with and without an ATF W/C heat exchanger is compared by using Simulink. Finally, it is shown that the fuel economy is improved by 0.992% when an ATF W/C heat exchanger is installed in the vehicle.

Study of Heating Temperature and Quantification Conditions of Standard Water for Evaluating Hair Water Content (모발 수분 함량 평가를 위한 가열 온도와 기준 수분 정량 조건 연구)

  • Sang-Hun Song;Jangho Joo;Hyun Sub Park;Seong Kil Son;Nae-Gyu Kang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.50 no.1
    • /
    • pp.11-18
    • /
    • 2024
  • Recently, there have been attempts to claim the hair moisturizing effect for a hair care product, however there has not yet been an official evaluation method because heating temperature for hair has not been established. This study was conducted to establish a quantitative evaluation for hair water content. In order to observe the behavior of water inside hair, heat was applied to hair with various temperatures using thermogravimetric dry residue. As the heating temperature increased, the amount of moisture released from the hair increased. As a result of evaluating hair using a differential scanning calorimeter (DSC), a unique phenomenon in which a rapid endothermic reaction occurs around 75 ℃ was observed. This phenomenon was also observed in different ethnic hair. In hair that damaged the hair cuticle barrier with oxidation and heat, this rapidly rising endothermic reaction temperature occurred at 77 ℃, which was slightly higher, and 73 ℃ was observed when this hair was applied with polar oil, conditioning polymer, or keratin protein. To determine how this reaction affects the hair surface, friction test was performed using an atomic force microscope. When heated above 75 ℃, cuticle friction increased, however when heated above 90 ℃, there was no change in hair cuticle friction. Finally, it was confirmed that around 75 ℃ is the critical temperature at which desorption of water bound to the hair occurs. It is suggested that a heating temperature of 75 ℃ is the optimal temperature for detecting and quantifying the moisture content of hair, and that approximately 10% detected at 75 ℃ can be a standard value for hair moisture content.

A Study of Mixed Convection on a Flat Plate with an Unheated Starting Length (비가열부가 있는 평판에서의 혼합대류에 관한 연구)

  • 김민수;강영규;백병준;박복춘
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1304-1312
    • /
    • 1993
  • The buoyancy effects on mixed convection heat transfer over a flat plate surface with unheated starting length is reported. The governing equations are solved by a finite difference method using Patankar scheme and the solution was numerically obtained for various mixed convection parametr $Gr_{x}/Re_{x}^3$, and Prandtl number of 0.7 Local heat flux was measured by using Schilieren Interferometer. The local heat transfer results show that the presence of the unheated starting length can significantly accentuate the effects of buoyancy. The degree of accentuation of the buoyancy effects is strongly influenced by the magnitude of $Gr_{x}/Re_{x}^3$. When the parameter is larger than the order of $10^{-3}$, the contribution of natural convection to the heat transfer coefficients increased significantly due to the unheated starting length. In contrast, when $Gr_{x}/Re_{x}^3$ is smaller then about $10^{-5}$ , the buoyancy contribution is essentially unaffected by the unheated starting length. The shape of the velocity profile is also found to be highly responsive to the interaction between the buoyancy and the starting length.

The Study for the characteristics of mechanically and thermally treated PET films (기계적 및 열적 처리된 PET 필름의 특성에 관한 연구)

  • 이종영;노지영;박성수
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.11 no.5
    • /
    • pp.197-202
    • /
    • 2001
  • The influence of thermal treatment and cold drawing was investigated for poly(ethy1ene terephthalate) films fabricated with various experimental conditions. Samples were elongated at room temperature under stepwise-drawing condition with the cross-head speed kom 0.5 to 500 mrdmin in an universal tester. Stress oscillation was observed in the stress-stnin curve of the samples heat-treatd at 50, 72 and $129^{\circ}C$ for 30 min, but it was not observed in the samples heat-treatd at $83^{\circ}C$ for 30 min. Thermal analyses of the samples were carried out in differential scanning calorimeter at the heating rate df $10^{\circ}C$/min/min, and the glass transition temperature, crystallization peak, enthalpy of fusion and degree of crystallinity were measured. The dynamic mechanical analyses of the samples were also carried out in a multiplefimction internal kiction pendulum at 1 Hz with the heating rate of $1.5^{\circ}C$/min, and it was found that the elastic modulus increases in the order of non-treated, heat-treated, and elongated samples.

  • PDF

A Study on Convergence Contact Behavior of Friction Heat and Pad on Disk Brake (디스크 브레이크에서 마찰열과 패드에 작용하는 융합 접촉거동에 관한 연구)

  • Han, Seung-Chul;Lee, Bong-Gu
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.1
    • /
    • pp.283-289
    • /
    • 2018
  • In automotive disc brake systems, frictional heat is not uniformly dispersed for reasons such as heat flux and thermal deformation. The thermoelastic deformation due to the frictional heat affects the contact pressure distribution and the contact load may be concentrated on the contact portion on the the disc brake surface, resulting in thermoelastic instability. In this study, thermal analysis and thermal deformation analysis considering the contact between disk and pad occurred during braking through 3D axial symmetry model with reference to the experimental equation and Kao's analysis method of contact pressure of disk and pad. ANSYS is used to analyze the thermal and elastic instability problems occurring at the contact surface between the disk and the pad, considering both the thermal and mechanical loads. A 3D axisymmetric model with direct contact between the disk and the pad was constructed to more accurately observe the thermal behavior of the disk by observing the frictional surface temperature, thermal deformation and contact thermal stress of the disk.

A Study on Finned Tube Used in Turbo Refrigerator(III) -for Pressure Drop- (터보 냉동기용 핀 튜브에 관한 연구 (III) -압력 손실에 관하여-)

  • Han, Kyu-Il;Kim, Si-Young;Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.6 no.1
    • /
    • pp.58-76
    • /
    • 1994
  • Heat transfer and pressure drop measurements are made on low integral-fin tubes in turbulent water flow condition. The integral-fin tubes investigated in this paper are nominally 19mm in diameter. Eight tubes have been used with trapezoidally shaped integral-fins having fin density from 748 to 1654 fpm and 10, 30 grooves. Plain tube having same diameter as finned tube is also tested for comparison. Experiments are carried out using R-11 as working fluid. The refrigerant condensates at a saturation state of $30^{\circ}C$ on the outside tube surface cooled by coolant. The amount of noncondensable gases present in the test loop is reduced to a negligible value by repeated purging. For a given heat input to the boiler and given cooling water flow rate, all test data are taken on steady state. The heat transfer loop is used for testing single long tubes and cooling water is pumped from a storage tank through filters and flowmeters to the horizontal test section where it is heated by steam condensing on the outside of the tube. The pressure drop across the test section is measured by means of pressure gauge and manometer. Each tube tested is cleaned with sodium dichromate pickling solution and well rinsed with water prior to installation in the test section. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, heat transfer of finned tube is enhanced up to 4 times as that of a plain tube at constant Reynolds number and up to 2 times at constant pumping power. 2. Friction factors are up to 1.6~2.1 times those of plain tube. 3. At a given Reynolds number, Nusselt number decrease with increasing pitch to diameter. 4. The constant pumping power ratio for low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio.

  • PDF