A New Scheme for Maintaining Balanced DC Voltages in Static Var Compensator(SVC) Using Cascade Multilevel Inverter

  • Min, Wan-Ki;Min, Joon-Ki;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.561-565
    • /
    • 2001
  • This paper proposes a new switching scheme of a static var compensator(SVC) with cascade multilevel inverter which employs H-bridge inverter(HBI). To improve the un­balanced problem of the DC capacitor voltages, the rotated switching scheme of fundamental frequency is newly used. The optimized fundamental switching pattern with low switching frequency is adapted to be suitable for high application. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion(THD) low in the output voltage of multilevel inverter. The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

  • PDF

A New Control Scheme for Maintaining Balanced DC Voltages in Static Var Compensator(SVC) Using Cascade Multilevel Inverter (직렬형 멀티레벨 인버터를 사용한 무효전력보상장치의 직류전압평형을 위한 새로운 제어기법)

  • Min, Wan-Ki;Min, Joon-Ki;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.179-184
    • /
    • 2005
  • This paper examines the application of high voltage static var compensator(SVC) with cascade multilevel inverter which employs H-bridge inverter(HBI). A new switching scheme is developed for the SVC system. To improve the unbalanced problem of the DC capacitor voltages, the rotated switching scheme of fundamental frequency is newly used. The optimized fundamental switching pattern with low switching frequency is adapted to be suitable for high application. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion(THD) low in the output voltage of multilevel inverter. The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

Incoherent Frequency 12-tupling Microwave Signal Generation Scheme Based on Cascade Modulators

  • Teng, Yichao;Zhang, Pin;Xu, Xin;Zhang, Baofu
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.466-476
    • /
    • 2021
  • Frequency-multiplication technology based on microwave photonic principles can be used to generate microwave and millimeter wave signals with a wide frequency tuning range. However, the existing cascaded external modulation frequency-tupling scheme needs to ensure the phase coherence of the modulated Radio Frequency (RF) signal, while the phase modulation directly limits the frequency tuning range of the external modulation frequency multiplication. In this paper, a novel approach for generating an incoherent frequency 12-tupling signal with cascade modulation is proposed. The structure of cascaded dual-parallel Mach-Zehnder modulators can generate a frequency 12-tupling signal. The proposed structure uses no filter or phase control of the RF driving signal. Microwave photonic frequency-tupling was realized under incoherent conditions. Software simulations and experiments validated the proposed structure and proved that it can generate frequency 12-tupling microwave signals under incoherent conditions. Both the frequency range and reliability of the frequency-tupling system has been improved by the proposed structure.

Effects of Rotor-Stator Blade Count Ratio on the Unsteady Aerodynamic Characteristics of a Cascade (동익과 정익의 블레이드 개수 비가 익렬의 비정상 공기역학적 특성에 미치는 영향에 대한 수치해석적 연구)

  • Kang D. J.;Jeon H. J.
    • Journal of computational fluids engineering
    • /
    • v.6 no.3
    • /
    • pp.41-50
    • /
    • 2001
  • Effects of rotor-stator blade count ratio on the unsteady aerodynamic characteristics of a cascade was studied by using a Navier-Stokes code. Present Navier-Stokes code is a parallel code and works on a multi-cpu machine. It is based on the SIMPLE algorithm and uses QUICK scheme for convection terms and second order back difference for all temporal derivatives. Computations were carried out for two cases : case 1 is for 3 stator cascade passages subjected to two upstream wakes while case 2 is for 2 stator cascade passages subjected to three upstream wakes. Numerical solutions show that rotor-stator blade count ratio plays a significant role in the unsteady aerodynamic characteristics of the stator cascade. Case 2 shows smaller unsteady fluctuation than case 1, even if they show the same time averaged value. The smaller fluctuation of case 2 is believed due to strong interaction between unsteady vortices. The unsteady lift variation of case 2 is shown to have many high frequency fluctuations as more unsteady vortices travel around the cascade. The unsteady turbulent kinetic energy due to the upstream wake is also shown to decay faster through the cascade passage than in the free stream.

  • PDF

The Unsteady Aerodynamic Characteristics of a Cascade subjected to a upstream wake with different pitch (다른 크기의 피치를 가진 후류장에 놓인 익렬의 비정상 공기역학적 특성에 관한 수치해석적 연구)

  • Jeon, H.J.;Kang, D.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.610-615
    • /
    • 2001
  • Effects of rotor-stator blade count ratio on the unsteady aerodynamic characteristics of a cascade was studied by using a Navier-Stokes code. Present Navier-Stokes code is a parallel code and works on a multi-cpu machine. It is based on the SIMPLE algorithm and uses QUICK scheme for convection terms and second order back difference for all temporal derivatives. Computations were carried out for two cases : case 1 is for 3 stator cascade passages subjected to two upstream wakes while case 2 is for 2 stator cascade passages subjected to three upstream wakes. Numerical solutions show that rotor-stator blade count ratio plays a significant role in the unsteady aerodynamic characteristics of the stator cascade. Case 2 shows smaller unsteady fluctuation than case 1, even if they show the same time averaged value. The smaller fluctuation of case 2 is believed due to strong interaction between unsteady vortices. The unsteady lift variation of case 2 is shown to have many high frequency fluctuations as more unsteady vortices travel around the cascade. The unsteady turbulent kinetic energy due to the upstream wake is also shown to decay faster through the cascade passage than in the free stream.

  • PDF

Novel Switching Strategy of 1MVar STATCON using Cascade Multilevel Voltage Source Inverter for FACTS Application (FACTS 적용을 위한 직렬형 멀티레벨 전압형 인버터를 사용한 1MVar STATCON의 새로운 스위칭기법)

  • Min, Wan-Gi;Min, Jun-Gi;Choe, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.12
    • /
    • pp.691-700
    • /
    • 1999
  • This paper proposes a novel switching strategy of 1Mvar STATCON using cascade multilevel H-bridge inverter(HBI) for FACTS application. To control the reactive power instantaneously, the d-q dynamic system model is described and analyzed. A single pulse pattern based on the SHEM(Selective Harmonic Elimination Method) technique is determined from the look-up table to reduce the line current harmonics and a rotating fundamental frequency switching scheme is presented to adjust the DC voltage of each inverter capacitor at the same value. So the voltage unbalance problem between separately DC bus voltage is improved by using the proposed switching scheme. As a result, the presented inverter configuration not only reduces the system complexity by eliminating the isolation at the AC input side transformer but also improves the dynamic response to the step change of reactive power.

  • PDF

A New Scheme for Maintaining Balanced DC Voltages in Static Var Compensator(SVC) (직렬형 멀티레벨 인버터를 사용한 무효전력보상장치의 새로운 직류전압 평형기법)

  • Min, Wan-Ki;Min, Jun-Ki;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.144-148
    • /
    • 2003
  • This paper examines the application of high voltage static var compensator(SVC) with cascade multilevel inverter which employs H-bridge inverter(HBI). To improve the unbalanced problem of the DC capacitor voltages, the rotated switching scheme of fundamental frequency is newly used. The optimized fundamental switching pattern with low switching frequency is adapted to be suitable for high application. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion(THD) low in the output voltage of multilevel inverter. The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

  • PDF

Numerical studies of information about elastic parameter sets in non-linear elastic wavefield inversion schemes (비선형 탄성파 파동장 역산 방법에서 탄성파 변수 세트에 관한 정보의 수치적 연구)

  • Sakai, Akio
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.1
    • /
    • pp.1-18
    • /
    • 2007
  • Non-linear elastic wavefield inversion is a powerful method for estimating elastic parameters for physical constraints that determine subsurface rock and properties. Here, I introduce six elastic-wave velocity models by reconstructing elastic-wave velocity variations from real data and a 2D elastic-wave velocity model. Reflection seismic data information is often decoupled into short and long wavelength components. The local search method has difficulty in estimating the longer wavelength velocity if the starting model is far from the true model, and source frequencies are then changed from lower to higher bands (as in the 'frequency-cascade scheme') to estimate model elastic parameters. Elastic parameters are inverted at each inversion step ('simultaneous mode') with a starting model of linear P- and S-wave velocity trends with depth. Elastic parameters are also derived by inversion in three other modes - using a P- and S-wave velocity basis $('V_P\;V_S\;mode')$; P-impedance and Poisson's ratio basis $('I_P\;Poisson\;mode')$; and P- and S-impedance $('I_P\;I_S\;mode')$. Density values are updated at each elastic inversion step under three assumptions in each mode. By evaluating the accuracy of the inversion for each parameter set for elastic models, it can be concluded that there is no specific difference between the inversion results for the $V_P\;V_S$ mode and the $I_P$ Poisson mode. The same conclusion is expected for the $I_P\;I_S$ mode, too. This gives us a sound basis for full wavelength elastic wavefield inversion.

On-line Frequency Estimation Based on Cascade Adaptive Notch Filter and Application to Active Noise Control

  • Kim, Sunmin;Park, Youngjin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.81-84
    • /
    • 1998
  • For ANC systems applied to aircrafts or passenger ships, engines from which reference signals are usually measured are located so far from seats where main part of controllers are placed. It can make feedforward ANC scheme difficult to implement or very costly. Feedback ANC algorithms which do not require reference signals and use error signals alone to update the filter, are usually sensitive to measurement noise ' and impulse noise. In this paper, reference signal needed for the feedforward control is not measured directly but generated with the estimated frequencies. Cascade adaptive notch filter (ANF), which has the low computational burden, is used to implement ANC system in real time. Several ANFs of order 2 are connected in series to estimate multiple sinusoids. Computer simulations and experiments in the laboratory for verifying efficacy of the proposed algorithm are carried out.

  • PDF

멀티레벨 전압형 인버터를 사용한 무효전력보상장치

  • Min, Wan-Gi;Kim, Byeong-Cheol;Jeon, Hyeong-Seok;Kim, Hyeong-Gon;Sin, Seok-Du;Jang, Seong-Nam;Lee, Gwang-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07h
    • /
    • pp.21-25
    • /
    • 1999
  • This paper proposes a novel control strategy of SVC(Static var compensator) using cascade multilevel inverter. To control the reactive power instantaneously, the dq-dynamic system model is described and analyzed. A single pulse pattern based on the SHE(Selective Harmonic Elimination) technique is determined from the look-up table to reduce the line current harmonics and a rotating fundamental frequency switching scheme is applied to adjust the DC capacitor voltage at the scheme level. From the simulation, it is verified that this proposed control scheme make the dynamic control response of SVC fast, the current harmonics low, and the DC capacitor voltage balanced.

  • PDF