• Title/Summary/Keyword: frequency variation

Search Result 2,880, Processing Time 0.029 seconds

A Study of Frequency variable Ultrasonic Transducer for the Variation of Echo Characteristics in Reflecte Wave (반사파의 주파수 성분변화에 대응한 주파수 가변 초음파 트랜스듀서)

  • 김무준
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.40-43
    • /
    • 1997
  • It is known tat the echoes from the most objects differ from the incident pulses in amplitude and frequency .Especially, the frequency in echoes from moving target is shiftby the Doppler effect. it causes to reduce the receiving sensitivity of piezoelectric transducers that have definite band width. The electric impedance, whichis connected to the electrical terminals, notably changes the resonant frequency of a thickeness mode piezoelectric vibrator with high electromechanical doupling due to the electroelastic effect. Using this effect, we have developed a frequency controllable ultrasonic transducer which is mad eof multi-layered PZT disks to adjust to frequency shifted by Doppler effect. The characteristics of transducer can be obtained by using the equivalent circuit of transmission line model. It was confirmed experimentally that the center frequency and band width of the trasducer could be controlled by the conditions of the electrical terminals. These results coincided with theoretical results.

  • PDF

Motion of a System with Varying Stiffness/Damping Subject to Harmonic Force (변화하는 강성/감쇠를 갖는 계가 조화력을 받을 때의 운동)

  • Lee, Gun-Myung;Park, O-Cheol
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.9 s.114
    • /
    • pp.958-963
    • /
    • 2006
  • The motion of a system composed of a plate, constant springs and varying dampers is considered when the system is subject to harmonic force. Letting the frequencies of harmonic force and damper variation $f_1\;and\;f_2$, respectively, the displacement at the center of the plate has the strongest component at frequency $f_1$. The angular displacement of the plate has strong components at $f_1-f_2$ and the natural frequency of the rotational mode of the system. If these two frequencies coincide, the plate oscillates with almost single frequency and a large amplitude. These results can be applied to development of a moment shaker with low frequencies.

Motion of a System with Varying Stiffness/Damping Subject to Harmonic Force (변화하는 강성/감쇠를 갖는 계가 조화력을 받을 때의 운동)

  • Lee, Gun-Myung;Park, O-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.81-85
    • /
    • 2006
  • The motion of a system composed of a plate, constant springs and varying dampers is considered when the system is subject to harmonic force. Letting the frequencies of harmonic force and damper variation ${\Large f}_1\;and\;{\Large f}_2$, respectively, the displacement at the center of the plate has the strongest component at frequency ${\Large f}_1$. The angular displacement of the plate has strong components at ${\Large f}_1-{\Large f}_2$, and the natural frequency of the rotational mode of the system. If these two frequencies coincide, the plate oscillates with almost single frequency and a large amplitude. These results can be applied to development of a moment shatter with low frequencies.

  • PDF

Transient Analysis of Magnetodynamic Systems Using Fourier Transform and Frequency Sensitivity (푸리에 변환과 주파수 민감도를 이용한 시변자장 시스템에서의 과도상태 해석)

  • Choi, Myung-Jun;Kim, Chang-Hyun;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.64-66
    • /
    • 1998
  • This paper presents a new efficient method for transient analysis in magnetodynamic systems of linear eddy current problems. This mehtod employs the Fourier transform and the high-order frequency sensitivity of harmonic finite element method. By taking into account the time-constant of magnetodynamic system, the Fourier integral of continuous frequency is converted into the Fourier series of discrete frequency. And with the results of Fourier series expansion of converted input wave form, the responses of each sinusoids is superposed to give the total response of the magnetodynamic systems. But, if the frequency band of input wave form is broad, it takes long computational time since all responses for each sinusoids must be calculated. Therefore, the high-order frequency sensitivity method is employed to estimate the response variation to frequency. The proposed algorithm is applied to an induction heating system to validate its numerical efficiency.

  • PDF

Anatomical Variation of the Lesser Saphenous Vein

  • Hwang, So-Min;Pan, Hao-Ching;Kim, Hong-Il;Jung, Yong-Hui;Kim, Hyung-Do
    • Archives of Reconstructive Microsurgery
    • /
    • v.22 no.2
    • /
    • pp.48-51
    • /
    • 2013
  • Purpose: The lessor saphenous vein is an anatomical index in various surgical methods involving an approach to the popliteal fossa. However, occasionally, there have been some cases where the surgical process was difficult because the lessor saphenous vein was not found in the popliteal fossa during the operation process. The aim of this study is to determine the frequency of the anatomical variation of lessor saphenous vein not found in the popliteal fossa with a review of the literature. Materials and Methods: This study was conducted on 83 cases of selective neurectomy for hypertrophic calf performed in our clinic from March 1997 to June 2013. There were 42 patients, with a mean age of 32.8 years old. We confirmed the existence of the lessor saphenous vein in the popliteal fossa during the operation process. Results: Among 83 cases during this study period, the lesser saphenous vein was not found in four cases. In one patient, no lesser saphenous vein was found on either side of the popliteal fossa, and in two patients, no lesser saphenous vein was found on the left side of the popliteal fossa. As a result, the frequency of variation was found to be 4.8%. Conclusion: Due to the anatomical variation of the lessor saphenous vein, it may not be found in the midline of the popliteal fossa. Based on the literature review, several possibilities for failure to observe the lesser saphenous vein could be suggested. If surgeons are well aware of these possibilities, the steadier operation could be performed.

  • PDF

Study on the Plasma Oscillation for Gas Chromatographic detector (플라즈마진동을 이용한 기체크로마토그래프의 검출기에 대한 연구)

  • Kim, Hyo Jin;Mang, Dae Young;Kang, Jong Seong
    • Analytical Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.369-374
    • /
    • 1993
  • Plasma oscillation has been observed during the development of the glow discharge as detector for gas chromatography. The variation of oscillation frequency shows the better stability and detection limits than the changes in the dischange curent. To investigate the range of useful operating conditions and to gain insight into the mechanism, the effect of experimental parameters on plasma oscillation have been studied. This study includes the variation of discharge current, pressure and discharge gap. Frequency ranges of 10KHz to 10MHz have been observed with the various shapes of oscillation. Two kinds of mode for oscillation are observed with the variation of electrode gap at low pressure and low voltage.

  • PDF

Characteristic Study of Breath-holding (지식(止息)호흡에 대한 인체의 특성연구)

  • Yoo, Seung-Yeon;Oh, Hwan-Sup;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.1
    • /
    • pp.95-110
    • /
    • 2011
  • Objectives: The aim of the present study is to define breath-holding in spontaneous respiration and to observe the difference of respiratory variables, EEG and HRV. Methods: 46 healthy young volunteers (M:F=31:15) were recruited in the study. By measuring and analysing respiration, EEG and HRV in the spontaneous respiration. We segment subjects by 100% of coefficient of variation in the breath-holding. Results & Conclusions: 1. There is a period of breath-holding after expiration and before endeavored inspiration, in the course of respiration. The greater coefficient of variation in the breath-holding, longer respiration period mean, inspiration period mean and breath-holding mean in respiratory variable. 2. There was no significant difference between HRV parameters. 3. The greater coefficient of variation in the breath-holding, the higher ${\beta}$ frequency and ${\gamma}$ frequency in the left prefrontal lobe.

Process-Variation-Adaptive Charge Pump Circuit using NEM (Nano-Electro-Mechanical) Relays for Low Power Consumption and High Power Efficiency

  • Byeon, Sangdon;Shin, Sanghak;Song, Jae-Sang;Truong, Son Ngoc;Mo, Hyun-Sun;Lee, Seongsoo;Min, Kyeong-Sik
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.5
    • /
    • pp.563-569
    • /
    • 2015
  • For some low-frequency applications such as power-related circuits, NEM relays have been known to show better performance than MOSFETs. For example, in a step-down charge pump circuit, the NEM relays showed much smaller layout area and better energy efficiency than MOSFETs. However, severe process variations of NEM relays hinder them from being widely used in various low-frequency applications. To mitigate the process-variation problems of NEM relays, in this paper, a new NEM-relay charge pump circuit with the self-adjustment is proposed. By self-adjusting a pulse amplitude voltage according to process variations, the power consumption can be saved by 4.6%, compared to the conventional scheme without the self-adjustment. This power saving can also be helpful in improving the power efficiency of the proposed scheme. From the circuit simulation of NEM-relay charge pump circuit, the efficiency of the proposed scheme is improved better by 4.1% than the conventional.

Direct Multiple Shooting Induction of Taraxacum

  • Gou, Xiaoxia;Kim, Jae-Hak;Hong, Soon-Kwan
    • Korean Journal of Plant Resources
    • /
    • v.22 no.6
    • /
    • pp.522-527
    • /
    • 2009
  • Plants of the genus Taraxacum are well-known as a traditional herbal remedy with a long history, and they have also been extensively used as food, chemicals and cosmetics. In this study, four Taraxacum species distributed in Korea (T. mongolicum, T. officinale, T. mongolicum variation and T. officinale variation) were utilized for an efficient method for direct multiple shooting induction and regeneration, using leaf blade, transition zone, petiole and root as explants in MS media with various hormone concentration and combination. MS medium containing IAA 0.2 mg/L and TDZ 1.0 mg/L showed the highest induction frequency of all the hormone combinations. Besides, the induction of T. mongolicum variation was most effective comparing with the other three species by the average induction frequency of four explants. While the induction effect of leaf blade explant was more obvious than the other three explants. This system exhibited a rapid propagation of shoots from the leaf blade explants and makes it convenient to make use of these Taraxacum species to develop their diverse applications in the future.

Implementation of the CC/CV Charge of the Wireless Power Transfer System for Electric Vehicle Battery Charge Applications (전기 자동차 배터리 충전 애플리케이션을 위한 무선 전력 전송 시스템의 CC/CV 충전의 구현)

  • Vu, Van-Binh;Tran, Duc-Hung;Pham, Van-Long;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.25-26
    • /
    • 2015
  • Inductive Power Transfer (IPT) method becomes more and more popular for the Electric Vehicle (EV) battery charger due to its convenience and safety in comparison with plugged-in charger. In recent years, Lithium batteries are increasingly used in EVs and Constant Current/Constant Voltage (CC/CV) charge needs to be adopted for the high efficiency charge. However, it is not easy to design the IPT Battery Charger which can charge the battery with CC/CV charge under the wide range of load variation due to the wide range of variation in its operating frequency. This paper propose a new design and control method which makes it possible to implement the CC/CV mode charge with minimum frequency variation (less than 1kHz) during all over the charge process. A 6.6kW prototype charge has been implemented and 96.1% efficiency was achieved with 20cm air gap between the coils.

  • PDF