• 제목/요약/키워드: frequency shifts

검색결과 177건 처리시간 0.025초

Effect of Center Frequency Deviation in Miniaturized CMOS Bandpass Filter

  • Kang, In-Ho;Li, Shang-Ming;Guan, Xin
    • 한국항해항만학회지
    • /
    • 제35권4호
    • /
    • pp.299-302
    • /
    • 2011
  • In this letter, the effect of quality factor on center frequency deviation in miniaturized coupled line bandpass filter (BPF) with diagonally end-shorted at their opposite sides and lumped capacitors is theoretically analyzed. The miniaturized BPF of a two-stage structure with two types of quality factors in standard CMOS process was designed and manufactured at 5.5 GHz. The die area of BPF was $1.44{\times}0.41\;mm^2$. The measured center frequency of BPF with a quality factor of 4.9 was deviated from 5.5 GHz to 4.7 GHz. The one with 14.8 was shifted to 5GHz. The theoretical and measured results validate that quality factor influences the center frequency shift of BPF.

공명기 분포에 따른 공명기 배열형 패널의 공명주파수 변화 (Resonance frequency shifts of Helmholtz resonator array panel brought by change in resonator arrangements)

  • 김상렬;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.97-100
    • /
    • 2005
  • Precise prediction of resonance frequency has been the subject of numerous papers related to Helmholtz resonator design because of its high performance at the frequency. The resonance frequency is dependent upon not only the internal dimensions of resonator but also the external boundary conditions such as the existence of other resonators in Helmholtz resonator array panel. However, the latter effect, which changes the external end correction of resonator, has not been well studied. We propose a formula to calculate the radiation impedance (or external end correction) of Helmhoitz resonator array panel. Any distance between adjacent resonators and any angle of Incidence can be allowed in the method. Numerical examples show how and how much the distance affects the resonance frequency of the panel. It is also found that the maximum absorption of the panel varies with the resonator arrangement.

  • PDF

청각장애인에 대한 주파수 전위 보청기와 일반 보청기의 효용성 비교 (Comparison of the Usefulness with Frequency Transposition Hearing System and Conventional Hearing Aids for the Deaf)

  • 한민경;이정학;김진숙
    • 음성과학
    • /
    • 제3권
    • /
    • pp.50-56
    • /
    • 1998
  • Frequency transposition (FT) hearing system was designed for individuals with little or no residual hearing at high frequencies. This device compresses and shifts the wide-band, high frequency acoustic energy where important features for speech perception are concentrated to the audible, lower range of frequencies. The usefulness of the FT system was investigated for 12 patients (7 children and 5 adults) with severe-to-profound sensorineural hearing losses compared with conventional hearing aids. Results suggest that the hearing impaired can benefit from the FT system with appropriate selection criteria and auditory (re)habilitation program.

  • PDF

Frequency Dependency of Multi-layer OLED Current Density-voltage Shift and Its Application to Digitally-driven AMOLED

  • Kim, Hyunjong;Kim, Suhwan;Hong, Yongtaek
    • Journal of the Optical Society of Korea
    • /
    • 제16권2호
    • /
    • pp.181-184
    • /
    • 2012
  • We report, for the first time, operation frequency dependence of current density-voltage ($J_{OLED}-V_{OLED}$) shift for multi-layer organic light-emitting diodes (OLEDs). When the OLEDs were electrically stressed for 21 hours with 50% duty voltage pulses at 60, 120, 240, and 360 Hz, the JOLED-VOLED shifts were suppressed by half for 360 Hz operation compared with 60 Hz operation, but with little change in emission efficiencies. This frequency dependent $J_{OLED}-V_{OLED}$ shift is believed to be commonly observed for typical multi-layer OLEDs and can be used to further improve lifetime of digitally-driven active-matrix OLED displays.

Investigation of the Finite Planar Frequency Selective Surface with Defect Patterns

  • Hong, Ic-Pyo
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1360-1364
    • /
    • 2014
  • In this paper, RCS characteristics on defect pattern of crossed dipole slot FSS having a finite size have been analyzed. To analyze RCS, we applied the electric field integral equation analysis which applies BiCGSTab algorithm with iterative method and uses RWG basis function. To verify the validity of this paper, RCS of PEC sphere has been compared to the theoretical results and FSSs with defect patterns are fabricated and measured. As defect patterns in FSS, missing one column, missing some elements, and discontinuity in surfaces are simulated and compared with the measurement results. Resonant frequency shifts in pass band and changes in bandwidth are observed. From the results, precisely predicting and designing frequency characteristics over defect patterns are essential when applying FSS structures such as FSS radomes.

Dynamic Structure of Bacteriorhodopsin Revealed by $^{13}C$ Solid-state NMR

  • Saito, Hazime;Yamaguchi, Satoru;Tuzi, Satoru
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.110-113
    • /
    • 2002
  • We demonstrate here a dynamic structure of bacteriorhodopsin (bR) as revealed by $^{13}$ C NMR studies on [3_$^{13}$ C]_,[1-$^{13}$ C]Ala- and/or Val-labeled wild type and a variety of site-directed mutants at ambient temperature. For this purpose, well-resolved (up to twelve) I$^{13}$ C NMR peaks were assigned with reference to the displacement of peaks due to the conformation-dependent I$^{13}$ C chemical shifts and reduced peak-intensities due to site-directed mutations. Revealed bR structure was not rigid as anticipated from 2D crystals of hexagonal array but a dynamically heterogeneous, undergoing a variety of local fluctuations depending upon specific site with frequency range of 10$^2$ -10$^{8}$ Hz. In particular, dynamics- dependent suppression of peaks turned out to be very sensitive to the motion of 10$^{-4}$ s and 10$^{-5}$ s interfered with frequency of magic angle spinning and proton decoupling, respectively. It is also noteworthy that such dynamic feature is strongly dependent upon the manner of 2D crystalline packing: $^{13}$ C NMR peaks of monomeric bR yielded either highly broadened or completely suppressed signals, depending upon the type of $^{13}$ C-labeled amino-acid residues.

  • PDF

임상 간호사의 교대근무 방향아 circadian rhythm 변화에 미치는 영향 (The Effect of Shift Directions of Clinical Nurses on the Circadian Rhythm)

  • 황애란;정현숙;강규숙;이규정
    • 기본간호학회지
    • /
    • 제1권1호
    • /
    • pp.77-97
    • /
    • 1994
  • The circadian system represents a temporal order which is mediated by the mutual coupling of oscillators and by the synchronizing effects of zeitgebers. It is known that well-being of man depends partly on the maintenance of this order, and that repeated or long lasting disturbances to it such as shift work will Cause harmful effects. This study was a quasi-experimental study to test the effect of shift directions for the clinical nurses on the circadian rhythm. Fourteen nurses working at the general units of Y hospital were selected according to the established criteria. Fourteen subjects were assigned to a weekly shift but the directions of shift work were phase delay first and then phase advance or vice versa. Oral temperature, total sleeping time, frequency of sleep-wake cycle, fatigue, mental performance, and physical symptom were measured during these days except holidays. The data collection period was from April 26, 1993 to July 3, 1993. MANOVA and Wilcoxon signed rank test were used for statistical analysis. The results are summarized as follows. 1. Having worked on evening and night shifts in either phase delay or phase advance schedules, temperature rhythms of shift workers were gradually adapted to the new sleep-wake cycles. A complete adaptation to work on the night shift was achieved the sixth day of the night shift in the phase delay schedule compared to the partial adaptation to the work on the night shift in the phase advance schedule. Accordingly, by putting evening shift between day and night shifts, it will be possible for circadian rhythm to adapt easily to the night shift. 2. There were differences in the total sleeping time, frequency of steep-wake cycle, fatigue, and physical symptom except for mental performance between night shift and day, evening shift. This indicates further that shift workers working on the night shift have a hard time adapting to the shift work compared to the other shifts. 3. Evaluating all the acrophases of temperature rhythm either in phase delay or phase ad-vance schedules, it was shown that night to evening shift in the phase ad-vance schedule revealed the smallest phase move. Also phase advance schedule showed poorer adaptation to shift work than phase delay schedule in connection with total sleeping time, frequency of sleep-wake cycle, fatigue, mental performance, and physical symptom. It is suggested, taken together, these findings reflect that phase delay schedule facilitated the degree of adjustment to the shift work compared to the phase advance schedule.

  • PDF

비표지 면역센서에 의한 냉장유통 식품 중 Pseudomonas aeruhinosa의 간이검출 (Detection of Pseudomonas aeruginosa with a Label-free Immunosensor from Various Cold Storage Foods)

  • 김남수;박인선;김동경
    • 한국식품위생안전성학회지
    • /
    • 제18권3호
    • /
    • pp.101-106
    • /
    • 2003
  • 냉장식품의 주요한 변패원일균으로서 저온세균인 Pseudomonas aeruhinosa를 최소 전처리한 후 신속히 검출할 수 있는 비표지 면역센서 시스템을 개발하였다. 수정결정전극상으로의 생물요소인 항체의 고정화는 이형이기능성 가교화제인 sulfosuccinimidyl 6-[3-(2-pyridyldithio)propionamido] hexanoate를 사용하여 항체를 티올화시킨 후 티올화된 항체를 화학흡착하여 행하였고, P. aeruginosa flagella에 대한 단클론항체를 사용하였을 때 다클론항체를 사용한 경우보다 센서감응이 우수한 것으로 나타났다. 항체가 고정화된 센서 chip과 flow형 quart crystal microbalance 계측 시스템을 이용하여 균 첨가 및 증균을 행한 10종의 모델시료에 대한 계측을 행하였다. 이 때, 시료자체에 의한 진동수변화가 52~89 Hz 범위인 반면 균 첨가 시에 나타난 진동수변화는 108~200 Hz이었고 증균시료에 의한 진동수변화는 162~222 Hz 범위로 나타났다. 시스템 안정화, 시료주입 및 정상상태이 센서반응 획득, 시스템 세척으로 이루어지는 한 주기의 센서계측에 소요된 시간은 모든 시료에 있어 30분 이내였다.

등척성 운동시 운동강도에 따른 중앙주파수의 특성 (Characteristics of Median Frequency According to the Load During Fatiguing Isometric Exercise)

  • 이수영;신화경;조상현
    • 한국전문물리치료학회지
    • /
    • 제10권3호
    • /
    • pp.141-149
    • /
    • 2003
  • Median frequency can be regarded as a valid indicator of local muscle fatigue. As local muscle fatigue develops, the muscle fiber conduction velocity decreases, the fast twitch fibers are recruited less, and consequently the median frequency shifts toward the lower frequency area. The aim of this study was to test the characteristics of the median frequency according to exercise load (30% and 60% of MVC on the biceps brachii, 40% and 80% of MVC on the vastus lateralis) during the fatiguing isometric exercise. Thirteen healthy male volunteer students of Yonsei University were recruited. After the testing maximal voluntary isometric contraction, three variables (initial median frequency, regression slope, fatigue index) from the regression line of MDF data were measured in each exercise load. The results showed that the regression slope and fatigue index were significantly different for the biceps brachii, but not for the vastus lateralis initial MDF was not significant difference according to the exercise load on both muscles. The regression slope and fatigue index could monitor physiologic muscle change during fatiguing isometric exercise. The results showed that two MDF variables reflect the local muscle fatigue according to the exercise load.

  • PDF

The Relationship Between Frequency of Injuries and Workplace Environment in Korea: Focus on Shift Work and Workplace Environmental Factors

  • Kim, Jongwoo
    • Safety and Health at Work
    • /
    • 제9권4호
    • /
    • pp.421-426
    • /
    • 2018
  • Background: The purpose of this study was to investigate the effect of shift work on occupational safety in various industrial sectors. The study analyzes the effects of shift work on the health of workers by considering factors such as the workplace environment and welfare. Methods: Focusing on the $4^{th}$ Korean Working Conditions Survey, this study used an ordinary least-square multiple regression analysis. The dependent variable was the annual frequency of injuries reported by workers. Independent variables were categorized as demographic, shift work, workplace environment, and welfare variables. The analysis was conducted on two levels: 1) Shift work and nonshift work groups were compared, and 2) Shift work was compared with fixed and rotating shifts. Results: For the entire group, age, a low level of education, work hours, and daily and dispatch work negatively impacted the frequency of injuries. Shift work was negatively affected by workplace environment and welfare factors. In the shift group, the frequency of injuries was lower than that of regular workers, and the higher the autonomy in the choice of work hours, the lower the frequency of injuries. Furthermore, shift workers in Korea have more extended work hours (49.25 h/week) than other workers (46.34 h/week). Conclusion: Overall, welfare factors such as workplace satisfaction and worke-life balance reduced the frequency of injuries. The effect of shift work was limited, but it was confirmed that shift worker autonomy could reduce the frequency of injuries.