• Title/Summary/Keyword: frequency of use

Search Result 6,757, Processing Time 0.033 seconds

A Study on Data Transmission Using Dual Frequency (Dual 주파수를 이용한 Data 전송에 관한 연구)

  • Lee, Jin;Park, Sung Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.398-402
    • /
    • 2018
  • The following conclusions were obtained after analyzing the data transmission characteristics using two frequencies and studying a system that selects data with a good reception frequency as a priority data. Data transmission and reception using two frequencies were measured at -41 to -51 dBm when the frequency was normal, and data transmitted at 900 MHz was selected as priority data. When priority frequency failure occurred, the frequency reception data of the next rank was automatically adopted, and when the frequency of the next rank was disturbed, the priority frequency search was performed again. The above results show that the use of two frequencies enables more stable data transmission and transmission, and further studies should be continued to expand the transmission and reception distances.

Continuous Variable Regression Analysis for Frequency of Damage Analysis in Heat Pipe (연속형 변수 회귀분석을 통한 열수송관 파손빈도 분석)

  • Myeongsik Kong;Jaemo Kang;Sungyeol Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.47-52
    • /
    • 2023
  • In order to efficiently maintain heat pipes operated by district heating operators, the facility history and damage history data built by the operator are used to identify key independent variables that are related to the occurrence of damage. Afterwards, the correlation with the frequency of damage was analyzed, and a basic model for estimating the frequency of damage was derived. Considering the correlation with the estimation model based on the use time currently being used by domestic and foreign district heating operators, a simple regression analysis basic model was presented as the independent variable with the highest correlation between continuous variables such as the use time, pipe diameter, burial depth, and insulation level of monitoring system, and the frequency of damage. The remaining independent variables were reflected as factors that modify and supplement the basic model. As a result of the analysis, as in previous research cases, it was confirmed that the analysis model between use time and frequency of damage had the highest correlation between the two variables and could be used as a basic model. Pipe diameter, burial depth, and insulation level of monitoring system information have also been confirmed to have a correlation with the frequency of damage, so they can be used as factors to supplement the basic model.

Design of the Digital Frequency Synthesizer for High Speed Frequency Hopping by the DDS Method using CPLD (CPLD 소자를 사용한 DDS 방식의 고속 주파수 호핑용 디지털 주파수 합성기의 설계)

  • Kim Girae;Choi Youngkyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.2
    • /
    • pp.402-407
    • /
    • 2005
  • The PLL synthesizer is used in communication system until now because it have several merits, such as broad bandwidth, high accuracy and stability of frequency But it is difficult to use in the third generation mobile communication systems that need frequency hopping at a high speed because of its long frequency hopping time. In this paper, we designed the frequency synthesizer that generate frequencies randomly at a high speed using the DDS technology.

The Design and Implementation of S/W Packet Modem based on Frequency Hopping Legacy Radio System (재래식 주파수도약 통신장비용 S/W 패킷모뎀 개발 및 적용에 관한 연구)

  • Koo, Jung;Pyo, Sang-Ho;Kang, Kyeong-Sung;Kim, Ki-Hyung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.222-231
    • /
    • 2011
  • In this paper, we have proposed a method which can make it possible to stably transmit and receive data like the ARC-164 radio frequency hopping environment as a S/W packet modem with PSK modulation. This is a method that the S/W packet modem with PSK digital modulation and the use of PC sound cards change over from data to voice signals and then transmit/receive data. We confirmed not only that it is possible to solve the slow speed communication with the use of sending data through multi-channels and PSK modulation that has the ability to methodically improve transmission rates, but also that it is possible to send the state of frequency hopping stably. In conclusion, we've confirmed both tactical values that though the transmission rate may be a tad slow, a state of frequency hopping of more than 94% confidence plus voice and data can be sent via radio at the same time. In this paper, the proposed S/W packet modem is only an implemented S/W component, so when we apply it to aircraft that we don't consider EMC problems with, then we have the advantage of a wider use of conventional UHF/VHF/HF radio that is possible to voice communication. If we recognize these operational requirements, we can apply for a lot of field equipment efficiently.

On the use of numerical models for validation of high frequency based damage detection methodologies

  • Aguirre, Diego A.;Montejo, Luis A.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.4
    • /
    • pp.383-397
    • /
    • 2015
  • This article identifies and addresses current limitations on the use of numerical models for validation and/or calibration of damage detection methodologies that are based on the analysis of the high frequency response of the structure to identify the occurrence of abrupt anomalies. Distributed-plasticity non-linear fiber-based models in combination with experimental data from a full-scale reinforced concrete column test are used to point out current modeling techniques limitations. It was found that the numerical model was capable of reproducing the global and local response of the structure at a wide range of inelastic demands, including the occurrences of rebar ruptures. However, when abrupt sudden damage occurs, like rebar fracture, a high frequency pulse is detected in the accelerations recorded in the structure that the numerical model is incapable of reproducing. Since the occurrence of such pulse is fundamental on the detection of damage, it is proposed to add this effect to the simulated response before it is used for validation purposes.

Utility AC Frequency to High Frequency ACPower Conversion Circuit with Soft Switching PWM Strategy

  • Sugimura Hisayuki;Ahmed Nabil A.;Ahmed Tarek;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.181-188
    • /
    • 2005
  • In this paper, a DC smoothing filterless soft switching pulse modulated high frequency AC power conversion circuit connected to utility. frequency AC power source is proposed for consumer induction heating hot water producer, steamer and super heated steamer. The operating principle of DC link filterless utility frequency AC-high frequency AC (HF AC) power conversion circuit defined as high frequency cycloinverter is described, which can operate under a principle of ZVS/AVT and power regulation based on alternate asymmetrical PWM in synchronization with the utility frequency single phase AC positive or negative half wave voltage. The dual mode modulation control scheme based on high frequency PWM and commercial frequency AC voltage PDM for the proposed high frequency cycloinverter are discussed to enlarge its soft switching commutation operating range for wide HF AC power regulation. This high frequency cycloinverter is developed for high frequency IH Dual Packs Heater (DPH) type boiler used in consumer and industrial fluid pipeline systems. Based on the experiment and simulation results, this high frequency cycloinverter is proved to be suitable for the consumer use IH-DPH boiler and hot water producers. The cycloinverter power regulation and power conversion efficiency characteristics are evaluated and discussed.

Dynamic Analysis of Mechanical Joint Parameters Using the Variation of Frequency Response Function (주파수응답함수의 변화를 이용한 기계적 결합부의 동특성 파라미터 해석)

  • 강성구;지태한;유원희;박영필
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.155-161
    • /
    • 1994
  • The dynamic behavior of a complex mechanical structure can be identified by dividing the structure into a series of smaller structure, called sub- structure and by studying the dynamic characteristics of these components. Generally, the dynamic characteristics of mechanical structure are strongly affected by the properties of joint parameters. In this paper, to identify the dynamic characteristics of mechanical structure, and experimental identification method in which directrly measured frequency response function(FRF) is used is considered. The method does not use the procedure of complex matrix calculation but use that of real matrix calculation. To confirm this method, computer simulation is performed by using frequency response function mixed with noise, and the experimental study is performed about the simple structure. The dynamic characteristics of joint parameters and identified more accurately than in using the prcedure of complex matrix calculation.

  • PDF

Frequency Response Based Multi-Objective Design Toolbox for PID Controller (PID 제어기의 주파수응답 기반 다목적 설계도구)

  • Jin, Lihua;Lim, Yeon-Soo;Kim, Young-Chol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1869-1875
    • /
    • 2008
  • Recently, a direct data-driven synthesis of a proportional integral derivative(PID) controller for a linear time-invariant(LTI) plant was presented in [1]. The authors showed that a complete set of PID controllers achieving robust performance and stability can be calculated directly from frequency response(FR) data without an identified transfer function model. However, it is not convenient to use this method because it requires complicated numerical algorithms to find specific frequencies which are solutions of an identical equation. The method also requires determination of the boundary of the controller's parameters from a finite set of FR data. In this paper, we present the development of a user-friendly Matlab toolbox based on the method in [1]. This toolbox allows us to obtain a complete three-dimensional(3-D) graphical solution of PID controllers that meet multiple design objectives. Several examples are given to demonstrate the use of the toolbox.

The Effects of Hand-Arm Vibration on Flexor and Extensor Fatigue (전완(前腕)의 국부(局部) 진동(振動)이 작업자의 굴근(屈筋) 및 신근(伸筋) 피로(疲勞)에 미치는 영향)

  • Lee, Dong-Chun;Kim, Gil-Ju
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.55-69
    • /
    • 1999
  • It is very common to use the powered hand tools to enhance the productivity in various types of industry. But the use of the powered hand tools could cause health problems such as cumulative trauma disorders and vibration white fingers. In this study. the effects of hand-arm vibration and anatomical hand position on localized muscle fatigue were analyzed. Eight healthy male subjects volunteered for the study. Vibration frequencies of 0, 40, 80, 100, 150, and 200Hz and hand position of flexion and ulnar deviation were selected for the independent variables of the experiment. Median frequency shifting was used as a dependent variable. The results indicated that at the vibration frequency of 40Hz and accelation of 2g, the muscle fatigue was the greatest. For the hand position. there was significant difference between neutral and flexion. and neutral and ulnar deviation, but no difference between flexion and ulnar deviation. These results could be applied in designing powered hand tools to minimize the health problems.

  • PDF

Frequency of Humidifier and Humidifier Disinfectant Usage in Gyeonggi Provine

  • Jeon, Byoung-Hak;Park, Young-Joon
    • Environmental Analysis Health and Toxicology
    • /
    • v.27
    • /
    • pp.2.1-2.4
    • /
    • 2012
  • Objectives: This study is a cross-sectional study to investigate the frequency of humidifier and humidifier disinfectant usage in the general population. Methods: A questionnaire was applied to 94 subjects (46 male, 48 female) from the general population of Gyeonggi Province. The questionnaire consisted of 3 scales (general characteristics, 5 items about humidifier usage, 5 items about humidifier disinfectant usage). Results: Thirty-five (37.2%) of the 94 subjects use a humidifier and humidifier disinfectant usage was found to be 18.1%. The frequency of humidifier usage is 4.8 times per a week and the humidifier disinfectant usage is 2.4 times per a week. Humidifier usage rate was highest in January. and then tended to rise gradually from October. Conclusions: Although this study population was not representative, we can say that approximately 50 percent of the humidifier users use a humidifier disinfectant and the trend of using a humidifier has shown seasonality.