• 제목/요약/키워드: frequency measurement

검색결과 4,257건 처리시간 0.031초

측정조건에 따른 진원도 측정오차에 대한 연구 (A study on roundness measurement errors according to measurement conditions)

  • 정현석;홍청민;최지선
    • Design & Manufacturing
    • /
    • 제13권4호
    • /
    • pp.51-56
    • /
    • 2019
  • Due to industrial development, the importance of GD&T tolerance is growing day by day. Roundness measurement means the size deviated from the ideal circle. Roundness evaluation methods include LSCI, MZCI, MCCI, and MICI. Generally, A is used a lot at industrial evaluation. In this experiment, we studied the variations in table velocity, filter values, and detector angles, which can cause errors in roundness measurements. The measurement conditions were table speeds of 10, 30 and 60 mm/s, probe angles of 10, 20 and 30 degrees and frequency filter settings of 15, 150 and 500 upr and The number of experiments was measured 30 and the average value was chosen as a representative value. The hypothesis test showed that the p-value for the frequency filter was greater than 0.05, and the experiment rejected the null hypothesis and adopted the alternative hypothesis.

Research on Subcutaneous Pulse Shape Measurement by Near-infrared Moiré Technique

  • Chen, Ying-Yun;Liu, Zhizhen;Du, Jian;Chang, Rong-Seng
    • Journal of the Optical Society of Korea
    • /
    • 제19권2호
    • /
    • pp.123-129
    • /
    • 2015
  • A pulse is generated when the heart pumps blood into the arterial system. The heart pumps blood only when it contracts, not when it relaxes; therefore, blood enters the arterial system in a cyclical form. Artery beating is visible in some parts of the body surface, such as the radial artery of the wrist. This paper mainly uses the feature in which near-infrared spectroscopy penetrates skin to construct a non-invasive measurement system that can measure small vibration in the subcutaneous tissue of the human body, and then uses it for the pulse measurement. This measurement system uses the optical moir$\acute{e}$ principle, together with the fringe displacement made by small vibration in the subcutaneous tissue, and an image analysis program to calculate the height variation from small vibrations in the subcutaneous tissue. It completes a measurement system that records height variation with time, and that together with a fast Fourier transform (FFT) program, they can convert the pulse waveform generated by vibration (time-amplitude) to heartbeat frequency (frequency-amplitude). This is a new and non-invasive medical assistance system for measuring the pulse of the human body, with the advantages of being simple, fast, safe and objective.

관성모멘트 측정에서의 불확도 추정기법 연구 (Study on the Estimation of Measurement Uncertainty in MOI Measurement)

  • 김광로;이영신
    • 한국군사과학기술학회지
    • /
    • 제16권6호
    • /
    • pp.797-802
    • /
    • 2013
  • In this paper, using the mass/CG measurement equipment and the MOI measurement equipment developed in-house, Pitch MOI and Roll MOI of test specimen were measured and measurement uncertainties on MOI were studied. The possible factors of the measurement uncertainty that could affect accuracy of MOI measurement were mass, spring, frequency, and length measurement-related elements. The each combined standard uncertainty of pitch MOI and roll MOI was estimated from the uncertainties of the above various factors.

봉상전극 접지임피던스의 측정과 이론적 분석 (Theoretical analysis and measurement of Ground impedance of Ground rods)

  • 이복희;이태형;이수봉;엄주홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1876-1878
    • /
    • 2004
  • A systematic approach of measurement, modeling and analysis of grounding system impedance is presented. The measurement and analysis system of ground impedance is based on a computer aided technique. The ground impedances of the ground rod are considerably dependent on the frequency. The ground impedance is mainly resistive in the frequency range of 3-20 kHz. At higher frequencies, the reactive components of the ground impedances are no longer negligible and the inductance of the ground rod was found to be the core factor deciding the ground impedance. As a consequence, the equivalent circuit model based on the measured data was proposed, and the calculated results were in approximately agreement with the measured data.

  • PDF

공진 자이로의 재평형 모드 구현과 각속도 측정 실험 (Force-To-Rebalance Mode of a Resonator Gyro and Angular Rate Measurement Tests)

  • 진재현;김동국
    • 제어로봇시스템학회논문지
    • /
    • 제20권5호
    • /
    • pp.563-569
    • /
    • 2014
  • This article focuses on a hemispherical resonator gyro driven by the Coriolis effect. A hemispherical shell, called a resonator, is maintained in the resonance state by amplitude control and phase locking control. Parametric excitation has been used to control the amplitude. For rate measurement mode or FTR mode, nodal points have been kept to an amplitude of zero. Angular rate measurement has been demonstrated by rotating a resonator. Frequency mismatch between two stiffness principal axes is a major cause of low performance: vibrating pattern drift and reduced control effectiveness. This mismatch has been reduced significantly by the addition of small mass. A negative spring effect, which lowers resonance frequencies, has been verified experimentally.

Measurement of Crystal Formation in Supersaturated Solution

  • Kim, Byung-Chul;Kim, Young-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1196-1200
    • /
    • 2003
  • The degree of supersaturation is an important measure for the operation of crystallization processes, because it is directly related to the control of crystal size distribution and shape. A conventional technique utilizing solution composition and temperature has a variety of problems caused from the measurement error and the handling of analyzing samples. A monitoring system of the supersaturation using a quartz crystal sensor is proposed here, and its performance is examined applying different manipulations of coolant temperature. The experimental outcome and photographic examination indicate that the measurements of resonant frequency and resistance of the sensor can be used for the prediction of the formation and growth of solid crystal from the crystallization process. The monitoring system eliminates the intrinsic error source of the conventional system to give the improved measurement and on-line application availability.

  • PDF

동적 평균을 이용한 FM 신호의 효율적인 x-dB 대역폭 측정방법 (An Effective x-dB Bandwidth Measurement Method of FM Signals using moving Average)

  • 김영수;유익한;조병모
    • 한국전자파학회논문지
    • /
    • 제11권7호
    • /
    • pp.1233-1239
    • /
    • 2000
  • 순시주파수를 갖는 FM 신호의 대역폭을 효율적으로 측정하기 위한 방법을 제안한다. ITU-R 권고 x-dB 대역폭 추정의 문제점을 해결하기 위하여 smoothing 필터를 사용하였으며, 이는 스펙트럼 포락선의 섭동을 제거해줌으로써 기준레벨과 x-dB 차이가 되는 교차 주파수를 쉽게 정할 수 있는 장점이 있다. 시뮬레이션 결과 제안된 방법이 기존 x-dB 대역폭 측정방법보다 표본 바이러스 및 평균 제곱오차 면에서 우수한 성능을 제공함을 확인하였다.

  • PDF

펨토초 레이저의 합성파를 이용한 절대거리 측정 (Absolute Distance Measurement using Synthetic Wavelength of Femto-second Laser)

  • 김윤석;진종한;주기남;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.569-572
    • /
    • 2005
  • Technological feasibility of using recently-available femtosecond ultra short pulse lasers for advanced precision length metrology is investigated with emphasis on absolute distance measurements with $10{\mu}m$ ??resolution over extensive ranges. The idea of using femtosecond lasers for the measurement of absolute distances is based on the fact that a short pulse train is a mode-locked combination of discrete monochromatic light components spanning a wide spectral bandwidth. The synthetic wavelength is created from the repetition frequency, $f_r$ of the femtosecond laser and for more precise resolution, higher-order harmonics of the repetition frequency may be selected as the synthetic wavelength by using appropriate electronic filters.

  • PDF

동축선로 프로브를 이용한 프린트 배선 회로용 기판 재료의 주파수 및 온도 변화에 따른 유전특성 연구 (A Study on Dielectric Properties of Printed Circuit Board(PCB) Materials with Variation of Frequency and Temperature using Coaxial Air Line Probe)

  • 박종성;김종헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.187-190
    • /
    • 1998
  • In this paper a probe for the' measurement of dielectric properties of dielectric sheet materials is designed and implemented as a coaxial air line type. Using the broadband impedance method with this measurement probe the dielectric constant and loss tangent of the glass-epoxy and teflon are determined in the frequency range of 0.1 - l.O[GHz] with the temperature variation from $25[^{\circ}C]$ up to $65[^{\circ}C]$. A measured relative dielectric constant of the glass-epoxy is 4.42 and a loss tangents is 0.019 relatively, and the relative dielectric constants of teflon is 2.17 and a loss tangents is 0.002 relatively

  • PDF