• 제목/요약/키워드: frequency measurement

검색결과 4,244건 처리시간 0.033초

초음파 C-Scan을 이용한 구조용 세라믹스의 기계적 특성평가 (Evaluation of Mechanical Properties of Structural Ceramics ($Al_{2}O_{3}$) Using the High Frequency Ultrasonic C - Scan)

  • 장영권
    • 비파괴검사학회지
    • /
    • 제9권2호
    • /
    • pp.18-24
    • /
    • 1989
  • Computer-aided high frequency ultrasonic is applied to aluminum oxide(85w%, 94w%, 96w%, and 99w%) MOR(modulus of rupture) samples to evaluate mechanical properties such as density variation, pore content, elastic modulus, shear modulus, and poisson's ratio. Ultrasonic wave velocity and attenuation measurement techniques were used as an evaluator of such properties. Pulse-echo C-Scan images with different fate setting method using 50MHz center frequency 1 inch focal length transducer allows evaluation of density variation and pore content. Elastic modulus calculated with the relation of density and ultrasonic velocity. It shows good reliability as compared with resonance method. Sintered density variation of $0.025g/cm^{3}$, that is 0.6% of theoretical density in $Al_{2}O_{3}$ samples can be observed by ultrasonic velocity measurement. Attenuation measurement method qualitatively agree with 4-point fracture testing result concerning of porosity content.

  • PDF

생체 임피던스 계측 방법의 구현에 관한 연구 (A Study on an Implementation of Bioelectric Impedance Instrumentation)

  • 김홍석;박세화
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.247-247
    • /
    • 2000
  • A new bioelectric impedance measurement method is proposed for the precise measurement of the bioelectric impedance. To obtain the impedance from the known applied a.c. current and the measured voltage signals, a frequency conversion circuit, like the mixer in heterodyne receivers, is introduced to reduce the frequency of the original current. It can be observed from several lines of derivation that the impedance is independent on the amplitude and phase of the mixing signals. This makes it possible to use low-speed analog-to-digital converters and thus utilize cheaper electronic parts in the implementation. The possibility of the method is shown by simulations, and a generic structure applicable to bioelectric impedance measurement devices is also proposed.

  • PDF

차량 출력 토크 측정 시스템의 시스템 식별 (System Identification of In-situ Vehicle Output Torque Measurement System)

  • 김기우
    • 한국자동차공학회논문집
    • /
    • 제20권2호
    • /
    • pp.85-89
    • /
    • 2012
  • This paper presents a study on the system identification of the in-situ output shaft torque measurement system using a non-contacting magneto-elastic torque transducer installed in a vehicle drivline. The frequency response (transfer) function (FRF) analysis is conducted to interpret the dynamic interaction between the output shaft torque and road side excitation due to the road roughness. In order to identify the frequency response function of vehicle driveline system, two power spectral density (PSD) functions of two random signals: the road roughness profile synthesized from the road roughness index equation and the stationary noise torque extracted from the original torque signal, are first estimated. System identification results show that the output torque signal can be affected by the dynamic characteristics of vehicle driveline systems, as well as the road roughness.

인체 근육에 있어서 신호 전송계수의 계측 (A measurement of signal transmission parameters in human muscle)

  • 이현철;이승주;김기영;윤재현;윤양웅;박형준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2699-2701
    • /
    • 2002
  • In this study, a system for measurement of impedance (transmission parameter) on the human muscle was constructed. The system composed of the stimulating part for input with milli-voltage and the measuring part for measurement of transmission voltage in human muscle. As a result of this experiment, the frequency characteristic of each subject represent that the transmission voltage goes up in spite of a constant input voltage according to frequency (1Hz -50kHz) increment. Namely, the amplitude of input signal was not reflected but frequency was reflected on the measured results. This result be estimated that the proposed system is able to measure passive electrical characteristic of human body.

  • PDF

임펠러 출구에서의 비정상 유동 측정 기법 (Measurement Techniques on Unsteady Flow at Impeller Exit)

  • 신유환;김광호
    • 한국유체기계학회 논문집
    • /
    • 제2권1호
    • /
    • pp.81-87
    • /
    • 1999
  • This study presents the measurement techniques on the periodic fluctuating flow such as the discharge flow of a centrifugal impeller in an unstable operating region. During rotating stall, the flow at the exit of a centrifugal compressor impeller fluctuates periodically with a lower frequency than that of the blade passing. To observe the blade-to-blade flow characteristics during the rotating stall, the phases of all the sampled data sets should be adjusted to those of the reference signals with two processes, in these processes, DPLEAT (Double Phase-Locked Ensemble Averaging Technique) can be used. From these measurements and data processing techniques, the characteristics illustrated a blade-to-blade flow with high frequency, but also a periodic rotating stall flow with a low frequency at the centrifugal impeller exit which was clearly observed.

  • PDF

합곡혈(合谷穴)에서의 임피던스 특성에 관한 연구 (A study on the characteristics of impedance on Acupoint Hapkok(LI-4, 合谷))

  • 이재원;안상우
    • 한국한의학연구원논문집
    • /
    • 제4권1호통권4호
    • /
    • pp.139-148
    • /
    • 1998
  • Measurement of different skin parameters are widely used in the practices and researches of the modern acupuncture. The most important parameter is conductance or impedance. For measurement, some researchers used D.C. and others used A.C. It has been experimentally shown that the acupuncture points and meridian lines have the characteristics of high potential, low electrical resistance, high capacitance, spontaneous sound production, spontaneous light production, and high temperature. The Purpose of this study was to examine the effect of Hapkok(LI-4, 合谷) on experimental frequency characteristics in Hapkok. The result of data analyses indicated that significant differences arise at frequency under 100Hz. We propose that development of Meridian detecting system or Meridian diagnosis system should be done using frequency under 100Hz.

  • PDF

옥내 전력선 통신 채널 임피던스 측정 장치 설계 (Design of Channel Impedance Measurement Equipment for Indoor Power Line Communications)

  • 허윤석
    • 정보학연구
    • /
    • 제8권3호
    • /
    • pp.25-33
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency 30khz$\sim$1Mhz band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

  • PDF

Investigation of Typhoon Wind Speed Records on Top of a Group of Buildings

  • Liu, Min;Hui, Yi;Li, Zhengnong;Yuan, Ding
    • 국제초고층학회논문집
    • /
    • 제8권4호
    • /
    • pp.313-324
    • /
    • 2019
  • This paper presents the analysis of wind speeds data measured on top of three neighboring high-rise buildings close to a beach in Xiamen city, China, during Typhoon "Usagi" 2013. Wind tunnel simulation was carried out to validate the field measurement results. Turbulence intensity, turbulence integral scale, power spectrum and cross correlation of recorded wind speed were studied in details. The low frequency trend component of the typhoon speed was also discussed. The field measurement results show turbulence intensity has strong dependence to the wind speed, upwind terrain and even the relative location to the Typhoon center. The low frequency fluctuation could severely affect the characteristics of wind. Cross correlation of the measured wind speeds on different buildings also showed some dependence on the upwind terrain roughness. After typhoon made landfall, the spatial correlation of wind speeds became weak with the coherence attenuating quickly in frequency domain.

고주파 수분 센서를 이용한 모르타르의 단위수량 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Unit-Water Content in Mortar Using High Frequency Moisture Sensor)

  • 조양제;유승환;양현민;윤종완;박태준;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.17-18
    • /
    • 2021
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF

FDR 센서를 통한 콘크리트 골재 변수에 따른 단위수량 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Unit-Water Content Acoording to Concrete Aggregate Variables through FDR Sensor)

  • 윤지원;유승환;양현민;윤종완;박태준;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.70-71
    • /
    • 2021
  • The unit quantity that affects the workability, shrinkage cracking, and durability of concrete is an important factor. Methods for measuring the unit quantity include a high frequency heating method, a capacitance method, a unit volume mass method, and a simple method. However, these methods have the disadvantage of poor measurement method, time required, and precision. To solve this problem, a relatively simple and fast measurement method was adopted to compensate for the shortcomings through a Frequency Domain Reflection (FDR) sensor, and the unit quantity was used. In addition, the measurement data was analyzed by deep learning to evaluate the unit quantity of concrete.

  • PDF