Study about the Standard of Anti-icing System Based on Geography and Geometric Designs (기하구조 및 지형적 요소를 고려한 융설시스템 설치 기준 정립에 관한 연구)

  • Lee, Dong-Hyun;Jeong, Won-Seok;Kim, Ji-Won;Ko, Seok-Beom
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.95-102
    • /
    • 2011
  • Anti-icing system can immediately respond when snowing is expected or the snow comes down on the road surface. It has been recognized that the system can reduce traffic accidents and congestion by quickly removing the frozen road surface area. However, it is very difficult to implement this system due to the expensive equipment installation and operation cost, Recently, there was a developed program for predicting the freezing area using three-dimensional model and tracking the sun path. But, there is no objective analysis method and all developed approaches are different so that the general standard of anti-icing system is needed. In this study, we proposed the decision criteria for determining application priorities of the anti-icing system based on weather and road conditions, i.e., geometric and topographic conditions. Regional climate survey, topographical analysis, and dynamic vehicle simulation considered road geometry and skid resistance was conducted to standardize the installation method of anti-icing system.

A Numerical Model for the Freeze-Thaw Damages in Concrete Structures

  • Cho Tae-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.857-868
    • /
    • 2005
  • This paper deals with the accumulated damage in concrete structures due to the cyclic freeze-thaw as an environmental load. The cyclic ice body nucleation and growth processes in porous systems are affected by the thermo-physical and mass transport properties, and gradients of temperature and chemical potentials. Furthermore, the diffusivity of deicing chemicals shows significantly higher value under cyclic freeze-thaw conditions. Consequently, the disintegration of concrete structures is aggravated at marine environments, higher altitudes, and northern areas. However, the properties of cyclic freeze-thaw with crack growth and diffusion of chloride ion effects are hard to be identified in tests, and there has been no analytic model for the combined degradations. The main objective is to determine the driving force and evaluate the reduced strength and stiffness by freeze-thaw. For the development of computational model of those coupled deterioration, micro-pore structure characterization, pore pressure based on the thermodynamic equilibrium, time and temperature dependent super-cooling with or without deicing salts, nonlinear-fracture constitutive relation for the evaluation of internal damage, and the effect of entrained air pores (EA) has been modeled numerically. As a result, the amount of ice volume with temperature dependent surface tensions, freezing pressure and resulting deformations, and cycle and temperature dependent pore volume has been calculated and compared with available test results. The developed computational program can be combined with DuCOM, which can calculate the early aged strength, heat of hydration, micro-pore volume, shrinkage, transportation of free water in concrete. Therefore, the developed model can be applied to evaluate those various practical degradation cases as well.

Evaluation of Therapeutic Monitoring of Prostate Cancer (PCa) using [18F]Florastamin, Diagnostic Radiopharmaceutical for PCa: Non-clinical Ex vivo Whole-body Autoradiographic Analysis

  • Min Hwan Kim;Kyongkyu Lee;Hee Seup Kil;Soon Jeong Kwon;Yong Jin Lee;Kyo Chul Lee;Dae Yoon Chi
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2023
  • In this study, we evaluated the targeting of prostate cancer (PCa) using [18F]Florastamin in non-clinical study, for the purpose of therapeutic monitoring of [177Lu]Ludotadipep, a therapeutic radiopharmaceutical for PCa, [18F]Florastamin/[177Lu]Ludotadipep was co-administered to a single-individual prostate tumor bearing mouse model, mimicking clinical condition. Considering the difference in half-life of the two isotopes (18F or 177Lu), image scan of whole-body autoradiography was performed at 24 or 48 h after preparation of frozen section, respectively. Then, it was confirmed whether they showed the same targeting efficiency for the area of tumor. A tumor xenograft model was prepared using PSMA-overexpressing PC3-PIP prostate cancer cells. [18F]Florastamin [111 MBq (3 mCi) in 100 µL]/177Lu]Ludotadipep [3.7 MBq (100 µCi) in 100 µL] was co-administered through the tail vein, and 2 hours after administration, the mice were frozen, and after freezing for 24 hours, whole-body cryosection was performed at 24 h after freezing. Image scanning using cryosection was performed after 24 or 48 hours after freezing, respectively. In the scan image after 24 hours, tumor uptake of [18F] Florastamin/[177Lu]Ludotadipep were simultaneously observed specific uptake in the tumor. In the scan image after 48 hours in the same section, signal of 18F was lost by decay of radioisotope, and specific uptake image for [177Lu]Ludotadipep was observed in the tumor. Uptake of [177Lu]Ludotadipep was specific to the same tumor region where [18F]Florastamin/[177Lu]Ludotadipep was uptake. These results suggested that [18F]Florastamin showed the same tumor uptake efficiency to PCa as [177Lu]Ludotadipep, and effective therapeutic monitoring is expected to be enable using [18F]Florastamin during [177Lu]Ludotadipep therapy for PCa.

Human Factors and Evaluation methods of Refrigerator Design (냉장고 설계의 인간요소와 인간공학적 평가방법)

  • 박재희;황민철;박세진;김명석;안영진
    • Proceedings of the ESK Conference
    • /
    • 1998.04a
    • /
    • pp.19.1-24
    • /
    • 1998
  • Designers often hesitate to decide the shape, size, and layout of a product. Though ergonomic principles and data are absolutely needed in this process, they don't have enough guidelines to refer. For the refrigerator designers, they also are not convinced of their decision: the vertical position of the freezing and refrigerating rooms, the height of shelves, the shape of door-handle, and etc. To support the refrigerator design, we applied several ergonomic methods to the evaluation of a refrigerator. EMG measurement was used to evaluate the load of user's lumbar muscle. Based upon the experimental EMG data, we developed a model to predict the relative load according to the height of refrigerator shelves. Two different layouts of a refrigerator, R/F and F/R style, were compared with the model. A three-dimenaional motion analysis method was used to evaluate the user's motion of using a refrigerator. Ten door-handles with the different shapes and positions were evaluated by tracking the rotations of the user's arm. Video protocol analysis was used to evaluate the user interface of a control panel in a refrigerator. Finally, we made several ergonomic design guidelines based on the facts found in this research and the anthropometric data of the Korean adults. The results of this study can be applied to the ergonomic design of a refrigerator.

  • PDF

Analysis of Door Height Difference and Door Flatness Difference of Built-in Side-by-Side Refrigerator Using Cabinet-Door Integrated Model (캐비닛-도어 통합모델을 이용한 빌트인 양문형 냉장고의 도어 상하단차와 앞뒤단차 해석)

  • Lee, Boo-Youn
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.76-83
    • /
    • 2018
  • A cabinet-door integrated finite element model was constructed for a built-in side-by-side refrigerator with an ice dispenser, and its deformation was analyzed using the ANSYS finite element software. As loads, the food load needed to fill in the cabinet and doors and the thermal load occurring during normal operation conditions were taken into consideration. The door height difference (DHD) and door flatness difference (DFD) between the two doors of the freezing and refrigerating compartments were derived. The DHD and DFD under the assembled condition without applied loads satisfied the acceptance criteria specified by the refrigerator manufacturer. It appeared that the food load increases the DFD slightly. The thermal load tends to increase the differences because of the thermal deformation, especially the DFD, of the cabinet and doors.

Development of Roughness-Model for Jointed Plain Concrete Pavements in Express Highway (고속도로 줄눈 콘크리트 포장의 평탄성 모델 개발)

  • Park, Young-Hoon;Chon, Beom-Jun;Kim, Young-Kyu;Lee, Seung-Woo
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Roughness is the most important factor to maintain the road performance, and affects greatly on the design life in Jointed Plain Concrete pavements. Also, the factors the evaluate pavement‘s commonality is the three method such as functionality, safety and structural performance. In evaluating function of road, representative factors is the roughness, which has been used to determine maintenance time as key standard. As research for roughness is absence in pavement design. Applied roughness-model had a low-reliability in Korea. Therefore, it is needed to develop reliable model in road roughness. In this research, uniform specific is applied to distribute them after selecting the concrete pavements. Concrete pavement is divided by sections of 238. Total length of this sections has 281km and account for 16% of total road length in korean concrete pavements for selected sections. Considering the korean roughness-model, the evaluation of roughness is performed for the freezing index, average annual rainfall, condition for the base, the amount of traffic as well as spalling(%), cracking(%), age(year) at the selected section at the selected section. Also, additional sections is selected to evaluate various age which affects on the roughness. As a result of the analysis, it showed that spalling(%), cracking(%), age(year), and the condition of the base affected road roughness. When the correlation with the road roughness was analyzed, the reliable model for road roughness was proposed, and the ratio that can explain road roughness was R2-68.8% and P value-0 which is statistically meaningful.

The Performance Simulation of All-Glass Vacuum Tubes with Coaxial Fluid Conduit (등축 유로를 가진 이중진공관형 태양열 집열기의 열성능에 관한 시뮬레이션 연구)

  • Lee, Sang-Jin;Hyun, Myung-Taek;Park, Youn-Cheol;Chun, Won-Gee;Lee, Jung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.27-38
    • /
    • 2004
  • A numerical investigation has been carried out for a solar system, which consists of all glass solar vacuum tubes Water is heated as it flows through the coaxial fluid conduit inserted in each tube. The space between the exterior of the fluid conduit and the glass tube is filled with antifreeze solution. This is to facilitate heat transfer from the solar heated absorber surface to water and to prevent the functional problems due to freezing in frigid weather conditions. A one-dimensional steady state model is fully described which will be used to develop three-dimensional model using STAR-CD. These models could be used efficiently in designing all-glass solar collector tubes with different geometrical parameters other than those considered in the present analysis. Results show good agreement when compared with other experimental data demonstrating the reliability of the present model.

A Numerical Study on the Thermal Characteristics of Double Skin Vacuum Tubes with Coaxial Fluid Conduit (등축 유로 장착 이중 태양열 진공관의 열적 특성에 관한 수치해석적 연구)

  • Hyun, Jun-Ho;Park, Youn-Cheol;Chun, Won-Gee;Lee, Sang-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.567-570
    • /
    • 2006
  • A numerical study has been carried out for a solar water heater which consists of double skin solar vacuum tubes. Water is heated as it flows through the coaxial fluid conduit inserted in each tube. The space between the exterior of the fluid conduit and the glass tube is tilled with antifreeze solution. This is to facilitate heat transfer from the solar heated absorber surface to water and to prevent the functional problems due to freezing in frigid weather conditions. A one-dimensional steady state model is fully described which will be used to develop three-dimensional model using STAR-CD. These models could be used efficiently in designing double skin solar collector tubes with different geometrical parameters other than those considered in the present analysis. Results show a good agreement when compared with other experimental data demonstrating the reliability of the one-dimensional model employed.

  • PDF

Faultproof Design in Space for Monopropellant Rocket Engine Assembly (단일추진제 로켓 엔진 어셈블리를 위한 우주 공간에서의 과실 방지 설계)

  • Han, Cho-Young;Kim, Jeong-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1377-1384
    • /
    • 2003
  • An analysis has been performed for active thermal control of the KOMPSAT monopropellant rocket engine assembly, i.e., dual thruster module(DTM). The main efforts of this work have been directed at determining proper heater sizes for propellant valves and catalyst beds necessary to maintain their temperatures within specified temperature ranges under KOMPSAT environment and operational conditions. The TAS incorporated with TRASYS thermal radiation analyzer was used to establish a complete heat transfer model which allows to predict the DTM temperature as a function of time. The thermal analysis has been performed in transient mode to verify the appropriate power for catalyst bed heaters necessary to increase catalyst bed temperature to the required value within a specified period of time. Similar analysis has been executed to validate the heater power for the thermostatically controlled primary and redundant heater circuits used to prevent hydrazine freezing, i.e., single fault. Moreover the effect of the radiative property of thermal control coating of heat shield was examined. Thruster firing condition was also simulated for the heat soakback condition. As a consequence, all thermal analysis results for DTM satisfactorily met the thermal requirements for the KOMPSAT DTM under the worst case average voltage, i.e. 25 volt.

An experimental study on occurrence of intermediate peaks in ice load signals

  • Ahn, Se-Jin;Lee, Tak-Kee
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.157-167
    • /
    • 2020
  • The purpose of this study is to analyze the relationship between the occurrence of intermediate peak and time duration, and to conduct a review for the causes of the intermediate peak. In this test, ice impact tests were conducted using a bow side shell frame and ice specimen. A total of 70 samples were manufactured. Two types of ice specimen with relatively different surface conditions were used. The criterion for dividing the two types of ice specimen was the different exposure times to room temperature after freezing. This experiment was conducted for each parameter in order to reproduce the actual icebreaking situation. As a result of the analysis, the intermediate peak in the ice load signal have been found to be caused by mechanisms by which the inner surface of broken ice contact with hull immediately after the initial hitting point of ice has been broken.