• Title/Summary/Keyword: freezing air temperature

Search Result 159, Processing Time 0.024 seconds

Field Test to Investigate Heat Transferring Effect of Carbon Fiber Heating Wire on the Concrete Slab (현장시험을 통한 Carbon fiber heating wire의 콘크리트슬래브 열전달 효과)

  • Kim, Hee Su;Ban, Hoki
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.4
    • /
    • pp.31-38
    • /
    • 2019
  • Field tests with carbon fiber heating wire (CFHW) embedded inside concrete slab were performed to present the alternative heating material capable of avoid the adverse effects of traditional de-freezing salt on the structures and environment. The CFHW was inserted into the concrete slab in the shape of 'ㄷ' to improve the heat superposition and the temperature on the surface was measured using iButton. The results showed that the temperature where the CFHW's were faced with each other increased to above zero after 12-hour at outdoor air temperature of $-6^{\circ}C$. Comparatively, the temperature slightly increased where the CFHW was embedded on one side because the heat was not superimposed. Hence, it can be said that the CFHW is a suitable heating material to prevent the concrete road from being frozen.

Establishment of Low Temperature Environment System Using Polar Environment Performance Test Construction (극지환경성능시험설비를 활용한 저온환경 시스템 구축)

  • Sung, Ki-Young;Han, Seong-Jong;Lee, Jung-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.843-851
    • /
    • 2022
  • This paper was conducted to study the conditions for the manufacture and operation of artificial snow removal and ice-making test facilities so that the test equipment can be tested in a low-temperature environment using the polar environment performance test facility. The polar environment performance test Facility is designed to artificially simulate extreme environments up to -65 ℃, and is a mid-to-large low-temperature environment test facility that can perform performance tests on offshore plant equipment, ships, leisure, and offshore structures. To verify the safety of deck work of ships operating in polar environments, artificial snow removal and artificial ice making devices were manufactured, and we conducted research on various operating environments using these facilities. For the efficient operation of artificial snow and ice making facilities, it is important to continuously supply dry air, and it has been found that installing an additional heater at the tip of the nozzle is effective in preventing freezing.

Icing Characteristics in Liquid-Phase Injection of LPG Fuel (액상분사식 LPG 인젝터의 아이싱 생성 특성 및 억제 방법)

  • Lee, Sun-Youp;Kim, Chang-Up;Choi, Kyo-Nam;Kang, Kern-Yong
    • Journal of ILASS-Korea
    • /
    • v.14 no.4
    • /
    • pp.147-152
    • /
    • 2009
  • Since a liquid-phase LPG injection system allows accurate control of fuel injection and increase in volumetric efficiency, it has advantages in achieving higher engine power and lower emissions compared to the mixer type LPG supplying system. However, this system also leads to an unexpected event called icing phenomenon which occurs when moisture in the air near the injector freezes and becomes frost around the nozzle hole due to extraction of heat from surrounding caused by instant fuel vaporization. As a result, it becomes difficult to control air/fuel ratio in engine operation, inducing exacerbation of engine performance and HC emission. One effort to mitigate icing phenomenon is to attach anti-icing injection tip in the end of nozzle. Therefore, in this study, the effect of engine operation parameters as well as surrounding conditions on icing phenomenon was investigated in a bench test rig with commercially-used anti-icing injection tips. The test results show that considerable ice was deposited on the surface near the nozzle hole of the anti-icing tip in low rpm and low load operating conditions in ambient air condition. This is because acceleration of detachment of deposited ice from the tip surface was induced in high load, high rpm conditions, resulting in decrease in frost accumulation. The results of the bench testing also demonstrate that little or no ice was formed at surrounding temperature below a freezing point since the absolute amount of moisture contained in the intake air is too small in such a low temperature.

  • PDF

Efficient Opaque Ice Sphere Formation Using a Lightweight Geometric Approach

  • Jong-Hyun Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.3
    • /
    • pp.91-98
    • /
    • 2024
  • In this paper, we present a particle-grid blending framework based on a geometric approach to efficiently represent opaque ice spheres with air bubbles. The water temperature is diffused through the grid and the air bubbles represented inside the ice through the particles. To solve the problem of previous methods that generate noisy dissolved air fields, we use levelsets to lighten the algorithm, i.e., the number of active particles and the initial amount of dissolved oxygen can be used to efficiently control the termination conditions of heat diffusion. We also extend the previous dissolved air field method, which only computes near air bubbles, to transparent regions to represent realistic ice spheres, and introduce a levelset-based approach to accurately compute the orientation of particles. As a result, the method presented in this paper is about three times faster than the existing methods and shows visually improved visualization of opaque ice spheres, which can be used in the field of representing physical virtual ice forms.

Agroclimatic Maps Augmented by a GIS Technology (디지털 농업기후도 해설)

  • Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.1
    • /
    • pp.63-73
    • /
    • 2010
  • A comprehensive mapping project for agroclimatic zoning in South Korea will end by April 2010, which has required 4 years, a billion won (ca. 0.9 million US dollars) and 22 experts from 7 institutions to complete it. The map database from this project may be categorized into primary, secondary and analytical products. The primary products are called "high definition" digital climate maps (HD-DCMs) and available through the state of the art techniques in geospatial climatology. For example, daily minimum temperature surfaces were prepared by combining the climatic normals (1971-2000 and 1981-2008) of synoptic observations with the simulated thermodynamic nature of cold air by using the raster GIS and microwave temperature profiling which can quantify effects of cold air drainage on local temperature. The spatial resolution of the gridded climate data is 30m for temperature and solar irradiance, and 270m for precipitation. The secondary products are climatic indices produced by statistical analysis of the primary products and includes extremes, sums, and probabilities of climatic events relevant to farming activities at a given grid cell. The analytical products were prepared by driving agronomic models with the HD-DCMs and dates of full bloom, the risk of freezing damage, and the fruit quality are among the examples. Because the spatial resolution of local climate information for agronomic practices exceeds the current weather service scale, HD-DCMs and the value-added products are expected to supplement the insufficient spatial resolution of official climatology. In this lecture, state of the art techniques embedded in the products, how to combine the techniques with the existing geospatial information, and agroclimatic zoning for major crops and fruits in South Korea will be provided.

Effect of supercooling and cooling rate on a continuous ice slurry formation using a plate heat exchanger (판형 열교환기에서 유동 과냉도 및 냉각속도가 연속제빙에 미치는 영향)

  • Lee, Dong-Gyu;Peck, Jong-Hyun;Hong, Hi-Ki;Kang, Chae-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.138-143
    • /
    • 2006
  • The peculiarity of ice slurry, such as liquidity, high heat transfer rate and easy storage can also find to supercooled type dynamic ice storage system(DISS) which is one of the DISS. However, in order to accomplish continuous ice formation in the system without mechanical moving parts, supercooled aqueous solutionshould be formed stable through cooling heat exchanger and be dissoluted in storage tank. In previous research, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

  • PDF

A Study on Hybrid Heating System with Anti-Superheating Devices (과열방지장치가 설치된 복합열원 난방시스템에 관한 연구)

  • Park, Youn-Cheol;Ko, Gwang-Soo;Han, Yu-Ry
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.19-27
    • /
    • 2007
  • The previous study was conducted to develop an air source multi heat pump system that could be operated with the solar collector and air source heat exchangers as heat source of the system. There is a winter-sowing problems in air source multi heat pump system when the outdoor temperature goes down under freezing point. The winter-sowing problem was solved by adapting R-22 refrigerant as working fluid in the previous study. However, when the system operated at high temperature, another problems are come out such as overheating of the solar collector outlet which lead to the superheat of the compressor inlet of the heat pump system. The condition could deteriorates a compressor in some case. In this study, we installed the anti-superheating devices on the previously developed system. As results of system performance test, COP of the system with anti-superheating technique is 2.4. It is a little improved COP compare to previous study's 2.23. In the results of multi heat source heating system, during operating solar collector, COP is relatively high between $200\;W/m^2$ and $400\;W/m^2$ solar intensity. It is recommended to extend the study on performance optimization with balancing the solar collect and capacity of compressor at higher solar irradiation conditions.

Performance of a Refrigerant Heating Type Heat Pump by Changing of Driving Devices and Heat Exchangers (구동장치 및 열교환기 변경에 따른 냉매가열식 열펌프의 성능특성)

  • Park, Youn-Cheol;Kim, Sang-Hyuk;Kim, Ji-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.49-56
    • /
    • 2008
  • When the outdoor air temperature decreased less than the freezing temperature, frost forms at the surface of heat exchangers and it makes the performance degradation of a heat pump system. In this study, a heat pump system has been developed which has a refrigerant heating device as an auxiliarly heating equipment. To reduce power consumptions of the system, a liquid pump, rather than a compressor, was used to drive refrigerant in the heat pump cycle. Ratio of refrigerant mass flow between a refrigerant heating heat exchanger(GHX) and a outdoor plate heat exchanger(PHX) was varied and the system performance was measured and analyzed. As results, when the refrigerant flow rate to the GHX was decreased, the system performance is decreased due to heat absorption capability restriction of the GHX and small variation of the power consumption in the compressor. The effect on the evaporating and condensing pressure by the distribution ratio of the refrigerant to the each heat exchanger is small compare to the effect by the frequency change in the compressor. When the compressor was replaced by the liquid pump, the capacity of the system decreased a little, however the power consumption decrease approximately 80% compare with the power used in the compressor.

Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System (수막재배 단동비닐하우스의 태양열 축열이용 효과분석)

  • Lee, S.H.;Ryou, Y.S.;Moon, J.P.;Yun, N.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF

A Fundamental Study on the Effectiveness of Anti-freeze Agent Using Waste Coolant in Cold Weather Concreting (한중콘크리트에 있어서 폐부동액을 이용한 내한제의 효율성에 관한 기초적 연구)

  • Kim, Kyoung-Min;Won, Cheol;Kim, Gi-Cheol;Oh, Sun-Kyo;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.231-236
    • /
    • 2001
  • In this paper, tests are carried out in order to investigate the validities of anti-freeze agent, which is developed using waste coolant and existing anti-freeze agent through previous study, under various W/C and contents. According to test results, adequate dosage of developed anti-freeze agent shows positive performance in slump, air content and chloride contents in the mixture of 40% and 50% of W/C, accelerates setting time and drops the freezing temperature of concrete. Meanwhile, in the region of 30% of W/C, followings can be indicated that increasing the contents of anti-freeze agent leads to reduce fluidity, rapid setting and excessive chloride contents. Improved strength gain is shown when anti-freeze agent is used with in 8%.

  • PDF