• Title/Summary/Keyword: freezing air temperature

검색결과 159건 처리시간 0.024초

가스내장 히트파이프의 냉시동특성과 성능에 관한 연구 (A Study on the Chilling Start-up Characteristics and Performance of a Gas Loaded Heat Pipe)

  • 홍성은;강환국
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.915-922
    • /
    • 2006
  • Considering heat pipe design principles in fabrication and operational performances, water is one of the most recommended working fluids to make mid to low tempera lure heat pipes. But the conventional water heat pipes might encounter the failure in a cold start-up operation when socked at a chilling temperature lower than the freezing point. If they are subjected to a heat supply for start-up at a temperature around $-20^{\circ}C$, the rate of the vapor flow and the corresponding heat transfer from the evaporator to the condenser is so small that the vapor keeps to stick on the surface of the chilling condenser wall, forming an ice layer, resulting in a liquid deficiency in the evaporator. This kind of problems was resolved by Kang et al. in 2004 by adopting a gas loading heat pipe technology to the conventional water heat pipes. This study was conducted to examine a chilling start-up procedure of gas loading heat pipes by investigating the behaviors of heat pipe wall temperatures. And the thermal resistance of the gas loaded heat pipe that depends on the operating temperatures and heat loads was measured and examined. Two water heat pipes were designed and fabricated for the comparison of performances, one conventional and the other loaded with $N_2$ gas. They were put on start-up test at a heat supply of 30 W after having been socked at an initial temperature around $-20^{\circ}C$. It was observed that the gas loaded one had succeeded in chilling start-up operation.

상변화물질을 이용한 잠열축열조에 관한 기초 연구 - 수평원관내에서의 내향용융 및 응고열전달 실험 - (A Study of Heat Storage System with Phase Change Material - Inward Melting and Solidification in a Horizontal Cylinder -)

  • 김일겸;조남철;김준근;이채문;임장순
    • 설비공학논문집
    • /
    • 제1권4호
    • /
    • pp.319-329
    • /
    • 1989
  • Heat transfer phenomena during inward melting and solidification process of the phase change material were studied expertimentally. The phase change medium was 99% pure n-docosane paraffin ($C_{22}H_{46}$). The solid-liquid interface motion during phase change was recorded photographically. Measurements were made on the temperature, the solid-liquid interface, the melted or frozen mass and the various energy components stored or extracted from the cylinder wall. For melting, the experimental results reaffirmed the dominant role played by the conduction at an early stage, by the natural convection at longer time. For solidification, natural convection effects in the superheated liquid were modest and were confined to short freezing time. Although the latent energy is the largest contributor to the total stored or extracted energy, the aggregate sensible energies can make a significant contribution, especially at large cylinder wall superheating or subcooling, large initial phase change material subcooling or superheating.

  • PDF

대형 액상분사식 LPG엔진 인젝터의 아이싱 특성연구 (Characteristics of Icing Phenomenon on Injector in a Liquid Phase LPG Injection SI Engine)

  • 김창업;오승묵;강건용
    • 한국분무공학회지
    • /
    • 제8권2호
    • /
    • pp.1-6
    • /
    • 2003
  • The liquid phase LPG injection (LPLI) system (the third generation technology) has been considered as one of the next generation fuel supply systems for LPG vehicles, since it has a very strong potential to accomplish the higher power, higher efficiency, and lower emission characteristics than the mixer type(the second generation technology) fuel supply system However. when a liquid LPG fuel is injected into the inlet duct of an engine, a large quantity of heat is extracted due to evaporation of fuel. This leads to freezing of the moisture in the air around the outlet of a nozzle, which is called icing phenomenon. It may cause damage to the outlet nozzle of an injector or inlet valve seat. In this work, the experimental investigation of the icing phenomenon was carried out The results showed that the icing phenomenon and process were mainly affected by humidity of inlet air instead of air temperature in the inlet duel. Also, it was observed that the total ice formed around the nozzle weighs at about $150mg{\sim}260mg$ after injection for ten minutes. And some fuel species were found in the ice attached at the front side of a nozzle, while frozen ice attached at the back of a nozzle was mostly' consisted of moisture of inlet air. Therefore, some frozen ice deposit. detached from front nozzle of an injector, may cause a problem of unfavorable air fuel ratio control in the small LPLI engine.

  • PDF

전기적 열제어 시스템을 사용한 에너지 소비량 감소에 관한 연구 (A study on the saving of energy consumption load using electrical heat control system)

  • 한규일
    • 수산해양기술연구
    • /
    • 제49권1호
    • /
    • pp.58-66
    • /
    • 2013
  • Most of steam power plant in Korea are heating the feed water system to prevent freezing water flowing in the pipe in winter time. The heating system is operated whenever the ambient temperature around the power plant area below 5 degree Centigrade. But this kind of heat supplying system cause a lot of energy consuming. If we think about the method that the temperature of the each pipe is controled by attaching the temperature measuring sensor like RTD sensor and heat is supplied only when the outer surface temperature of the pipe is under 5 degree Centigrade, then we can save a plenty of energy. In this study, the computer program package for simulation is used to compare the energy consumption load of both systems. Energy saving rate is calculated for the location of Youngweol area using the data of weather station in winter season, especially the January' severe weather data is analyzed for comparison. Various convection heat transfer coefficients for the ambient air and the flowing water inside the pipe was used for the accurate calculation. And also the various initial flowing water temperature was used for the system. Steady state analysis is done previously to approximate the result before the simulation. The result shows that the temperature control system using RTD sensor represents the high energy saving effect which is more than 90% of energy saving rate. Even in the severe January weather condition, the energy saving rate is almost 60%.

2중 단동비닐하우스의 태양열 축열이용 효과 (Solar Energy Storage Effectiveness on Double Layered Single Span Plastic Greenhouse)

  • 이성현;유영선;문종필;윤남규;권진경;이수장;김경원
    • Journal of Biosystems Engineering
    • /
    • 제36권3호
    • /
    • pp.217-222
    • /
    • 2011
  • This study was carried out in order to reduce the amount of underground water which is used in the double layered single span plastic greenhouse for retaining heat. For this research, two plastic green houses of the double layered single span plastic greenhouse were installed. There was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50 cm in diameter filled with subsurface water. The surplus solar energy in the greenhouse was stored in the water in the PVC duct. Four FCUs (Fan Coil Unit), which has the capacity of 8,000 kcal per hour, were installed in the middle of the house, and a circulation motor in heat storage water tank was operated from 10:30 a.m. to 16:00 p.m. in order to circulate water between the water tank and the FCUs. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of lower than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. To prevent the water freezing, mixing antifreezing liquid in the water or operating FCU continuously was needed. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Considering the amount of water used in the house with water-curtain-heating system is 150~200 ton per day, using the system mentioned in this research showed that reducing the underground water more than 80% in order to maintain the internal temperature as the level of 5 degree celsius at the extreme temperature of minus 5 degrees celsius.

Effect of Storage Conditions and Scarification on in vitro Seed Germination in Lorathus tanakae Hosok

  • Ghimeray, Amal Kumar;Lee, Hyun Woo;Lee, Bo-Duk;Sharma, Pankaja;Shim, Ie Sung;Park, Cheol Ho
    • 한국자원식물학회지
    • /
    • 제27권3호
    • /
    • pp.263-270
    • /
    • 2014
  • Loranthus tanakae (Franch. & Sav.) is an endangered species of mistletoe, distributed in Korean peninsula. The objective of our research is to determine the effect of storage duration and conditions [air flow (AF) and air tight (AT)] at different temperatures for survivability and germination of mistletoe seeds, and also to monitor the effect of seed scarification on germination in vitro. The result revealed that the seeds stored in natural conditions (no stratification) showed highest survival rate of 100% and retained up to 93.3% even after two months of storage in natural conditions and showed higher germination percentage (90%) compare to after ripened seeds. However, the seed stored at $0^{\circ}C$ decreased the germination percentage (ranged from 63 to 73%). Therefore, it can be confirmed that mistletoe does not need after ripened treatment to promote germination. Our research also showed that the storage of L. tanaka seeds in freezing temperatures of $-20^{\circ}C$ and in room temperature for long time either in AT or AF conditions caused the loss of survival and germination rate. On the other hand, the chemical scarification (0.01N HCl incubation for 12 hrs. at $38^{\circ}C$) method was proven more effective to enhance germination percentage of L. tanakae. Regarding the temperature regime, $22^{\circ}C$ showed early germination of mistletoe seeds in vitro.

Investigation of amorphous material with ice for cold thermal storage

  • Kim, Jhongkwon;Park, Hyunjun;Bae, Junhyuk;Jeong, Sangkwon;Chang, Daejun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권1호
    • /
    • pp.40-44
    • /
    • 2019
  • This study investigates mixtures of water and cryoprotectant agents (CPAs) to store high-grade cold energy. Although water is an ideal material for a cold thermal storage (CTS) due to its high specific heat, undesirable volume expansion may cause structural stresses during freezing. The volume expansion can be alleviated by adding the CPAs to water. However, the CPA aqueous solutions not only have different thermal properties but also transit to amorphous state different from pure water. Therefore, these characteristics should be considered when using them as material of the CTS. In experiments, glycerol and dimethyl sulfoxide (DMSO) are selected as the candidate CPA. The volume expansion of the solution is measured by an in-situ strain gauge in low temperature region. The specific heat capacity of the solution is also measured by differential scanning calorimetry (DSC). Both the amount of volume expansion and the specific heat capacity of the CPA aqueous solution decrease in the case of higher concentration of CPA. These characteristics should be contemplated to select optimal aqueous solution for CTS for liquid air energy storage system (LAES). The CPA solutions have advantages of having wide temperature range to utilize the latent heat of water and higher sensible heat of the CPA. The CPA solutions which can satisfy the allowable stress of the structure are determined. Consequently, among the CPA solutions investigated, DMSO 20% w/w solution is the most suitable for the CTS.

Effects of 27.12 MHz Radio Frequency on the Rapid and Uniform Tempering of Cylindrical Frozen Pork Loin (Longissimus thoracis et lumborum)

  • Choi, Eun Ji;Park, Hae Woong;Yang, Hui Seon;Kim, Jin Se;Chun, Ho Hyun
    • 한국축산식품학회지
    • /
    • 제37권4호
    • /
    • pp.518-528
    • /
    • 2017
  • Quality characteristics of frozen cylindrical pork loin were evaluated following different tempering methods: 27.12 MHz curved-electrode radio frequency (RF) at 1000 and 1500 W, and forced-air convection (FC) or water immersion (WI) at $4^{\circ}C$ and $20^{\circ}C$. The developed RF tempering system with the newly designed curved-electrode achieved relatively uniform tempering compared to a parallel-plate RF system. FC tempering at $4^{\circ}C$ was the most time-consuming process, whereas 1500 W RF was the shortest. Pork sample drip loss, water holding capacity, color, and microbiological quality declined after WI tempering at $20^{\circ}C$. Conversely, RF tempering yielded minimal sample changes in drip loss, microstructure, color, and total aerobic bacteria counts, along with relatively uniform internal sample temperature distributions compared to those of the other tempering treatments. These results indicate that curved-electrode RF tempering could be used to provide rapid defrosting with minimal quality deterioration of cylindrical frozen meat block products.

Microencapsulation of Isoprinosine with Ethylcellulose

  • Kim, Chong-Kook;Hwang, Sung-Joo
    • Archives of Pharmacal Research
    • /
    • 제14권4호
    • /
    • pp.298-304
    • /
    • 1991
  • Isoprinosine, an antiviral agent with a bitter taste, has been clinically used up to a maximum of 4 g daily in 4-8 doses. In this investigation, isoprinosine was microencapsulated with ethylcellulose 22 cps, 50 cps and 100 cps by means of polymer deposition from cyclohexane through temperature change. Complete removal of cyclohexane from the microcapsules was necessary, since ethylcellulose-coated microcapsules obtained from cyclohexane medium were heavily solvated with cyclohexane and formed lumps even after drying. The displacement of cyclohexane by n-hexane during isolation of microcapsules (Method III) or the freezing of the anal-washed microcapsules before drying (Mothod II) provided the dried products which were more discrete microcapsules than those which were simply dried in the air overnight (Method I). Method III was especially the most effective procedure in preparing finer and more discrete microcapsules. The drug-release from microcapsules was influenced by the ratio of core to wall, the viscosity grade of ethylcellulose and the overall microcapsule size. The release rate was adequately fitted to both the first-order and the diffusion-controlled processes. It is therefore possible to design the release-controlled microcapsules with ethylcellulose of different viscosity along with various core to wall ratio.

  • PDF

미세조작된 생쥐수정란의 초급속 재동결융해 후 생존성 (Viabilities of Biopsied Mouse Embryos after Ultrarapid Refreezing and Thawing)

  • 신상태;임준호;강만종;한용만;이경광
    • 한국가축번식학회지
    • /
    • 제20권2호
    • /
    • pp.207-214
    • /
    • 1996
  • 본 연구는 미세조작된 수정란의 초급속 재동결 후 발생능을 조사하기 위해서 수행하였다. 먼저 4세포기 생쥐 수정란으로부터 할구세포 한 개를 떼어내고 이들 수정란을 동결액에 넣어 상온에서 2.5분간 평형시킨 다음, 0.25ml straws에 넣어 곧바로 액체질소에 침지시켰다. 4세포기 수정란의 동결액으로는 4.0M(ethylene glycol 및 0.25M sucrose가 함유된 dPBS를 사용하였따. 상실배기 수정란의 동결을 위해서는 항동해제로 4.0M ethylene glycol 대신에 5.0M glycerol을 사용하였다. 융해후 biopsied 4세포기 수정란을 M16 배양액에서 상실배기까지 발달시킨 다음 상실배기용 동결액을 이용하여 초급속 재동결을 실시하였다. 재동결융해 후 발달한 biopsied 배반포기 수정란을 대리모에 이식하여 이들 수정란의 생존성을 검토하였다. 제1차 동결후 biopsied 수정란의 체외발달률은 78%로서 정상적인 수정란의 발달율(91%) 보다 낮은 성적으로 보여주었으나 (P<0.01), 이들 수정란의 이식 후 임신률은 각각 25 및 30%로서 두 실험군간에 차이가 인정되지 않았다. 그리고 biopside 상실배기 수정란의 초급속 재동결후 체외 발달률 및 임신률은 각각 89와 27%로서 biopsied 되지 않은 수정란의 성적 (각각 95 및 28%)과 유사하였다. 이러한 결과를 종합하여 볼 때, 본 연구에서 사용된 초급된 재동결 과정이 미세조작된 생쥐수정란의 생존성에 영향을 미치지 않는 것으로 나타났다.

  • PDF