• Title/Summary/Keyword: free field analysis

Search Result 705, Processing Time 0.025 seconds

Antimicrobial, Antioxidant and Cellular Protective Effects against Oxidative Stress of Anemarrhena asphodeloides Bunge Extract and Fraction (지모 뿌리 추출물과 분획물의 항균활성과 항산화 활성 및 세포보호 연구)

  • Lee, Yun Ju;Song, Ba Reum;Lee, Sang Lae;Shin, Hyuk Soo;Park, Soo Nam
    • Microbiology and Biotechnology Letters
    • /
    • v.46 no.4
    • /
    • pp.360-371
    • /
    • 2018
  • Extracts and fractions of Anemarrhena asphodeloides Bunge were prepared and their physiological activities and components were analyzed. Antimicrobial activities of the ethyl acetate and aglycone fractions were $78{\mu}g/ml$ and $31{\mu}g/ml$, respectively, for Staphylococcus aureus and $156{\mu}g/ml$ and $125{\mu}g/ml$, respectively, for Pseudomonas aeruginosa. 1,1-Diphenyl-2-picrylhydrazyl free radical scavenging activities ($FSC_{50}$) of 50% ethanol extract, ethyl acetate fraction, and aglycone fraction of A. asphodeloides extracts were $146.2{\mu}g/ml$, $23.19{\mu}g/ml$, and $71.06{\mu}g/ml$, respectively. The total antioxidant capacity ($OSC_{50}$) in an $Fe^{3+}$-EDTA/hydrogen peroxide ($H_2O_2$) system were $17.5{\mu}g/ml$, $1.5{\mu}g/ml$, and $1.4{\mu}g/ml$, respectively. The cytoprotective effect (${\tau}_{50}$) in $^1O_2$-induced erythrocyte hemolysis was 181 min with $4{\mu}g/ml$ of the aglycone fraction. The ${\tau}_{50}$ of the aglycone fraction was approximately 4-times higher than that of (+)-${\alpha}$-tocopherol (${\tau}_{50}$, 41 min). Analysis of $H_2O_2$-induced damage of HaCaT cells revealed that the maximum cell viabilities for the 50% ethanol extract, ethyl acetate fraction, and aglycone fraction were 86.23%, 86.59%, and 89.70%, respectively. The aglycone fraction increased cell viability up to 11.53% at $1{\mu}g/ml$ compared to the positive control treated with $H_2O_2$. Analysis of ultraviolet B radiation-induced HaCaT cell damage revealed up to 41.77% decreased intracellular reactive oxygen species in the $2{\mu}g/ml$ aglycone fraction compared with the positive control treated with ultraviolet B radiation. The findings suggest that the extracts and fractions of A. asphodeloides Bunge have potential applications in the field of cosmetics as natural preservatives and antioxidants.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

A Study on the Compositional Characteristics of Water Systems and Landscapes in Traditional Chinese Seowons (중국 전통서원의 수체계와 수경관의 구성적 특성)

  • MA, Shuxiao;RHO, Jaehyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.3
    • /
    • pp.74-100
    • /
    • 2022
  • The purpose of this study was to investigate the characteristics of Chinese seowons and to obtain data based on the characteristics of waterscapes unique to Korean seowons. The conclusion of this study from the results of investigation and analysis of the location, water system, and design characteristics of 10 representative traditional seowons in China including Yuelu Seowon(嶽麓書院) conducted based on literature research and field observation is as follows. The water system of Chinese seowons is dualized into an inner and an outer water system, and in general, two and a maximum of three water bodies are superimposed on the outside. The locations of seowons are classified into five types: Four double-sided round water type sites, three converted face water type sites, one three-sided round water type site, a four-sided round water type, and a waterproofing type(依山傍水型). Therefore, compared to the typical Korean seowon facing water in the front and a mountain in the back(背山面水型), the Chinese seowons showed a highly hydrophilic property. The water shapes of the external water system were meandering(46.0%), mooring(36.0%), and broad and irregular(9.0%). In addition, water conception(水態) were streams(31.8%), rivers(27.3%), springs(13.6%), falls(9.1%), lakes(4.5%) and ponds(4.5%), in that order. As for waterscapes of the water system inside the seowon, there were seven in Akrok Seowon and four in Mansong Seowon, indicating a comparatively higher number of waterscapes. Since the 27 detailed waterscapes in 10 seowons that were the subject of the study were classified into six types including ponds and half-moon ponds, they appeared to be more diverse than the Korean seowon. It is noteworthy that in the interior waterscape of the traditional Chinese seowon, the ritualistic order, where at least one half-moon pond or square pond(方池) was arranged, is well displayed. In particular, the half-moon pond(伴池), which is difficult to find in Korean seowon, was found to be a representative waterscape element, accounting for 42.8%. If the square pond of Nanxi Seowon based on Zhu Xi's poem 「Gwanseoyugam(觀書有感)」 is also treated as a square-shaped half-moon pond, the proportion of half-moon ponds in the waterscape will be as high as 50%. The pond shapes consisted of 28% square, 24% each for free curve and round shape, 20% for semi-moon shape, and 3.8% for mountain stream type. This seems to differ greatly from the square-shaped Korean seowon. On the other hand, there were a total of 10 types of structures related to the waterscape inside the Chinese seowon: 11(26.8%) pavilion and bridge sites, five gate room sites(牌坊: 16.5%), four gate and tower sites(樓, 1.4%), two Jae sites(齋, 6.2%), and one site each(3.1%) of Heon(軒), Sa(祠), Dae(臺), and Gak(閣). In particular, the pavilions inside seowon were classified into three types: landscape pavilion(景觀亭 27.2%), tombstone pavilion(碑亭, 18.2%), and banquet pavilion(宴集亭, 54.5%). In general, it was confirmed that the half-moon pond with a pedestal bridge, and the pavilion were the major components with a high degree of connection that dominate the waterscape inside the Chinese seowon.

The Effects of Switching-Frustrated Situation on Negative Psychological Response (전환 좌절상황에서 소비자의 부정적 심리반응에 관한 연구)

  • Jeong, Yun Hee
    • Asia Marketing Journal
    • /
    • v.14 no.1
    • /
    • pp.131-157
    • /
    • 2012
  • Despite the voluminous research on switching barriers, the notion that they can generate negative responses has not been investigated. Further, a critical question is what determines the strength of such negative responses. To address this question, the classic theory of psychological reactance is briefly reviewed, and the idea of switching barrier is advanced. This study attempts to suggest a model on the negative effects of switching- frustrated situation, based on the studies on psychological reactance. According to psychological reactance theory(Brehm 1966), whenever a freedom is threatened or removed, individuals are motivated, at least temporarily, to restore their freedom. For example, if individuals think they are free to engage in behaviors .v, y, or z, then threatening their freedom to engage in x would cause psychological reactance. This reactance could be reduced by an increase in the perceived attractiveness of engaging in, the threatened behavior(Kivetz 2005). This investigation seeks to extend existing switching barrier research in three important ways. First, while the past research has emphasized only positive role of switching barrier, this study address negative role of it by applying psychological reactance theory. Second, to find negative results of switching barrier, I suggest negative psychological response including regret to the past choice, resentment to the present provider, and strong desire to the alternative provider. Third, I suggest the perceived severity of the switching barriers, the attractiveness of the alternative as switching-frustrated situation which can lead to negative results. And, in addition to these relationships, I added moderated effects of perceived justice for better explanation. So this study includes the following hypotheses. H1-1 ~ H1-3: The attractiveness of the alternative has a positive effect regret to the past choice (h1-1), resentment to the present provider (h1-2), and strong desire to the alternative provider (h1-3). H2-1 ~ H2-3 : The perceived severity of the switching barrier has a positive effect regret to the past choice (h2-1), resentment to the present provider (h2-2), and strong desire to the alternative provider (h2-3). H3-1 ~ H3-3 : The positive relationships between the attractiveness of the alternative and consumer' negative responses will be stronger at low level of perceived justice than at high level of perceived justice. H4-1 ~ H4-3 : The positive relationships between the perceived severity of the switching barrier and consumer' negative responses will be stronger at low level of perceived justice than at high level of perceived justice. Survey research is employed to test hypotheses involving perceived severity of the switching barrier(Hess 2008), attractiveness of the alternative(Anderson and Narus 1990; Ohanian 1990),regret(Glovich and Medvec 1995), resentment, strong desire(Alcohol Urge Questionaire: Bohn et al. 1995), perceived justice(Bies and Moag 1986; Clemmer 1993; Lind and Tyler 1998). Previous researches, such as reactance theory, emotion and service failure, have been referenced to measure constructs. All items were measured on a 7-point Likert scale ranging from "strongly disagree" to "strongly agree". We collected data involving various service field, and used 249 respondents to analyze these data using the moderated regression. The results of our analysis suggest, as expected, that the perceived severity of the switching barrier had positive effects on regret to the past choice(b = .197, p< .01), resentment to the present provider(b = .214, p< .01), and strong desire to the alternative provider(b = .254, p< .001). And the attractiveness of the alternative had positive effects on regret to the past choice(b = .353, p<.001), resentment to the present provider(b = .174, p< .01), and strong desire to the alternative provider(b = .265, p< .001). However, our findings indicate perceived justice partly moderates relationship between switching-frustrated situation and psychological negative response. The study has brought to light a number of insights between switching barriers and consumer' negative responses that have been subject to little prior research. In particular, this study adds to the existing understanding of the psychological responses to switching barriers in switching- frustrated situation. This research therefore has significance to marketers for strategic marketing programs, particularly in terms of customer retention and switching barrier strategies. Since consumers could exhibit negative responses to switching barrier, companies would be able to lose their customer when they thoughtlessly use switching barrier for remaining customer. Although the study has these contributions, there are several limitations including unsupported hypotheses and research method. So, we need to make up for these limitations in the future researches.

  • PDF

Radiation Therapy and Chemotherapy after Breast Conserving Surgery for Invasive Breast Cancer: An Intermediate Result (침윤성 유방암에서 유방보존수술 후 방사선치료 및 항암화학 병용치료의 성적 및 위험인자 분석)

  • Lee, Seok-Ho;Choi, Jin-Ho;Lee, Young-Don;Park, Heoung-Kyu;Kim, Hyun-Young;Park, Se-Hoon;Lee, Kyu-Chan
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.16-25
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Breast conserving surgery (BCS) followed by chemotherapy (CTx.) and radiation therapy (RT) is widely performed for the treatment of early breast cancer. This retrospective study was undertaken to evaluate our interim results in terms of failure patterns, survival and relative risk factors. $\underline{Materials\;and\;Methods}$: From January 1999 through December 2003, 129 patients diagnosed with invasive breast cancer and treated with BCS followed by RT were subject to retrospective review. The median age of the patients was 45 years (age distribution, $27{\sim}76$ years). The proportions of patients according to their tumor, nodes, and metastases (TNM) stage were 65 (50.4%) in stage I, 41 (31.7%) in stage IIa, 13 (10.1%) in stage IIb, 9 (7.0%) in stage III, and 1 patient (0.8%) in stage IIIc. For 32 patients (24.8%), axillary node metastasis was found after dissection. BCS consisted of quadrantectomy in 115 patients (89.1%) and lumpectomy in 14 patients (10.6%). Axillary node dissection at axillary level I and II was performed for 120 patients (93%). For 7 patients (5.4%), only sentinel node dissection was performed with BCS. For 2 patients (1.6%) axillary dissection of any type was not performed. Postoperative RT was given with 6 MV X-rays. A tumor dose of 50.4 Gy was delivered to the entire breast area using a tangential field with a wedge compensator. An aditional dose of $9{\sim}16\;Gy$ was given to the primary tumor bed areas with electron beams. In 30 patients (23.3%), RT was delivered to the supraclavicular node. Most patients had adjuvant CTx. with $4{\sim}6$ cycles of CMF (cyclophosphamide, methotrexate, 5-fluorouracil) regimens. The median follow-up period was 50 months (range: $17{\sim}93$ months). $\underline{Results}$: The actuarial 5 year survival rate (5Y-OSR) was 96.9%, and the 5 year disease free survival rate (5Y-DFSR) was 93.7%. Local recurrences were noted in 2 patients (true: 2, regional node: 1) as the first sign of recurrence at a mean time of 29.3 months after surgery. Five patients developed distant metastases as the first sign of recurrence at $6{\sim}33$ months (mean 21 months). Sites of distant metastatic sites were bone in 3 patients, liver in 1 patient and systemic lesions in 1 patient. Among the patients with distant metastatic sites, two patients died at 17 and 25 months during the follow-up period. According to stage, the 5Y-OSR was 95.5%, 100%, 84.6%, and 100% for stage I, IIa, IIb, and III respectively. The 5Y-DFSR was 96.8%, 92.7%, 76.9%, and 100% for stage I, IIa, IIb, and III respectively. Stage was the only risk factor for local recurrence based on univariate analysis. Ten stage III patients included in this analysis had a primary tumor size of less than 3 cm and had more than 4 axillary lymph node metastases. The 10 stage III patients received not only breast RT but also received posterior axillary boost RT to the supraclavicular node. During the median 53.3 months follow-up period, no any local or distant failure was found. Complications were asymptomatic radiation pneumonitis in 10 patients, symptomatic pneumonitis in 1 patient and lymphedema in 8 patients. $\underline{Conclusion}$: Although our follow up period is short, we had excellent local control and survival results and reaffirmed that BCS followed by RT and CTx. appears to be an adequate treatment method. These results also provide evidence that distant failure occurs earlier and more frequent as compared with local failure. Further studies and a longer follow-up period are needed to assess the effectiveness of BCS followed by RT for the patients with less than a 3 cm primary tumor and more than 4 axillary node metastases.