• Title/Summary/Keyword: frame difference

Search Result 777, Processing Time 0.039 seconds

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF

The Meaning of Collective Relationships Becoming by Large-scale Interview Project - Focused on the media exhibition art <70mk> - (대규모 인터뷰 작업이 생성하는 집단적 관계성의 의미 - 미디어전시예술 <70mK>를 중심으로)

  • OH, Se Hyun
    • Trans-
    • /
    • v.7
    • /
    • pp.19-48
    • /
    • 2019
  • This study was described to examine the meaning of the media exhibition work <70mK>, which aims to capture the topography of the collective consciousness of the Korean people through large-scale interviews. <70mK> edits and organizes interview images of individual beings in mosaic-like layouts and forms, creating video exhibitions and holding exhibitions. The objects in the split frame show the continuity of differences that reveal their own thoughts and personalities. This is a synchronic and conscious collective typology in which the intrinsic nature of the individuals is embodied in a simultaneous and holistic image. Interview images reveal their own form as a actual being and convey the intrinsic nature of one's own as oral information. <70mK> constructs a new individualization by aesthetically structuring the forms and information of life individuals in the extension of a specific group. The beings in the frame are not communicating with each other and are looking straight ahead. it conveys to visitors their relationship and personality as the preindividual reality. It is the repetitive arrangement and composition of heterogeneity and difference that each individual shows, and is a chain operation that includes collective identity behind it. <70mK> constructs the direct images and sounds of individual interviewee, creating a new form of information transfer called Video Art Exhibition. This makes metaphors and perceptions of the meaning and process of transindividual relationships and the meaning of psychic individuation and collective individuation. This is an appropriate case to explain with modern technology and individualization of Gilbert Simondon thought together with the meaning of becoming and relation of individualization. The exhibition space constructed by <70mK> is an aesthetic methodology of the psychic and collective meaning and its relationship to a particular group of individuals through which they are connected. Simondon studied the meaning of the process of individualization and the meaning of becoming, and is a philosopher who positively considered the potential of modern technology. <70mK> is a new individual as structured and generated ethical reality mediated by modern technology mechanisms and network behaviors. It is an case of an aesthetic and practical methodology of how interviews function as 'transduction' in the process of individualization in which technology is cooperated. The direct images and sounds of <70mK> are systems in which the information of life individuals is carried, amplified, accumulated and transmitted. It is also a new individual as a psychic and collective landscape. It is a newly became exhibition art work through the multiple individualization, and is a representation of transindividual meanings and process. The media exhibition art of individualized metastable states leads to new relationships in which viewers perceive the same preindividual reality and feel affectivity. The exhibition space of <70mK> becomes a stage for preparing the actual possibility of the transindividual group beyond the representation of the semantic function.

  • PDF

The evaluation of usefulness of Electronic Portal Imaging Device(EPID) (Electronic Portal Imaging Device(EPID)의 유용성 평가)

  • Lee, Yang-Hoon;Kim, Bo-Kyoum;Jung, Chi-Hoon;Lee, Je-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.19-31
    • /
    • 2005
  • Purpose : To supply the information of EPID system and to analyze the possibility of substitution EPID for film dosimetry. Materials & Methods : With amorphous silicon(aSi) type EPID and liquid filled lonization chamber(LC) type EPID, the reproducibility according to focus detector distance(FDD) change and gantry rotation was analyzed, and also the possible range of image acquisition was analyzed with Alderson Rando phantom. The resolution and the contrast of aSi type EPID image were analyzed through Las Vegas phantom and water phantom. DMLC image was analyzed with X-Omat V film and EPID to see wether it could be applied to the qualify assurance(QA) of IMRT. Results : The reproducibility of FDD position was within 1mm, but the reproducibility of gantry rotation was ${\pm}2,\;{\pm}3mm$ respectively. The resolution and the contrast of EPID image were affected by dose rate, image acquisition time, image acquisition method and frame number. According to the possible range of image acquisition of EPID, it is verified that the EPID is easier to use than film. There is no difference between X-Omat V film and EPID images for the QA of IMRT. Conclusion : Through various evaluation, we could obtain lots of useful information about the EPID. Because the EPID has digital data, also we found that the EPID is more useful than film dosimerty for the periodical Qualify Assurance of IMRT. Especially when it is difficult to do point dose measurement with diode or ionization chamber, the EPID could be very useful substitute. And we found that the diode and ionization chamber are difficult to evaluate the sliding window images of IMRT, but the EPID was more useful to do it.

  • PDF

Effects of Use of the Iodine Contrast Medium on Gamma Camera Imaging (요오드 조영제 사용이 감마카메라 영상에 미치는 영향)

  • Pyo, Sung-Jae;Cho, Yun-Ho;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.557-564
    • /
    • 2016
  • Effects of Gamma camera imaging on gamma ray counting rates as a function of use and density of the iodine contrast medium currently in primary use for clinics, and changes in gamma ray counting rates as a function of the contrast medium status upon attenuation correction using a CT absorption coefficient in an SPECT/CT attenuation correction will be considered herein. For experimental materials used $^{99m}TcO_4$ 370 MBq and Pamiray 370 mg, Iomeron 350 mg, Visipaque 320 mg, Bonorex 300 mg of iodine contrast medium. For image acquisition, planar imaging was consecutively filmed for 1, 2, 3, 4, 5 min, respectively, 30 min after administration of $^{99m}TcO_4$. while 60 views were filmed per frame for 20 min at 55 min for the SPECT/CT imaging. In planar imaging, the gamma ray counting rates as a function of filming time were reduced showing a statistically significant difference when mixed according to the type of contrast medium density rather than when the radioactive isotope $^{99m}TcO_4$ and the saline solution were mixed. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and saline solution, the mean counting rate without correction by the CT absorption coefficient is $182{\pm}26counts$, while the counting rate with correction by the CT absorption coefficient is $531.3{\pm}34counts$. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and the saline solution with the contrast medium, the mean values before attenuation correction by CT absorption coefficient were $166{\pm}29$, $158.3{\pm}17$, $154{\pm}36$, and $150{\pm}33counts$ depending on the densities of the contrast medium, while the mean values after attenuation correction were $515{\pm}03$, $503{\pm}10$, $496{\pm}31$, and $488.7{\pm}33counts$, showing significant differences in both cases when comparatively evaluated with the imaging for no mixing of the contrast medium. Iodine contrast medium affects the rate of gamma ray. Therefore, You should always be preceded before another test on the day of dignosis.

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Analysis on Subjective Image Quality Assessments for 4K-UHD Video Viewing Environments (4K-UHD 비디오 시청환경 특성분석을 위한 주관적 화질평가 분석)

  • Park, In-Kyung;Ha, Kwang-Sung;Kim, Mun-Churl;Cho, Suk-Hee;Cho, Jin-Soo
    • Journal of Broadcast Engineering
    • /
    • v.15 no.4
    • /
    • pp.563-581
    • /
    • 2010
  • In this paper, we perform subjective visual quality assessments on UHD video for UHD TV services and analyze the assessment results. Demands for video services have been increased with availabilities of DTV, Internet and personal media equipments. With this trend, the demands for high definition video have also been increasing. Currently, 2K-HD ($1920{\times}1080$) video have been widely consumed over DTV, DVD, digital camcoders, security cameras and other multimedia terminals in various types, and recently digital cinema contents of 4K-UHD($3840{\times}2160$) have been popularly produced and the cameras, beam projects, display panels that support for 4K-UHD video start to come out into multimedia markets. Also it is expected that 4K-UHD service will appear soon in broadcasting and telecommunications environments. Therefore, in this paper, subjective assessments of visual quality on resolutions, color formats, frame rates and compression rates have been carried to provide basis information for standardization of signal specification of UHD video and viewing environments for future UHDTV. As the analysis on the assessments, UHD video exhibits better subjective visual quality than HD by the evaluators. Also, the 4K-UHD test sequences in YUV444 shows better subjective visual quality than the 4K-UHD test sequences in YUV422 and YUV420, but there is little perceptual difference on 4K-UHD test sequences between YUV422 and YUV420 formats. For the comparison between different frame rates, 4K-UHD test sequences of 60fps gives better subjective visual quality than those of 30fps. For bit-depth comparison, HD test sequences in 10-bit depth were little differentiated from those in 8-bit depth in subject visual quality assessment. Lastly, the larger the PSNR values of the reconstructed 4K-UHD test sequences are, the higher the subjective visual quality is. Against the viewing distances, the differences among encoded 4K-UHD test sequences were less distinguished in longer distances from the display.

Analysis of Environment Factors in Pleurotus eryngii Cultivation House of Permanent Frame Type Structure (영구형 큰느타리버섯 재배사의 환경요인 분석)

  • Yoon Yong-Cheol;Suh Won-Myung;Lee In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.15 no.2
    • /
    • pp.125-137
    • /
    • 2006
  • Pleurotus eryngii is one of the most promising mushrooms produced on the domestic farms. The quality as well as quantity of Eryngii is sensitively affected by micro climate factors such as temperature, relative humidity, $CO_2$ concentration, and light intensity. To safely produce high-quality Eryngii all the yew round, it is required that the environmental factors be carefully controlled by well designed structures equipped with various facilities and control systems. At the commercial mushroom cultivation houses of permanent frame type (A, B), this study was carried out to find out reasonable range of each environmental factor and yield together with economic and safe structures influencing on the optimal productivity of Eryngii. This experiment was conducted for about two-year ken Nov. 2003 to Dec. 2005 in cultivation house. Ambient temperature during the experiment period was not predominantly different from that of a normal year. The capacity of the hot water boiler and the piping systems were not enough. Because the capacity of electric heater and air circulation were not enough, air temperatures in cultivation house before improvement of system were maintained somewhat lower than setting temperature, and maximum air temperature difference between the upper and lower growth stage during a heating time period was about 5.1. But the air temperatures after system improvement were maintained within the limits range of setting temperature without happening stagnant of air. Air temperature distribution was generally distributed uniform. Relative humidity in cultivation house before , improvement was widely ranged about $44{\sim}100%$. But as the relative humidity after improvement was ranged approximately $80{\sim}100%$, it was maintained within the range of relative humidity recommended. And $CO_2$ concentration was maintained about $400{\sim}3,300mg{\cdot}L^{-1}$ range. The illuminance in cultivation house was widely distributed in accordance with position, and it was maintained lower than the recommended illuminance range $100{\sim}200lx$. The acidity of midium was some lower range than the recommend acidity range of pH $5.5{\sim}6.5$. The yield was relatively ununiform. In case of bottle capacity of 1,300cc, the mushroom of the lowest grade was less than 3%. The consumption electric energy was quite different according to the cultivation season. The electric energy consumed during heating season was much more than that of cooling season.

Adaptive Search Range Decision for Accelerating GPU-based Integer-pel Motion Estimation in HEVC Encoders (HEVC 부호화기에서 GPU 기반 정수화소 움직임 추정을 고속화하기 위한 적응적인 탐색영역 결정 방법)

  • Kim, Sangmin;Lee, Dongkyu;Sim, Dong-Gyu;Oh, Seoung-Jun
    • Journal of Broadcast Engineering
    • /
    • v.19 no.5
    • /
    • pp.699-712
    • /
    • 2014
  • In this paper, we propose a new Adaptive Search Range (ASR) decision algorithm for accelerating GPU-based Integer-pel Motion Estimation (IME) of High Efficiency Video Coding (HEVC). For deciding the ASR, we classify a frame into two models using Motion Vector Differences (MVDs) then adaptively decide the search ranges of each model. In order to apply the proposed algorithm to the GPU-based ME process, starting points of the ME are decided using only temporal Motion Vectors (MVs). The CPU decides the ASR as well as the starting points and transfers them to the GPU. Then, the GPU performs the integer-pel ME. The proposed algorithm reduces the total encoding time by 37.9% with BD-rate increase of 1.1% and yields 951.2 times faster ME against the CPU-based anchor. In addition, the proposed algorithm achieves the time reduction of 57.5% in the ME running time with the negligible coding loss of 0.6%, compared with the simple GPU-based ME without ASR decision.

A Study on National Identity of Adolescents of Multi-cultural Family -An Application of Heater's Theory- (다문화가족 청소년의 국민정체성에 관한 연구 -Heater의 이론을 적용하여-)

  • Jeon, Byeong-Joo
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.33-41
    • /
    • 2014
  • This study conducted a survey 212 adolescents in multi-cultural family to measure the level of their discrimination experience and acculturation stress by comparing with social integration analysis frame of D. Heater and examined how it affects them to national identity. Followings are the main results of this study. First, after measuring the discrimination experience level of those surveyed, their average was a bit higher than the normal level, showing 2.63(SD=.72), and their acculturation stress was 2.48(SD=.65) which is average. Second, their level of national identity showed 2.16(SD=.57), which was lower than the normal level, and there was statistically a meaningful difference between the groups depending on their academic level, parents' marital status, mother's Korean ability. Third, the factors that affected in national identity were in the order of their discrimination experience(${\beta}$=-.305), parents' marital status(${\beta}$=.286), acculturation stress(${\beta}$=-.225), academic level(${\beta}$=.186), mother's Korean ability(${\beta}$=.173). Based on these results, several ways are suggested to improve national identity of adolescents in multi-cultural family.

Building practical treatment protocol by comparing the effect of adjustment between Thompson Terminal Technique and Exercise in malpositioned pelvic which induces imbalance of body (골반변위에 따른 신체 불균형에 대한 톰슨터미널테크닉과 운동요법의 교정 효과비교분석을 통한 임상치료프로토콜의 구성)

  • Park, Joon-Ki;Choi, Eun-Seok;Kim, Min-Jung;Lee, Man-Su;Lee, Min-Sun
    • Journal of Digital Convergence
    • /
    • v.14 no.5
    • /
    • pp.445-457
    • /
    • 2016
  • The purpose of the study is to provide frame work of efficient diagnostic and treatment protocol for the people with malpositioned pelvic which causes imbalance of body. Study subjects were grouped as experimental, comparison and control group. Each group consisted of five men and five women randomly assigned. Experimental group was to be tested with Thompson Terminal Technique, its corrective effect and the effect of maintaining the treatment. There were 43.01%p difference in effectiveness of the applied technique between Thompson Terminal Technique and Muscle Energy Technique. It indicates that Thompson Terminal Technique is more effective in treating pelvic misalignment than Muscle Energy Technique. As a result, the use of chiropractic and resistance exercises is proven to be effective for treating the imbalance of body. Also, to maximize the effect of treatment, it is preferable to apply Muscle Energy Technique after applying the Thompson Terminal Technique.