• Title/Summary/Keyword: frame building

Search Result 1,103, Processing Time 0.029 seconds

Advanced Analysis of Connections to Concrete-Filled Steel Tube Columns using the 2005 AISC Specification (AISC 2005 코드를 활용한 콘크리트 충전 합성기둥의 해석과 평가)

  • Park, Ji-Woong;Rhee, Doo-Jae;Chang, Suong-Su;Hu, Jong-Wan
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.3 no.3
    • /
    • pp.9-21
    • /
    • 2012
  • Concrete filled steel tube (CFT) columns have been widely used in moment resisting frame structures both in seismic zones. This paper discusses the design of such members based on the advanced methods introduced in the 2005 AISC Specification and the 2005 Seismic Provisions. This study focuses particularly on design following both linear and nonlinear methods utilizing equivalent static and dynamic loads for low-rise moment frames. The paper begins with an examination of the significance of pseudo-elastic design interaction equations and the plastic ductility demand ratios due to combined axial compressive force and bending moment in CFT members. Based on advanced computational simulations for a series of five-story composite moment frames, this paper then investigates both building performance and new techniques to evaluate building damage during a strong earthquake. It is shown that 2D equivalent static analyses can provide good design approximations to the force distributions in moment frames subjected to large inelastic lateral loads. Dynamic analyses utilizing strong ground motions generally produce higher strength ratios than those from equivalent static analyses, but on more localized basis. In addition, ductility ratios obtained from the nonlinear dynamic analysis are sufficient to detect which CFT columns undergo significant deformations.

A Fundamental Study for Development on Waterproof and Flame Retardant processing technology the Interior Wood of using Induced electricity heating Microwave (유전가열 마이크로파를 적용한 방수·방염 내장목재 개발을 위한 기초적 연구)

  • Park, Cheul-Woo;Heo, Jae-Won;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.35-41
    • /
    • 2008
  • Qualitative enhancement of dwelling life has changing the recognition for the environment friendly wood which is being highlighted for its usage as an interior materials. This trend may prove the excellent performance of wood whose inherent characteristics has its comfortable, mild feeling of material, sound resistance and stabilities and the market of interior woods including floor, moulding and wooden panel as finishing interior materials is growing sustainably. However, since this materials is vulnerable to humidity and flame, waterproofing and flame retarding stability, an essential condition for interior materials, together with maintenance, are the main topics to be resolved. From the above-mentioned results, as a result of waterdrop contact angle, wood absorption volume and water content percentage test and the performance test of the processed materials after flame retardant, though there was some submerging time changes among types of woods for ensuring waterproofing performance improvement but as time passes, similar tendency was noticed to be formulated. As the submerging time is increased, so does the absorption volume and accordingly optimal level of range is judged to be drawn in order to ensure excellent performance, taking optimal economy into consideration. Therefore, it is considered that above-mentioned woods could be utilized for waterproof and flame retardant processed interior materials using uniform microwave and in order to put this technology into practical application, a research by way of diversified performance proving is required to be carried out.

  • PDF

A Feasibility Study on Small-sized Rental Residential Building Project through Risk Management (리스크 관리를 통한 프로젝트 타당성 검토방안에 대한 연구 -소규모 임대주택을 대상으로-)

  • Kim Sang-Chul;Park Chan-Jeong;Yoon Jun-Seon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.3 s.19
    • /
    • pp.97-105
    • /
    • 2004
  • Planning phase became very important because the construction market in Korea is often unpredictable. The existing feasibility analysis cannot fulfill its purpose in development projects because they are based on intuitive approach rather than systematic approach. The purpose of this study is to make a prototype of feasibility model to be a good investment. To build the model, first, risk factors which can be occurred in project had to be selected. Risk factors were divided into several groups in basis of characteristical risk. Economical risk factors were input on financial analysis. Then, to catch the relevance and influence of all risk factors, influence diagram and decision tree were made. Finally, sensitivity analysis was activated, then what the critical factors were, and how those factors could be solved. Through these procedures, the feasibility model that was made in this study could include both quantitative and qualitative factors. This model is expected to be used as a guide of feasibility analysis including all risk factors and is to serve systematic frame in planning and feasibility stage.

A Study on the Site analysis of Jongmyo area -With Feng-shui theory and Geomagnetic Field

  • Han, Jong-Koo;Park, Tong-So
    • KIEAE Journal
    • /
    • v.2 no.4
    • /
    • pp.41-47
    • /
    • 2002
  • East Asian explain the changes of substance happened on earth and those of human life with the conceptual frame of "Gi-ki"(地氣; earth vital energy) and organize them by the system of "Feng-shui(風水) theory. The core of Feng-shui theory is reading the expression of the nature and feeling the Gi-ki from the expression. One of the properties of the earth is that the earth has a magnetic field associated with it- the Geomagnetic field. The geomagnetic field is produced by a combination of the effects of electric currents in the earth's liquid core, the magnetization of crustal rocks, external electric current systems that surround the earth and currents induced in the outer layers of the earth by magnetic field variations. The sameness of logic between Feng-shui and geopathic zones is that both are concerned with the discrimination of site and the energy of places, in other words both disciplines are concerned with how the environment can influence people. In this context the operation of Gj-ki can be related with the effect caused by geomagnetic field on site. In this study Jongmyo(宗廟), one of the representative traditional architecture in Korea is selected because the site selection and building layout follows Feng-shui faithfully according to Taejo silok (太祖實錄, Annals of King Taejo). Observing the landforms surrounding Jongmyo, Jongmyo is apparently located in auspicious places named Gumge Poranhyoeng(金鷄抱卵形, a Feng-shui landscape of golden hen sitting on eggs). The geomagnetic investigation of Jongmyo shows that the geomagnetic values of Toekan(the space near Hyeol) are relatively high and uniform and those of Sangweoldae and Haweoldae are decreased in accordance with the distance. The result shows that there is possibility that Feng-shui has scientific basis related with geomagnetic field. Feng-shui theory can suggest a direction for designing the sustainable building for living with nature.

A Case Study on Explosive Demolition of Gunsan Steam Power Station in Republic of Korea (군산화력발전소 발파해체 실용화 시험시공 사례)

  • Min, Hyung-Dong;Song, Young-Suk;Kim, Hyo-Jin;Seo, Young-Soo
    • Explosives and Blasting
    • /
    • v.25 no.2
    • /
    • pp.11-21
    • /
    • 2007
  • The main structure of Gunsan steam power station was demolished by the toppling method using high explosives. Height of a main building is 58m and a total floor area is $292,000m^2$. It is Rahmen(rigid-frame) structure consisted of almost columns and beams and slabs exist only in one part of the building for the electricity generators equipments. To improve the efficiency of blasting work, it is separated into 4 sectors. Blasting floors were 1, 2, 3, & 4 stories from first sector to third sector, while 1, 2, 5, & 7 of fourth sector were blasted because it had not slabs. About 102.675 kg of the MegaMITE were used with 225 electric detonator and 638 non-electric detonators to check detonator connection and confidence of detonation. The blasting noise and vibration were monitored to evaluate the environment effect and the damage of the nearby structures.

Part II A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings (현행소방시설설치기준의 분석과 개선방안에 관한 연구II)

  • 정병재;이경회
    • Fire Science and Engineering
    • /
    • v.5 no.1
    • /
    • pp.5-14
    • /
    • 1991
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it Is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the latter fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First, We are going to look history of the fire protection system and change course of that with the year and facility. Second. We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have to reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use count about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size (창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석)

  • Kim, Seong-Beom;Lee, Su-Yeul;Kim, Dong-Yoon;Choi, Won-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.49-60
    • /
    • 2020
  • This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 ㎡. The analysis results were as follows. First, as the window glass's thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m × 1m window's thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m × 2 m window. Secondly, in the comparison of performance for increasing area with 2 m × 2 m and 3 m × 3 m windows, the 3 m × 3 m window's thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model's total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

Seismic Capacity of Non-seismic Designed RC Framed Building Retrofitted by Double I-type Metallic Damper (더블 I형 감쇠장치로 보강한 비내진 RC 골조의 내진성능 평가)

  • Hur, Moo-Won;Chun, Young-Soo;Hwang, Jae-Seung;Kim, Jong-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.10-17
    • /
    • 2015
  • In this study, to examine seismic reinforcement effect of a school building constructed prior to application of seismic design, a Double I-type damper supported by wall was installed to perform comparative analysis on existing non-seismic designed RC frame. As a result of experiment, while non-seismic designed specimen showed rapid reduction in strength and brittle shear destruction as damages were focused on top and bottom of left and right columns, reinforced specimen showed hysteretic characteristics of a large ellipse with great energy absorption ability, exhibiting perfectly behavior with increased strength and stiffness from damper reinforcement. In addition, as a result of comparing stiffness reduction between the two specimens, specimen reinforced by shear wall type damper was effective in preventing stiffness reduction. Energy dissipation ability of specimen reinforced by Double I-type damper was about 3.5 times as high as energy dissipation ability of non-reinforced specimen. Such enhancement in energy dissipation ability is considered to be the result of improved strength and deformation.

The Study of Restoring Silsangsa Wooden Pagoda (실상사 목탑의 복원 연구)

  • Kim, Kyeong-Pyo
    • Journal of architectural history
    • /
    • v.16 no.6
    • /
    • pp.7-26
    • /
    • 2007
  • This article is about restoring the wooden pagoda which located in Silsangsa Temple after historical research. The process of this study, first of all, the theoretical study was considered about similar examples of wooden pagoda and gilt-bronze pagoda in Gorye period and wooden pagoda in contemporary period. After that, the study was established by the present condition of Silsangsa wooden pagoda site, the characteristic of Silsangsa wooden pagoda, the form of arrangement, the scale and height. Finally, considering those studies, the wooden pagoda designed in detail. This restoring design tried to follow the inference in that time. Moreover, the design tried to involve the elements of characteristic of region and Silsangsa wooden pagoda. Therefore, the research establish period of Silsangsa wooden pagoda in Gorye period. Locally, it considered both elements of Silla and Baeckje. The arrange form of restoring wooden pagoda was freestyle arrangement that had two main building of a temple and one middle pagoda. The idea of structure was to establish of double Core system. This system inferred from the system of building structure in ancient wooden pagoda and middle and modern age of multistory wooden construction. According to measurement of foundation stone, the scale of restoring wooden pagoda followed the skill of Tang-scale. The connection structure of each floor followed laminated structure which was the general form of log frame in that time. After study of foundation's condition, the present writer deseeded to have restoring the wooden pagoda 9 stories tall. The final aim was to depend on the structural intuition of the present writer, the writer tried to restore beautiful wooden pagoda according to in those days which is solution for contradiction of unclear point. So, it could be make out a plane of restoring wooden pagoda.

  • PDF

A Study on the Seismic Behavior of Small-Size Reinforced Concrete Buildings in Korea (국내 소규모 철근콘크리트 건축물의 내진거동 고찰)

  • Kim, Taewan;Eom, Taesung;Kim, Chul-Goo;Park, Hong-Gun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.171-180
    • /
    • 2014
  • Since the execution of structural design by professional structural engineers is not mandatory for small-size buildings in Korea, structural design is conducted by architects or contractors resulting in concern about the seismic safety of the buildings. Therefore, the Korean Structural Engineers Association proposed dedicated structural design criteria in 2012. The criteria were developed based on a deterministic approach in which the structural members are designed only with information of story and span length of the buildings and without structural analyses. However, due to the short time devoted to their development, these criteria miss satisfactory basis and do not deal with structural walls popularly used in Korea. Accordingly, the Ministry of Land, Infrastructure and Transport launched a research on the 'development of structural performance enhancement technologies for small-size buildings against earthquakes and climate changes'.. As part of this research, this paper intends to establish direction for the preparation of deterministic structural design guidelines for seismic safety of domestic small-size reinforced concrete buildings. To that goal, a typical plan of these buildings is selected considering frames only and frames plus walls, and then design is conducted by changing the number of stories and span length. Next, the seismic performance is analyzed by nonlinear static pushover analysis. The results show that the structural design guidelines should be developed by classifying frames only and frames plus walls. The size and reinforcement of structural elements should be provided in the middle level of the current Korean Building Code and criteria for small buildings by considering story and span length for buildings with frames only, and determined by considering the shape and location of walls and the story and span length as well for buildings with frames plus walls. It is recommended that the design of walls should be conducted by reducing the amount of walls along with symmetrically located walls.