Seismic Capacity of Non-seismic Designed RC Framed Building Retrofitted by Double I-type Metallic Damper  

Hur, Moo-Won (단국대학교 건축공학과)
Chun, Young-Soo (LH 토지주택연구원)
Hwang, Jae-Seung (전남대학교 건축학부)
Kim, Jong-Ho (전남대학교 건축공학과)
Publication Information
Journal of the Korea institute for structural maintenance and inspection / v.19, no.6, 2015 , pp. 10-17 More about this Journal
Abstract
In this study, to examine seismic reinforcement effect of a school building constructed prior to application of seismic design, a Double I-type damper supported by wall was installed to perform comparative analysis on existing non-seismic designed RC frame. As a result of experiment, while non-seismic designed specimen showed rapid reduction in strength and brittle shear destruction as damages were focused on top and bottom of left and right columns, reinforced specimen showed hysteretic characteristics of a large ellipse with great energy absorption ability, exhibiting perfectly behavior with increased strength and stiffness from damper reinforcement. In addition, as a result of comparing stiffness reduction between the two specimens, specimen reinforced by shear wall type damper was effective in preventing stiffness reduction. Energy dissipation ability of specimen reinforced by Double I-type damper was about 3.5 times as high as energy dissipation ability of non-reinforced specimen. Such enhancement in energy dissipation ability is considered to be the result of improved strength and deformation.
Keywords
Double I-type Hysteretic damper; Strength degradation; Stiffness degradation; Energy dissipation; retrofitted;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 KBC, Korean Building and Commentary (2009), Architectural Institute of Korea, 88-90.
2 Hur, M. W., Chun, Y. S., Hwang, J. S., and Park, S. C., (2014), Seismic Capacity of RC Framed Building Retrofitted by Double I-type Metallic Damper, KCI, Spring 2014 Convention, 1039-1040.
3 Baek, E. L., Oh, S. H., and Lee, S. H., (2014), Seismic Performance of an Existing Low-Rise Reinforced Concrete Piloti Building Retrofitted by Steel Rod Damper, Journal of EESK, 18(5), 241-251.
4 Oh, S. H., Kim, Y. J., Tyu, H. S., Choi, H. B., and Kang, C. H., (2005), Hysteresis Behavior of Beam-to-Column Connections with Elasto-Plastic Hysteretic Dampers, Architectural Institute of Korea, 25(1), 635-638.
5 Lee, H. H., (2012), Hysteretic Behaviors of Metallic Dampers with the Various Slit Shape, Journal of Korea institute for Structural Maintenance Inspection, 16(2), 206-207.
6 Lee, H. H., Kim, S. I., (2011), Hysteretic Behaviors of Metallic Dampers with the Various Slit Shape, Journal of Korea institute for Structural Maintenance Inspection, 15(5), 199-208.   DOI   ScienceOn
7 Lee, H. Ho., Kim, S. I., (2010), Metalic Damper Shape and Cyclic Behavior for the Seismic Capacity Improvement of Building Structures, Journal of Korea institute for Structural Maintenance Inspection, 14(3), 123-130.
8 Japan Building Disaster Prevention Association, (2001), Standard for Damage Level Classification, Tokyo, Japan, 250.
9 ACI Committee 374, (2014), Acceptance Criteria for Moment Frames Based on Structural Testing and Commentary, ACI 374.1-5.