• Title/Summary/Keyword: frame building

Search Result 1,103, Processing Time 0.034 seconds

Active Window to Reduce the Exterior Noise Flowed Through the Open Window (열린 창문을 통해 유입되는 소음을 저감하는 능동소음제어 창문)

  • Kwon, Byoung-Ho;Park, Young-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.820-827
    • /
    • 2011
  • Recently, noise has been regarded as one of the most notorious and frequent environmental pollutions which can be often encountered not only in the living space but also in the industrial site. Studies on physiological and psychological effects of long-term noise exposure to human being have commanded the public interest on noise issues. Since environmental noises such as traffic noise and construction noise is mainly flowed through the open window, it is necessary to develop the active noise control system to reduce it inside the building. Although control speakers and microphones for the noise signal measurement in the control region are essential for the conventional active noise control methods, it is impossible to implement them in the control region in the building environment because the control region is the living quarter and they may hinder activities of the residents. Therefore, we proposed the active window system to reduce the exterior noise flowed through the open window with microphones installed outside the window and control speakers installed at the frame of the window. To confirm the performance of the proposed active window, we carried out the simulation and experiment using active window system with 8 control speakers. Simulation results showed the noticeable noise reduction effect inside the control region within the frequency range without the spatial aliasing. Experimental result showed that the total acoustic potential energy inside the room of the scale model is reduced to about 10dB within the interest of frequency range.

The Study on the Analysis of Factors Decreasing Construction Labor-Productivity Using AHP Method (AHP기법을 이용한 건설노동생산성 저하요인 분석에 관한 연구)

  • Pyo Young-Min;Bae Soo-Yong;Ryu Hyoung-Han;Lee Sang-Beom
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.141-147
    • /
    • 2005
  • Usually, processing whole project or a part of frame work delays due to acceleration, changing orders, management, characters of project. overtime, worker crowding, early occupation in the field of construction. Through a whole project, these factors cause decreasing construction labor-productivity which is the most dependent in business of construction. These kind of decreasing of construction labor-productivity cause many negative effects, just as extension of time, increasing cost in project of construction. Regardless of characters of construction or decreasing labor-productivity, extension of time is a incident which needs acceleration, also it cause a high possibility of claim and dispute. The productivity has just a broad meaning in business of construction. That's why it's difficult to apply in the field of construction. Especially, factors increasing or decreasing labor-productivity is defined by analysis of working as qualitative and outlined evaluation. However, study of the each factor decreasing construction labor-productivity analysis has not researched, because of difficulty of systematic measurement and management. The existed studies about management of productivity are just focused on estimation of productivity, not on evaluation of productivity. It was true that I couldn't examine clearly about the analysis of how much important per each the factor which have influence on labor-productivity because of the characteristic as qualitative that the labor productivity have On this study, i tried to get the factors decreasing of labor- productivity with gathering opinions of panels of expert's studies about the factors decreasing of labor-productivity on project of construction through Delphi method and i evaluated the result factors as quantitatively and subjectively about importance of factors decreasing construction labor-productivity Analysis, using AHP Method by Saaty. Also, using Delphi and AHP method, 1 suggest substantiated method qualitative factors are measured by quantitative criteria.

  • PDF

The 'Plastic Architecture' of De Stijl, Its Utopian Vision (드 스틸의 조형적 건축, 그 유토피안 비전)

  • Yun, Nan-Jie
    • The Journal of Art Theory & Practice
    • /
    • no.9
    • /
    • pp.151-170
    • /
    • 2010
  • As an art group, De Stijl (1917-1931) led a total art movement encompassing painting, sculpture, design, and architecture. Among these, architecture, as a model of the total art pursued by the group, was encapsulated by the term 'plastic architecture.' The term reflects architecture's shared features with plastic art, especially its pictorial characteristics. Firstly, De Stijl architecture shares geometric form with painting. Assembled in simple, clear and rational structures, the geometric forms signified universal forms, and extended the pictorial experimentation that Mondrian exercised through Neo-Plasticism to architecture. Constructed with colour fields made of concrete wall, De Stijl architecture is geometric abstract painting embodied in space. Together with such pictorial characteristics, large plate glass windows, narrow window frames, and cantilever structure minimize the building's visual weight. De Stijl architecture, which appears suspended in the air, is an architectural version of the abstract paintings of the era that revealed unknown spaces beyond perspective. De Stijl architecture is also an 'open' architecture, where the units placed as if radiating from the center form relations with each other flexibly and organically. The observer in such a space is encouraged to experience space within time, as his/her physical and visual mobility and extension are maximized. De Stijl architecture is an example of how the time-space continuum, represented within picture frame through Cubism, Futurism, and abstract art, can be realized in space. By transforming the ideal space of painting into real space in this way, 'plastic architecture' turned out to be an architectural manifestation of the utopianism of the era, aimed at building a society in 'perfect harmony.' However, such rationalism and universalism are not free from the violence of totalization that deletes various differences. This is evident in the history that followed as the geometric form of architecture and urban planning proliferated across the globe, engulfing the diverse natural landscapes and local cultures.

  • PDF

A Study on the Architectural of Jae-sil in Jeonalbukdo (전라북도 재실 건축에 관한 연구)

  • Lee, Sang-Sun;Shin, Woong-Ju
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.15 no.4
    • /
    • pp.35-42
    • /
    • 2013
  • The study aims to investigate general characteristics of Jae-sil from an architectural perspective by grasping location, deployment, structure, and plan composition based on existing inhabited conditions in Jeollabukdo. Results derived from the study are as follows. First, the location of Jae-sil is classified into mountainous and village types, and the two types showed a similar distribution. The village type showed the most distribution in the foot of a mountain in the rear of village, while the mountainous type is close to graveyard. The Jae-sil were mostly exposed to south, southeast, and southeast, which was not significantly different from residence. For deployment of the Jae-sil, a "二" shaped house, where main quarter and gated building are parallel located, can be common, indicating that additional attached building is less required. Second, for the platform out of structural components, coursed masonry was conducted by using natural rocks, and placed were a prop on the platform, first line on processed foot stone, and others on natural foot stone. For pillar, front line round columns, while others square columns. The binding type of the upper part of pillar is dominated by jangyeosujang and sorosujang. For wooden frame structure, 5ryangs were the most distributed, and out of these, 1goju 5ryang was the most generally used. For a roof part, it was composed with gambrel roof with single eave, and the roof was constructed by placing traditional Korean tile roof on the top. Third, for a size of Jae-sil out of plan composition, although the facade and the side of it were presented in a diverse manner, 4 facade rooms and 1.5 side rooms were the most frequently presented, and all Jae-sil were equipped with front ceremonial space. For spatial composition of Jae-sil, main floored hall is placed at the center, and each room is placed on the left and right side to secure space for ancestral rite for participants of it, and for a house with 5 rooms or more, it shows that main floored hall and rooms are weighted from side to side.

A Study on Setting up Conservation Areas through Habitat Value Assessment of Developing Area (개발예정지역에서의 서식지 가치평가를 통한 보전지역 설정에 관한 연구)

  • Park, Yong-Su;Kim, Dae-Heui;Cho, Dong-Gil;Kim, Kwi-Gon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.3
    • /
    • pp.26-38
    • /
    • 2006
  • For both a healthy environment and sustainable development, we frame a habitat assessment method, concerning biodiversity and physical characteristics. With the method, we set up and extract conservation areas from Peace Valley Resort Development Areas which can function as habitats. Absolute and relative assessment items which are the size of area, habitation of species with conservation value, distribution of communities, functions of habitats, ratio of non-native plants, connectivity of habitats, vegetation layers of forests and age of forests, and water systems are considered on newly extracted conservation areas, and the habitat value assessment was calculated on the items in a 3-point scale. By comparing and examining 3 existing proposals for extracted conservation areas, we assess existing proposals, make an alternative proposal, and try to verify the possibility of applicability to extracted conservation areas. Proposal A and C must not be adopted since almost all conservation areas would be developed in the proposals. Proposal B, consisting of 53% development areas and 47% non-development areas, does not have enough development areas, so high density building arrangements should be encouraged in order to preserve conservation areas. Therefore, proposal B would be the best in ecological terms among the 3 proposals, if 3 conditions are considered : 1) new extracted conservation areas should be conserved; 2) 10~15m wide green-zones on both sides of the water system, which can play a role as ecological corridors, should be considered in development areas; 3) building arrangement should not interrupt the ecological corridors.

An effective load increment method for multi modal adaptive pushover analysis of buildings

  • Turker, K.;Irtem, E.
    • Structural Engineering and Mechanics
    • /
    • v.25 no.1
    • /
    • pp.53-73
    • /
    • 2007
  • In this study, an effective load increment method for multi modal adaptive non-linear static (pushover) analysis (NSA) for building type structures is presented. In the method, lumped plastisicity approach is adopted and geometrical non-linearties (second-order effects) are included. Non-linear yield conditions of column elements and geometrical non-linearity effects between successive plastic sections are linearized. Thus, load increment needed for formation of plastic sections can be determined directly (without applying iteration or step-by-step techniques) by using linearized yield conditions. After formation of each plastic section, the higher mode effects are considered by utilizing the essentials of traditional response spectrum analysis at linearized regions between plastic sections. Changing dynamic properties due to plastification in the system are used on the calculation of modal lateral loads. Thus, the effects of stiffness changes and local mechanism at the system on lateral load distribution are included. By using the proposed method, solution can be obtained effectively for multi-mode whereby the properties change due to plastifications in the system. In the study, a new procedure for determination of modal lateral loads is also proposed. In order to evaluate the proposed method, a 20 story RC frame building is analyzed and compared with Non-linear Dynamic Analysis (NDA) results and FEMA 356 Non-linear Static Analysis (NSA) procedures using fixed loads distributions (first mode, SRSS and uniform distribution) in terms of different parameters. Second-order effects on response quantities and periods are also investigated. When the NDA results are taken as reference, it is seen that proposed method yield generally better results than all FEMA 356 procedures for all investigated response quantities.

Evaluation of seismic performance of mid-rise reinforced concrete frames subjected to far-field and near-field ground motions

  • Ansari, Mokhtar;Ansari, Masoud;Safiey, Amir
    • Earthquakes and Structures
    • /
    • v.15 no.5
    • /
    • pp.453-462
    • /
    • 2018
  • Damages to buildings affected by a near-fault strong ground motion are largely attributed to the vertical component of the earthquake resulting in column failures, which could lead to disproportionate building catastrophic collapse in a progressive fashion. Recently, considerable interests are awakening to study effects of earthquake vertical components on structural responses. In this study, detailed modeling and time-history analyses of a 12-story code-conforming reinforced concrete moment frame building carrying the gravity loads, and exposed to once only the horizontal component of, and second time simultaneously the horizontal and vertical components of an ensemble of far-field and near-field earthquakes are conducted. Structural responses inclusive of tension, compression and its fluctuations in columns, the ratio of shear demand to capacity in columns and peak mid-span moment demand in beams are compared with and without the presence of the vertical component of earthquake records. The influences of the existence of earthquake vertical component in both exterior and interior spans are separately studied. Thereafter, the correlation between the increase of demands induced by the vertical component of the earthquake and the ratio of a set of earthquake record characteristic parameters is investigated. It is shown that uplift initiation and the magnitude of tensile forces developed in corner columns are relatively more critical. Presence of vertical component of earthquake leads to a drop in minimum compressive force and initiation of tension in columns. The magnitude of this reduction in the most critical case is recorded on average 84% under near-fault ground motions. Besides, the presence of earthquake vertical components increases the shear capacity required in columns, which is at most 31%. In the best case, a direct correlation of 95% between the increase of the maximum compressive force and the ratio of vertical to horizontal 'effective peak acceleration (EPA)' is observed.

Ambient vibration based structural evaluation of reinforced concrete building model

  • Gunaydin, Murat;Adanur, Suleyman;Altunisik, Ahmet C.
    • Earthquakes and Structures
    • /
    • v.15 no.3
    • /
    • pp.335-350
    • /
    • 2018
  • This paper presents numerical modelling, modal testing, finite element model updating, linear and nonlinear earthquake behavior of a reinforced concrete building model. A 1/2 geometrically scale, two-storey, reinforced concrete frame model with raft base were constructed, tested and analyzed. Modal testing on the model using ambient vibrations is performed to illustrate the dynamic characteristics experimentally. Finite element model of the structure is developed by ANSYS software and dynamic characteristics such as natural frequencies, mode shapes and damping ratios are calculated numerically. The enhanced frequency domain decomposition method and the stochastic subspace identification method are used for identifying dynamic characteristics experimentally and such values are used to update the finite element models. Different parameters of the model are calibrated using manual tuning process to minimize the differences between the numerically calculated and experimentally measured dynamic characteristics. The maximum difference between the measured and numerically calculated frequencies is reduced from 28.47% to 4.75% with the model updating. To determine the effects of the finite element model updating on the earthquake behavior, linear and nonlinear earthquake analyses are performed using 1992 Erzincan earthquake record, before and after model updating. After model updating, the maximum differences in the displacements and stresses were obtained as 29% and 25% for the linear earthquake analysis and 28% and 47% for the nonlinear earthquake analysis compared with that obtained from initial earthquake results before model updating. These differences state that finite element model updating provides a significant influence on linear and especially nonlinear earthquake behavior of buildings.

Study on the Cable Wall System Applied to Reinforced Concrete Exterior (철근콘크리트구조 외장재에 케이블월 시스템 적용에 관한 연구)

  • Park, Hyun-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.579-585
    • /
    • 2017
  • Development of a facade system that can reduce load factor and costs in high-rise building construction is required. The proposed cable wall system is used as a structural support by the glass-cable and can increase openness on lower elevations and the lobby area. Its use in high-rise buildings can reduce construction costs. Without transferring directly a strong initial tension of the cable to the building frame is connected to the steel member and the reinforced concrete structures, by absorbing the initial tension of the cable, it is possible to control the occurrence of a strong concentrated loads to the structure. Comparison of load-displacement test results from the numerical analysis with the test results showed reasonable agreement, Therefore, the proposed numerical results confirm good prediction of cable behavior for the facade system.

A Study on the Design Characteristics and the Origin of Three-story Section in the Unite d'Habitation at Marseilles (마르세이유 거대 주거동의 건축설계 특성(特性)과 단면 3층 단위체 기원(起源)에 관한 연구(硏究))

  • Yoon, Chae-Shin
    • Journal of architectural history
    • /
    • v.7 no.4 s.17
    • /
    • pp.61-75
    • /
    • 1998
  • The Unite d'Habitation at Marseilles was an experimental project that Le Corbusier had been waiting for since 1920s in order to explore his ideals and visions in mass housing and city planning. As a leader of the first generation members in CIAM, Le Corbusier tried to give a new form and an order to the Unite d'Habitation at Marseilles in both building design and city planning level. The purpose of this research is to investigate the design characteristics of the Unite d'Habitation at Marseilles in three different levels of built environment with a particular emphasis on the process through which an original form is derived from its contextual settings. In the level of city planning, Le Corbusier aimed to reshape traditional low-rise urban housing by deploying several Unites spaciously. Le Corbusier believed that the spacious deployment of Unites would bring us both the functional economy in the city and the natural amenity in the suburbs. As Unite d'Habitation would be called frequently as vertical garden city, the influence of suburban garden city on Unite d'Habitation is apparent. In the building level, the binomial harmony of individual-collectivity was pursued by providing three different public floors and by combining 23 different family unit types in the Unite d'Habitation at Marseilles. In order to visualize the concept of object-type, family units were prefabricated and inserted into the structural frame of the Unite d'Habitation at Marseilles. Two family units are combined to make a three-story section with street corridor in the middle. This three-story section unit is very original as it has access corridor every third floor and each unit could have considerable depth with the help of the living space of two story height. In consideration of formal and plan similarity as well as contextual edivdence, it is concluded that the three-story section of the Unite d'Habitation is derived more from Narkomfin Apartments than from the monastery at Ema or Immuble Villas.

  • PDF