• Title/Summary/Keyword: fracture tendency

Search Result 162, Processing Time 0.026 seconds

The Learning Curve for Biplane Medial Open Wedge High Tibial Osteotomy in 100 Consecutive Cases Assessed Using the Cumulative Summation Method

  • Lee, Do Kyung;Kim, Kwang Kyoun;Ham, Chang Uk;Yun, Seok Tae;Kim, Byung Kag;Oh, Kwang Jun
    • Knee surgery & related research
    • /
    • v.30 no.4
    • /
    • pp.303-310
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate whether surgical experience could improve surgical competency in medial open wedge high tibial osteotomy (MOWHTO). Materials and Methods: One hundred consecutive cases of MOWHTO were performed with preoperative planning using the Miniaci method. Surgical errors were defined as under- or overcorrection, excessive posterior slope change, or the presence of a lateral hinge fracture. Each of these treatment failures was separately evaluated using the cumulative summation test for learning curve (LC-CUSUM). Results: The LC-CUSUM showed competency in prevention of undercorrection, excessive posterior slope change, and lateral hinge fracture after 27, 47, and 42 procedures, respectively. However, the LC-CUSUM did not signal achievement of competency in prevention of overcorrection after 100 procedures. Furthermore, the failure rate for overcorrection showed an increasing tendency as surgical experience increased. Conclusions: Surgical experience may improve the surgeon's competency in prevention of undercorrection, excessive posterior slope change, and lateral hinge fracture. However, it may not help reduce the incidence of overcorrection even after performance of 100 cases of MOWHTO over a period of 6 years.

Infraorbital Nerve Function Following Tailoring of Medpor® in Reconstruction of Inferior Orbital Wall Fracture (안저골절재건 시 Medpor®의 맞춤조작에 따른 안와아래신경의 기능)

  • Kwon, Yong-Seok;Kim, Myung-Hoon;Lee, Jang-Ho;Heo, Jung;Lee, Keun-Cheol;Kim, Seok-Kwun
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.675-679
    • /
    • 2008
  • Purpose: In the orbital floor fracture, sensory impairment due to the damage of the infraorbital nerve is one of the most common symptom and complication. In this report, we have the assumption that tailoring of $medpor^{(R)}$ for decompression may have correlations to the damage and regeneration of the nerve. Methods: Among patients who had open reduction for pure orbital floor fracture in our hospital from March 2005 to March 2008, we selected 80 cases. In 40 cases, we inserted tailored $medpor^{(R)}$, and in other 40 cases, non-tailored $medpor^{(R)}$ was inserted. Patient's reports were obtained and analyzed, and the pin-prick test and the 2-point discrimination test on the infraorbital nerve regions were done for testing the sensory impairments. Results: The results show that the patients who adopted sculpture of $medpor^{(R)}$ showed higher tendency of recovery of sensory impairments in the patient's subjective report, static touch sensation, static two point discrimination using. And in postoperative 3 months, there are statistically significant recovery of sensory symptoms, signs and the result of sensory tests. Conclusion: From these results, tailored $medpor^{(R)}$ in reconstruction of orbital wall fracture may improve recovery of sensory impairments for decreasing of compression of infraorbital nerve.

The Results of Primary Repair in Acute Injuries of the Posterior Cruciate Ligament (후방 십자 인대 급성 손상에서 일차 복원술의 결과)

  • Lee, Dong-Chul;Baek, Seung-Hee
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.101-111
    • /
    • 2001
  • Background: We analyze the functional evaluation, posterior stability after surgery of acute injuries in the femoral detachment and tibial avulsion fracture of posterior cruciate ligament. Materials and Methods: Twenty two patients who underwent primary repair were followed more than one year after operation (mean follow-up 33.7 months). The patients were evaluated with KT 2000 arthrometer and posterior stress test for posterior stability. Lysholm knee score was used for knee function. Results: Lysholm score revealed 85.3 in femoral detachment group and 91.1 in tibial avulsion fracture group (P<0.05). Posterior displacement of the posterior stress test showed 17.2 mm at initial injury and 8.6 mm at last follow up in femoral detachment group, 16.8 mm at initial injury and 7.1 mm at last follow up in tibial avulsion fracture group. There revealed the tendency of the improved posterior stability of the tibial avulsion group compared with femoral detachment group, but there showed no statistical significance in KT 2000 arthrometer and posterior stress x-ray. Conclusion: Functional results of tibial avulsion fracture group revealed the better outcome compared with femoral detachment group, but the degree of posterior stability in tibial avulsion fracture group showed no statistical significance in posterior stability.

  • PDF

A STUDY OF CORRELATION BETWEEN MANDIBULAR ANGLE FRACTURE AND THE MANDIBULAR THIRD MOLAR (하악 제3대구치와 하악 우각부 골절과의 상관관계에 대한 연구)

  • Park, Sun-Hye;Choi, Jun-Young;Kim, Seong-Il;Yoo, Jun-Yeol;Leem, Dae-Ho;Shin, Hyo-Keun;Ko, Seung-O
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.6
    • /
    • pp.420-425
    • /
    • 2009
  • Purpose: The aim of this study is to analyze the correlation between incidence of mandibular angle fracture and eruption state of mandibular third molar using clinical and radiographic findings. Materials and Methods: The data were obtained from the clinical and radiographic records of 205 patients who visited the Department of Oral and Maxillofacial Surgery, Chonbuk National University Hospital for treatment of the mandibular fracture. Panoramic radiographies were taken for radiographic examination and the mandibular third molars were classified according to age, gender, position and eruption state. Data were analyzed by a chi-square statistics. Results: In this study, the incidence of mandibular angle fracture had a tendency to be greater when a mandibular third molar was present(p>0.05), but there was not a statistically significant difference. Of the 255 cases with a mandibular third molar, 67 had an angle fractures. Of the 155 cases without a mandibular third molar, 138 had not angle fracture. And the incidence of mandibular angle fracture was high at class BII(by Pell & Gregory system)(p<0.05). Conclusion: Although there was not a statistically significant difference, mandibular third molar was more susceptible to mandibular angle fracture. When the reduction of mandibular angle fracture, it was recommended that mandibular third molar should be extracted especially in case of pericoronitis, periodontitis and other infections.

A Fundamental Study on the Fracture Mechanism of Steel Plates under Completely Alternating Load (완전교번하중하(完全交番荷重下)에서의 강판(鋼板)의 파괴기구(破壞機構)에 관한 기차적(基磋的) 연구(研究))

  • Chang, Dong Il;Chung, Yeong Wha
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.3
    • /
    • pp.1-13
    • /
    • 1982
  • Transition process of plastic region. displacements, stresses and strains ahead the flaw tips were analysed by the finite element method on the steel plate with the circular hole and the one with the elliptical hole under completely alternating load (repetition of tensile loading, unloading and compressive loading). As the results, the followings were obtained. Transition process of elastic failure (yielding) region was estimated. From this the tendency was confirmed that the fracture would be initiated from ahead the flaw tip, and propagated along the $45^{\circ}$ direction. The fundamental data available in estimating the stress intensity factor that was considered as the core in analysing the fracture mechanism of steel plates were obtained. It was indicated that when unloading after tension the effect of compressive loading, and even the compressive reyield, was occured ahead the flaw tip. Similarly it was indicated that when unloading after compression the effect of tensile loading, and even the tensile reyield, was occured ahead the flaw tip. It was considered that these phenomena were occured because the unloading effect was constrained by the residual strains when unloading. It was considered that the fatigue phenomenon was occured ahead, the flaw tip by repetition of tensile yield, the above compressive reyield, compressive yeild and the above tensile reyield. In addition, the tendency was confirmed that the fracture ahead the flaw tip was occured as the flaw was changed from the circular hole to the elliptical hole and became to be the crack lastly.

  • PDF

EFFECT OF RESIN MATRIX ON DEGREE OF CONVERSION AND FRACTURE TOUGHNESS OF DENIAL COMPOSITES (기질레진의 조성에 따른 복합레진의 물리적 성질에 관한 연구)

  • Lee, Yun-Shin;Choi, Kyoung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.77-86
    • /
    • 2002
  • Current composites are made with dimethacrylate monomers and silane-treated silica microfillers, either alone or with silane treated glass fillers The main reasons for clinical failure of dental composites are secondary caries, wear and fracture. Most of practitioner want to get a composite which is more tougher under occlusal stress, less polymerization contraction, and better handling properties in application clinically. The aim of this study was to investigate the influence of resin matrix with various flows on the physical proper-ties such as fracture toughness and degree of conversion of the experimental resins. It was hypothesized that flexible or tough resin composites can be designed by judicious choice of monomer composition Various flow resin matrices containing Bis-GMA, UDMA, and TEG-DMA were made by altering the pro-portion of the monomers. After the unfilled resins were light-cured for different light intensity, the fracture toughness(K$_{1c}$) was measured according to ASTM standard using the single edge notched geometry, and degree of conversion(DC) was measured by FTIR. And experimental composites were formulated with variations in the proportion of silanated quartz and strontium glass fillers as 60, 75, and 77wt%. Also, the physical properties of composites with various filer contents were evaluated as same manner. All resulting data were compared by ANOVA/Tukeys test at 0.05 level. The results were as follows; 1. The degree of conversion of high flow resin containing less Bis-GMA was higher than that of low flow unfilled resin 2. While the degree of conversion of unfilled resin was increased according to light intensity for polymerization, there was no significant increase with moderate and high light intensity. Also, the fracture toughness was not increased by high light intensity. 3. The fracture toughness was high in the low flow unfilled resin containing higher contents of Bis-GMA. 4. There was a significant increase for fracture toughness and a tendency for degree of conversion to be reduced when the content of fillers was increased. 5. In the experimental composites, the flow of resin matrix did not affected on the fracture toughness, even, which was decreased as increase of viscosity. These results showed that the physical properties of a dental composite could be attributed to the flow of resin matrix with relative content of monomers. Specific combination of resin monomers should be designed to fulfil the needs of specific indication for use.

A Study on the Bainite Phase Control of Direct-Quenched Low Carbon Steels (저탄소 직접 소입강의 베이나이트상 조절에 관한 연구)

  • An, Byeong-Gyu;Go, Yeong-Sang;Lee, Gyeong-Seop
    • Korean Journal of Materials Research
    • /
    • v.6 no.8
    • /
    • pp.841-851
    • /
    • 1996
  • In a recent investigation, the formation of bainite phase in direct-quenched low carbon non heat-treated steel was reported. In this study the effects of bainite phase on the mechanical properties of direct-quenched microalloying steels were investigated. By isothermal transformation at $480^{\circ}C$ for 7 sec., volume fraction of bainite lath was 15~20%, and the UTS and impact energy were increased. In this case $B_{ll}$ and $B_{lll}$ type bainite was observed and the fractography of impact test specimen showed a ductile fracture tendency. Isothermal transformation for 100sec., yielded 30% volume fraction of granular bainite and the mechanical properties were decreased. The f ractography of impact test specimen showed a brittle fracture tendency. The addition of Mo was more effective than B for improving impact energy because amounts of boron aditions were restricted to considerably lower levels, typically 10~ 30ppm. From this study, it is predicted that 15~20% volume fraction of lath bainite on the direct quenching process is procduced by addition of Mo up to 1.2wt. % and controlling the finish forging proc¬ess at $1000^{\circ}C$ and using oil as direct quenching media. This will improve mechanical properties of the direct- quenched steel.

  • PDF

Seismic behavior of thin cold-formed steel plate shear walls with different perforation patterns

  • Monsef Ahmadi, H.;Sheidaii, M.R.;Tariverdilo, S.;Formisano, A.;De Matteis, G.
    • Earthquakes and Structures
    • /
    • v.20 no.4
    • /
    • pp.377-388
    • /
    • 2021
  • Thin perforated Steel Plate Shear Walls (SPSWs) are among the most common types of seismic energy dissipation systems to protect the main boundary components of SPSWs from fatal fractures in the high-risk zones. In this paper, the cyclic behavior of the different circular hole patterns under cyclic loading is reported. Based on the experimental results, it can be concluded that a change in the perforation pattern of the circular holes leads to a change in the locations of the fracture tendency over the web plate, especially at the plate-frame interactions. Accordingly, the cyclic responses of the tested specimens were simulated by finite element method using the ABAQUS package. Likewise, perforated shear panels with a new perforation pattern obtained by implementing Topology Optimization (TO) were proposed. It was found that the ultimate shear strength of the specimen with the proposed TO perforation pattern was higher than that of the other specimens. In addition, theoretical equations using the Plate-Frame Interaction (PFI) method were used to predict the shear strength and initial stiffness of the considered specimens. The theoretical results showed that the proposed reduced coefficients relationships cannot accurately predict the shear strength and initial stiffness of the considered perforated shear panels. Therefore, the reduced coefficients should be adopted in the theoretical equations based on the obtained experimental and numerical results. Finally, with the results of this study, the shear strength and initial stiffness of these types of perforated shear panels can be predicted by PFI method.

RETROSPECTIVE STUDY FOR PROGNOSIS AFTER OPEN AND CLOSED REDUCTION OF THE MANDIBULAR CONDYLE FRACTURES (하악골 과두 골절의 관혈적 정복술과 비관혈적 정복술의 예후에 관한 후향적 연구)

  • Kim, Byoung-Soo;Lee, Jae-Hoon;Kim, Chul-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.4
    • /
    • pp.372-380
    • /
    • 2005
  • Condylar process of mandible, has the specialized anatomic structure compared with any other body structure, acts directly in connection with mastication and speech and so on. In general, mandibular condyle fractures have been managed by two methods as open and closed reduction. But, there are no reasonable consensus about the proper management of this injury. This study was designed for analysis of the prognosis of two methods of treatment, open and closed reduction, with positional change of fractured condyle and complications within 6 months post-intermaxillary fixation period. We conducted a retrospective analysis of 154 patients whose unilateral mandibular condyle fractures were treated by open or closed reduction in our department. The horizontal, sagittal, and coronal change of the condyle was examined using modified Towne's and panoramic radiographs before intermaxillary fixation(IMF), immediately after IMF, and at 6 months after IMF. Patients, whose mandibular condyle fractures were treated by closed reduction, had significantly shorter ramus height on the side of injury(P<0.05). But, fractured condylar fragments were displaced insignificantly with aspect to sagittal and coronal plane(P>0.05). The level of the fracture influenced the ramus length and the degree of coronal change in the closed reduction group(P<0.05). There was no significant correlation among the level of the fracture, treatment methods and complications(P>0.05). From the results obtained in this study, fractured mandibular condyles, were treated by closed reduction, had a tendency that continuous condylar displacement was occurred with aspect to horozontal and coronal plane in treatment period including intermaxillary fixation. And then there was a correlation between the level of the fracture and the position change in close reduction group statistically. These result suggested that care must be taken in basing treatment decisions on the degree of displacement of the condyle and in treating the mandibular condyle fractures for a long time.

A comparison of the shear bond strength between porcelain repair systems and fractured surface of porcelain-fused-to-metal restorations (도재파절 양상에 따른 수종의 도재 수복용 레진의 결합력에 관한 실험적 연구)

  • Choi, Jeung Won;Han, Dong Hoo;Jeong, Chang Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.147-163
    • /
    • 1990
  • Although dental porcelain demonstrates lasting esthetic results, it suffers from inherent brittle fractures. Various techniques and materials for intraoral porcelain repair has been suggested. This study investigated the in vitro shear strength of three porcelain repair systems according to aspects of the porcelain fractures. The purpose of this study was to evaluate the shear bond strength of three porcelain repair systems(All-bond, Clearfil, Scotchprime) according to fractured surface of porcelain - fused - to - metal restorations. For this study specimens were divided into five groups : group 1 represented fracture occurred at body porcelain layer, group 2 represented fracture occurred at opaque porcelain layer, group 3 represented fracture including 1/3 of metal exposure, group 4 represented fracture including 2/3 of metal exposure, and group 5 represented all metal surface was exposed. Specimens were stored in double deionized water(24Hr, $37^{\circ}C$) and thermocycling was performed(24Hr, 1080cycles), and subjected to a shear force parallel to the repair resin and porcelain interface by use of an University Testing Machine. The results of this study were obtained as follows : 1. In group 1 and 2, bond strength was relatively high, and bond strength showing reducing tendency as exposure of metal was increased. 2. In group 1, bond strength was relatively high, and no significant differences in porcelain repair system. 3. In group 2, 3 and 4, All-bond and Clearfil provided significantly higher bond strength than scotchprime. 4. In group 5, bond strength was the lowest among all groups and especially in case if Scotchprime. 5. Cohesive failure was observed in group 1 and 2, adhesive failure was observed in group 5, and cohesive / adhesive failures were observed in group 3 and 4.

  • PDF