• Title/Summary/Keyword: fracture repair

Search Result 254, Processing Time 0.03 seconds

An experimental study of simplified denture repair technique (간단한 의치수리방법에 관한 실험적 연구)

  • Park, Yong-Deuk
    • Journal of Technologic Dentistry
    • /
    • v.2 no.1
    • /
    • pp.31-33
    • /
    • 1980
  • 의치(denture) 파절조각(fracture segment)의 조립을 정확하고 쉽게 부착시킬 수 있는 cyanoacrylate의 사용을 권장하고 싶다. 이 수리 방법은 환자가 오랜기간 동안 보철물 없이 존속하는 것을 막기 위해 석고모형(stone cast)을 부울 필요없이 신속하게 수리하는 방법이다. 더불어 의치(denture)가 많은 조각으로 파절 되었기 때문에 전통적인 방법에 의해서는 수리가 가능치 않다고 생각 될 경우에는 이 방법이 좋으리라 생각되어 소개하는 바 입니다.

  • PDF

Effects of different calcium-silicate based materials on fracture resistance of immature permanent teeth with replacement root resorption and osteoclastogenesis

  • Gabriela Leite de Souza;Gabrielle Alves Nunes Freitas;Maria Tereza Hordones Ribeiro;Nelly Xiomara Alvarado Lemus;Carlos Jose Soares;Camilla Christian Gomes Moura
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.21.1-21.15
    • /
    • 2023
  • Objectives: This study evaluated the effects of Biodentine (BD), Bio-C Repair (BCR), and mineral trioxide aggregate (MTA) plug on the fracture resistance of simulated immature teeth with replacement root resorption (RRR) and in vitro-induced osteoclastogenesis. Materials and Methods: Sixty bovine incisors simulating immature teeth and RRR were divided into 5 groups: BD and BCR groups, with samples completely filled with the respective materials; MTA group, which utilized a 3-mm apical MTA plug; RRR group, which received no root canal filling; and normal periodontal ligament (PL) group, which had no RRR and no root canal filling. All the teeth underwent cycling loading, and compression strength testing was performed using a universal testing machine. RAW 264.7 macrophages were treated with 1:16 extracts of BD, BCR, and MTA containing receptor activator of nuclear factor-kappa B ligand (RANKL) for 5 days. RANKL-induced osteoclast differentiation was assessed by staining with tartrate-resistant acid phosphatase. The fracture load and osteoclast number were analyzed using 1-way ANOVA and Tukey's test (α = 0.05). Results: No significant difference in fracture resistance was observed among the groups (p > 0.05). All materials similarly inhibited osteoclastogenesis (p > 0.05), except for BCR, which led to a lower percentage of osteoclasts than did MTA (p < 0.0001). Conclusions: The treatment options for non-vital immature teeth with RRR did not strengthen the teeth and promoted a similar resistance to fractures in all cases. BD, MTA, and BCR showed inhibitory effects on osteoclast differentiation, with BCR yielding improved results compared to the other materials.

The Effect of Low-Intensity Pulsed Ultrasound on Fracture Healing in the Rabbit Model (토끼모델에서 저강도 맥동초음파가 골절치유에 미치는 영향)

  • Kim, Jong-Man;Yi, Chung-Hwi;Cho, Sang-Hyun;Park, Jung-Mi;Kwon, Hyuk-Cheol;Hwang, Tae-Sun
    • Physical Therapy Korea
    • /
    • v.9 no.1
    • /
    • pp.81-96
    • /
    • 2002
  • The purpose of this research was to determine the effects on the healing of fibular fractures in rabbits of low-intensity pulsed ultrasound (50 $mW/cm^2$ and 500 $mW/cm^2$) applied for periods of 4, 14 and 24 days following fibular osteotomy. Thirty-six male Japanese white rabbits were randomly divided into three groups of twelve for three treatment protocols: (1) ultrasound treatment at intensities of 50 $mW/cm^2$ and 500 $mW/cm^2$ until the 4th day following fibular osteotomy, (2) ultrasound treatment at intensities of 50 $mW/cm^2$ and 500 $mW/cm^2$ until the 14th day following fibular osteotomy, and (3) ultrasound treatment at intensities of 50 $mW/cm^2$ and 500 $mW/cm^2$ until the 24th day following fibular osteotomy. The low-intensity pulsed ultrasound was applied to only one fibula of each rabbit (these served as the experimental group). The other fibula of each rabbit served as the control group. The selection of which fibula was to be treated was made randomly. The animals were sacrificed on the 4th, 14th and 24th day after the start of ultrasound treatments. Percent of trabecular bone area and fibular radiography were carried out to compare the degree of fibular bone healing. A microscope was also used to determine any histologic changes. For statistical differences in radiological changes due to length of treatment period (4, 14 and 24 days respectively), the Wilcoxon signed-ranks test was used to compare the experimental and control groups. For statistical differences in fracture healing due to differences in ultrasound intensity, radiological studies were compared using the Mann-Whitney Test. And, to compute percentage differences in areas of trabecular bone, Two-way analysis of variance (ultrasound intensity x each group) was used. Experiment results were as follows: 1. In animals sacrificed on the 4th day, no difference was found in the radiological studies of the fibulae in the experimental and control groups (p>.05). However, experimental groups showed more rapid bone repair than control group. 2. Both radiographic and percent of trabecular bone area studies showed significant differences in rabbits sacrificed after 14 days. Fracture healing was significantly increased in the experimental group (p<.05) 3. In the animals sacrificed on the 24th day, histologic study showed rapid bone repair but fibular radiologic studies did not show statistical differences between the two groups (p>.05). 4. On the 14th day, bone union on radiograph was significantly more rapid in the treatment group with pulsed ultrasound of 50 $mW/cm^2$ than the group with 500 $mW/cm^2$ (p<.05). Histologic studies showed that both the 14 and 24 days groups had more rapid bone repair in animals treated with 50 $mW/cm^2$ ultrasound intensity than those treated with 500 $mW/cm^2$ intensity. In conclusion, it has been shown that the low-intensity pulsed ultrasound has a positive effect on bone fracture healing in the early stage and the range of pulse ultrasound from 50 $mW/cm^2$ to 500 $mW/cm^2$ is effective for fracture healing. Further study is needed to investigate the influence of pulsed ultrasound on delayed union and non-union in bone fractures and also for the clinical use of low-intensity pulsed ultrasound for bone healing in humans.

  • PDF

Arthroscopic Treatment of Osteochondral Fractures Associated with Patella Dislocation (슬개골 탈구에 동반된 골연골 골절의 관절경적 치료)

  • Lee Byung-Ill;Min Kyung-Dae;Choi Hyung-Suk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.104-110
    • /
    • 2001
  • Purpose : To analyze the patterns of osteochondral fracture associated with patellar dislocation and to assess the results of arthroscopic treatment. Materials and Methods : Fourteen patients were treated from March, 1989 to April, 1998 for patellar dislocations with osteochondral fracture. The average follow-up was 32 months. All were treated by arthroscopic procedures. The location and size of the fracture fragments were recorded. To assess the functional results, we used Larsen & Lauridson's score system. Results : Osteochondral fractures were found 8 cases in medial side of patella, 1 case in lateral side of patella, 5 cases in lateral margin of lateral femoral condyle. The range of maximal diameter of osteochondral fragment was from 1cm to 4.2cm. Treatments include fragment excision only in 6 cases, excision and medial retinacular repair in 2 cases, excision and medial retinacular repair and lateral retinacular release in 3 cases, and internal fixation only in 3 cases. The functional results were excellent in 5 cases$(36\%)$. good in 6 cases$(43\%)$, fair in 1 case$(7\%)$ and poor in 2 cases$(14\%)$. Conclusion : In osteochondral fractures associated with patellar dislocation, arthroscopic treatment is useful to diagnose precisely, to determine proper treatment modality, and to minimize the complications.

  • PDF

Treatment of Pseudoarthrosis due to Nonunion of the Acromial Fracture with LCP - Case Report - (견봉 골절의 불유합으로 기인한 가관절증의 잠김 금속판을 이용한 치료 - 증례보고 -)

  • Kim, Yong-Min;Park, Kyoung-Jin;Kim, Dong-Soo;Choi, Eui-Sung;Shon, Hyun-Chul;Cho, Byung-Ki;Park, Ji-Kang;Keum, Sang-Wook;Jeong, Ho-Seung
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.130-134
    • /
    • 2013
  • A painful pseudoarthrosis will develop due to a delay in diagnosis and treatment, and surgical care is required. Treatment of pseudoarthrosis is really difficult because the acromion is a thin flat bone that is difficult to be fixed firmly. A 52-year-old woman with multiple trauma had an acromial fracture that was not detected until it had caused pain after ambulation. Open reduction and internal fixation with a variable angle locking compression plate for distal radius and autogenous iliac bone graft were performed. At nine months after the operation, there was partial tear in the supraspinatus tendon, and arthroscopic repair of the supraspinatus tendon was performed. At nine months after the operation, radiographs showed a complete union. At three months after tendon repair, the patient had excellent function of the shoulder. We have reported a case of a successful treatment of nonunion and pseudoarthrosis of acromial fracture that is difficult to be fixed.

A comparison study on shear bond strength of 3D printed resin and conventional heat-cured denture base resin to denture relining materials (3D-프린팅 의치상 레진과 열중합 의치상 레진에서의 의치 첨상 재료 간의 전단결합강도 비교 연구)

  • Cho, Sung-Yoon;Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.232-243
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the shear bond strength of various 3D printed denture base resins and the conventional denture base resin to various denture relining materials. Materials and Methods: For denture base materials, a heatcured (Vertex RS) and two types of 3D printed DENTCA Denture base II, NextDentTM Base) were used. And 4 types denture relining materials (Tokuyama Rebase II fast, Kooliner, Denture Liner, Denture Liner, Lang Jet Denture Repair Kit) with different components were used. It was classified into 12 groups. Adhesion was performed between the resin base and the relining materials in accordance with ISO/TS 11405 standard. The shear bonding strength was measured, and then the adhesion interface was observed with a stereoscopic microscope and a scanning electron microscope. The fracture pattern was investigated through the analysis of the fragment. Results: In the 3D printed denture resin group, the shear bonding strength with relining materials was significantly lower than that of the heat-cured resin group (P < 0.05). The group of polymethyl methacrylate -based relining materials, high shear bonding strength was shown regardless of the type of denture. As for the fracture pattern, adhesive fracture appeared in most groups, and cohesive, mixed fracture appeared in some groups. Conclusion: The polymethyl methacrylate -based denture relining materials showed high shear bonding strength values compared to other denture relining materials. But, for direct methods, it is considered advantageous in terms of shear bonding strength to use a isobutyl methacrylate-based denture relining materials.

Effect of Deltoid Ligament Repair on Syndesmotic Stabilization in Patients with Ankle Fractures (발목 골절 환자에서 삼각인대봉합술이 원위경비인대결합에 미치는 영향)

  • Dae-Wook Kim;Hong Joon Choi
    • Journal of Korean Foot and Ankle Society
    • /
    • v.27 no.2
    • /
    • pp.58-66
    • /
    • 2023
  • Purpose: This study aimed to evaluate the effectiveness of deltoid ligament repair on syndesmotic stabilization in patients with acute ankle fractures with ruptured deltoid and syndesmotic ligaments. Materials and Methods: The medical records of 41 patients (41 ankles) who underwent surgery for Weber type B ankle fracture with ruptured deltoid and syndesmotic ligaments were retrospectively analyzed. The mean follow-up duration was 36 months (range 18~65 months). Patients were divided into two groups: those that underwent deltoid ligament repair (the deltoid group) and those who did not (the non-deltoid group). Both groups were also divided into two subgroups, namely, the D1/S1 group, which underwent syndesmotic screw fixation, or the D2/S2 group, which did not. Medial clear space (MCS), tibiofibular clear space (TFCS), anterior fibular line (AFL) ratio, and posterior fibular line (PFL) distance were measured, and visual analog scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS), and Foot Function Index (FFI) scores were evaluated. Results: TFCS changed significantly after surgery in the D2 and S1 groups (p=0.01, p=0.03, respectively). Subgroup MCSs, TFCSs, and AFL ratios were not significantly altered by surgery in the four subgroups (p=0.82, p=0.45, p=0.25, respectively). However, postoperative PFL distances were significantly different in the D2 and S1 groups and the S1 and S2 groups (p=0.02, p=0.02, respectively). Mean TFCS decreased significantly after surgery in the D2 and S1 groups. The postoperative VAS, AOFAS scores, and FFI were not significantly different between the subgroups (p=0.44, p=0.40, and p=0.46, respectively). Conclusion: Deltoid ligament repair seemed to restore ankle stability without addressing syndesmosis in Weber type B ankle fractures with rupture of deltoid and syndesmotic ligaments.

Lower Eyelid Retraction and Scleral Show induced by Subciliary Approach in Inferior Orbital Rim Fracture (안와하연 골절에서 눈썹하절개 경로를 통한 접근 후 발생하는 하안검 뒤당김과 공막의 노출)

  • Park, Yong Joon
    • Archives of Plastic Surgery
    • /
    • v.34 no.6
    • /
    • pp.724-728
    • /
    • 2007
  • Purpose: The objective of this study is to prevent postoperative lower eyelid retraction and scleral show. There are several approaches for orbital rim reconstruction. But these techniques are sometimes difficult to perform, and have some merits and faults. Maybe most common unwanted and unpleasant result that we have experienced by subciliary incision preseptal approach is the lower eyelid retraction and the scleral show. Therefore, I want to find out the causes and the solutions for such complication. We must know the mechanics for those unpleasant result first of all. Methods: We conducted a comparison of postoperative photographs between retroseptal approach group and preseptal approach group, both with subciliary incision. In experimental retroseptal group, incision was applied at subciliary region. After elevating skin flap to preserve pretarsal muscle, not with muscle flap elevation, but direct oblique incision through the muscle, retroseptal dissection was applied to the ROOF and the septum. Fixating fracture line, periosteal and septal repair was followed by skin repair. The light compressive dressings and protection were kept in place for 7 days. The effectiveness of this operative method was made comparison with control group which the preseptal approach was applied to, by postoperative 2nd week and 2nd month. Results: Author's technique had been used in 20 patients and control group was composed of 50 patients over 19months period. There were better results in experimental group than in control group and all of experimental group had no complaint about the lower eyelid retraction and the scleral show. Conclusion: It must be known about the reason of the lower eyelid retraction and the scleral show induced by subciliary and preseptal approach. Mechanically it can be easily proved. And the solution maybe will be easier if we get more information about the mechanics. I recommend the retroseptal subciliary approach

Proposal of Concrete Pull Off Bond Strength Measurement Method for Bridge Deck Overlay (교면 덧씌우기 콘크리트의 인발부착강도(引拔附着强度) 시험법(試驗法) 제안(提案))

  • Kim, Seong-Hwan;Kim, Dong-Ho;Kim, Hyun-Oh;Lee, Bong-Hak
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.149-156
    • /
    • 2003
  • The development and maintenance of a sound bond are essential requirements of concrete repair and replacement. The bond property of a overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials, but no test method has been adopted as a standard. In this study, a concrete pull off bond strength measurement method for field application is proposed and evaluated. This study compares the splitting tensile test, slant shear test, nipple pipe direct tensile test, flexural adhesion test, briquette tensile test, jumbo nail pull-out test and core pull-off test with their test procedures. From these comparison and investigation, core pull-off test is selected as a main topic of this study because of it's suitability for in situ testing, simplicities in field application and clearness at interface boundary condition. Thus, the proposed core pull off test is evaluated to be the most appropriate method for field application in a simple manner. The fracture surface and fracture mode could be easily determined by visual observation of failure surface of the field specimen. The core pull off test was found to be sensitive to surface condition and latex contents at latex modified concrete.

  • PDF

Effect of delayed time, surface treatment, and repair material on shear bond strength of repaired bis-acryl composite resin (수리된 비스 아크릴 복합 레진의 전단결합강도에 대한 지연시간, 표면처리, 수리 재료의 영향)

  • Park, Ji-su;Lee, Jae-In
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.89-96
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the effect of delayed time, surface treatment, and repair materials on repair of bis-acryl composite resin through comparison of shear bond strength and to evaluate the utility of bis-acryl composite resin repair using polymethyl methacrylate resin. Materials and Methods: A total of 90 bis-acryl composite resin specimens were fabricated and classified into 9 test groups, each of 10 pieces according to delayed time, surface treatment and repair material. The shear bond strength of each specimen was measured using a universal testing machine immediately after fabrication and analyzed using a statistical analysis program (IBM SPSS statistics 20). After the shear bond strength measurement, the fracture surface of the specimen was observed. Results: The highest shear bond strength ($17.54{\pm}3.14MPa$) was observed in the experimental group bonded immediately with a light-curing flowable composite resin using a bonding agent. Conclusion: When repairing bis-acryl composite resin, it is necessary to consider whether to remake according to the delayed time. For effective repair, it is desirable to consider appropriate materials and surface treatment methods according to the site or purpose of use.