• 제목/요약/키워드: fracture potential

Search Result 357, Processing Time 0.15 seconds

Delayed Orbital Hemorrhage around Alloplastic Implants after Blowout Fracture Reduction

  • Ryu, Yong Ah;Park, Jae Beom;Kyung, Hyun Woo;Song, Seung Han;Kang, Nak Heon
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.1
    • /
    • pp.35-38
    • /
    • 2015
  • Alloplastic implants have been used to repair orbital wall fractures in most cases. Orbital hemorrhage is a rare complication of these implants and has been reported rarely in Korea. The purpose of this article is to report a late complication case focusing on their etiology and management. A 20-year-old male patient underwent open reduction with Medpor (porous polyethylene) insertion for bilateral orbital floor fractures. The initial symptom occurred with proptosis in the right side as well as vertical dystopia, which had started 4 days earlier, 8 months after surgery. Any trauma history after the surgery was not present. We performed an exploration and removal of hematoma with Medpor titanium meshed alloplastic implant. A case of delayed orbital hematoma following alloplastic implant insertion was identified. It occurred within the pseudocapsule of the implant. One week after surgery, overall symptoms improved successfully, and no complications were reported during the 11-month follow-up period. Although rare, orbital hemorrhage is a potential complication of alloplastic orbital floor implants, which may present many years after surgery. As in the case presented, delayed hematoma should be included in the differential diagnosis of late proptosis or orbital dystopia.

Evaluation of Crack Propagation in Silicon Anode using Cohesive Zone Model during Two-phase Lithiation (접착영역 모델을 사용한 2상 리튬 이온 충전 시 실리콘 음극 전극의 균열진전 해석)

  • Kim, Yong-Woo;Han, Tong-Seok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.5
    • /
    • pp.297-304
    • /
    • 2019
  • In this research, crack propagation in a silicon anode during two-phase lithiation was evaluated using a cohesive zone model. The phase transition from crystalline silicon to lithiated silicon causes compressive yielding due to the high volume expansion rate. Li-ion diffuses from the surface of the silicon to its core, and the complex deformation mechanisms during lithiation cause tensile hoop stress along the surface. The Park-Paulino-Roesler (PPR) potential-based cohesive zone model that guarantees consistent energy dissipation in mixed-mode fracture was adopted to simulate edge crack propagation. It was confirmed that the edge crack propagation characteristics during lithiation from the FEM simulation results coincided with the real experimental results. Crack turning observed from real experiments could also be predicted by evaluating the angles of maximum tensile stress directions.

A working paradigm for managing mandibular fractures under regional anesthesia

  • Chellappa, Natarajan;Meshram, Vikas;Kende, Prajwalit;Landge, Jayant;Aggarwal, Neha;Tiwari, Manish
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.6
    • /
    • pp.275-281
    • /
    • 2018
  • Objectives: Isolated mandibular fractures contribute to approximately 45% of maxillofacial traumas. Improper management of mandibular fractures can cause myriad potential complications and can lead to serious functional and aesthetic sequelae. The objective of the study is to design a stepwise approach for managing isolated mandibular fractures using open reduction and internal fixation (ORIF) with regional anesthesia on outpatient basis. Materials and Methods: Patients with isolated mandibular fractures presenting to the department of maxillofacial surgery were selected for ORIF under regional anesthesia based on occlusion, age, socioeconomic status, general condition, habits, and allied medical ailments. Standard preoperative, intraoperative, and postoperative protocols were followed. All patients were followed up for a minimum of 4 weeks up to a maximum of 1 year. Results: Of 23 patients who received regional anesthesia, all but one had good postoperative functional occlusion. One patient was hypersensitive and had difficulty tolerating the procedure. Two patients developed an extraoral draining sinus, one of whom was managed with local curettage, while the other required hardware removal. One patient, who was a chronic alcoholic, returned 1 week after treatment with deranged fracture segments after he fell while intoxicated. Conclusion: With proper case selection following a stepwise protocol, the majority of mandibular fractures requiring ORIF can be managed with regional anesthesia and yield minimal to no complications.

Effects of Solution Treatment Temperatures on Microstructure and Mechanical Properties of TIG-MIG Hybrid Arc Additive Manufactured 5356 Aluminum Alloy

  • Zuo, Wei;Ma, Le;Lu, Yu;Li, Shu-yong;Ji, Zhiqiang;Ding, Min
    • Metals and materials international
    • /
    • v.24 no.6
    • /
    • pp.1346-1358
    • /
    • 2018
  • A novel additive manufacturing method with TIG-MIG hybrid heat source was applied for fabricating 5356 aluminum alloy component. In this paper the microstructure evolution, mechanical properties and fracture morphologies of both as-deposited and heat-treated component were investigated, and how these were affected by different heat-treated temperature. The as-deposited microstructure showed dominant equiaxed grains with second phase, and the size of them is coarse in the bottom region, medium in the middle region and fine in the top region owing to different thermal cycling conditions. Compared with as-deposited microstructure, the size of grain becomes large and second phases gradually dissolve in the matrix as heat-treated temperature increase. Different microstructures determine the mechanical properties of component. Results show that average ultimate tensile strength enhances from 226 to 270 MPa and average microhardness increases from 64.2 to 75.3 HV0.1 but ductility decreases from 33 to 6.5% with heat-treated temperature increasing. For all components, the tensile properties are almost the same in the vertical direction (Z) and horizontal direction (Y) due to equiaxed grains, which exhibits isotropy, and the mechanisms of these are analyzed in detailed. In general, the results demonstrate that hybrid arc heat source has the potential to fabricate aluminum alloy component.

Clinical factors in patients with congenital muscular torticollis treated with surgical resection

  • Kim, Sue Min;Cha, Bohwan;Jeong, Kwang Sik;Ha, Non Hyeon;Park, Myong Chul
    • Archives of Plastic Surgery
    • /
    • v.46 no.5
    • /
    • pp.414-420
    • /
    • 2019
  • Background Congenital muscular torticollis (CMT) is characterized by persistent head tilt toward the affected side. No consensus exists regarding the cause of this disorder. In this study, we analyzed various clinical factors in patients with CMT who were treated with surgical release. This analysis enabled us to identify potential causative factors of CMT and to establish a basis for surgical interventions. Methods In total, 584 patients who underwent surgical intervention for CMT from October 2007 to December 2016 were included in this study. Their demographic characteristics, birthrelated factors, and clinical features were analyzed. Results Data from 525 patients were analyzed in this study after exclusion of those with insufficient information. Before birth, 31 patients (5.9%) were diagnosed with oligohydramnios, and 87 (16.6%) had a breech presentation. Seven (1.3%) cases of clavicle fracture and two (0.4%) cases of cephalohematoma were noted at birth. Before surgery, 397 patients (75.6%) underwent physiotherapy and 128 patients (24.4%) did not. The duration of physiotherapy ranged from 1 to 50 months (average, 6 months). Conclusions Our study shows that 16.6% of the CMT patients presented in the breech position, which is a much higher rate than that observed in the general population (3%-4%). We hypothesize that being in the breech position as a fetus appears to exert a significant influence on shortening and fibrosis of the sternocleidomastoid muscle.

Static behavior of high strength friction-grip bolt shear connectors in composite beams

  • Xing, Ying;Liu, Yanbin;Shi, Caijun;Wang, Zhipeng;Guo, Qi;Jiao, Jinfeng
    • Steel and Composite Structures
    • /
    • v.42 no.3
    • /
    • pp.407-426
    • /
    • 2022
  • Superior to traditional welded studs, high strength friction-grip bolted shear connectors facilitate the assembling and demounting of the composite members, which maximizes the potential for efficiency in the construction and retrofitting of new and old structures respectively. Hence, it is necessary to investigate the structural properties of high strength friction-grip bolts used in steel concrete composite beams. By means of push-out tests, an experimental study was conducted on post-installed high strength friction-grip bolts, considering the effects of different bolt size, concrete strength, bolt tensile strength and bolt pretension. The test results showed that bolt shear fracture was the dominant failure mode of all specimens. Based on the load-slip curves, uplifting curves and bolt tensile force curves between the precast concrete slab and steel beam obtained by push-out tests, the anti-slip performance of steel-concrete interface and shear behavior of bolt shank were studied, including the quantitative analysis of anti-slip load, and anti-slip stiffness, frictional coefficient, shear stiffness of bolt shank and ultimate shear capacity. Meanwhile, the interfacial anti-slip stiffness and shear stiffness of bolt shank were defined reasonably. In addition, a total of 56 push-out finite element models verified by the experimental results were also developed, and used to conduct parametric analyses for investigating the shear behavior of high-strength bolted shear connectors in steel-concrete composite beams. Finally, on ground of the test results and finite element simulation analysis, a new design formula for predicting shear capacity was proposed by nonlinear fitting, considering the bolt diameter, concrete strength and bolt tensile strength. Comparison of the calculated value from proposed formula and test results given in the relevant references indicated that the proposed formulas can give a reasonable prediction.

Preparation and Refinement Behavior of (Hf-Ti-Ta-Zr-Nb)C High-Entropy Carbide Powders by Ultra High Energy Ball Milling Process (초고에너지 볼 밀링공정에 의한 (Hf-Ti-Ta-Zr-Nb)C 고엔트로피 카바이드 분말 제조 및 미세화 거동)

  • Song, Junwoo;Han, Junhee;Kim, Song-Yi;Seok, Jinwoo;Kim, Hyoseop
    • Journal of Powder Materials
    • /
    • v.29 no.1
    • /
    • pp.34-40
    • /
    • 2022
  • Recently, high-entropy carbides have attracted considerable attention owing to their excellent physical and chemical properties such as high hardness, fracture toughness, and conductivity. However, as an emerging class of novel materials, the synthesis methods, performance, and applications of high-entropy carbides have ample scope for further development. In this study, equiatomic (Hf-Ti-Ta-Zr-Nb)C high-entropy carbide powders have been prepared by an ultrahigh-energy ball-milling (UHEBM) process with different milling times (1, 5, 15, 30, and 60 min). Further, their refinement behavior and high-entropy synthesis potential have been investigated. With an increase in the milling time, the particle size rapidly reduces (under sub-micrometer size) and homogeneous mixing of the prepared powder is observed. The distortions in the crystal lattice, which occur as a result of the refinement process and the multicomponent effect, are found to improve the sintering, thereby notably enhancing the formation of a single-phase solid solution (high-entropy). Herein, we present a procedure for the bulk synthesis of highly pure, dense, and uniform FCC single-phase (Fm3m crystal structure) (Hf-Ti-Ta-Zr-Nb)C high-entropy carbide using a milling time of 60 min and a sintering temperature of 1,600℃.

Vitamin D in athletes: focus on physical performance and musculoskeletal injuries

  • Yoon, Sewoon;Kwon, Ohkyu;Kim, Jooyoung
    • Korean Journal of Exercise Nutrition
    • /
    • v.25 no.2
    • /
    • pp.20-25
    • /
    • 2021
  • [Purpose] The aim of this review was to discuss the effects of vitamin D on physical performance and musculoskeletal injuries in athletes and provide information on the field applications of vitamin D. [Methods] A systematic review was conducted to identify studies on vitamin D in athletes that assessed serum vitamin D levels, vitamin D and physical performance, vitamin D and musculoskeletal injuries, and practical guidelines for supplementation of vitamin D. [Results] Several studies reported that a high proportion of athletes had vitamin D insufficiency or deficiency. Low serum levels of vitamin D in athletes were more pronounced in winter than in other seasons, and indoor athletes had lower serum vitamin D levels than outdoor athletes. Low vitamin D levels have been demonstrated to have negative effects on muscle strength, power, and endurance; increase stress fractures and other musculoskeletal injuries; and affect acute muscle injuries and inflammation following high-intensity exercises. Therefore, periodic assessment and monitoring of vitamin D levels are necessary in athletes; the recommended serum level of 25(OH)D is > 32 ng/mL and the preferred level is > 40 ng/mL (-1). In those with low levels of vitamin D, exposure to sunlight and an improved diet or supplements may be helpful. Particularly, 2000-6000 IU of supplemental vitamin D3 can be consumed daily. [Conclusion] Vitamin D is a potential nutritional factor that can significantly affect physical performance and musculoskeletal injuries in athletes. The importance and role of vitamin D in athletes should be emphasized, and the current levels of vitamin D should be assessed. Therefore, it is essential to periodically evaluate and monitor serum vitamin D levels in athletes.

Resonance frequency analysis of 3D printed self-healing capsules for localization of self-healing capsules inside concrete using millimeter wave length electromagnetic waves (밀리미터 전자기파를 이용한 콘크리트 내부 자가치유 캡슐의 위치 측정을 위한 3D 프린팅 자가치유 캡슐의 공진 주파수 분석)

  • Lim, Tae-Uk;Cheng, Hao;Lee, Yeong Jun;Hu, Jie;Kim, Sangyou;Jung, Wonsuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.243-244
    • /
    • 2022
  • In this paper, experiments were conducted on signal amplification of polymer capsules for application to Ground Penetrating Radar so as to enable real-time monitoring of polymer capsules inside concrete using the Morphology Dependent Resonance phenomenon. A TEM CELL and a vector network analyzer were used to analyze the difference in resonance frequency depending on the material of the sphere and the presence or absence of fracture. In order to manufacture a capsule of a size that can be measured using millimeter waves used in GPR, we manufactured a capsule with a 3D printer and analyzed the effects of the presence or absence of coating and the size of the capsule on the resonance frequency. Resonant frequency or signal amplification is more affected by diameter than coating. The capsule showing the highest amplification is the resin-coated 50 mm diameter capsule with a 316-fold increase and the lowest capsule is the uncoated 10 mm diameter capsule with a signal amplification of 11.9 times. These results demonstrate the potential of GPR to measure the position and state of self-healing capsules, which are small-sized polymers, in real time using millimeter waves.

  • PDF

Protocol for management of pregnant patients requiring emergency minor oral surgical procedures: a prospective study in 52 patients

  • Ajinath Nanasaheb Jadhav;Shushma G;Uzma Hamidullah Siddiqui;Minal Sharma;Yaseer Irfan Shaikh;Pooja Raosaheb Tarte
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.1
    • /
    • pp.21-29
    • /
    • 2023
  • Objectives: Dental or maxillofacial emergencies are uncommon during pregnancy, but if they occur, they are challenging to treat due to potential risks. The mother should not be denied necessary medical or dental care because of pregnancy. The aim of the study is to observe outcomes of pregnancy in patients requiring emergency minor oral surgical procedures during gestation and to determine the safety of the pregnant woman undergoing the procedure and the fetus. Materials and Methods: The study was conducted on 52 pregnant women requiring emergency oral surgical procedures. A standard treatment protocol for treatment of specific entities was followed. Close monitoring and observation were the primary goal of treatment. All patients were followed postoperatively until complete recovery from the surgical procedures and then until birth of the baby. A control group of 52 healthy pregnant patients who did not require oral surgical procedures was considered for statistical analysis. The measurements to calculate observation were fetal loss (spontaneous abortion), preterm birth, low-birth weight, or incidence of any congenital anomalies in the baby and its association with surgical procedures. Results: No fetal loss occurred in any of the cases. However, four patients experienced preterm birth and seven neonates exhibited low birth weights. No congenital abnormalities were discovered. In one instance, a patient who underwent surgery for a mandibular symphysis fracture under general anesthesia in the 31st week of pregnancy experienced labor pain on the fourth postoperative day, requiring an emergency Caesarean section. Conclusion: The results of our study demonstrate that, compared to the control group, minor emergency surgeries performed during pregnancy have no discernible negative effects on the fetus. These procedures can safely be performed by adhering to our described protocols.