• Title/Summary/Keyword: fracture potential

Search Result 354, Processing Time 0.026 seconds

Atomistic simulations of nanocrystalline U0.5Th0.5O2 solid solution under uniaxial tension

  • Xiao, Hongxing;Wang, Xiaomin;Long, Chongsheng;Tian, Xiaofeng;Wang, Hui
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1733-1739
    • /
    • 2017
  • Molecular dynamics simulations were performed to investigate the uniaxial tensile properties of nanocrystalline $U_{0.5}Th_{0.5}O_2$ solid solution with the Born-Mayer-Huggins potential. The results indicated that the elastic modulus increased linearly with the density relative to a single crystal, but decreased with increasing temperature. The simulated nanocrystalline $U_{0.5}Th_{0.5}O_2$ exhibited a breakdown in the Halle-Petch relation with mean grain size varying from 3.0 nm to 18.0 nm. Moreover, the elastic modulus of $U_{1-y}Th_yO_2$ solid solutions with different content of thorium at 300 K was also studied and the results accorded well with the experimental data available in the literature. In addition, the fracture mode of nanocrystalline $U_{0.5}Th_{0.5}O_2$ was inclined to be ductile because the fracture behavior was preceded by some moderate amount of plastic deformation, which is different from what has been seen earlier in simulations of pure $UO_2$.

Computation of the Higher Order Derivatives of Energy Release Rates in a Multiply Cracked Structure for Probabilistic Fracture Mechanics and Size Effect Law (확률론적 파괴역학 및 Size Effect Law에 적용을 위한 다중 균열 구조물에서의 에너지 해방률의 고차 미분값 계산)

  • Hwang, Chan-Gyu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.4
    • /
    • pp.391-399
    • /
    • 2008
  • In this paper, we further generalize the work of Lin and Abel to the case of the first and the second order derivatives of energy release rates for two-dimensional, multiply cracked systems. The direct integral expressions are presented for the energy release rates and their first and second order derivatives. The salient feature of this numerical method is that the energy release rates and their first and second order derivatives can be computed in a single analysis. It is demonstrated through a set of examples that the proposed method gives expectedly decreasing, but acceptably accurate results for the energy release rates and their first and second order derivatives. The computed errors were approximately 0.5% for the energy release rates, $3\sim5%$ for their first order derivatives and $10\sim20%$ for their second order derivatives for the mesh densities used in the examples. Potential applications of the present method include a universal size effect model and a probabilistic fracture analysis of cracked structures.

Surgical Stabilization of Traumatic Medial Luxation of Scapulohumeral Joint and Scapular Fracture in a Dog (개에서 발생한 외상성 견관절 내측 탈구와 견갑골 골절의 외과적 교정 1 례)

  • Jang, Ha-Young;Lee, Bo-Ra;NamKung, May Hyo-Sun;Yoon, Hun-Young;Han, Hyun-Jung;Kim, Joon-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.26 no.3
    • /
    • pp.276-278
    • /
    • 2009
  • A 1 year 4 months old, male Poodle was presented with a history of non weight bearing lameness and pain of the right forelimb by trauma. Orthopedic examination and radiographs were revealed medial shoulder luxation and scapular fracture. Biceps tendon was translocated to the lesser tubercle and secured to the humerus. Despite of it could be a potential cause of degenerative change of the joint, a favorable result was achieved for more than 3 years follow-up.

Association of Common Vitamin D Receptor Gene Variations with Fracture Risk and Bone Mineral Density in Postmenopausal Korean Population

  • Hwang, Joo-Yeon;Lee, Seung Hun;Kim, Ghi-Su;Koh, Jung-Min;Go, Min-Jin;Kim, Tae-Ho;Hong, Jung-Min;Park, Eui-Kyun;Kim, Shin-Yoon;Lee, Jong-Young
    • Genomics & Informatics
    • /
    • v.7 no.1
    • /
    • pp.13-19
    • /
    • 2009
  • Osteoporosis is characterized by impaired osteogenesis. BMD is a major determinant of bone strength. The role of the VDR gene in predisposition to primary osteoporosis has been recognized. However, population-based case-control studies have been reported controversial results for known candidate genes in an ethnically distinct group. To determine the genetic effects of VDR variants on osteoporosis and BMD, we directly sequenced the VDR gene in 24 unrelated Korean individuals and identified eighteen sequence variants. We investigated the potential involvement of eight SNPs in osteoporosis in postmenopausal women (n = 729). Two SNPs (LD) in intron 2, -5294G>C (rs2238135) and -4817G>A (rs17882443) showed the evidence of association with enhanced BMD of the femoral neck ($p_{additive}$=0.031 for rs2238135; $p_{additive}$=0.017 and $p_{dominant}$= 0.019 for 17882443). Moreover, VDR -4817G>A was significantly associated with protective effect on all fracture risk ($p_{recessive}$=0.035, OR=0.2, 95% CI=$0.05{\sim}0.89$), and tended to be higher BMD values at various proximal femur sites. Therefore, we suggest that the -4817G>A may be useful genetic marker for vitamin D-related metabolism and may have an important role in the increased BMD of the proximal femur in postmenopausal Korean women.

A Study on the Safety of Lifting Cable for Construction of Coastal Structures (항만건설을 위한 케이슨 들고리의 안전성에 관한 연구)

  • Kwak, Kae Hwan;Jang, Ki Woong;Kim, Jong Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.1 s.34
    • /
    • pp.85-99
    • /
    • 1998
  • This paper describes an experimental study to examine collapse causes of the lifting cable due to brittle failure of an fitting anchor under the lifting works. Also, in this study an collapse mechanism that was obtained from stress analysis was compared with an actual collapse procedure. Fractographical analysis as well as chemical component test, tension test and Charpy V-Notch impact test for the fractured steel members were carried out. And then, its results were compared with that of normal steel members. Circumferential surface flaws were developed at internal facets of the fitting anchor before tensile stress occurred. Hence, a higher stress than nominal stress was occurred at flaws by stress concentration at the crack tip. Also, stress intensity factor of members increased by crack size of the potential flaws. Because the stress intensity factor at the crack tip was greater than critical values(fracture toughness), brittle fracture occurred under the lifting works. It is judged that the main collapse of the lifting cable is due to brittle fracture of the fitting anchor.

  • PDF

Effects of Chitosan on Fracture Healing in Fractured Rat Model. (골절모델 쥐에서 키토산 투여가 골절치유에 미치는 영향)

  • 서정욱;김은주;한상섭
    • Journal of Life Science
    • /
    • v.14 no.3
    • /
    • pp.385-390
    • /
    • 2004
  • Chitosan is abundant polysaccharide polymer in nature Chitosan has been the subject of much research regarding its potential as a nutritional adjunct and pharmaceutical ingredient. In the present study, we examined fracture-healing process with chitosan administration and low calcium diet in rats. Left femur was fractured and fixed with intramedullary pin. The rats were fed normal diet or low calcium diet and administered chitosan with the doses of 0, 50, 100 and 150ng/ml orally 5 times a week for 10 weeks. Soft X-ray and mechanical testing of all fractured femora was taken. Radiographical finding showed that the callus formation and process of fracture healing was present in all the fractured femora. Mechanical testing indicated that the maximum load and stiffness of femur in rat fed low calcium diet was lower than those of that in rat fed normal diet. No difference in maximum load and stiffness of fractured femora in chitosan treated rat were observed as compared to vehicle treated rat. Chitosan or/and low calcium diet did not affect the ratio of fractured/unfractured femur about maximum load and stiffness. The results suggest that chitosan dose not affect the bone mechanical strength and the process of fracture healing. Low calcium diet does decrease the bone mechanical strength.

A COMPARATIVE STUDY ON THE FRACTURE STRENGTH AND MARGINAL FITNESS OF FIBER-REINFORCED COMPOSITE BRIDGE (섬유강화형 복합레진브릿지의 파절강도 및 변연적합도에 관한 연구)

  • Choi Ho-Kuen;Shin Sang-Wan;Lim Ho-Nam;Suh Kuyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.526-546
    • /
    • 2001
  • Fiber-reinforced composite(FRC) was developed as a structural component for dental appliances such as prosthodontic framework. FRC provides the potential for fabrication of a metal-free, excellent esthetic prostheses. It has demonstrated success as a result of its simple fabrication, natural colour, and marginal integrity, and fracture resistance of veneering composite resin and the FRC material. Although it has lots of merits, clinical and objective data are insufficient. The purpose of this study was to evaluate the fracture strength and the marginal fitness of fiber reinforced composite bridge in the posterior region for clinical application. Sixteen bridges of each group. $Targis/Vectris^{(R)}$, $Sculpture-Fibrekor^{(R)}$, and In-Ceram, were fabricated. All specimens were cemented with Panavia 21 to the master dies. Strength evaluation was accomplished by a universal testing machine (Instron). The marginal fitness was measured by using the stereoscope (${\times}50$). The results were as follows. : 1. The fracture strength according to the materials was significantly decreased in order In-Ceram($238.81{\pm}82$), Targis Vectris($176.25{\pm}18.93$), Sculpture-Fibrekor($120.35{\pm}20.08$) bridges. 2. FRC resin bridges were not completely fractured, while In-Ceram bridges were completely fractured in the pontic joint. 3. The marginal accuracy was significantly decreased in order Targis/Vectris ($60.71{\mu}m$), Sculpture-Fibrekor($73.10{\mu}m$) In-ceram Bridge ($83.81{\mu}m$). 4. The fitness of occlusal sites had a lower value than the marginal sites(P<0.001), and the marginal gaps of inner site of the pontic were greater than that of outer sites of the pontic. Fiber reinforced composite bridges are new, esthetic prosthesis and can be clinically used in anterior regions and short span bridges. However, caution must be exercised when extrapolating laboratory data to the clinical situation because there are no long term clinical data regarding the overall success of the FRC.

  • PDF

The study on corrosion fatigue and cathodic protection of the steel plates used for the shipbuilding (조선용강재의 부식피로와 전기방식에 관한 연구)

  • 전대희;김원녕;이의호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.126-142
    • /
    • 1985
  • The plane bending corrosiion fatigue test for the welded metal parats was performed in the air and in the natural sea water with and without applying cathodic protection. The specimens tested were the weld of SM41 steel plates, SM58 steel plates and of SM41 to SM58, which were all prepared by submerged arc welding. The main results obtained from the experiment are summarized as follows: (1) In case with SM41 and SM58 steel plates, lower value of impact strength, higher value of hardness and more noble electrode potential were observed in the welded metal part than in the HAZ and base metal. Also the lowest hardness zone in the HAZ was observed with SM58 which was not found with SM41. In case with weld specimen of SM41 to SM58, the impact strength and the electrode potential of the welded metal part showed again the lowest and most noble value but the hardness value was located between those of SM41 and SM58 base metal. (2) In the fatigue test, the specimens tested in the air and under the cathodic protection were both cracked in a purely mechanical mode, but the specimens tested without cathodic protection were cracked by the combination of mechanical fracture and electro-chemical corrosion. (3) The corrosion fatigue limit of the welded metal parts of the specimen was increased by the cathodic protection. As the protection potential was varied down to -800 mV vs. SCE the fatigue limit was increased to the value tested in the air, and the maximum fatigue limit appeared at the -1, 000 - -1, 200 mV vs. SCE. However, as the protection potential was further decreased below -1, 200 mV vs.SCE, the fatigue limit of weld of SM58 and of SM41-SM58 joining was decreased but the limit was almost constant in the case of weld of SM41. (4) It is suggested that when designing steel ship the corrosion fatigue limit of welded metal parts should be stressed as a designing strength of the structure of steel ship in addition to the conventional basis considering simply tensile strength of steel and safety factor.

  • PDF

A Study on the Post-Weld Heat Treatment Effect to Mechanical Properties and Hydrogen Embrittlement for Heating Affected Zone of a RE 36 Steel

  • Moon, Kyung-Man;Lee, Myung-Hoon;Kim, Ki-Joon;Kim, Jin-Gyeong;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.2 no.6
    • /
    • pp.283-288
    • /
    • 2003
  • The cathodic protection method is being widely used in marine structural steel, however a high tensile steel like RE 36 steel for marine structural steel is easy to get hydrogen embrittlement due to over protection during cathodic protection as well as preferential corrosion of HAZ(Heating Affected Zone) part. In this paper, corrosion resistance and mechanical properties such as elongation and hydrogen embrittlement were investigated with not only in terms of electrochemical view but also SSRT(Slow Strain Rate Test) method with applied constant cathodic potential, analysis of SEM fractography in case of both As-welded and PWHT(Post-Weld Heat Treatment) of $550^{\circ}C$. The best effect for corrosion resistance was apparently indicated at PWHT of $550^{\circ}C$ and elongation was increased with PWHT of $550^{\circ}C$ than that of As-welded condition. On the other hand. Elongation was decreased with applied potential shifting to low potential direction which may be caused by hydrogen embrittlement, however the susceptibility of hydrogen embrittlement was decreased with PWHT of $550^{\circ}C$ than that of As-welded condition and Q.C(quasi cleavage) fracture mode was also observed significantly according to increasing of susceptibility of hydrogen embrittlement. Eventually it is suggested that an optimum cathodic protection potential range not causing hydrogen embrittlernent is from -770 mV(SCE) to -850 mV(SCE) in As-welded condition while is from -770 mV(SCE) to -875 mV(SCE) in PWHT of $550^{\circ}C$.

Visible Perforating Lateral Osteotomy: Internal Perforating Technique with Wide Periosteal Dissection

  • Rho, Bong Il;Lee, In Ho;Park, Eun Soo
    • Archives of Plastic Surgery
    • /
    • v.43 no.1
    • /
    • pp.88-92
    • /
    • 2016
  • There are two general categories of lateral osteotomy techniques-the external perforating method and the internal continuous method. Regardless of which technique is used, procedural effectiveness is hampered by limited visualization in the surgical field. Considering this point, we devised a new technique that involves using a wide subperiosteal dissection and internal perforation under direct visualization. Using an intranasal approach, whereby the visibility of the intended fracture line was maintained, enabled a greater degree of control, and in turn, results that were more precise, and thus predictable and reproducible. Traditionally, it has been taken as dogma that the periosteum must be preserved, considering the potential for dead space and bony instability; however, under sufficient visualization of the surgical field with an internal perforating method, complete osteotomy with fully preserved intranasal mucosa could be conducted exactly as intended. This intact mucosal lining compensates for the elevated periosteum. Compressive dressing and drainage through a Silastic angio-needle catheter enabled the elimination of dead space. Therefore, precise, reproducible, and predictable osteotomy minimizing the potential for associated complications such as ecchymosis, that is, bruising owing to hemorrhage, could be performed. In this article, we introduce a novel technique for lateral osteotomy with improved visualization.