• Title/Summary/Keyword: fracture parameters

Search Result 793, Processing Time 0.025 seconds

Evaluation of Shape Parameter Effect on the J-R Curve of Curved CT Specimen Using Limit Load Method (한계하중법을 이용한 Curved CT 시험편의 파괴저항곡선에 미치는 형상변수 영향 평가)

  • Shin, In Hwan;Park, Chi Yong;Seok, Chang Sung;Koo, Jae Mean
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.7
    • /
    • pp.757-764
    • /
    • 2014
  • In this study, the effect of shape parameters on the J-R curves of curved CT specimens was evaluated using the limit load method. Fracture toughness tests considering the shape factors L/W and $R_m/t$ of the specimens were also performed. Thereafter, the J-R curves of the curved CT specimens were compared using the J-integral equation proposed in the ASTM (American Society for Testing and Materials) and limit load solution. The J-R curves of the curved CT specimens were also compared with those of the CWP (curved wide plate), which is regarded to be similar to real pipe and standard specimens. Finally, the effectiveness of the J-R curve of each curved CT specimen was evaluated. The results of this study can be used for assessing the applicability of curved CT specimens in the accurate evaluation of the fracture toughness of real pipes.

The Efficacy of Transverse Fixation and Early Exercise in the Treatment of Fourth Metacarpal Bone Fractures

  • Moon, Suk-Ho;Kim, Hak-Soo;Jung, Sung-No;Kwon, Ho
    • Archives of Plastic Surgery
    • /
    • v.43 no.2
    • /
    • pp.189-196
    • /
    • 2016
  • Background Several techniques have been designed to treat fifth metacarpal fractures reported to be effective. However, these methods cannot be easily applied to the fourth metacarpal due to its central anatomical position. In this study, we sought to analyze the functional outcomes of patients who underwent transverse pinning for a fourth metacarpal bone fracture. Methods A total of 21 patients were selected and their charts were retrospectively reviewed. After fracture reduction, two transverse Kirchner wires were first inserted from the fifth metacarpal to the third metacarpal transversely at the distal part of the fractured bone, and then another two wires were inserted at the proximal part of the fractured bone. The splint was removed approximately one week postoperatively and the Kirchner wires were removed four to five weeks postoperatively. Patients started active and passive exercise one week after the operation. Pain visual analog scores, total active and passive motion, and the active and passive range of motion of the metacarpophalangeal joint and grip strength were evaluated. Results Dorsal angulation improved from a preoperative value of $44.2^{\circ}$ to a postoperative value of $5.9^{\circ}$. Six weeks after surgery, functional recovery parameters, such as range of motion and grip strength, had improved to 98% of the function of the normal side. No major complication was observed. Conclusions We suggest that the transverse pinning of fourth metacarpal bone fractures is an effective treatment option that is less invasive than other procedures, easy to perform, requires no secondary surgery, minimizes joint and soft tissue injury, and allows early mobilization.

Round robin analysis of vessel failure probabilities for PTS events in Korea

  • Jhung, Myung Jo;Oh, Chang-Sik;Choi, Youngin;Kang, Sung-Sik;Kim, Maan-Won;Kim, Tae-Hyeon;Kim, Jong-Min;Kim, Min Chul;Lee, Bong Sang;Kim, Jong-Min;Kim, Kyuwan
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1871-1880
    • /
    • 2020
  • Round robin analyses for vessel failure probabilities due to PTS events are proposed for plant-specific analyses of all types of reactors developed in Korea. Four organizations, that are responsible for regulation, operation, research and design of the nuclear power plant in Korea, participated in the round robin analysis. The vessel failure probabilities from the probabilistic fracture mechanics analyses are calculated to assure the structural integrity of the reactor pressure vessel during transients that are expected to initiate PTS events. The failure probabilities due to various parameters are compared with each other. All results are obtained based on several assumptions about material properties, flaw distribution data, and transient data such as pressure, temperature, and heat transfer coefficient. The realistic input data can be used to obtain more realistic failure probabilities. The various results presented in this study will be helpful not only for benchmark calculations, result comparisons, and verification of PFM codes developed but also as a contribution to knowledge management for the future generation.

Treatment of Displaced Intra-articular Calcaneal Fracture using Ollier Approach (전위된 관절 내 종골 골절의 Ollier 접근법을 이용한 치료)

  • Kim, Keun-Woo;Cho, Sang-Gi;Lee, Dong-Yeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.2
    • /
    • pp.174-179
    • /
    • 2008
  • Purpose: We evaluated the clinical results of the intraarticular calcaneal fractures treated using Ollier approach by inexperienced orthopaedic surgeon. Materials and Methods: Between August 2003 and May 2007, Of the total 46 cases, 12 cases (9 patients) of displaced intraarticular calcaneal fracture who underwent open reduction and internal fixation using Ollier approach were evaluated. The means of age was 50.5 years. According to the Sanders classification, there was no type I case and 8 cases of type II, 1 case of type III, and 3 cases of type IV. We evaluated the treatment result by assessing radiologic parameters ($B{\ddot{o}}hler$ angle, Gissane angle, and calcaneal height/width) and clinical outcomes (VAS and AOFAS score). Results: The means of follow-up period was 25.3 months. The means of B.hler angle was improved from $2.4^{\circ}$ to $26.1^{\circ}$. Radiologic and clinical union was achieved in all cases without additional procedures. Excellent result were noted in 2 cases, good in 5 cases, fair in 4 cases, and poor in 1 case. We experienced 2 cases of minor complications; 1 case of mild wound infection and 1 case of hypoesthesia on foot dorsum. Radiologic findings of subtalar arthritis were present in 2 cases. Conclusion: Ollier approach seems to be helpful to inexperienced orthopaedic surgeons for the treatment of intraarticular calcaneal fractures in that it enables them to achieve considerable clinical outcomes without serious complications.

  • PDF

Round Robin Analysis for Probabilistic Structural Integrity of Reactor Pressure Vessel under Pressurized Thermal Shock

  • Jhung Myung Jo;Jang Changheui;Kim Seok Hun;Choi Young Hwan;Kim Hho Jung;Jung Sunggyu;Kim Jong Min;Sohn Gap Heon;Jin Tae Eun;Choi Taek Sang;Kim Ji Ho;Kim Jong Wook;Park Keun Bae
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.634-648
    • /
    • 2005
  • Performed here is a comparative assessment study for the probabilistic fracture mechanics approach of the pressurized thermal shock of the reactor pressure vessel. A round robin consisting of one prerequisite deterministic study and five cases for probabilistic approaches is proposed, and all organizations interested are invited. The problems are solved by the participants and their results are compared to issue some recommendation of best practices and to assure an understanding of the key parameters in this type of approach, like transient description and frequency, material properties, defect type and distribution, fracture mechanics methodology etc., which will be useful in the justification through a probabilistic approach for the case of a plant over-passing the screening criteria. Six participants from 3 organizations responded to the problem and their results are compiled and analyzed in this study.

[ $C^{\ast}$ ]-integral Based Life Assessment of High Temperature Pipes ($C^{\ast}$-적분에 기초한 고온배관 수명평가)

  • Lee Hyungyil
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.25-33
    • /
    • 2000
  • In recent years, the subject of remaining life assessment has drawn considerable attention in power plants, where various structural components typically operate at high temperature and pressure. Thus a life prediction methodology accounting for high temperature creep fracture is increasingly needed for the components. Critical defects in such structures are generally found in the form of semi-elliptical surface crack, and the analysis of which is consequently an important problem in engineering fracture mechanics. On this background, we first develop an auto mesh generation program for detailed 3-D finite element analyses of axial and circumferential semi-elliptical surface cracks in a piping system. A high temperature creep fracture parameter $C^{\ast}$-integral is obtained from the finite element analyses of generated 3-D models. Post crack growth module is further appended here to calculate the amount of crack growth. Finally the remaining lives of surface cracked pipes for various analytical parameters are assessed using the developed life assessment program.

  • PDF

Dynamic Fracture Properties of Nylon Thermoplastic Material Depending on Notch Angle with Charpy Impact Machine and Finite Element Method (유한요소법과 샤피충격시험기에 의한 노치각도에 따른 나일론 열가소성 플라스틱 재료의 파괴특성)

  • Park, Myung-Kyun;Lee, Jung-Won;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • The notched Charpy impact test is one of the most prevalent techniques used to characterize the effect of high impulse loads on polymeric materials. In this study, a method of analysis in nylon plastic materials is suggested to evaluate the critical strain energy release rate for variation of notch angles from the Charpy impact energy measurement. Instrumented Charpy impact tester was used to extract ancillary information concerning fracture parameters in addition to total fracture properties and maximum critical load. The dynamic stress intensity factor of nylon plastic material was calculated for the ASTM Charpy specimen from the obtained maximum critical load. Also, the finite element model was developed to figure out the stress distributions for Charpy specimen with different notch angles subject to 3 point bending load which is equivalent to the load applied in the experiment.

  • PDF

The Retrial of Percutaneous Vertebroplasty for the Treatment of Vertebral Compression Fracture

  • Kim, Han-Woong;Kwon, Austin;Lee, Min-Cheol;Song, Jae-Wook;Kim, Sang-Kyu;Kim, In-Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.4
    • /
    • pp.278-281
    • /
    • 2010
  • Objective : For the treatment of osteoporotic vertebral compression fracture, percutaneous vertebroplasty (PVP) is currently widely used as an effective and relatively safe procedure. However, some patients do not experience pain relief after PVP. We performed several additional PVP procedures in those patients who did not have any improvement of pain after their initial PVP and we obtained good results. Our purpose is to demonstrate the effective results of an additional PVP procedure at the same previously treated level. Methods : We reviewed the medical records and the radiologic data of the PVP procedures that were performed at our hospital from November 2005 to May 2008 to determine the patients who had undergone additional PVP. We identified ten patients and we measured the clinical outcomes according to the visual analogue scale (VAS) score and the radiologic parameters, including the anterior body height and the kyphotic angulation. Results : The mean volume of polymethylmethacrylate injected into each vertebrae was 4.3 mL (range: 2-8 mL). The mean VAS score was reduced from 8 to 2.32. The anterior body height was increased from 1.7 cm to 2.32 cm. The kyphotic angulation was restored from 10.14 degrees to 2.32 degrees. There were no complications noted. Conclusion : The clinical and radiologic outcomes suggest that additional PVP is effective for relieving pain and restoring the vertebral body in patients who have unrelieved pain after their initial PVP. Our study demonstrates that additional PVP performed at the previously-treated vertebral levels could provide therapeutic benefit.

Risk Factors for Delayed Hinge Fracture after Plate-Augmented Cervical Open-Door Laminoplasty

  • Hur, Junseok W.;Park, Youn-Kwan;Kim, Bum-Joon;Moon, Hong-Joo;Kim, Joo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.368-373
    • /
    • 2016
  • Objective : Delayed hinge fracture (HF) that develops after cervical open door laminoplasty can be a source of postoperative complications such as axial pain. However, risk factors related to this complication remain unclear. We performed a retrospective clinical series to determine risk factors for delayed HF following plate-only open-door cervical laminoplasty. Methods : Patients who underwent plate-only open-door laminoplasty and had available postoperative computed tomography (CT) scans (80 patients with 270 laminae) were enrolled. Hinge status, hinge gutter location, open location, hinge width, number of screws used, operation level, and open angle were observed in the CT to determine radiographic outcome. Demographic data were collected as well. Radiographic and clinical parameters were analyzed using univariate and multivariate logistic regression analysis to determine the risk factors for HF. Results : Univariate logistic regression analysis results indicated poor initial hinge status, medially placed hinge gutter, double screw fixation on the elevated lamina, upper surgical level, and wide open angle as predictors for HF (p<0.05). Initial hinge status seemed to be the most powerful risk factor for HF (p=0.000) and thus was collinear with other variables. Therefore, multivariate logistic regression analysis was performed excluding initial hinge status, and the results indicated that medially placed hinge gutter, double screw fixation on the elevated lamina, and upper surgical level were risk factors for HF after adjustment for other confounding factors. Conclusion : To prevent HF and to draw a successful postoperative outcome after cervical laminoplasty, surgical and clinical precautions should be considered.

A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS ON STRESS AND DISPLACEMENT RELATED TO ISTHMUS WIDTH OF GOLD INLAY CAVITY (금인레이 와동의 폭경이 응력분포와 변위에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Hwang, Ho-Keel;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.384-408
    • /
    • 1994
  • The purpose of this study was to evaluate the fracture resistance of tooth restored with gold inlay. A profound understanding of the isthmus width factor, which is one of the several parameters of cavity designs, would facilitate the appropriate cavity preparation in a specific clinical situation. In this study, the cavities for gold inlay were prepared in maxillary left first premolar. A three-dimensional model was designed using I-DEAS program. The model was composed of 2515- nodes and 2172 isoparametric brick elements. In the model isthmus width was varied into 1/4, 1/3 and 1/2 of intercuspal width respectively, and numeric values of the material properties of enamel, dentin and gold was set. Three types of load : concentrated load, divided load and distributed load was 500N. The empty cavities in the model were also examined using divided load and distributed load. The three - dimensional Finite Element Method was used to analysis the displacement and stress distribution. The results were as follows : 1. All of the experimental models which were filled with gold inlay revealed similar direction of displacement to that of the natural tooth model under the same load type. But in the models with empty cavities, as the isthmus width increased, the degree of displacement increased in the case of divided load type. 2. All experimental models which were filled with gold inlay showed stress concentration at load points, but in the models with empty cavities at divided load type, as isthmus width increased, stress was concentrated at the comer of the pulpal floor. 3. In the models with empty cavities at divided load type, tooth fracture was expected regardless of isthmus width, but all experimental models which were filled with gold inlay after cavity preparation were not susceptible to fracture. 4. In all experimental models which were filled with gold inlay after cavity preparation, displacement patterns were similar under both concentrated and divided load types. In the models with empty cavities, a divided load resulted in a bucco-lingual cuspal displacemenat in both sides, but a distributed load resulted in a lingual displacement of the tooth.

  • PDF