• Title/Summary/Keyword: fourier spectrum

Search Result 480, Processing Time 0.029 seconds

Signal Processing for MoC Brake Rattle Noise of Moving Vehicles Using Prony Analysis (프로니 분석을 이용한 주행 환경에서의 브레이크 래틀 소음 발생 특성 분석)

  • Lee, Jaecheol;Kwak, Yunsang;Park, Junhong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.4
    • /
    • pp.245-250
    • /
    • 2015
  • To verify the possibility of generating rattling noise from a motor on caliper brake system, a test was conducted using a caliper excited with vibrations similar to that in a vehicle running on actual roads; this test was conducted using a quiet shaker installed in an anechoic room. After several hours of external excitation, the test assembly was loosened, and the frequency of rattling noise generation increased. A microphone was used to record the generated noise. The measured signals were analyzed by conventional spectrum analysis. Since the noise is generated as an impact response, the advantages of employing Prony analysis was discussed, and the results were compared to those obtained using conventional fast Fourier transforms. The accuracy of Prony analysis was through endurance tests on different brake systems.

Photoluminescence of Nanocrystalline CdS Thin Films Prepared by Chemical Bath Deposition

  • Park, Wug-Dong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.4
    • /
    • pp.170-173
    • /
    • 2010
  • Nanocrystalline cadmium sulfide (CdS) thin films were prepared using chemical bath deposition in a solution bath containing $CdSO_4$, $SC(NH_2)_2$, and $NH_4OH$. The CdS thin films were investigated using X-ray diffraction (XRD), photoluminescence (PL), and Fourier transform infrared spectroscopy (FTIR). The as-deposited CdS thin film prepared at $80^{\circ}C$ for 60 min had a cubic phase with homogeneous and small grains. In the PL spectrum of the 2,900 A-thick CdS thin film, the broad red band around 1.7 eV and the broad high-energy band around 2.7 eV are attributed to the S vacancy and the band-to-band transition, respectively. As the deposition time increases to over 90 min, the PL intensity from the band-to-band transition significantly increases. The temperature dependence of the PL intensity for the CdS thin films was studied from 16 to 300 K. The $E_A$ and $E_B$ activation energies are obtained by fitting the temperature dependence of the PL intensity. The $E_A$ and $E_B$ are caused by the deep trap and shallow surface traps, respectively. From the FTIR analysis of the CdS thin films, a broad absorption band of the OH stretching vibration in the range $3,000-3,600\;cm^{-1}$ and the peak of the CN stretching vibration at $2,000\;cm^{-1}$ were found.

A Frequency Domain Analysis of Corneal Deformation by Air Puff (Air puff에 의한 각막 변형의 주파수 영역 분석)

  • Hwang, Ho-Sik;Lee, Byeong Ha;Lee, Chang Su
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.240-247
    • /
    • 2014
  • Intraocular pressure is measured after a cornea air puff by observing biomechanical properties such as thickness or displacement of the cornea. In this paper, we deal with a frequency domain analysis of corneal deformation in the air puff tonometry that is used to diagnose glaucoma or lasik. We distinguish the patient from the normal by measuring the oscillation frequency in the neighborhood of the central cornea section. A binary image was obtained from the video images, and cornea vertical oscillation profile was extracted from the difference between the vertical displacement data and the curve fitting. In terms of Fourier transform, a vibration frequency of 479.2Hz for the patient was obtained as well as more higher 702.8Hz for the normal due to stiffness. Hilbert-Huang transform's empirical mode decomposition generally describes local, nonlinear, and nonstationary data. After the data were decomposed into intrinsic mode functions, a spectrum and power were analysed. Finally, we confirm that the patient has 6 times more higher power ratio for the specific intrinsic mode function between the patient and the normal.

Texture Analysis Algorithm and its Application to Leather Automatic Classification Inspection System (텍스처 분석 알고리즘과 피혁 자동 선별 시스템에의 응용)

  • 김명재;이명수;권장우;김광섭;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.363-366
    • /
    • 2001
  • The present process of grading leather quality by the rare eyes is not reliable. Because inconsistency of grading due to eyes strain for long time can cause incorrect result of grading. Therefore it is necessary to automate the process of grading quality of leather based on objective standard for it. In this paper, leather automatic classification system consists of the process obtaining the information of leather and the process grading the quality of leather from the information. Leather is graded by its information such as texture density, types and distribution of defects. This paper proposes the algorithm which sorts out leather information like texture density and defects from the gray-level images obtained by digital camera. The density information is sorted out by the distribution value of Fourier spectrum which comes out after original image is converted to the image in frequency domain. And the defect information is obtained by the statistics of pixels which is relevant to Window using searching Window after sort out boundary lines from preprocessed images. The information for entire leather is used as standard of grading leather quality, and the proposed algorithm is practically applied to machine vision system.

  • PDF

Extraction of Respiratory Rate by using FFT for Radial Artery Pulse Waves Acquisited by Clip-type Pulsimeter with a Hall Sensor (홀센서 집게형 맥진기 요골동맥파에 FFT를 적용한 호흡수 추출 연구)

  • Cho, Hyun-Sung;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.5
    • /
    • pp.178-182
    • /
    • 2012
  • This research suggested that the extraction of respiratory rate could be made possible by using frequency analysis in the data process for clip-type pulsimeter equipped with permanent magnet and Hall sensor. The pulse analysis included of cardiac motion information depending on variation of pulse waveforms is investigated by means of Fast Fourier Transformation (FFT). The peaks of FFT spectrums measured at 15, 20, 30, 40, and 50 tempos are coincided to each respiratory rate having 0.125 Hz, 0.16 Hz, 0.25 Hz, 0.33 Hz, and 0.41 Hz, respectively. The FFT spectrum using algorithm for the extraction of respiratory rate showed the best pulse waves measured during 300 s. Based upon these results, the clip-type pulsimeter could extract the effective respiratory rate reflecting physical effects.

Evaluation of Fourier Transform Near-infrared Spectrometer for Determination of Oxalate in Standard Urinary Solution (표준 요 시료 중 Oxalate의 측정을 위한 FT-NIR 분광기의 유용성 검정)

  • Kim, Yeong-Eun;Hong, Su-Hyung;Kim, Jung-Wan;Lee, Jong-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.39 no.2
    • /
    • pp.165-170
    • /
    • 2006
  • Objectives : The determination of oxalate in urine is required for the diagnosis and treatment of primary hyperoxaluria, idiopathic stone disease and various intestinal diseases. We examined the possibility of using Fourier transform near-infrared (FT-NIR) spectroscopy analysis to quantitate urinary oxalate. The practical advantages of this method include ease of the sample preparation and operation technique, the absence of sample pre-treatments, rapid determination and noninvasiveness. Methods : The range of oxalate concentration in standard urine solutions was $0-221mg/{\ell}$. These 80 different samples were scanned in the region of 780-1,300 nm with a 0.5 nm data interval by a Spectrum One NTS FT-NIR spectrometer. PCR, PLSR and MLR regression models were used to calculate and evaluate the calibration equation. Results : The PCR and PLSR calibration models were obtained from the spectral data and they are exactly same. The standard error of estimation (SEE) and the % variance were $10.34mg/{\ell}$ and 97.86%, respectively. After full cross validation of this model, the standard error of estimation was $5,287mg/{\ell}$, which was much smaller than that of the pre-validation. Furthermore, the MCC (multiple correlation coefficient) was 0.998, which was compatible with the 0.923 or 0.999 obtained from the previous enzymatic methods. Conclusions : These results showed that FT-NIR spectroscopy can be used for rapid determination of the concentration of oxalate in human urine samples.

Optical properties and color analysis of various pearl shells (다양한 진주조개 패각의 색상 및 광학적 특성 분석)

  • Lee, Myung-Jin;Chae, Weon-Sik;Seo, Jin-Gyo;Park, Jong-Wan
    • The Korean Journal of Malacology
    • /
    • v.25 no.3
    • /
    • pp.203-210
    • /
    • 2009
  • Optical properties and color analysis of nacreous layers were performed using various pearl shells. The cross section and microstructure of the surface in each nacreous layers were observed through a SEM (Scanning Electron Microscope), and the diffraction pattern on SEM images was analyzed using FFT (Fast Fourier Transform). Through these analysises, it was verified that the color and optical characteristics are closely related to the structure of nacreous layers. Incident angle-dependent reflection spectrum was used to examine the phenomena of color differenceas the direction of observation. Quantified values on the color change were obtained by CIE $L^*a^*b^*$ color scale. Using this research, database for the characteristics of natural pearl shells can be established, and the precise analytic method for observation of pearl shells was suggested.

  • PDF

Robust Audio Watermarking Algorithm with Less Deteriorated Sound (음질 열화를 줄이고 공격에 강인한 오디오 워터마킹 알고리듬)

  • Kang, Myeong-Su;Cho, Sang-Jin;Chong, Ui-Pil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.653-660
    • /
    • 2009
  • This paper proposes a robust audio watermarking algorithm for copyright protection and improvement of sound quality after embedding a watermark into an original sound. The proposed method computes the FFT (fast Fourier transform) of the original sound signal and divides the spectrum into a subbands. Then, it is necessary to calculate the energy of each subband and sort n subbands in descending order corresponding to its power. After calculating the energy we choose k subbands in sorted order and find p peaks in each selected subbands, and then embed a length m watermark around the p peaks. When the listeners hear the watermarked sound, they do not recognize any distortions. Furthermore, the proposed method is robust as much as Cox's method to MP3 compression, cropping, FFT echo attacks. In addition to this, the experimental results show that the proposed method is generally 10 dB higher than Cox's method in SNR (signal-to-noise ratio) aspect.

Long Term Average Spectrum Characteristics of Head and Chest Register Sounds of Western Operatic Singers : Extended Study (성악다들의 목소리에 대한 Long Term Average Spectrum 분석 -$2^{nd}$ Singer's Formant의 존재 가능성에 대하여-)

  • Ban, Jae-Ho;Kwon, Young-Kyung;Jin, Sung-Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.1
    • /
    • pp.31-36
    • /
    • 2004
  • Background and Objectives : It has been shown that the epilaryngeal tube in the human airway is responsible for vocal ring, or the singer's formant. In previous study, authors showed that in trained tenors, besides the conventional singer's formant in the region of ,5500Hz, another energy peak was observed in the region of 8,000Hz. This peak was interpreted as the second resonance of the epilarynx tube. Singers in other voice categories who produce vocal ring are assumed to have the same peak, but no measurements have as yet been made. Materials and Methods : Fifteen tenors, fourteen baritones, seven sopranos and five mezzo sopranos attending the music college, department of vocal music who could reliably produce the head and chest registers were chosen for this study. Each subject was asked to produce an/ah/sound for at least three seconds for the head register sound(tenors ; G4, barions ; E4 sopranos ; F5 and mezzosopranos ; C5) and for the chest register sound (tenors ; C3, baritones ; D3, sopranos ; D4 and Mezzosoprano ; A3). The sound data was analyzed using the Fast Fourier Transform (FFT)-based power spectrum, Long term average(LTA) power spectrum using the FFT algorithm of the Computerized Speech Lab (CSL, Kay elemetrics, Model 4300B, USA). Statistical analysis was performed using the Mann-Whitney test of the Statistical Package for Social sciences(SPSS). Results : For head register sounds, a significant increase was seen in the 2,200-3,400Hz region(p<0.05) and the Similar to the head register sounds, there was a significant increase in energy in the four trained singer group compared with the untrained group in the 2,200-3,100Hz region(p<0.05), the 7,800-8,400Hz region(p<0.05) for the chest register sounds. Conclusions : When good vocal production was made for the head and chest registers, an energy peak was observed near 2,500Hz, a frequency already known as the "singer's formant', in all subjects in the study group. Another region of increased energy was observed around 8,000Hz that had not been noticed previously. The authors believe this region to be the second singer's formant.

  • PDF

Improvement of Cloud-data Filtering Method Using Spectrum of AERI (AERI 스펙트럼 분석을 통한 구름에 영향을 받은 스펙트럼 자료 제거 방법 개선)

  • Cho, Joon-Sik;Goo, Tae-Young;Shin, Jinho
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.2
    • /
    • pp.137-148
    • /
    • 2015
  • The National Institute of Meteorological Research (NIMR) has operated the Fourier Transform InfraRed (FTIR) spectrometer which is the Atmospheric Emitted Radiance Interferometer (AERI) in Anmyeon island, Korea since June 2010. The ground-based AERI with similar hyper-spectral infrared sensor to satellite could be an alternative way to validate satellite-based remote sensing. In this regard, the NIMR has focused on the improvement of retrieval quality from the AERI, particularly cloud-data filtering method. The AERI spectrum which is measured on a typical clear day is selected reference spectrum and we used region of atmospheric window. We performed test of threshold in order to select valid threshold. We retrieved methane using new method which is used reference spectrum, and the other method which is used KLAPS cloud cover information, each retrieved methane was compared with that of ground-based in-situ measurements. The quality of AERI methane retrievals of new method was significantly more improved than method of used KLAPS. In addition, the comparison of vertical total column of methane from AERI and GOSAT shows good result.