• Title/Summary/Keyword: fossil power plant

Search Result 216, Processing Time 0.026 seconds

Creep Damage Evaluation of High-Temperature Pipeline Material for Fossil Power Plant by Ultrasonic Test Method (초음파에 의한 발전소 고온배관재료의 크리프손상 평가)

  • Lee, Sang-Guk;Chung, Min-Hwa
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.99-107
    • /
    • 1999
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operationg conditions which are high temperature and high pressure for an extended period time. Such material degradation leads to various component failures causing serious accidents at the plants. Conventional measurement techniques such as replica method, electric resistance method, and hardness test method have such disadvantages as complex preparation and measurement procedures, too many control parameters, and therefore, low practicality and they were applied only to component surfaces with good accessibility. In this paper, artificial creep degradation test and ultrasonic measurement for their creep degraded specimens have been carried out for the purpose of evaluation for creep damage which can occur in high-temperature pipeline of fossil power plant. Absolute measuring method of quantitative ultrasonic measurement for material degradation was established, and long term creep degradationtests using life prediction formula were carried out. As a result of ultrasonic tests for crept specimens, we confirmed that the sound velocity decreased and the attenuation coefficient linearly increased in proportion to the increase of creep fractiin(${\phi}$c).

  • PDF

Nondestructive Testing and Applications for Integrity Assessment of Power Plant Facilities by Acoustic Emission Technology - Part 1 : The Theory of Acoustic Emission Technology(I) - (발전설비 건전성평가를 위한 음향방출 비파괴검사 적용기술 - 제1편 : 음향방출 비파괴검사기술 이론(I) -)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.5-13
    • /
    • 2005
  • Acoustic emission(AE) is defined as the transient elastic waves thar are generated by the rapid release of energy. The advantage of AE is that very early crack growth can be detected well before a highly stressed component may fail. At present, an exact diagnosis is the most reliable means for determining the soundness of structures during power plant operations. AE monitoring has been applied successfully in power plants to determine mechanical problems, pressure vessel integrity and external valves leaks, vacuum leaks, the onset of cavitation in pumps and valves, the presence of flow(or no flow) in piping and heat exchange equipment, etc. Acoustic emission(AE) technology has recently strengthened its application base, and practitioners' understanding of the technique's fundamentals. This paper introduces the methods of a survey and assessment on AE monitoring applications in nuclear, fossil and hydraulic power plant. The main objective of this paper was to obtain information on various applications of AE technology in power plant.

  • PDF

Comparison of properties at Fossil Power Plant by On-Line Real Time Performance Monitoring System (On-Line 실시간 성능감시 시스템을 이용한 화력발전소 운전 Parameter 값 비교분석)

  • Jung, Hoon;Park, Doo-Yong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3501-3505
    • /
    • 2007
  • As the power plant industry has been changed into competition structure, power generation companies do more with less by increasing capacity and lowering operation costs. In order to achieve this goals, an on-line real-time performance monitoring system has been needed to introduced to fossil power plant. The system represents a suite of related software modules which consist of on-line data, and on-line performance modules. This system can help the plant staff get the most out of their facilities by continuously monitoring deviations in equipment performance and the impact on those deviations on plant power, heat rate and operating cost. This paper shows the comparison of design value with acceptance test and current(measured) value.

  • PDF

Modeling and Simulation for Dynamic Behaviors of SOVR for Electric Power Plant (P&S를 활용한 발전용 SOVR의 모델링과 동특성 해석)

  • 노태정
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.203-203
    • /
    • 2000
  • The P&S(Power Plant Simulation System) is a powerful simulation software system for the dynamic behavior of power plants. The P&S module libraries provide plant models with higher flexibility of dynamic simulations for process and control designs. The P&S software was effectively available for PCS based on Linux and modem workstations based on Unix. The P&S was applied for simulating the dynamic behaviors of the SOVR(Supercritical Once-Through Variable Pressure Reheater) according to the operations such as stan-up, shutdown, load following, load change and trip in order to obtain an optimal operation procedure for Unit 5/6 of Taeahn fossil power plant consisted of SOVRs and steam turbines.

  • PDF

Nondestructive Testing and Applications for Electric Power Plant Equipments by Acoustic Emissin Technology (음향방출기술에 의한 발전설비 비파괴검사 및 응용)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.396-409
    • /
    • 2004
  • Diagnosis f structural integrity is the basis for correct treatment of and countermeasures against progressive structural abnormalities. An exact diagnosis is at present the most reliable means for determining the soundness of structures during power plant operations. Acoustic emission(AE) technology has recently strengthened its application base, and practitioners' understanding of the technique's fundamentals. This paper presents the results of a survey and assessment on AE monitoring applications in nuclear, fossil and hydraulic power plant. The main objective of this paper was to obtain information on various applications of AE technology in electric power plant.

Main Steam Temperature Controller Design of a Fossil Power Plant by Generic Model Control (Generic Model Control에 의한 화력발전소의 주증기 온도제어기 설계)

  • Cho, Y.C.;Nam, H.K.;Lee, K.S.;Yoon, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.673-675
    • /
    • 1995
  • A nonlinear process-model based control for main steam temperature control of a 100MW oil-fired drum-type fossil power plant is delveloped and its performances are compared to those of the conventional PID control. The process model for simulation is derived based "first priciple approach" and is validated in steady and transient conditions. The model is in good agreements with the field test data. Performances of the nonlinear PMBC for main steam temperature control are far superior to those of PID in all aspects for the disturbances of ramp increase in load and step change in fuel Btu value.

  • PDF

The Virtual Reality in Fossil Power Plant Operator Training Simulator

  • Ma, Sam-Sun;Park, Jin-Ho;Oh, Seog-Chan
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.197-200
    • /
    • 1999
  • In these days many large scale plants are attempting to use the Virtual Reality technology in the process analysis. Their goal is to reduce the development time by more effective information management as Simultaneous Engineering point of view, and by connecting the CAD datum and all kinds of products information. Generally, it is taken for granted that when a plant is equipped with a Virtual Reality technology, they are able to review the design and analyze the engineering performance of the product before actually building it, so that their goal to reduce costs and enhance the initial quality can be achieved. [1][2] In this paper we will look into the application the virtual reality technology Hadong fossil power plant. And we will also define the concepts of virtual plant by summarizing requirements and thoughts from the people who are in working in the actual site.

  • PDF

A Study on the Alarm Processing System for Fossil Power Plant (화력발전소 경보처리 시스템에 관한 연구)

  • ;;;Zeungnam Bien
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.8
    • /
    • pp.1045-1056
    • /
    • 1995
  • The purpose of multiple alarm processing is to give the operator the correct information and perception of the malfunction present in the plant. In this thesis, an APS(Alarm Processing System) is studied for fossil power plants. This APS is based on a cause-consequence trees in the knowledge representation aspect for alarm and plant and adapts alarm filtering methods using fired time information in the decision aspect. Through the cause-consequence trees and filtering methods, the Alarm Processing System finds the cause alarm among the fired multiple alarms and calculates the cause degree which represents the possibility of a fault occurring in the instruments of the plant with the information of fired alarm. The knowledge base is built via interviews and questionaries with the expert operators on the Seoul power plant unit 4. Finally, the validity of the studied APS is shown via simulations.

  • PDF

Development and Application of Life-Assessment Guidelines for Fossil-Fuel Power Plant Facilities in Korea (한국 화력 발전설비의 수명평가기준 개발 및 활용)

  • Choi, Woo-Sung;Song, Gee-Wook;Kim, Bum-Shin;Hyun, Jung-Seob;Heo, Jae-Sil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1265-1272
    • /
    • 2010
  • In view of the frequent start-ups and load changes in the recent past, there is a need for fossil-fuel power plants to be more efficient and reliable for long-term operation. Under high-temperature and high-pressure conditions, severe creep and fatigue damages can occur in major plant facilities, particularly, turbines and boilers. For highly stable operation and better maintenance, various techniques that facilitate a systematic assessment of the service life of critical facilities have been developed. However, to date, in Korea, to evaluate the remaining life of major facilities of fossil power plant, qualitative or semiquantitative analyses are carried out without following any standard guidelines or procedure. In this study, a standard code for assessing the remaining life of major plant facilities is proposed. This code takes into account creep and fatigue damage, which are generally accepted as dominant causes of damage to facilities. KEPIC (Korea Electric Power Industry code) is scheduled to include this guideline in 2010.

Calculation of CO2 Emission for Fossil-Fired Thermal Power Plant considering Coal-Oil Mix Rate (혼소율을 고려한 화력 발전소의 CO2 대기배출량 계산)

  • Lee, Sang-Joong;Kim, Soon-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.67-72
    • /
    • 2010
  • G8 summit meeting held in July 2008 decided to set up a long-term goal, by 2050, reducing the world greenhouse emissions by half of those emitted in 1990. In November 2009, the Government announced to reduce the national $CO_2$ emission by 30[%] of BAU by 2020. Electric power industries in Korea produce most of their electricity by burning fossil fuels, and emit approximately 28[%] of national $CO_2$ emissions. Monitoring the $CO_2$ emissions. Monitoring the $CO_2$ emission of electric power plants is very important. This paper presents a method to calculate the hourly $CO_2$ emission for a thermal power plant burning mixture of coal and oil using the performance test data and coal-oil mix rate. An example of $CO_2$ emission calculation is also demonstrated.