• 제목/요약/키워드: forward surface

Search Result 444, Processing Time 0.041 seconds

Inverse Offset Method for Adaptive Cutter Path Generation from Point-based Surface

  • Kayal, Prasenjit
    • International Journal of CAD/CAM
    • /
    • v.7 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • The inverse offset method (IOM) is widely used for generating cutter paths from the point-based surface where the surface is characterised by a set of surface points rather than parametric polynomial surface equations. In the IOM, cutter path planning is carried out by specifying the grid sizes, called the step-forward and step-interval distances respectively in the forward and transverse cutting directions. The step-forward distance causes the chordal deviation and the step-forward distance produces the cusp. The chordal deviation and cusp are also functions of local surface slopes and curvatures. As the slopes and curvatures vary over the surface, different step-forward and step-interval distances are appropriate in different areas for obtaining the machined surface accurately and efficiently. In this paper, the chordal deviation and cusp height are calculated in consideration with the surface slopes and curvatures, and their combined effect is used to estimate the machined surface error. An adaptive grid generation algorithm is proposed, which enables the IOM to generate cutter paths adaptively using different step-forward and step-interval distances in different regions rather than constant step-forward and step-interval distances for entire surface.

Gate Length Optimization for Minimum Forward Voltage Drop of IGBTs

  • Moon Jin-Woo;Park Dong-Wook;Choi Yearn-Ik;Chung Sang-Koo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.6
    • /
    • pp.246-250
    • /
    • 2005
  • The forward voltage drop of IGBT is studied numerically and analytically as a function of gate length. An analytical expression is presented for the first time for the surface potential variation along the channel layer under the gate of IGBT. The surface potential drop and the carrier density near the surface allow calculation of the forward voltage drop of IGBT analytically as a function of the gate length. The voltage-drop in the drift region near the gate decreases exponentially, whereas that on the surface increases linearly with increasing the gate length, the sum of which exhibits an optimum gate length, resulting in a minimum forward voltage drop. Based on the surface potential drop, a remodelling of the forward voltage drop of IGBT is also proposed.

The Effect of Seat Surface Inclination on Respiratory Function and Speech Production in sitting (앉은 자세에서 의자 표면 경사도가 호흡기능과 구어 산출에 미치는 영향)

  • Shin, Hwa-Kyung;Kim, Hye-Su;Lee, Ok-Bun
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.1
    • /
    • pp.29-34
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the difference between respiratory function and speech production, according to the seat surface inclination while in the sitting position. Methods: Respiratory function (FVC, FEV1) and speech production (inspiratory frequency, unit reading time, paragraph reading time) were measured in 3 sitting conditions: horizontal seat surface, seat surface tilted forward 15 degrees, and seat surface tilted backward 15 degrees. Results: We found that the mean values of FVC and FEV1 were statistically significant different according to three types of sitting positions (p<0.05). The following result was observed: forward tilted sitting > horizontal sitting > backward tilted sitting. There was no significant difference in speech production between the different positions. Respiratory function and speech production had a significantly negative correlation in the forward tilted condition and the backward tilted condition. Conclusion: This finding suggests that the seat surface inclination have an effect on respiratory function. Especially, forward tilted sitting may be an effective posture that may help increases the respiratory function.

Correlation between Standing Balance and Forward Head Posture in Adolescents (청소년의 전방머리자세와 선 자세 균형간의 상관관계 연구)

  • Lee, Eun-Ju
    • PNF and Movement
    • /
    • v.18 no.1
    • /
    • pp.45-53
    • /
    • 2020
  • Purpose: This study investigated the correlation between standing balance and head-forward posture in adolescents. Methods: The participants in this study were 15 female adolescents. We took photographs of the participants' craniovertebral angle with a digital camera to determine the degree of head-forward posture. Standing balance was evaluated using the 30-second Romberg test of BT4. The measurements were taken on a stable-support surface and on an unstable-support surface using a balance pad. The data measured in this study were analyzed using SPSS version 23.0, and the statistical significance level α was established as 0.05. Pearson correlation coefficient analysis was performed to identify the correlation between the degree of head-forward position of the participants and their balance ability. Results: When we measured 30 seconds of the Romberg test, we observed that, with their eyes open, the participants' head-forward posture and balance were not correlated. However, with their eyes closed, there was a strong correlation between the forward position of the head and the balance ability, which declined as the head position increased. Conclusion: Adolescents with severe head-forward posture exhibited problems with balance in posture control with closed eyes when visual information was not available. It can be inferred that an abnormality occurs in proprioceptor sensation due to their habitual head-forward posture. Education on correct posture and preventive activities should be recommended to improve the health of such adolescents and avoid possible future problems of physical deterioration.

Effects of strengthening and stretching exercises on the forward head posture

  • Lee, Song Hee;Lee, Joon Hee
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.7 no.2
    • /
    • pp.1046-1050
    • /
    • 2016
  • The purpose of this study was to investigate the effects of strengthening and stretching exercises on forward head angle and static dynamic balance ability. 21 adults with the forward head posture were participated in this study. Subjects were randomly assigned to strengthening exercise group I(n=11) and stretching exercise group II (n=10) respectively. Each group were underwent six intervention over the period of 2 weeks, each session lasting 30 minutes. During a preliminary examination, forward head angle and static dynamic balance were measured, and a post examination was conducted that involved same procedure as preliminary examination. There were significant differences in forward head angle after exercise in both groups. In the strengthening group, center of gravity total sway distances was significantly changed under all conditions. In the stretching group, center of gravity total sway distances was significantly changed when subjects had their eyes open while standing on an foam surface. There were significant changes in center of gravity sway velocities in the strengthening group under all conditions, and the same was true in the stretching group only when the subjects had their eyes open while standing on an foam surface. In the comparison between groups, eyes closed while standing on a firm surface was significantly different. There was a significant difference in dynamic balance of the stretching group when the subjects tilted their bodies forward, and there was a statistically significant difference between groups under the same condition. The results of this study suggest that forward head posture can be corrected through therapeutic exercise, and muscle strengthening exercise more effective in improving static balance of forward head posture more than stretching exercise.

The Effect of Forward Walking and Backward Walking on Quadriceps Muscles with Treadmill Inclination: Surface Electromyographic Analysis (경사진 트레드밀에서 전방 걷기와 후방걷기 동안 넙다리네갈래근 활동성 비교: 표면 근전도 분석)

  • Han, Sang-Wan
    • Physical Therapy Korea
    • /
    • v.12 no.1
    • /
    • pp.63-70
    • /
    • 2005
  • To compare the effects of forward walking and backward walking on surface electromyographic analysis of quadriceps muscles at treadmill grades of 0%, 5% and 10%, subjects were randomized to eleven athletics (5 females, 6 males), with a mean age of 17.8 years, and a SD of 4.66 years. The values of the surface electromyographic (SEMG) activity of the rectus femoris (RF), vastus lateralis (VL) and vastus medialis oblique (VMO) were measured during forward walking and backward walking on a treadmill at grades of 0, 5 and 10%. The subjects walked for approximately 10 seconds at 4.0 km/h. The data were analyzed by repeated measuring of the two-way ANOVA and analyzed by a paired t-test between forward walking and backward walking. The SEMG activity levels of the RF, VL and VMO were the highest when both the forward walking and backward walking increased incrementally for treadmill grades of 0% to 10%, but the VMO/VL ratio had no significant changes. The SEMG activity levels of the RF, VL and VMO were significantly different between directions. However, SEMG activity levels of the RF, VL, VMO and VMO/VL ratio did not show significant difference among the treadmill grades. No statistically significant interactions were detected between the direction of walking and treadmill grade. Backward walking on the treadmill at 4 km/h and grades of 0%, 5%, 10% elicited a greater SEMG activity on the quadriceps muscles than did forward walking under the same conditions. The results suggest that the quadriceps may be effectively activated by performance at treadmill grades of 10%. This investigation confirms that backward walking up an incline may place additional muscular demands on individuals.

  • PDF

The Effect of Flexibility of Bridge and Plank Exercises using Sling Suspension on an Unstable Surface on while Standing in Healthy Young Adults

  • Yoo, Kyung-Tae
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.3
    • /
    • pp.1-9
    • /
    • 2016
  • PURPOSE: The purpose of this study was to identify the effects on flexibility of bridge and plank exercises using sling suspension on an unstable surface. METHODS: The subjects of this study were 20 healthy adults in their 20s (plank=10, bridge=10). Both types of exercise were performed three times per week for a period of four weeks. Each exercise was performed in the front and side direction. Exercise intensity was altered through the use of a sling, which was placed at the knee and ankle. Flexibility at trunk forward flexion and backward extension was measured. The trunk forward flexion was measured at sitting position. The trunk backward extension was measured at prone position. The data were analyzed by Two-way ANOVA. RESULTS: There were significant differences in the pre- and post-test for both the bridge and plank exercise groups. In the bridge exercise, significant differences were shown in the trunk forward flexion and the trunk backward extension (p<.05). In the plank exercise, a significant difference was shown in the trunk backward extension (p<.05). No significant differences were noted in interaction effect or the main effects in either group. CONCLUSION: Bridge and plank exercises on an unstable surface improve flexibility. The bridge exercise improves the flexibility of the forward and backward muscles of the trunk. The plank exercise improves the flexibility of the forward muscles of the trunk. This information would be useful in the development of exercise programs including bridge and plank exercises for improving flexibility and core stability.

Electroluminescent Characteristics of Fluorescent OLED with Alternating Current Forward Bias (교류 순방향 바이어스에 따른 형광 OLED의 전계 발광 특성)

  • Seo, Jung-Hyun;Ju, Sung-Hoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.5
    • /
    • pp.398-404
    • /
    • 2017
  • In order to study the AC driving mechanism for OLED lighting, the fluorescent OLEDs were fabricated and the electroluminescent characteristics of the OLEDs by AC forward bias were analyzed. In the case of the driving method of OLED by AC forward bias under the same voltage and the same current density, degradation of luminescent characteristics for elapsed time progressed faster than in the case of the driving method by DC bias. These phenomena were caused by the peak voltage of AC forward bias which is ${\sqrt{2}}$ times higher than the DC voltage. In addition, the degradation of the OLED was accelerated because the AC forward bias had come close to the upper limit of the allowable voltage range even though the peak voltage didn't exceed the allowable range of the OLED. However, the fabricated fluorescent OLED showed little degradation of OLED characteristics due to AC forward bias from 0 V to 6.04 V. Therefore, OLED lighting by AC driving will become commercialized if sufficient luminance is realized at a voltage at which the characteristics of the OLED are not degradation by the AC driving method.

A study on the design method of tight fit Thorso patterns for adult males using fashion CAD system - Focusing on the sway back somatotype and the bend forward somatotype - (패션 CAD 시스템을 활용한 성인남성의 타이트 핏 토르소원형 설계방법 연구 - 휜체형과 숙인체형을 중심으로 -)

  • Hong, Eun-Hee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.23 no.4
    • /
    • pp.149-166
    • /
    • 2021
  • This study tried to suggest a drafting method to draft tight fit torso patterns suitable for adult males with a sway back somatotype and a bend forward somatotype by setting and distributing the ease through the completion of the somatic surface pattern using the 3D body surface segment method. It was intended to be presented as a drafting method. As for the research method, the suitability of the somatic surface patterns and the tight fit torso patterns were confirmed by the evaluation of virtual wear, and the patterns were modified and supplemented. The research results are as follows. In the first evaluation of the tight fit torso patterns, the average, for 55 evaluation items, was 3.92 points for the sway back somatotype and 3.89 points for the bend forward somatotype. In the second evaluation, the bend forward somatotype was 4.51 points and the sway back somatotype was 4.62 points. The chest circumference ease amount for the bend forward somatotype and the sway back somatotype are 6.5% (6.8 cm) and 7% (6.8 cm) of the chest circumference, respectively, and the distribution of the front and back ease is the same at 4:6 (2.72 cm:4.08 cm). The waist circumference ease amount is 6.5% (5.8cm) and 6.5% (5.6 cm) of the waist circumference dimensions, and the distribution of the front and backease are 5:5 (1.45 cm: 1.45 cm) and 4:6 (2.24 cm: 3.36 cm), respectively. The completed tight fit torso patterns were converted into institutional formulas and presented as a drafting method.