• Title/Summary/Keyword: forward flow

Search Result 500, Processing Time 0.028 seconds

Effect of Blood Flow on Carotid and Vertebral Artery During Forward Shift on Head: Case Study (머리의 전방 이동이 경동맥과 추골동맥 혈류량의 변화에 미치는 영향: 사례연구)

  • Ko, Do-hoon;Kim, Han-il;Kim, Myung-joon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.21 no.1
    • /
    • pp.43-47
    • /
    • 2015
  • Background: The purpose of this study was to identify the effects of the blood flow on carotid and vertebral artery during the forward shift on head. Methods: A 20-year female healthy subject participated in this study. This study was set up the forward shift on head at the 3cm and 6cm in a shoulder midline (acromion). Measurement method were using duplex ultrasound with colour doppler imaging for the blood flow on carotid and vertebral artery. Results: Carotid artery was increased the blood flow and vertebral artery was decreased the blood flow during forward shift on head. Conclusions: These findings suggest that carotid and vertebral artery changes to the blood flow during forward shift on head. Therefore, we should be consider that hemodynamic factor when apply to the therapeutic exercise for patients of forward head posture.

  • PDF

Staging Flow Analysis with forward Ejector (전방 분출이 있는 단분리 유동해석)

  • Kwon K. B.;Yoon Y. H.;Hong S. K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.145-150
    • /
    • 2004
  • In this study the numerical analysis on staging flow with forward ejector is conducted. The forward ejector plays a vital role in staging, which jets out from aftbody. This staging environment needs careful flow analysis for securing staging safety Present study investigates the steady inviscid staging flow phenomena with variation of separation distance. The performance index is forebody base pressure coefficients. The three dominant flow phenomena are observed according to separation distance which could be told as impinging stage, cavity vortex dominancy stage, and pure base flow characteristics stage. Impinging stage shows high thrust for forebody as one might think. However, important point is that cavity vortex dominancy stage can be more favorable for separation than impinging stage as one simply think in certain separation distance.

  • PDF

Analysis of Flow Characteristics of Triple Filter System by the Influence of Filter Density (필터 조밀도의 영향에 의한 3단 필터 시스템의 유동특성 해석)

  • In-Soo Son
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1163-1169
    • /
    • 2023
  • In this study, the flow characteristics of the filter system were analyzed due to the effect of the density of the filter in the triple filter system. Flow analysis was performed as a flow passing through a porous medium. The flow characteristics of each filter system were analyzed by arranging filters with different densities in the forward flow flow and the reverse flow. The arrangement order of the triple filters was excellent in the case of forward fluid flow and in the case of higher density from the inside to the outside filter. In the reverse flow filter system, the performance of the system was the best in the case of reverse order filter arrangement. As a result of the analysis, Case II, which showed a pressure drop rate of 5.65% for forward flow, was the best in the reverse direction with a pressure drop rate of 14.25%. Considering reverse and forward flows, it was found that the optimal filter arrangement was most effective when the intermediate filter was the densest, and the inner or outer filter was less dense.

Performance and Flow Characteristics of a Forward Swept Propeller Fan (전향 스윕 프로펠러 홴의 성능 및 유동특성)

  • Kim, Jin-Kwon;Kang, Shin-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.75-84
    • /
    • 2000
  • Performance and flow characteristics of a small forward swept propeller fan for home refrigerators are studied experimentally. An unusual discontinuity is observed in the performance curve of the fan. Mean flow fields measured with as-hole Pitot probe reveal that the flow is axial at the high flow rate and radial at the low flow rate. The flow structure changes abruptly across the discontinuity. Unsteady flow measurements with a set of hot-wire probes indicate that near the discontinuity a single-cell stall rotates at 40% speed of the fan speed, while away from the discontinuity the flow shows periodic variation corresponding to the blade passage frequency. Phase-lock averaged flow fields measured with a triple-sensor hot-wire probe show that there appears radially inward flow over the pressure side of the blade and the outward passage flow over the tip.

VISCOUS FLOW CALCULATIONS OF HELICOPTER MAIN ROTOR SYSTEM IN FORWARD FLIGHT (전진 비행하는 헬리콥터 주로터 시스템의 점성 유동 해석)

  • Jung, M.S.;Kwon, O.J.;Kang, H.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.31-38
    • /
    • 2009
  • In the present study, viscous flow calculations of helicopter main rotor system in forward flight were made by using an unstructured hybrid mesh solver. Each rotating blade relative to the cartesian frame was simulated independently by adopting unstructured overset mesh technique. For the validation of the present method, calculations for the Caradonna-Tung non-lifting forward flight and the AH-1G main rotor system in forward flight were made. Additional computation was made for the UH-60A rotor in forward flight. Reasonable agreements were obtained between the present results and the experiment.

  • PDF

Forward-Backward Extrusion Process Development of Piston-Pin by Flow Control (유동제어에 의한 피스톤 핀의 전${\cdot}$후방압출 공정 개발)

  • Park, Jong-Nam;Park, Tae-Joon;Kim, Byung-Min
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.11a
    • /
    • pp.1-12
    • /
    • 2001
  • In cold forging of piston-pin for automobile parts, the flow defect appears by the dead metal zone. This appearance evidently happens in products with a thin piercing thickness for the dimension accuracy and the decrease of material loss. The best method that can prevent flow defect is removing dead metal zone. The purpose of this study is to investigate the material flow behavior of forward-backward extruded piston-pin through the relative velocity ratio and the stroke control of upper moving punch & container using the flow control forming technique. The finite element simulations are applied to analyse the flow defect, then the results are compared with the plasticine model material experiments. Finally, the model experiment results are in good agreement with the FE simulation ones.

  • PDF

Experimental Investigation on the Flow Control in Forward-Backward Extrusion of Piston-Pin for Automobile (자동차용 피스톤 핀의 전.후방압출에서 유동제어에 관한 실험적 연구)

  • Park, Jong-Nam;Park, Tae-Joon;Kim, Dong-Hwan;Kim, Byung-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1366-1375
    • /
    • 2002
  • In cold forging of piston-pin for automobile parts, the flow defect appears by the dead metal zone. This appearance evidently happens in products with a thin piercing thickness for the dimension accuracy and the decrease of material loss. The best method that can prevent flow defect is removing dead metal zone. The purpose of this study is to investigate the material flow behavior of forward-backward extruded piston-pin through the relative velocity ratio and the stroke control of upper moving punch & container using the flow control forming technique. The finite element simulations are applied to analyse the flow defect, then the results are compared with the plasticine model material experiments. The model experiment results are in good agreement with the FE simulation ones.

Experimental Study on the Mean Flow Characteristics of Forward-Curved Centrifugal Fans

  • Kwon, Eui-Yong;Cho, Nam-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1728-1738
    • /
    • 2001
  • Measurements have been made in an automotive HVAC b1ower for two different centrifugal fans. This work is directed at improving the performance of a conventional forward-curved centrifugal fan for a given small blower casing. Mean velocities and pressure have been measured using a miniature five-hole probe and a pressure scanning unit connected to an online data acquisition system. First, we obtained the fan performance versus flow rates showing a significant attenuation of unstable nature achieved with the new fan rotor in the surging operation range. Second, aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage for different fan operating conditions. The measurements stowed that performance coefficients are strongly influenced by flow characteristics at the throat region. The main flow features ware common in both fans, but improved performance is achieved with tole new fan rotor, particularly in lower flow rate legions. Based on the measured results, design improvements were carried out in an acceptable operation range, which gave considerable insight into what features of flow behavior ware most important.

  • PDF

Forward Osmosis Based Seawater Desalination using Liquid Fertilizer as Draw Solution (액상 비료를 유도 용액으로 사용하는 정삼투 기반의 해수 담수화)

  • Park, Seong-Jik;An, Hee-Kyung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.2
    • /
    • pp.21-27
    • /
    • 2013
  • The present study explored the way to desalinate seawater for agricultural irrigation using forward osmosis (FO) process using liquid fertilizer as draw solution. FO experiments were performed in a cross flow mode using flat sheet FO membrane. The effect of membrane orientation, flow rate, and draw solution concentration on the performance of forward osmosis was investigated by measuring water flux of forward osmosis membrane. The water flux when the draw solution was placed against the membrane active layer was lower than the water flux when the feed solution was placed against the membrane active layer. This results indicated that the decrease of effective osmotic pressure by dilutive internal concentration polarization was less than that by concentrative internal concentration polarization. Increasing flow rate from 66.7 to 133.1 $cm^3$/min resulted in increase of the water flux when the membrane active layer orient to draw solution and feed solution, respectively. The reduction of resistance to water flow increased water flux at higher flow rate. The water flux of FO membrane increased with increasing draw solution concentration from 10000 to 30000 mg/L. The water flux for $KH_2PO_4$ draw solution was similar to that for commercial fertilizer. Optimization of FO process would contribute to economically desalinate brackish water for agricultural use.

Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta (위상대조도 MRI에서 숙임각에 따른 상행대동맥의 혈류 측정)

  • Kim, Moon Sun;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.142-148
    • /
    • 2016
  • To evaluate the effect of flip angle on flow rate measurements obtained with phase contrast MRI according to the flip angle degree in ascending aorta and velocity encoding (VENC) was (150 m/s). 1.5T MRI in patients 17 (female: 8, male: 9, mean age $57.9{\pm}15.4$) as a target by applying a non-breath holding techniques to flip angle VENC (150 cm/s) in each of the ascending aorta was measured by changing $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$. Blood was obtained a peak velocity, average velocity, net forward volume, net forward volume/body surface area. Ascending aorta from average velocity (AV) measured the average value of the flip angle $20^{\circ}$ (9.87 cm/s), $30^{\circ}$ (9.6 cm/s) and $40^{\circ}$ (10.05 cm/s). Blood flow VENC in was blood flow change in flip angle change was high most blood flow measurement when the flip angle $30^{\circ}$ in VENC, crouching each blood flow is also proportional to the increases in the $20^{\circ}$ to $40^{\circ}$ and was increased, the deviation of the peak velocity and the average velocity is the smallest deviation from the flip angle $30^{\circ}$. Flip angle $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$ in peak velocity, average velocity, net forward volume, net forward volume/body surface area was no statistically significant difference (p > .05). Blood flow velocity and blood flow is measured by applying to adjust the flip angle accurately calculate the blood flow is important information for diagnosis and treatment of cardiovascular diseases, and can help in the examination on the blood flow measurement.