• Title/Summary/Keyword: form-accuracy

Search Result 1,355, Processing Time 0.025 seconds

Hyperparameter Tuning Based Machine Learning classifier for Breast Cancer Prediction

  • Md. Mijanur Rahman;Asikur Rahman Raju;Sumiea Akter Pinky;Swarnali Akter
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.2
    • /
    • pp.196-202
    • /
    • 2024
  • Currently, the second most devastating form of cancer in people, particularly in women, is Breast Cancer (BC). In the healthcare industry, Machine Learning (ML) is commonly employed in fatal disease prediction. Due to breast cancer's favorable prognosis at an early stage, a model is created to utilize the Dataset on Wisconsin Diagnostic Breast Cancer (WDBC). Conversely, this model's overarching axiom is to compare the effectiveness of five well-known ML classifiers, including Logistic Regression (LR), Decision Tree (DT), Random Forest (RF), K-Nearest Neighbor (KNN), and Naive Bayes (NB) with the conventional method. To counterbalance the effect with conventional methods, the overarching tactic we utilized was hyperparameter tuning utilizing the grid search method, which improved accuracy, secondary precision, third recall, and finally the F1 score. In this study hyperparameter tuning model, the rate of accuracy increased from 94.15% to 98.83% whereas the accuracy of the conventional method increased from 93.56% to 97.08%. According to this investigation, KNN outperformed all other classifiers in terms of accuracy, achieving a score of 98.83%. In conclusion, our study shows that KNN works well with the hyper-tuning method. These analyses show that this study prediction approach is useful in prognosticating women with breast cancer with a viable performance and more accurate findings when compared to the conventional approach.

Modeling of Various Tool Influence Functions in Computer Controlled Optical Surfacing (컴퓨터 제어를 통한 광학 가공에서의 다양한 툴 영향 함수의 모델링)

  • Kim, Gi-Chul;Ghim, Young-Sik;Rhee, Hyug-Gyo;Kim, Hak-Sung;Yang, Ho-Soon;Lee, Yun-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.3
    • /
    • pp.167-172
    • /
    • 2016
  • The computer controlled optical surfacing (CCOS) technique provides superior fabrication performance for optical mirrors when compared to the conventional method, which relies heavily on the skill of the optician. The CCOS technique provides improvements in terms of mass production, low cost, and short polishing time, and are achieved by estimating and controlling the moving speed of the tool and toolpath through a numerical analysis of the tool influence function (TIF). Hence, the exact estimation of various TIFs is critical for high convergence rates and high form accuracy in the CCOS process. In this paper, we suggest a new model for TIFs, which can be applied for various tool shapes, different velocity distributions, and non-uniform tool pressure distributions. Our proposed TIFs were also verified by comparisons with experimental results. We anticipate that these new TIFs will have a major role in improving the form accuracy and shortening the polishing time by increasing the accuracy of the material removal rate.

A Study on Fluid Intake and Output Measurements (수분 섭취 및 배설량의 측정방법에 관한 연구)

  • Choi, Smi;Yang, Young-Hee;Jung, Yun
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.1
    • /
    • pp.88-98
    • /
    • 1995
  • The Fluid and electrolytes balance in the body is of critical importance in maintaining good health. When the fluid and electrolyte imbalance is present, patients are in great danger. They must be assessed immediately by a nurse so that appropriate treatment can be started as soon as possible. Patients' fluid intake and output records contain highly important information for the diagnosis and treatment of fluid imbalance, but, these records are often inaccurate and the method of recording the fluid intake is not universal for every hospital. Be-cause they are few quantitative measurements of a patient's hydration, the need to improve the accuracy of fluid intake records is very important. However, very few studies have been done to investigate the accuracy of measurements of patients' fluid intake and output. The purpose of this study was to investigate the methods used for calculation of fluid intake which is most similar to fluid output in normal adults and hospitalized patients. This study focused on three different calculation methods for fluid intake and compared these to fluid output and developed suggestions as to the ideal way to record fluid in-take. Data for 43 hospitalized patients and 37 normal adults were analyzed. The findings of this study are as follows ; 1) In normal adults, the daily intake of water which enteres by the oral route was 2415m1 (the first method of calculation). The daily intake of water in the form of pure water or some other beverage was 1365m1 (the third method of calculation) The daily intake of water including fresh fruits and vegetables, rice, porridges, and Me m which have water content more than 80% were 2186m1 (the second method of calculation). 2) The urine output of the normal adults was 1350m1. This apprroximates the amount of fluid an adult takes in the form of pure water. 3) In patient group, the total intake of water was 2550m1 (the first method of calculation). The in-take of water in the form of pure water or as some other beverage and IV fluid was 1661m1 (the third method of calculation). The daily in-take of water including foods which have high water content was 2356m1 (the second method of calculation). 4) The urine output of the patient's group was 1728m1. This approximates the amount of fluid an adult takes in the form of pure water. 5) Investigation of the method of calculation of the patient fluid intake showed that among the 31 hospitals studied, only eight use the third method of calculation which reflects the most close value to urine output. From the results obtained in this study, it was indicated that the amount of fluid taken in the form of pure water reflects the most close value to urine output. Therefore, it can be suggested that the third method of calculation which includes water in-take only in the form of pure water or beverage should be used as patients' fluid intake record.

  • PDF

Study on Ultra-precision Grinding of EL-Max Material for Hot Press Molding (핫 프레스 성형용 EL-Max 소재 초정밀 연삭 가공에 관한 연구)

  • Park, Soon Sub;Ko, Myeong Jin;Kim, Geon Hee;Won, Jong Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.12
    • /
    • pp.1267-1271
    • /
    • 2012
  • Demand for optical glass device used for lighting could increase rapidly because of LED lighting market growth. The optical glass devices that have been formed by hot press molding process the desired optical performance without being subjected to mechanical processing such as curve generation or grinding. EL-Max material has been used for many engineering applications because of their high wear resistance, high compressive strength, corrosion resistant and very good dimensional stability. EL-Max is very useful for a glass lens mold especially at high temperature and pressure. The performance and reliability of optical components are strongly influenced by the surface damage of EL-Max during grinding process. Therefore, the severe process condition optimization shall be necessary for the highly qualified EL-Max glass lens mold. To get the required qualified surface of EL-Max, the selection of type of the diamond wheel is also important. In this paper, we report best grinding conditions of ultra-precision grinding machining. The grinding machining results of the form accuracy and surface roughness have been analyzed by using Form Talysurf and NanoScan.

Optimization of Pre-form for Manufacturing of Automobile Drum Clutch Hub Products Using Taguchi Method (다구찌기법을 이용한 자동차용 드럼 클러치 허브 제조를 위한 예비성형체의 최적화)

  • Kim, Seung-Gyu;Park, Young-Chul;Park, Joon-Hong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.6
    • /
    • pp.101-108
    • /
    • 2010
  • The drum clutch investigated in this study is formed in 5 forming steps, which are 1st deep drawing, 2nd deep drawing, restriking, embossing, and $Grob^{TM}$ processes. Dimensional accuracy of the final products greatly depends upon how much more accurate pre-form is manufactured in the previous forming processes before the $Grob^{TM}$ process. The deep drawing, restriking and embossing processes in which the pre-form is formed are very important and decisive steps. Thus in some cases, excessive strain by these operations causes dimensional inaccuracy and cracks initiated from the base and wall of the product. Process variables such as the punch shapes both of 1st and 2nd deep drawing, and punch angle were selected to evaluate the deformation characteristics. The optimum parameters were determined from forming simulations using commercial FEM codes, DEFORM and Tauchi method, specifically developed for metal forming simulation. Finally, experiments for the whole drum clutch forming processes were carried out to verify the optimized forming parameters and the analytical results.

Effective technique to analyze transmission line conductors under high intensity winds

  • Aboshosha, Haitham;El Damatty, Ashraf
    • Wind and Structures
    • /
    • v.18 no.3
    • /
    • pp.235-252
    • /
    • 2014
  • An effective numerical technique to calculate the reactions of a multi-spanned transmission line conductor system, under arbitrary loads varying along the spans, is developed. Such variable loads are generated by High Intensity Wind (HIW) events in the form of tornadoes and downburst. First, a semi-closed form solution is derived to obtain the displacements and the reactions at the ends of each conductor span. The solution accounts for the nonlinearity of the system and the flexibility of the insulators. Second, a numerical scheme to solve the derived closed-form solution is proposed. Two conductor systems are analyzed under loads resulting from HIW events for validation of the proposed technique. Non-linear Finite Element Analyses (FEA) are also conducted for the same two systems. The responses resulting from the technique are shown to be in a very good agreement with those resulting from the FEA, which confirms the technique accuracy. Meanwhile, the semi-closed form technique shows superior efficiency in terms of the required computational time. The saving in computational time has a great advantage in predicting the response of the conductors under HIW events, since this requires a large number of analyses to cover different potential locations and sizes of those localized events.

Large deflection analysis of laminated composite plates using layerwise displacement model

  • Cetkovic, M.;Vuksanovic, Dj.
    • Structural Engineering and Mechanics
    • /
    • v.40 no.2
    • /
    • pp.257-277
    • /
    • 2011
  • In this paper the geometrically nonlinear continuum plate finite element model, hitherto not reported in the literature, is developed using the total Lagrange formulation. With the layerwise displacement field of Reddy, nonlinear Green-Lagrange small strain large displacements relations (in the von Karman sense) and linear elastic orthotropic material properties for each lamina, the 3D elasticity equations are reduced to 2D problem and the nonlinear equilibrium integral form is obtained. By performing the linearization on nonlinear integral form and then the discretization on linearized integral form, tangent stiffness matrix is obtained with less manipulation and in more consistent form, compared to the one obtained using laminated element approach. Symmetric tangent stiffness matrixes, together with internal force vector are then utilized in Newton Raphson's method for the numerical solution of nonlinear incremental finite element equilibrium equations. Despite of its complex layer dependent numerical nature, the present model has no shear locking problems, compared to ESL (Equivalent Single Layer) models, or aspect ratio problems, as the 3D finite element may have when analyzing thin plate behavior. The originally coded MATLAB computer program for the finite element solution is used to verify the accuracy of the numerical model, by calculating nonlinear response of plates with different mechanical properties, which are isotropic, orthotropic and anisotropic (cross ply and angle ply), different plate thickness, different boundary conditions and different load direction (unloading/loading). The obtained results are compared with available results from the literature and the linear solutions from the author's previous papers.

ON TRANSCENDENTAL MEROMORPHIC SOLUTIONS OF CERTAIN TYPES OF DIFFERENTIAL EQUATIONS

  • Banerjee, Abhijit;Biswas, Tania;Maity, Sayantan
    • Bulletin of the Korean Mathematical Society
    • /
    • v.59 no.5
    • /
    • pp.1145-1166
    • /
    • 2022
  • In this paper, for a transcendental meromorphic function f and α ∈ ℂ, we have exhaustively studied the nature and form of solutions of a new type of non-linear differential equation of the following form which has never been investigated earlier: $$f^n+{\alpha}f^{n-2}f^{\prime}+P_d(z,f)={\sum\limits_{i=1}^{k}}{p_i(z)e^{{\alpha}_i(z)},$$ where Pd(z, f) is a differential polynomial of f, pi's and αi's are non-vanishing rational functions and non-constant polynomials, respectively. When α = 0, we have pointed out a major lacuna in a recent result of Xue [17] and rectifying the result, presented the corrected form of the same equation at a large extent. In addition, our main result is also an improvement of a recent result of Chen-Lian [2] by rectifying a gap in the proof of the theorem of the same paper. The case α ≠ 0 has also been manipulated to determine the form of the solutions. We also illustrate a handful number of examples for showing the accuracy of our results.

The Evaluation of Position Accuracy to 1:1,000 and 1:5,000 scale Digital Map (1:1,000 및 1:5,000 수치지도의 위치정확도 검증)

  • Lee, Hyun-Jik;Park, Hong-Kee;Lee, Kang-Won
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.6 no.1 s.11
    • /
    • pp.117-128
    • /
    • 1998
  • National digital maps (NDM) produced by diverse production methods through various stages are ready to distribute to public. The position accuracy problems in NDM should be inspected and evaluated to guarantee the quality of NDM. The purpose of this study is 1) to find out factors of impeding accuracy by examining the position accuracy of NDM on scales of 1:1,000 and 1:5,000, 2) to form the technical basis of making accurate digital maps and 3) to increase reliability and practical use of NDM. In this study, we found out 1) obstacles of making accurate mM especially in solving horizontal and vertical location accuracy problems and 2) error sources in production methods as well as stages. These results can be contributed to increase accuracy on modifying and upgrading NDM.

  • PDF

The effectiveness of Cardiopulmonary Resuscitation training in elementary students (일부 초등학생의 심폐소생술교육의 효과)

  • Kim, Hee-Jung;Choi, Eun-Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.2
    • /
    • pp.51-66
    • /
    • 2007
  • Purpose: With a view to providing basic data to develop cardiopulmonary resuscitation education suitable for elementary students, the cardiopulmonary resuscitation education was conducted to grasp students' knowledge, skills accuracy and the attitude change before and after the education. Methods: Convenience sampling was made on fourth and fifth graders(total-35 students) of S elementary school located in K city, Chungcheongnam-do, and this was a pre-experiment research designed before and after choosing a single group. In terms of methods, specifically we, researchers ; 1) Handed out questionnaires to students directly to make them fill in firsthand and collected the questionnaires. 2) Utilized PPT materials based on 2005 AHA guideline and DVD materials of AHA, to give students theoretical education of cardiopulmonary resuscitation. We used Anne/SkillReporter$^{(R)}$ torso produced by Leardal Inc, and Little Anne to conduct practical education individually. 3) Asked students to give Anne/SkillReporter$^{(R)}$ torso cardiopulmonary resuscitation five times with the ratio of 30 : 2, and then one of researchers filled in the evaluation sheet individually. 4) Evaluated the accuracy of students' ability to perform the resuscitation based on the record of Anne/SkillReporter$^{(R)}$ integrated printer(which was the objective tool to grasp students' skills accuracy). 5) Gave out questionnaires to make students fill them in and then collected them. after completing the practical evaluation. Results: 1) In case of the attitude about cardiopulmonary resuscitation, Students' confidency rose from 19.28%(before the education) to 93.57(after the education)- which is a positive change. 2) As the result of the education, some elementary students scored 11 points (full score-16 points), up from 5 points before the education, in terms of the knowledge about cardiopulmonary resuscitation. The average point also reached 13.14 points(after the education), jump from 8.37(before the education), which was the rise of 29.8%. 3) When it comes to the practical performance, the skills accuracy was 80.93% on average, and the calculation method was as follows: total items were 16, and each item was marked form 0 to 2 points, meaning the full score was 32 points. The minimum score was 19 points and the maximum was 32($M{\pm}SD=25.90{\pm}2.88$), which was calculated based on percentage. 4) Regarding skills accuracy, respiration accuracy(%)($M{\pm}SD=30.20{\pm}27.16$) was higher than pressure accuracy(%) ($M{\pm}SD=15.34{\pm}25.27$). Conclusion: The result showed that students' attitude on cardiopulmonary resuscitation changed positively. and meaningful difference(p = .00) existed in the change of students' knowledge. In terms of skills accuracy. chest compression and airway control showed high accuracy, but the result of Anne/SkillReporter$^{(R)}$ performance showed that the accuracy of chest compression was lower than that of mouth-to-mouth resuscitation.

  • PDF