• 제목/요약/키워드: form parameter

검색결과 945건 처리시간 0.026초

Analysis of counts in the one-way layout (일원배열 가산자료에서의 처리효과 비교)

  • 이선호
    • The Korean Journal of Applied Statistics
    • /
    • 제10권1호
    • /
    • pp.105-119
    • /
    • 1997
  • Barnwal and Paul(1988) derived the likelihood ratio statistic and $C(\alpha)$ statistic for testing the equality of the means of several groups of count data in the presence of a common dispersion parameter. These tests are generalized to be applicable without the restriction of a common dispersion parameter. And the assumed model of data is also extended from negative binomial to double exponential Poisson model. Monte Carlo simulations show the superiority of $C(\alpha)$ statistic based on the double exponential Poisson family which has a very simple form and requires estimates of the parameters only under the null hypothesis.

  • PDF

Effect of Solvents on Reactive Extraction of Acrylic Acid (Acrylic Acid의 반응추출에 미치는 용매의 영향)

  • 이상훈;신정호
    • Journal of Environmental Science International
    • /
    • 제7권6호
    • /
    • pp.753-759
    • /
    • 1998
  • In physical and reactive extraction of acrylic acid using various solvents the equilibrium characteristics of extraction were investigated. The degree of extraction in reactive extraction with Tri-n-octylamine(TOA) was 1.5~3 times than that in physical extraction. Distribution ratio was constant in methyl isobutyl ketone(MIBK) and n-butylacetate(n-BAc) but was increased with increasing the concentration of acrylic acid in benzene and chloroform. It can be explained by formation of dimers. Maximum extraction leadings of acrylic acid were three in benzene and were two in MIBK, chloroform and n-BAc, and it was found that acrylic acid was extracted as the form of $A_3$R In benzene and $A_2R$ in MIBK, chloroform and n-BAc. In effect of solvent, the degree of extraction was increased as he difference of solubility parameter of solvent and solute was decreased, and as dielectric constant of solvent was increased.

  • PDF

Characteristic analysis of inductive power transfer system by parameter variation (파라미터 변화에 따른 유도급전 시스템 특성해석)

  • Lee, Byung-Song;Bae, Chang-Han;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.215-217
    • /
    • 2004
  • This paper shows the analysis of the inductive power transfer system in conjunction with series resonant converter operating variable high frequency. Of particular interest is the sensitivity of the complete system to variations in operational frequency and parameters. In inductive power transfer system, electrical power is transferred from a primary winding in the form of a coil or track, to one or more isolated pick-up coils that may relative to the primary. The ability to transmit power without contact enables high reliability and easy maintenance that allows inductive power transfer system to be implemented in hostile environments. This technology has found application in many fields such as electric vehicles, PRT(Personal Rapid Transit) etc. The coupling between the primary and secondary is then presented to include the effects of parameter and operational frequency variation.

  • PDF

Numerical Analysis of Shrinkage Cavity Formation using the Modified Fluid Critical Solid Fraction Method (유동한계 고상율법을 이용한 수축공 생성의 수치해석)

  • Lee, Jae-Kyung;Choi, Jeong-Kil;Hong, Chun-Pyo
    • Journal of Korea Foundry Society
    • /
    • 제18권6호
    • /
    • pp.555-562
    • /
    • 1998
  • Modified fluid critical solid fraction method was utilized as a prediction parameter to describe the shrinkage formation including the position, shape and amount of shrinkage cavities. A numerical scheme was implemented adapting this method for the evaluation of solidification defects in various casting processes. In the present numerical code, the form of shrinkage cavity can be simultaneously determined when an isolated loop is predicted to occur by the fluid critical solid fraction method. An auxiliary parameter, shrinkage potential, was also used in order to calculate the amount of residual liquid during solidification. Solidification analysis was carried out for the validation of the present scheme. It was shown that the calculated results were in good agreement with those of practical casting runs in all of the casting processes envolved in the present research. It may be concluded that the present program successfully predicts the detailed shrinkage formation behavior without the consideration of interdendritic fluid flow analysis.

  • PDF

Thermomechanical postbuckling of imperfect moderately thick plates on two-parameter elastic foundations

  • Shen, Hui-Shen
    • Structural Engineering and Mechanics
    • /
    • 제4권2호
    • /
    • pp.149-162
    • /
    • 1996
  • A postbuckling analysis is presented for a simply supported, moderately thick rectangular plate subjected to combined axial compression and uniform temperature loading and resting on a two-parameter elastic foundation. The two cases of thermal postbuckling of initially compressed plates and of compressive postbuckling of initially heated plates are considered. The initial geometrical imperfection of the plate is taken into account. The formulations are based on the Reissner-Mindlin plate theory considering the first order shear deformation effect, and including the plate-foundation interaction and thermal effect. The analysis uses a deflection-type perturbation technique to determine the buckling loads and postbuckling equilibrium paths. Numerical examples cover the performances of perfect and imperfect, moderately thick plates resting on Winkler or Pasternak-type elastic foundations. Typical results are presented in dimensionless graphical form.

Design of Model Following PID Controller Using Fuzzy Tuner (퍼지 동조기법을 이용한 기준모델 추종 PID제어기의 설계)

  • Hong, Hyug-Gi;Moon, Dong-Wook;Kim, Lark-Kyo;Nam, Moon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.621-623
    • /
    • 1999
  • In this paper, Model following PID control system, which is combined PID controller with Model Reference Adaptive Controller, is proposed. To decrease complex and much calculation which is produced in tuning process, the tuning method of parameter with fuzzy algorithm is introduced. Fuzzy algorithm isn't used in the form of controller generally much used, but tuner. Experimental results show that proposed controller has the PID parameter be tuned by fuzzy algorithm. Therefore, We expect model following PID to be operated in the real-time control.

  • PDF

Dynamic Model Parameter Estimation of Hydraulic Cylinder for Robot Manipulator Control (유압구동 로보트의 제어를 위한 유압 실린더 모델 파라미터 추정)

  • Choi, Myoung-Hwan
    • Journal of Industrial Technology
    • /
    • 제16권
    • /
    • pp.113-121
    • /
    • 1996
  • In the early developmental stages of robotics,hydraulics played an important role. As the power-to-weight ratio of electric motors increased, they eventually replaced hydraulic actuators in robot manipulators. Recently, however, task requirements have dictated that the manipulator payload capacity increase to accomodate greater payload, greater length, greater reaction forces, and hydraulic actusators are being studied as an effective form of robot actuation again. For efficient control of hydraulic actuators, the knowledge of its dynamic equation is essential. However, the dynamic equation of hydraulic actuators are nonlinear, and the dynamic coefficients are time varying. In this paper, an estimation algorithm of the dynamic coefficients of the hydraulic piston dynamics are formulated. Simulation results are presented to show the possibility of the parameter estimation.

  • PDF

Analytical Noise Parameter Model of Short-Channel RF MOSFETs

  • Jeon, Jong-Wook;Park, Byung-Gook;Lee, Jong-Duk;Shin, Hyung-Cheol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권2호
    • /
    • pp.88-93
    • /
    • 2007
  • In this paper, a simple and improved noise parameter model of RF MOSFETs is developed and verified. Based on the analytical model of channel thermal noise, closed form expressions for four noise parameters are developed from proposed equivalent small signal circuit. The modeling results show a excellent agreement with the measured data of $0.13{\mu}m$ CMOS devices.

LH-Moments of Some Distributions Useful in Hydrology

  • Murshed, Md. Sharwar;Park, Byung-Jun;Jeong, Bo-Yoon;Park, Jeong-Soo
    • Communications for Statistical Applications and Methods
    • /
    • 제16권4호
    • /
    • pp.647-658
    • /
    • 2009
  • It is already known from the previous study that flood seems to have heavier tail. Therefore, to make prediction of future extreme label, some agreement of tail behavior of extreme data is highly required. The LH-moments estimation method, the generalized form of L-moments is an useful method of characterizing the upper part of the distribution. LH-moments are based on linear combination of higher order statistics. In this study, we have formulated LH-moments of five distributions useful in hydrology such as, two types of three parameter kappa distributions, beta-${\kappa}$ distribution, beta-p distribution and a generalized Gumbel distribution. Using LH-moments reduces the undue influences that small sample may have on the estimation of large return period events.

The Characteristics of Ozone Generation for Dielectric Barrier Discharge with Discharge Area variation (방전면적에 따른 유전체장벽 방전에 의한 오존생성 특성)

  • Lee, Chang-Ho;Park, Soong-Gyu;Kim, Jong-Hyun;Lee, Hyun-Chul;Song, Hyun-Jig;Lee, Sang-Keun;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.379-380
    • /
    • 2008
  • Recently, ozone is utilized in various fields and its needs are expanding. In this paper, glass and ceramic plate tyre ozonizer have been fabricated to investigate discharge parameter(input power, flow rate of supplied gas, electrode form, etc.) effect to discharge. And the conditions of discharge parameter have been investigated for optimum ozone generation. Ozone concentration is continuously increased with increasing input power for same discharge space, and ozone yield is also increased until maximum point after that it is saturated. Ozone concentration is inversely proportional to flow rate of supplied gas but ozone generation and ozone vield characteristics are improved.

  • PDF