• 제목/요약/키워드: forced-ventilation

검색결과 142건 처리시간 0.04초

공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰- (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 -)

  • 최영돈;강용태;김내현;김만회;박경근;박병윤;박진철;홍희기
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

승모판질환에서 승모판치환술에 따른 폐기능의 변화 (Changes in Pulmonary Function in Mitral Valve Disease Following Mitral Valve Replacement)

  • 이응배;김덕실
    • Journal of Chest Surgery
    • /
    • 제29권9호
    • /
    • pp.951-958
    • /
    • 1996
  • 경북대학교병원 흉부외과에서 1991년 11월부터 1993년 12월 사이에 원발성 폐질환이 없이 승모판질환으로 승모판치환술을 받은 남자 2례, 여자 10례의 환자에서 술전 및 술후 평균 9개월에 폐기능검사를 실시하였다. 승모판질환의 종류는 승모판협착이 9례, 승모판폐쇄부전이 3례였다. 술전 환자들의 NYHA 기능등급은 3등급이 11례, 4등급이 1례였는데, 술후 평균 9개월이 경과한 시점에서는 10례(83%)에서 1등급으로 호전되어 있었다. 단순흉부 X·선상의 심흉비는 술전의 평균 60.2%에서 술후에는 평균 56.3%로 유의하게 감소되었다. 전체 환자에서의 폐기능검사성적은, 술전 검사에서는 폐활량과 노력성 호기중 간유량이 경도의 감소소견을 보였고, 술후 검사에서는 노력성 호기중간유량과 최대자발성 호흡량이 경도의 감소소견을 보였다. 그러나 술전후의 폐기능검사성적을 비교하였을 때에는 어느 검사항목도 유의한 차이를 보이지 않았다. 한편 술후의 NYHA 기능등급에 의해 환자들을 두 군으로 구분하였을 때, 2등 급군에서는 술후에 유의하게 변화된 폐기능검사항목이 하나도 없었는 반면에, 1등급군에서는 6가지 검사항목에서 유의한 변화가 있었다.

  • PDF

Effects of Season, Housing and Physiological Stage on Drinking and Other Related Behavior of Dairy Cows (Bos taurus)

  • Lainez, Marielena Moncada;Hsia, Liang Chou
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권10호
    • /
    • pp.1417-1429
    • /
    • 2004
  • The objective of the paper was to study the drinking and other related behavior of dairy cows (Bos taurus). There were 142 Holstein dairy cows observed and compared in this study. The experiment was designed on the basis of two different housing systems (wet pad with forced ventilation cooling house and open house); two different seasons (winter and summer); four different stages (high milk yielding cows, low milk yielding cows, dry cows, and heifers); and grouping (home and visitor animals). All cows had free access to water. Dairy cows spent 13.8 min/day drinking in wet-pad house and 11.7 min/day in open house. owever, there was no significant difference in the duration of water drinking between these two housing systems (p>0.05). The water consumption was significantly higher in wet-pad housed animals (68 L/day) than open-housed animals (31.5 L/day) (p<0.05). A significant interaction between housing and grouping (p<0.05) was found. Home and visitor animals spent more time drinking in open house, wet-pad house, respectively. A highly significant interaction was found between housing and drinking time during the day (p<0.001). Animals in open house drank more during the morning (6:00 to 10:00 h), whereas wet-pad housed animals drank in the afternoon (14:00 to 15:00 h) and evening (18:00 to 20:00 h). The average time a cow spent in drinking in summer was not ignificantly different from that of drinking in winter. However, the water intake was significantly higher in summer (61.9 L/day) than in winter (38.6 L/day) (p<0.05). Drinking activity showed a highly significant interaction between season and physiological stage (p<0.01). High milk yield cows spent more time drinking in summer than in winter, whereas cows in all other stages followed the opposite drinking pattern. Grouping exchange did not influence the drinking behavior of dairy cows in either season (p>0.05); both home and visitor animals spent almost the same time in drinking water. A strong significant interaction between season and time during the day was found(p<0.01), suggesting that animal's high drinking frequency occurred during the daytime for both seasons, with a peak midday in winter and two peaks at 10:00 h in the morning and 19:00 h in summer. Thus, drinking behavior was associated with the cooler time of day in summer and with the warmer hours of day in winter. High and low milk yielding cows and heifers spent 15.3 min/day, 14.3 min/day, and 12.8 min/day, respectively, in water drinking activity, but there was no significant difference among them (p>0.05). There was, however, a significant difference in water drinking activity found in dry cows, which spent less time in drinking at 8.2 min/day (p<0.05).

Effects of Tropical Climate on Reproduction of Cross- and Purebred Friesian Cattle in Northern Thailand

  • Pongpiachan, P.;Rodtian, P.;Ota, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권7호
    • /
    • pp.952-961
    • /
    • 2003
  • In the first part of the study, rates of estrus occurrence and success of A.I. service in the Thai-native and Friesian crossbred, and purebred Friesian cows fed in the National Dairy Training and Applied Research Institute in Chiang Mai, Thailand were traced monthly throughout a year. An electric fan and a water sprinkler cooled the stall for the purebred cows during the hot season (March-September). Both rates in pure Friesians were at their highest in the cold-dry season (October- February), but they decreased steadily during the hot-dry season (March-May) and were at their lowest in the hot-wet season (June-September). Seasonal change of a similar pattern was observed in the incidence of estrus, but not in the success rate of insemination in the crossbred cows. By the use of reproductive data, compiled in the same institute, on the 75 % cross- and purebred Friesian cows, and climatological data in Chiang Mai district, effects of ambient temperature and humidity on the reproductive traits of cows were examined by regression analysis in the second half of the study. Significant relationships in the crossbred, expressed by positive-linear and parabola regressions, were found between reproductive parameters such as days to the first estrus (DTFE), A.I. service (DTFAI), and conception, the number of A.I. services required for conception and some climatic factors. However, regarding this, no consistent or intelligible results were obtained in purebred cows, perhaps because electric fans and water sprinklers were used for this breed in the hot season. Among climatic factors examined, the minimum temperature (MINT) in early lactation affected reproductive activity most conspicuously. As the temperature during one or two months prior to the first estrus and A.I. service rose, DTFE and DTFAI steadily became longer, although, when MINT depleted below $17-18^{\circ}C$, the reproductive interval tended to be prolonged again on some occasions. The maximum temperature also affected DTFE and DTFAI, but only in limited conditions. The effect of humidity was not clear, although the inverse relationship between DTFE and minimum humidity during 2 months before the first estrus in the crossbred seemed to be significant. Failure to detect any definite effect of climate on the reproductive traits of pure Friesians seemed to indicate that forced ventilation by electric fans and water sprinklers were effective enough to protect the reproductive ability of this breed from the adverse effects of a hot climate.

열 팽창성 Microsphere를 적용한 경량 발포 재생피혁 특성 분석 (Properties of Light-weight Expanded Bonded Leather Using Thermal Expandable Microspheres)

  • 신은철;김원주;김영우
    • 접착 및 계면
    • /
    • 제21권3호
    • /
    • pp.81-85
    • /
    • 2020
  • Shaving dust는 천연 피혁 제조 공정 중 두께 조절을 위해 발생하는 피혁 폐기물인 콜라겐 섬유로 크롬을 함유하고 있어 매립 시 환경오염 문제를 야기시킨다. 현재 유럽을 중심으로 다양한 국가에서 피혁 폐기물인 Shaving dust를 활용한 다양한 연구가 진행되고 있으며, 그 중 재생피혁(Bonded leather)은 천연 피혁 대체가능한 소재로 주목받고 있다. 재생 피혁은 바인더로 라텍스를 사용하여 다른 합성 피혁에 비해 내부 조직이 치밀하여 중량감이 높고 통기성이 저하되는 단점이 있어 열팽창성 Microsphere를 도입하여 내부 조직을 완화시켜 통기성 및 경량성 등 기능성을 개선하고자 하였다. 본 연구에서는 Shaving dust를 활용한 경량 재생피혁 제조에 관한 연구로, 열팽창성 Microsphere를 적용한 후 콜라겐 섬유의 내열성을 감안하여 100~120℃에서 발포시켜 그 경향성을 분석한 결과 120℃에서 8분간 처리하였을 때 가장 우수한 발포율을 나타내었고, 재생 피혁 단면의 SEM 분석을 통해 발포에 따른 내부 조직의 변화를 관찰하였다.

참기름과 들기름의 제조조건에 따른 벤조피렌 함량 변화 (Minimizing Benzo(a)pyrene Content in the Manufacturing of Sesame Oil and Perilla Oil)

  • 김형열;송대식
    • 한국식품저장유통학회지
    • /
    • 제15권4호
    • /
    • pp.556-561
    • /
    • 2008
  • 참기름, 들기름에서 벤조피렌의 생성경로 및 감소화 방안을 확립하고자 본 연구를 시도하였다. 산지 및 종류에 따라 다소간의 차이는 있었으나 근본적으로 국내산 및 수입산 참깨, 들깨에는 각각 $0.06{\sim}0.31{\mu}g/kg$$0.12{\sim}0.47{\mu}g/kg$의 벤조피렌이 함유되어 있었다. 이 참깨, 들깨를 $220^{\circ}C$에서 20분간 볶은 후에는 각각 $1.87{\sim}2.47{\mu}g/kg$$2.12{\sim}2.43{\mu}g/kg$의 벤조피렌이가 검출되었고, 이를 압착한 후 얻어진 기름 중에서는 각각 $3.68{\mu}g/kg$$4.64{\mu}g/kg$의 벤조피렌이 검출되었다. 이는 볶음-압착공정을 밀폐형으로 수행할 경우에는 외부의 공기를 강제로 주입하여 생성된 연기를 강제 배출시키는 것이 효과적이었다. 참기름, 들기름에 함유된 벤조피렌을 제거하기 위하여 원심분리에 의한 찌꺼기 성분의 완전분리, 규조토, 활성탄소 및 규조토-활성탄소 혼합분을 이용한 여과 등 다양한 방법을 시도해 보았으나 활성탄소에 의한 여과법에서만 감소화 효과가 나타났다. 동일한 공정을 개방형으로 수행할 경우에는 각각 $0.63{\mu}g/kg$$0.56{\mu}g/kg$이 검출되는데 볶음 공정에서 발생한 연기가 기름 중에 흡입되는 것으로 확인되었다. 따라서 개방형 공정에 의할 경우 권장규격기준인 $2.0{\mu}g/kg$ 이내의 참기름, 들기름을 생산할 수 있었다.

지역별 온실내의 잉여 태양에너지 산정 (Estimation of Surplus Solar Energy in Greenhouse Based on Region)

  • 윤용철;임재운;김현태;김영주;서원명
    • 농업생명과학연구
    • /
    • 제45권4호
    • /
    • pp.135-141
    • /
    • 2011
  • 본 연구에서는 주간동안 온실 내에서 발생되는 잉여 태양에너지를 분석하고, 또한 잉여 태양에너지의 적정 축열 시스템 설계에 필요한 기초자료를 제공할 목적으로 수행하였다. 분석에 이용된 기상자료는 표준기상년 데이터로서 이용하여 국내 주요 지역을 대상으로 온실 형태별로 잉여 태양에너지를 분석하였을 뿐만 아니라 소요 난방에너지 등도 분석 및 검토하였다. 이상의 결과를 요약하면 다음과 같다. 9개 지역을 대상으로 지역별 잉여 태양에너지를 대해 분석한 결과, 난방에너지 대비 잉여 태양에너지 비율은 온실 형태별로 각각 약 212.0~228.0%로서 제주가 가장 높게 나타났다. 그 다음으로 부산, 광주, 진주, 대구, 대전, 전주, 수원, 및 대관령 순으로 나타났다. 그리고 온실 형태에 관계없이 몇 몇 지역을 제외하면 잉여 태양에너지만으로 소요 난방에너지를 거의 대체할 수 있을 것으로 판단되었다.

점진부하 운동에서 중고교 엘리트 사이클 선수들의 유산소능력과 폐환기 반응 (Aerobic Capacity and Ventilatory Response During Incremental Exercise in Elite High School Cyclist)

  • 이대택;배윤정
    • 생명과학회지
    • /
    • 제20권3호
    • /
    • pp.437-443
    • /
    • 2010
  • 국내 중고교 엘리트 사이클 선수를 대상으로 점진부하 운동 시 유산소반응과 폐환기 반응을 분석하는데 목적을 두었다. 남자 사이클 선수($17{\pm}1$ 세, $175{\pm}5\;Cm$, $70{\pm}9\;kg$) 12명이 신체계측, 점진부하 운동 검사, 폐기능 검사에 참여하였다. 사이클 에르고미터를 이용한 점진부하 운동 중 이들의 최대산소섭취량($VO_2max$)과 최대파워 (Wmax), 환기량, 산소 및 이산화탄소호흡당량($V_E/VO_2$, $V_E/VCO_2$), 호흡율, 일회호흡량 등이 측정되었다. 호흡반응의 시간변인으로 흡기시간(Ti), 호기시간(Te), 일회호흡시간(Tb), 흡기의무사이클(Ti/Tb), 흡기율($V_T$/Ti)이 분석되었다. 폐기능으로는 폐활량, 일초호기량, 일초율, 최대호기량 등이 측정되었다. 선수들은 최대운동시 $57.5{\pm}3.9\;ml{\cdot}kg^{-1}{\cdot}min^{-1}$$VO_2max$, $194.1{\pm}8.6\;beat{\cdot}min^{-1}$의 최대심박수를 보였으며, Wmax 는 평균 452 W에 도달하였다. $VO_2max$은 신체계측 변인들과 상관관계를 보이지 않았다. 대부분의 환기반응은 운동강도가 점차적으로 증가하면서 동반 증가하였다. 운동강도의 증가와 함께 Ti, Te, Tb는 감소하였으며, Ti/Tb는 대략적으로 일정하게 유지되었다. 250 W 이하에서 신장, 체중, 신체질량지수, 체표면적은 $V_T$/Ti 그리고 Ti/Tb 와 높은 상관관계를 나타냈다(p<0.05). 결과적으로, 엘리트 사이클 선수들의 최대유산소능력은 성인에 비해 낮은 것으로 보이며, 이는 성인과 호흡조절 양상이 다른 것으로 추정된다. 신체계측 변인은 $VO_2max$와 상관성이 존재하지 않았다. 호흡반응의 시간 변인은 운동강도 250 W 이하에서만 체격과 연관성을 가지는 것으로 보인다. 흡기율은 어린 선수들의 운동지속시간과 연관 있어 보이지만, 흡기의무사이클은 성인과 유사한 것으로 보인다.

여름철 고온스트레스 기간에 고 양이온 사료와 반추위 보호지방과 나이아신의 추가공급시 착유우의 유생산 및 체온조절에 미치는 영향 (Effects of Higher Dietary Cation with or without Protected Fat and Niacin on the Milk Yield and Thermoregulatory Ability in Holsteins During Summer Heat Stress)

  • 김현섭;이왕식;이현준;기광석;백광수;안병석;아주말 칸
    • Journal of Animal Science and Technology
    • /
    • 제48권4호
    • /
    • pp.555-562
    • /
    • 2006
  • 본 실험은 여름철 착유우의 체온조절 능력, 산유량 및 유성분에 미치는 양이온-음이온 균형 (dietary cation-anion difference : DCAD)과 반추위 보호지방이나 나이아신의 첨가 효과를 구명하기 위하여 수행하였다. 30두의 비유중기 홀스타인 착유우 (DIM 134±12.4, 산유량 23.4±2.3kg/d)를 세개의 군으로 구분하여 배치하였다 (처리당 10두). 시험축은 후리스톨 우사에서 사육되었고, 우사에는 41cm 직경의 송풍팬이 부착되어 풍속 4 m/s로 송풍되도록 하였다. 시험축은 7월부터 8월까지 2개월동안 3가지의 시험사료를 섭취할 수 있도록 하였으며, 시험사료는 양이온-음이온 균형이 +15와 +30인 사료에 보호지방 첨가, 나머지 사료는 반추위 보호지방이나 보호지방과 나이아신을 보충하였다. 시험기간 중 7월에는 최대 온도가 28.5℃로 시험축이 약간의 고온스트레스를 받는 정도로 유지되었으나, 시험이 진행되어 8월에는 특징적인 심한 고온스트레스를 보였고, 최대온도가 32.4℃에 도달하였으며, THI는 74.0이었다. 건물, 조단백질, 가소화양분총량 섭취량은 양이온-음이온 균형 수준과 반추위 보호 지방이나 나이아신에 의하여 영향을 받지 않았으나, 산유량은 반추위 보호지방과 나이아신을 첨가한 사료를 섭취한 착유우에서 무첨가구에 비하여 높았다(P<0.05). 반추위 보호지방이나 반추위 보호지방과 나이아신을 동시에 첨가한 처리간에는 산유량의 차이는 없었다. 그리고 유지방과 직장온도도 양이온-음이온 균형 수준과 반추위 보호지방이나 나이아신 첨가에 의한 차이는 나타나지 않았다. 그러나 호흡률은 반추위 보호지방이나 반추위 보호지방과 나이아신을 동시에 첨가한 처리에서 낮게 나타났다 (P<0.05). 본 연구의 결과는 높은 수준의 양이온-음이온 균형 (+30)과 반추위 보호지방과 나이아신을 첨가하는 경우에 여름철인 7월과 8월 고온기에 홀스타인 착유우의 고온스트레스를 줄이고, 호흡율을 감소시키며, 산유량을 증가시킬 수 있음을 나타내었다.

만성 폐성심의 원인 질환 빛 예후 인자에 관한 연구 (Etiologies and Prognostic Factors of Chronic Cor Pulmonale)

  • 박융인;김상현;하재경;김성호;안병재;배우형;이현국;전국진;홍택종;박순규;신영우
    • Tuberculosis and Respiratory Diseases
    • /
    • 제47권5호
    • /
    • pp.609-617
    • /
    • 1999
  • 연구배경: 본원을 방문한 만성 폐성심 환자를 대상으로 만성폐성심의 원인 질환과 생존율 및 예후 인자에 대해 밝히고자 하였다. 방 법: 1990년 1월부터 1999년 3월까지 부산대학교 병원을 방문한 만성 폐성심 환자를 대상으로 병력지의 검토를 통해 후향적 조사가 이루어졌으며 만성 폐성심의 원인이 될 수 있는 기저 폐질환을 확인하고, 임상적으로 급성 폐성심이 의심되는 경우는 조사대상에서 제외하였다. 만성 폐성심의 진단은 일차적으로 심초음파 검사를 시행하여 우심실의 확장 또는 비대가 관찰되는 경우로 하였다. 그와 내원 당시의 임상 증상, 진찰 소견 및 각종 검사 수치를 정리 분석하였다. 결 과: 대상 환자는 총 103명이었고 남녀비는 약 1.9:1로 남자에서 많았다. 연령은 평균 $55.8{\pm}14.2$세였으며, 남자 $57.9{\pm}14.0$세, 여자 $52.0{\pm}14.1$세로 남자에서 연령이 높았다. 원인 질환으로는 폐결핵이 61명(59.2%)으로 가장 많았고, 만성폐쇄성 폐질환이 29명(28.2%)으로 다음을 차지하였다. 생존율은 1년 생존율 57%, 2년 생존율 45%, 3년 생존율 34%였다. 생존율에 미치는 변수들에 대해서는 단변량 분석 결과 최대 자발성 호흡량, 노력성 폐활량, 1초간 노력성 호기량, 혈청 나트륨, 폐활량, 혈청 알부민, 최대 호기량 등이 통계적으로 유의하였고, 다변량 분석을 통해서는 혈청 알부민(p=0.0144) 과 폐활량(p=0.0078)만이 통계적인 유의성을 가지는 변수들로 판명되었다. 결 론: 본 연구를 통해 만성 폐성심의 원인 질환으로서 폐결핵이 가장 중요하며, 만성 폐성심의 생존율은 1년 생존율 57%, 2년 생존율 45%, 3년 생존율 34%였다. 혈청 알부민(p=0.0144)과 폐활량(p=0.0078)이 통계적으로 의미있게 생존율에 영향을 미치는 변수들로 판명되었다.

  • PDF