• Title/Summary/Keyword: force system

Search Result 7,847, Processing Time 0.039 seconds

Superconducting magnetic Foce (초전도에 작용하는 자기 Force)

  • Lee, Sang-Heon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.349-350
    • /
    • 2009
  • Superconducting magnetic bearing and rotating system were developed by utilizing the high magnetization YBaCuO superconductor. The pellets prepared by quasi-melt process had a high magnetic levitation force and a high magnetic attractive force. The shaft also could be moves its position and orientation of the rotating axis freely. Is is essential to enhance the materials properties and to improve the system design for the application of the system to industrial purpose.

  • PDF

External Force Control for Two Dimensional Contour Following ; Part 2. Analysis and Implementation of Analysis Control

  • Park, Young-Chil;Kim, Sungkwun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.135-139
    • /
    • 1992
  • Control of tool-environment interaction force to comply the robot system to an environment is of vital in many automated process. This paper presents the implementation of an adaptive force control with commercial robot system in two dimensional contour following task. A model reference adaptive control system, combined with the linear compensators, is implemented. That is, a use of adaptive control is to provide an auxiliary control system so that the contour following performance can be improved from that of using linear control system only. Hyperstability is used to derive the adaptive control law. Experimental verification of the proposed control system is obtained using PUMA 560 robot system. Data obtained experimentally shows that the use of additional adaptive control system improves the contour following performance about 30% in RMS contact force errors upon that of the system controlled by the linear compensators only.

  • PDF

A Development of the Recoil Rod Pull Force Measurement System Using the Load Cell with Sleeve (슬리브관을 갖는 로드셀을 이용한 주퇴봉 당김력 계측시스템 개발)

  • Choi, Ju-Ho;Hong, Sung-Soo;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.2
    • /
    • pp.152-159
    • /
    • 2001
  • This paper presents a development of the recoil rod pull force measurement system suing the load cell with a sleeve normally available in the recoil system test. The commercial load cell cannot be used in the test of recoil system floating the breach contact point freely in the air. The load cell is designed and manufactured to meet the recoil system test condition. Theoretical analysis and experimental results show that the accuracy of the developed measurement system is within $\pm$0.5%. We notice that the measurement technique proposed in this paper is accurate and useful in the recoil rod pull force measurement of the recoil system.

  • PDF

Anslysis of tool grip tasks using a glove-based hand posture measurement system

  • Yun, Myung Hwan;Freivalds, Andris;Lee, Myun W.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.69-81
    • /
    • 1995
  • Few studies on the biomechanical analysis of hand postures and tool handling tasks exist because of the lack of appropriate measurement techniques for hand force. A measurement system for the finger forces and joint angles for the analysis of manual tool handling tasks was developed in this study. The measurement system consists of a force sensing glove made from twelve Force Sensitive Resistors and an angle-measuring glove (Cyberglove$^{TM}$, Virtual technologies) with eighteem joint angle sensors. A biomechanical model of the hand using the data from the measurement system was also developed. Systems of computerized procedures were implemented inte- grating the hand posture measurement system, biomechanical analysis system, and the task analysis system for manual tool handling tasks. The measurement system was useful in providing the hand force data needed for an existing task analysis system used in CTD risk evaluation. It is expected that the hand posture measurement developed in this study will provide an efficient and cost-effective solution to task analysis of manual tool handling tasks.s.

  • PDF

Analysis of Isolation System for Impulsive Force Device with Recoil Mechanism (반동방식 충격기구의 완충시스템 해석)

  • Kim, HyoJun;Ryu, BongJo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.272-279
    • /
    • 2005
  • In this study the optimal isolation system for the prototype HIFD(high impulsive force device) is investigated. For this purpose, firstly, the dynamic behavior of a human body and a transmitted force under specific operation conditions are analyzed through a series of experimental works using the devised test setup. In order to design the optimal dynamic absorbing system, the parameter optimization process is performed using the simplified isolation system model based on the experimental results of linear impulse and transmitted force. Finally, under the parameters satisfying the constraints of the buffering displacement and the transmitted force, the performance of the designed isolation system for the prototype HIFD is evaluated by experiment.

Mechanism and Control of Reaction Force Compensation of XY Linear Motion Stage System (XY 선형 모션 스테이지 시스템의 반발력 보상 기구와 제어)

  • Cho, Kyu-Jung;Choi, Dong-Soo;Ahn, Hyeong-Joon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.599-607
    • /
    • 2011
  • In this paper, a reaction-force compensation system for an XY linear motion stage, without an additional external isolation structure or extra motors, is developed. This system consists of a movable magnet track, a spring, a dummy weight, and a dedicated sensor module that measures the relative positions of the movable magnet track with respect to the motor coil. The reaction force compensation system is modeled, and simulations are carried out to optimize design parameters such as the moving distance of the magnet track, the transmission force, the dummy weight, and the allowed size of the mechanism. An XY linear motion stage is built, incorporating the reaction force compensation system, and the performance of the system is verified experimentally. For acceleration and deceleration values of 10 m/$s^2$, 85% of the reaction force is absorbed by the reaction force compensation system.

Implementation and Control of Compliance Emulator System (콤플라이언스 에뮬레이터 시스템의 구현 및 제어)

  • Shin, Young-Kyun;Park, Chan-Won;Kim, Whee-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.2986-2988
    • /
    • 1999
  • This paper presents a new concept to implement and to control of tactile reproduction simulator by implementation of compliance emulator system. Compliance emulator system is a kind of levitation system using magnetic force. In the compliance emulator system, a floated plate moves vertically. When an external force is applied to the plate, the system produces a controlled reaction force by using 6 electromagnet. For the control, a LVDT displacement sensor and PD control method is used.

  • PDF

Detecting Driver Fatigue by Steering Wheel Grip Force

  • LEE, KYEHOON;HYUN, SUNG-AE;OAH, SHEZEEN
    • International Journal of Contents
    • /
    • v.12 no.1
    • /
    • pp.44-48
    • /
    • 2016
  • Driver fatigue is a major cause of fatal road accidents and has significant implications in road safety. In recent years, researchers have investigated steering wheel grip force as an alternative method to detect driver fatigue noninvasively and in real time. In this study, a fatigue detection system was developed by monitoring the grip force and changes in the grip force were measured while participants' engaged in an interactive simulated driving task. The study also measured the participants' subjective sleepiness to ensure the validity of measuring grip force. The results indicated that while participants engaged in a driving task, steering wheel grip force decreased and subjective sleepiness increased concurrently over time. The possible applications of the driver fatigue detection system by steering wheel grip force and future guidelines are discussed.

Design Essential Element Technology of Catenary System be in Correspondence with Speed-up (고속화에 대응한 전차선로 설계 요소기술)

  • Chang, Sang-Hoon;Kim, Yang-Soo;Park, Byung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.05b
    • /
    • pp.75-78
    • /
    • 2005
  • The decisive criteria to determine collection performance is the contact force between pantograph and catenary. The contact force consists of a static force and dynamic force related to vibration characteristics, train speed and etc. The low contact force leads to the loss of contact, and most countries regulate it below 1% at operation speed. This study presents a technical overview of criteria for collection performance of catenary system.

  • PDF