• Title/Summary/Keyword: force/torque

Search Result 1,046, Processing Time 0.032 seconds

Axial Force of a V-Belt CVT -Experimental Study- (V-벨트 CVT의 축력해석 II -실험적 연구-)

  • 김광원;김현수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.847-854
    • /
    • 1989
  • Axial force of a V-belt CVT is investigated experimentally. The experimental results on speed ratio-torque-axial force show good agreement with the theoretical results that were obtained in the previous work. It is also found that torque capacity of the V-belt CVT increases as the axial force and the speed ratio increase. Impending slip which occurs at the maximum torque is determined via experiments for various speed ratios. Based on the impending slip region, and the theoretical curves for the speed ratio-torque-axial force relationship, an actual operating criteria for the V-belt CVT is obtained. It is suggested to use the actual operating criteria with the theoretical equations as a basic design formula for the V-belt CVT.

Development of the Method for Inspecting the Clamping Force of Torque Shear Bolts Using the Electricity energy of Electric torque wrench (전동렌치 전기에너지를 이용한 토크쉬어볼트의 체결축력 검사기법 개발)

  • Lee, Hyeon-Ju;Nah, Hwan-Seon;Kim, Kang-Sik;Kim, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.162-170
    • /
    • 2010
  • The torque-coefficient of torque-shear type high-strength bolts is affected by the environmental factors, such as 'wet', 'rust', 'exposure to air' and workability during tightening high strength bolts. It is difficult to assume the direct tension induced into the bolt due to variation of torque-coefficient for torque-shear type high-strength bolts. Therefore, it is essential to measure tension loads of bolts and to verify the clamping force under construction. In this study, the manufacture of trial product was planned to identify the induced force into the bolts. The algorithm for a trial product was composed of the relation between electricity energy taken from torque shear wrench and tension force from hydraulic tension meter. The regression analysis equation to measure the direct tension was derived by statistical analysis using Minitab program. It is considered that the trial product is reliable tool to evaluate the tension force comparable to a commercial torque wrench.

PUMA robot intelligent control using force/torque sensor (Force/Torque sensor를 이용한 PUMA Robot의 지능 제어)

  • 최성락;정광조
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.339-342
    • /
    • 1996
  • In this paper, the method for controlling PUMA robot using F/T sensor is described. In the part of the setup automation, robot is used. The F/T sensor is located at robot end-effector and various experiments are executed such as peg in hole, gripping objects, tool changing, etc.

  • PDF

The Output Analysis of Wrist Force/ Torque Sensor for SCARA Type Robots (SCARA형 로보트를 위한 손목 힘/토오크 센서의 출력 해석)

  • 고명삼;하인중;이범희;고낙용
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.8
    • /
    • pp.570-578
    • /
    • 1988
  • In order for a robot to carry out a precise assembly task with compliant motion, a force/torque sensor is needed. The output of the cross-bar structured force / torque sensor which is used in a peg-in-hole insertion task and attached to a SCARA type robot, is analzed. First, the relationship between the sensor outputs and the force / torque components obtained by the outputs is investigated. Second, in a peg-in-hole insertion task, the sensor outputs changing with the contact position of the peg and the hole, are analyzed. Also, the relative position of the peg and the hole is obtained from the sensor outputs. The peg-in-hole insertion task is successfully executed, using a SCARA type robot with a wrist force / torque sensor manufactured in our laboratory and the compliance algorithm from the results of this paper.

  • PDF

Reduction of Toque Ripple and Unbalanced Magnetic Force of a Rotatory Axial Two-Phase Transverse Flux Machine by Using Herringbone Teeth (헤링본 치를 이용한 축방향 이상 횡자속형 전동기의 토크 리플과 불평형 자기력 저감)

  • Ahn, Hee-Tae;Jang, Gun-Hee;Chang, Jung-Hwan;Chung, Shi-Uk;Kang, Do-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.682-688
    • /
    • 2008
  • Transverse flux machine (TFM) has been considered as a promising driving machine especially at the low-speed applications because it has higher power density, torque and efficiency than the conventional electrical motors. However, it has complicated structure, large torque ripple and sometimes unbalanced magnetic force due to its inherent structure. This paper investigates the characteristics of torque ripple and unbalanced magnetic force of a rotatory two-phase TFM due to the teeth geometry by using the 3-dimensional finite element method, and it develops a rotatory two-phase TFM with herringbone teeth to reduce the torque ripple as well as to eliminate the unbalanced magnetic force.

  • PDF

Full Scale Measurement Method for Rudder Torque & Force (Rudder Torque 및 Force 실선 계측 Method)

  • Lim, Jong-Ho;Park, Kyung-Rak;Ok, Yu-Kwan
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2011.09a
    • /
    • pp.1-4
    • /
    • 2011
  • The full spade rudder for the high speed has advantage to prevent gap cavitation of the rudder. DSME has developed the full spade rudder and GL has carried out CFD analysis and FE analysis to confirm strength and fatigue for DSME and Owner. Necessarily, it needs to compare rudder torque & rudder force between CFD, FE analysis and full scale measurement. This report introduces the measurement method and application of strain gauge for measuring the rudder torque and rudder force for the 8,400 TEU container ship.

  • PDF

Design of a Six Axis Force-Torque Sensor with a Cross-Shaped Structure (십자형 구조를 가진 6축 힘.토크센서의 설계)

  • Kim, Do-Seok;Yoon, Jun-Ho;Lee, Chong-Won
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.59-64
    • /
    • 2001
  • The necessity of six axis force-torque sensors have been increased in the field of automatic assembly, polishing and deburing using robotic manipulator recently. This paper presents a simple and compact elastic structure design of the six axis force-torque sensor with a cross-shaped structure and the expected deflection value was induced by theoretical method to design a six axis force-torque sensor and then this theoretical method was verified by comparing with the results using the Finite Element Method(FEM).

  • PDF

A Study on the Secure Plan of Clamping Force according to the Variation of Torque-Coefficient in Torque-Shear High Strength Bolts (토크전단형 고력볼트의 토크계수 변동에 따른 체결축력 확보방안에 관한 연구)

  • Lee, Hyeon-Ju;Nah, Hwan-Seon;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.3
    • /
    • pp.8-16
    • /
    • 2014
  • Torque control method and turn of nut method are specified as clamping method of high strength bolts in the steel construction specifications. Quality control of torque coefficient is essential activity because torque control method, which is presently adopted as clamping method in domestic construction sites, is affected by variation of torque coefficient. The clamping of torque shear bolt is based on KS B 2819. It was misunderstood that the tension force of the TS bolt was induced generally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the intended tension, as it considerably varies due to torque coefficient dependent on the environmental factors and temperature variables despite the break of the pin tail.This study was focused to evaluate the effect of environmental factors and errors of installing bolts during tightening high strength bolts. The environmental parameters were composed of 'wet' condition, 'rust' condition, 'only exposure to air' condition. And the manufacture of trial product was planned to identify the induced force into the bolts. The algorithm for a trial product was composed of the relation between electricity energy taken from torque shear wrench and tension force from hydraulic tension meter.

Firctional Behavior and Indirect Cutting Force Measurement in a Machining Center Using Feed Motor Current (머시닝센터에서 이송전류신호를 이용한 이송계의 마찰특성 규명과 이를 고려한 절삭력의 간접측정)

  • 김기대;최영준;오영탁;주종남
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.4
    • /
    • pp.78-87
    • /
    • 1997
  • In machine tools, frictional force exists between the table and the guideways, and in ballscrews. In this paper, feed motor current measured by a hall sensor is used to calculate the motor torque. Some frictional phenomena are studied in feed drive systems, such as the relationship between feedrate and frictional torque, and chip cover effects on frictional torque. Considering frictional phenomena, the relation- ship between the feed froce and the feed motor current id obtained. Feed force can be well estimated by feed motor current measurement considering frictional behavior. The relationship between the cutting force and the feed motor current is slightly different between up milling and down milling due to the effect of y direc- tional cutting force on frictional torque.

  • PDF

Hybrid Position/Force Control of 3 DOF Robot (3자유도 로봇의 하이브리드 위치/힘 제어)

  • 양선호;박태욱;양현석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.772-776
    • /
    • 1997
  • For a robot to perfom more versatile tasks, it is invitable for the robot's end-effector to come into contact with its environment. In thos case, to achieve better performance, it is necessary to properly control the contact force between the robot and the environment. In thos work, hybrid control theory is studied and is verified through experiment using a 3 DOF robot. In the experiment, two position/force controllers are used. Fist, proportional-integral-derivative controller is used as the controller for both position and force. Second, computed-torque method is used as the position controller, and proportional-integral-derivative controller is used as the force controller. For a proper modeling used in computed-torque method, the friction torque is measured by experiment, and compensation method is studied. The hybrid control method used in this experiment effectively control the contact force between the end-effector and the environment for various types of jobs.

  • PDF