• Title/Summary/Keyword: footplate

Search Result 9, Processing Time 0.019 seconds

Safety Improvement in the Curvature Motion of a High Speed Segway (고속 세그웨이의 곡선 운동에서의 안정성 향상)

  • Kim, Jihyeon;Bang, Jinuk;Lee, Jangmyung
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.2
    • /
    • pp.139-146
    • /
    • 2020
  • In this paper, the slope of the footplate is adjusted to compensate for the centrifugal force with a series elastic actuator (SEA) attached to the Segway's body to improve the cornering characteristics during turning. To ensure Segway's driving safety in the curvature motion, it is necessary to compensate for the centripetal force by tilting the footplate to generate inward force from gravity. When the footplate is tilted under the control of SEA, the vertical load on both wheels has been changed accordingly. The frictional force of the wheel has been changed by the change of the vertical force, which requires adjustment of driving torque to keep the curvature trajectory. That is, the driving torque has been controlled to keep the curvature trajectory considering the frictional force caused by the turning motion. Four SEAs are attached to the footplate to control the slope of the footplate and the real curvature motion has been demonstrated to verify the effects of SEAs in the high- speed curvature motion.

Proximal Symphalangism and Congenital Stapes Fixation (기부지절유합증을 동반한 선천성등골고정증)

  • 이철희;박영원;김종선;노관택
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.41.1-41
    • /
    • 1981
  • The combination of congenital stapes fixation and proximal symphalangism has been described in several kindreds. It exhibits autosomal dominant inheritance. A patient, 11-year-old female, visited department of otolaryngology of SNUH in December, 1980. Her complaint was bilateral hearing loss since birth. Physical examination revealed fusion of proximal interphalangeal joints of both 4th and 5th fingers. Tympanic membrane was normal. Temporal bone X-ray was normal. Pure tone audiogram revealed about 60 dB conductive loss with horizontal curve. On exploratory tympanotomy of right side, bony fixation of stapedial footplate was found. So, stapedectomy with connective tissue wire prosthesis was performed. As a result, marked improvement of hearing was obtained with 5 dB A-B gap on operated side.

  • PDF

Changes in lower extremity alignment in standing position using a foot plate

  • Lee, Hye-Mi;Yang, Ji-Eun;Lee, Ju-Yeon;Im, Hong-Jun;Jeong, Yu-Jin;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.132-137
    • /
    • 2016
  • Objective: Eversion of the foot is created with internal rotation of the shank, and inversion of the foot is created with external rotation of the shank. The purpose of the study was to investigate the effect of continuous changes in the angle of the subtalar joint on lower extremity alignments. Design: Cross-sectional study. Methods: Seventeen healthy young adult subjects recruited. The subjects were asked to stand up in a natural standing position on a footplate with eye open and equal weight on each foot for 10s in two different conditions: The right subtalar joint was everted continuously $0^{\circ}-20^{\circ}$ and in separate segments of $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$. The averages of three trials were used. The observation of the changes in the lower extremity was performed with the use of 3-dimensional motion analysis. For data analysis, the SPSS 18.0 software using paired t-test and repeated measures analysis of variance (ANOVA) was applied. Results: The angle was significantly increased at the horizontal rotation angle of the shank, thigh, and ankle without anterior rotation of the pelvis (p<0.05). The maximum horizontal rotation angle at the thigh on $20^{\circ}$ was $-4.52^{\circ}$ in static, and $-3.10^{\circ}$ in the dynamic conditions compared to $0^{\circ}$. Conclusions: Increased unilateral foot pronation, thigh, shank, ankle horizontal rotation variance was significantly effective. The observation of the changes in foot abduction with the use of a 3-dimensional motion analysis augmented in predicting the angle values of each segment of the lower extremity. In further studies, a comparison of the right and left subtalar joints need to be investigated.

Finite Element Analysis of Sound Transfer Characteristics for Middle Ear (유한요소 모델을 이용한 중이의 소리전달 특성 해석)

  • Gal, Young-Min;Baek, Moo-Jin;Lee, Doo-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1563-1571
    • /
    • 2011
  • In this study, we developed a finite element model of the human middle ear has been developed to calculate itsfor sound transfer characteristics calculation. We usedThe geometric data forof ossicles, obtained byfrom micro-CT scanning, was used in order to develop the middle- ear FE model. A right- side temporal bone of a Korean cadaver was used for the micro-CT scanning. The developed FE model includes three ossicles, the tympanic membrane, ligaments, and muscles. We calculated theA sound transfer function from the tympanic membrane to the stapes footplate was calculated. The sound transfer function calculated vias of the FE model shows good agreement with measured responses over the 10- kHz frequency band. To measureidentify the sensitivityies of the middle- ear function due to material property variation, we studied several parameters studies have been fulfilled using the middle ear FE model. TAs a result the stiffness property of the incudostapedial joint had the greatest influence onwas the most influential to the middle- ear sound transfer function among the parameters.

Strategies for Driving and Egress for the Vehicle of a Humanoid Robot in the DRC Finals 2015 (DRC Finals 2015 에서 휴머노이드 로봇의 자동차 운전과 하차에 관한 전략)

  • Ahn, DongHyun;Shin, JuSeong;Jun, Youngbum;Sohn, Kiwon;Jang, Giho;Oh, Paul;Cho, Baek-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.11
    • /
    • pp.912-918
    • /
    • 2016
  • This paper presents various strategies for humanoid vehicle driving and egress tasks. For driving, a tele-operating system that controls a robot based on a human operator's commands is built. In addition, an autonomous assistant module is developed for the operator. Normal position control can result in severe damage to robots when they egress from vehicles. To prevent this problem, another approach that mixes various joint control techniques is adopted in this study. Additionally, a footplate is newly designed and attached to the vehicle floor for the ground landing phase of the egress task. The attached plate enables the robot to step down onto the ground in a safe manner. For stable locomotion, a balance controller is designed for the humanoid. For the design of the controller, the robot is modeled using an inverted pendulum that consists of a spring and a damper. Then, a state feedback controller (with pole placement and a state observer) is built based on the simplified model. Many approaches that are presented in this paper were successfully applied to a full-sized humanoid, DRC-HUBO+, in the DARPA Robotics Challenge Finals, which were held in the United States in 2015.

An Anatomical Study of the Posterior Tympanum (한국인 중이강후벽에 관한 형태해부학적 고찰)

  • 양오규;윤강묵;심상열;김영명
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.17.2-19
    • /
    • 1982
  • The sinus tympani is subject to great variability in the size, shape and posterior extent. A heavy compact bony zone, especially in the posterior portion and the narrow space between the facial nerve and posterior semicircular canal are the limitation of surgical approach. The facial recess should be opened, creating a wide connection between the mesotympanum and mastoid in the Intact canal wall tympanoplasty with mastoidectomy. The surgically created limits of the facial recess are the facial nerve medially, the chorda tympani laterally and the bone adjacent to the incus superiorly. Using adult Korean's thirty-five temporal bones, the authors measured the osteologic reslationship in the posterior tympanum, especially sinus tympani and facial recess. The result was as followed. 1. The average distance from the anterior end of the pyramidal eminence. 1) to the edge of the sinus tympani directly posterior was 2.54(1.05-5.40)mm. 2) to the maximum posterior extent was 3.22(1.25-7.45)mm. 3) to the maximum cephaled extent was 0.67 (0.40-1.75)mm. 2. The boundary of the sinus tympani was 82.9% from the lower margin oval window to the upper margin round window niche. 3. The deepest part of the sinus tympani was 62.9% in the mid portion, between the ponticulus and subiculum. 4. The oblique dimension from the fossa incudis above to the hypotympanum below was 8.13(7.90-9.55)mm. 5. The transverse dimensions midway between the oval window above and round window below was 3.00(2.85-3.45)mm. 6. The transverse dimension at the level of the fossa incudis was 1.81(1.40-2.15)mm. 7. The facial nerve dehiscence was 14.3%. 8. Anterior-posterior diameter of the footplate was 2.98(2.85-3.05) mm. 9. The average distance from the footplate. 1) to the cochleariform process was 1.42(1.35-1.55) mm. 2) to the round window niche was 1.85(1.45-2.10) mm.

  • PDF

Lumped Mechanical Model of Electromagnetic Floating Mass Transducer Implanted on Human Middle Ear (이소골에 장착된 전자기 플로팅매스 진동체에 대한 집중 질량-스프링 모델의 제안)

  • Seong, Ki-Woong;Kim, Min-Woo;Lee, Jang-Woo;Lim, Hyung-Gyu;Jung, Eui-Sung;Kim, Dong-Wook;Lee, Myung-Won;Lee, Jung-Hyun;Kim, Myoung-Nam;Lee, Kyu-Yeop;Lee, Sang-Heun;Park, Il-Yong;Cho, Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.162-168
    • /
    • 2009
  • Implantable middle ear hearing devices (IMEHDs) have been widely studied as an alternative hearing aids to solve the problems of conventional hearing aids. Vibration transducer of middle ear hearing aids is a key component because vibration characteristics of transducer is directly involved performance of hearing aids. So, the study about middle ear hearing aids concentrate on the transducers. A floating mass type transducer is most efficient. In this paper, we suggest a lumped mechanical model of electromagnetic floating mass transducer implanted on human middle ear. The proposed model enables analysis of the vibration characteristics of a floating mass transducer and prediction of the variation after implant on ossicle that offers a simple and easy to analyze. The parameters was drawn based on the components and the structures of transducer. The Lumped mechanical model was converted by the electrical-mechanical equivalent model, and simulated using PSpice. So, we investigated vibration characteristics of transducer influenced it's components. And we predict vibration characteristics of stapes footplate due to implanted transducer's vibration using combining model of transducer and human ear. To prove the feasibility of the suggested model, we fabricated a differential floating mass transducer (DFMT) as one of floating mass transducers and performed experiments using the human temporal bones.

Measurement of transmitted vibration to stapes and tympanic membrane by DFMT's vibration in implantable middle ear hearing devices (중이 이식형 보청기에서 DFMT의 진동에 의한 등골 및 고막 방향으로 전달되는 진동력 측정)

  • Lee, Myoung-Won;Seong, Ki-Woong;Lim, Hyung-Gyu;Kim, Min-Woo;Jung, Eui-Sung;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Lee, Sang-Heun;Lee, Kyu-Yup;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.286-293
    • /
    • 2009
  • The implantable middle ear hearing devices(IMEHDs) have been developed to overcome the conventional hearing aid's problem(ringing effect caused by the acoustic feedback, cosmetic problem, etc.). In the IMEHDs, the vibrating transducer is a key component because its vibration enables to hear for hearing impaired people. The vibrating transducer is implanted on ossicular chain by surgical operation. The coupling status between implanted transducer and ossicular chain has an effect on delivering vibrating force from transducer to stapes. Noninvasive method is required to investigate the output characteristics of IMEHDs after implementation. Recently, emitted sound pressure measuring method of tympanic membrane is proposed to investigate the output characteristics of IMEHDs. However, the relationship between displacement of stapes and sound pressure by tympanic membrane was not cleared. In this paper, displacement of stapes and sound pressure by tympanic membrane were measured using the differential floating mass transducer(DFMT) that implanted on the ossicular chain of the human temporal bone and physical ear model. Through the experiments results, the relationship between displacement of stapes and sound pressure by tympanic membrane was investigated.

A Study of Structural Analysis Simulation for Squat Exercise Foot Plate (스쿼트운동장치의 풋플레이트 구조해석에 관한 연구)

  • Jung, Byung-Geun;Kim, Ji-won;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.9
    • /
    • pp.365-372
    • /
    • 2017
  • Squat exercise is one of the important free weight exercises that can safely and effectively expect the athletic performance by establishing the rationale. Therefore, it is necessary to study the side effects caused by incorrect exercise, scientific countermeasures and to develop a exercise estimation model. It is effective and accurate to use a variety of assistive devices to calibrate athletic posture. The issues of the structural analysis for designing a foot plate for squat exercise is to model the behavior by the dynamic behavior. It should be consider that the center of gravity of each segmented body is different when the maximum load is applied. It is applied to complete system design through simulation method with kinematic dynamic, ground reaction force and load analysis for the free weight exercise equipment, VR device, and safety foot plate. In this paper, the authors propose the design method for the vertical load distribution applied in the design of the foot plate used for the squat exercise mechanism, and based on these results, design make the more safe and reliable free weight exercise equipment system.