A study on the measurement of Radiative Heat flux form the flame(I) -Design and Calibration of a Heat flux meter- (화염으로부터의 복사 열유속의 계측 I)

  • 정종수;인종수;김승수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.2
    • /
    • pp.484-491
    • /
    • 1990
  • A heat-flux meter has been designed and manufactured to measure the heat flux from the flame. A calibration method of the heat-flux meter by a calibration furnace has also been proposed. The k-type (Chromel-Alumel) thermocouple material has been used as the material for the beat-flux meter. The electormotive force (e.m.f.) from the K-type thermocouple is shown to be linearly proportional to the heat flux absorbed. The characteristics of the heat-flux meter become better as the radius of heat absorbing disk becomes larger and its thickness thinner.

Drift Self-compensating Type Flux-meter for Automatic Magnetic Flux Measurement

  • Ga, E.M.;Son, D.;Bak, J.G.;Lee, S.G.
    • Journal of Magnetics
    • /
    • v.8 no.4
    • /
    • pp.160-163
    • /
    • 2003
  • In magnetic flux measurement, output voltage drift of electronic integrator is an essential problem. In this work, we have developed a new kind of Miller type integrator using a sample and hold amplifier. Input bias current was measured and this value was hold in the sample and hold amplifier, after that input bias current of Miller integrator was compensated automatically using the value which holds in the sample and hold amplifier. Developed flux-meter shows the drift of flux-meter are smaller than 10$^{-5}$ Wb/min in full scale of 10$^{-2}$, and we could also measure multi-channel magnetic flux simultaneously.

Drift Self-compensating type Flux-meter Using Digital Sample and Hold Amplifier (Digital Sample and Hold 증폭기를 사용한 드리프트 자체 보상형 자속계의 제작)

  • Ka, Eun-Mie;Son, De-Rac
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.6
    • /
    • pp.332-335
    • /
    • 2005
  • Output voltage of the flux-meter has always drift due to the input bias current of non-ideal operational amplifier. In this study we have employed a digital sample and hold amplifier which has no voltage drop to compensate drift of the flux-meter automatically. The drift of the developed flux-meter was smaller than $5{\times}10^{-8}\;Wb/s$ for the integration time constant of $RC=10^{-3}$ s.

Effective thermal conductivity of the phase change material with metal scrap (금속스크랩이 혼합된 상변화물질의 유효열전도율)

  • 김시범;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.923-928
    • /
    • 1986
  • A set of measurements has been made for the thermal conductivity of the pure paraffin in liquid and solid phases and for the effective thermal conductivity of the paraffin with metal scrap with the aid of the heat flux meter. Ther thermopile-type heat flux meter has been designed by steady state method and the functional relation between the temperature difference of both sides and heat flux has been obtained. The measured values of thermal conductivity are compared with the existing data for the pure paraffin and with the predicated values from the suggested model in which only one empirical constant is contained. The comparison within ten percent of the volume fraction of the metal scrap in the paraffin is satisfactory.

A Basic Study on the Low Drift Flux Meter by Using a Peltier Device (펠티어 소자를 사용한 Low Drift Flux Meter의 기초연구)

  • Kim, Chul-Han;Heo, Jin;Shin, kwang-Ho;Sa-Gong, Geon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.11
    • /
    • pp.912-916
    • /
    • 2001
  • Fluxmeter is a measuring instrument the magnetic flux intensity by means of an integration of the voltage induced to a search coil to unit time. It also is required to a precise integrator since the voltage induced to a search coil has a differential value of the flux ${\Phi}$ to unit time. In this study, a bias current which is a main problem of the integrator in a drift troublesome depending on the temperature of a FET is investigated. We have confirmed that the temperature dependence of both the bias current of a integrator using the FET and the reversal saturated current of the minor carrier in a P-N junction of a semiconductor were the same. The property of a commercial integrator goes rapidly down with increasing temperature. The bias current of a FET is increased twice as much with 10$^{\circ}C$ increment. As a result, the low drift integrator could be developed by setting the lower temperature up with a pottier device.

  • PDF

A Study on the Heat Flux Meter Location for the Performance Test of a Refrigerator Vacuum Insulation Panel (냉장고 진공단열재 성능진단을 위한 열유속계 위치에 관한 연구)

  • Ha, Ji Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.471-476
    • /
    • 2013
  • The present study has been carried out to elucidate the optimal method for the performance test of a refrigerator vacuum insulation panel (VIP), by using numerical heat transfer analysis. Three locations of heat flux meter have been tested, for deriving the best test method to clarify the normal or the abnormal condition of the vacuum insulation panel in a refrigerator. The first location of the heat flux sensor is at the same place as the heater, the second one is at the nearby side location of the heater and the third one is at the opposite side location of heater in the refrigerator. The heat flux and $1/q^{{\prime}{\prime}^2}$ or $q^{{\prime}{\prime}^4}$ were calculated for the cases with the normal VIP, and with the abnormal VIP, and their differences analyzed. From the present study, the first and the second method had a mere difference characteristics of heat flux and $1/q^{{\prime}{\prime}^2}$ or $q^{{\prime}{\prime}^4}$, between the cases with the normal or the abnormal VIP. The magnitude of the heat flux after 300sec had a great difference between the cases with the normal or abnormal VIP for the third method, and it could be considered the most optimal method to test the performance of a refrigerator vacuum insulation panel.

Effects of CO2 on Heat Transfer from Oxygen-Enriched Hydrogen Flame (이산화탄소가 수소 산소부화 화염의 열전달에 미치는 영향)

  • Lee, Chang-Yeop;Choi, Joon-Won;Baek, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.937-944
    • /
    • 2004
  • An experimental study has been conducted to evaluate the effects of $CO_2$ on heat transfer from oxygen-enriched hydrogen flame. Experiments were performed on flames stabilized by a co-flow swirl burner, which was mounted on top of the furnace. Five different oxidizer compositions were prepared by replacing $N_2$ with $CO_2$. In a steady state, the total as well as radiative heat flux from the flame to the wall of furnace have been measured using a heat flux meter. Temperature distribution in furnace also has been measured and compared. By increasing $CO_2$ proportion in the oxidizer, the convection played a more significant role rather than radiation. Overall temperature in the furnace was seen to be decreased, while the total heat flux has increased.

Comparison between Passive Flux Meters and Borehole Dilution Tests to Estimate Groundwater Flux in a Karst Aquifer (플럭스미터와 단공희석시험을 이용한 카르스트 대수층 내 지하수 플럭스 측정 비교)

  • Lee, Juyeon;Yang, Minjune
    • Economic and Environmental Geology
    • /
    • v.53 no.5
    • /
    • pp.543-552
    • /
    • 2020
  • In this study, we measured groundwater fluxes with a passive flux meter and a borehole dilution test in the Upper Floridan Aquifer. In addition, the feasibility of the passive flux meter is also evaluated within matrix and non-matrix zones. The results of the PFM (5.96 ± 1.75 cm/day) showed good agreement with those of the BHD (4.68 ± 2.99 cm/day) in matrix zones, whereas the results of the PFM (9.94 ± 0.90 cm/day) showed poor agreement with those of the BHD (1817.37 ± 1795.50 cm/day) in non-matrix zones. We assumed that the groundwater passes through the sorbent material inside the PFM. However, it could not pass through the sorbent when the groundwater flux is faster than 11 cm/day. The flow might bypass between monitoring well and the PFM. The PFM used in this study might be suitable for measuring the groundwater fluxes under 11 cm/day. Therefore, more extensive research is needed in the future to measure fast groundwater fluxes (> 11 cm/day).

Stator Flux Vector Control Of Induction Motor using Parameter Estimation (파라메터 추정을 통한 유도전동기의 고정자 자속 기준 벡터 제어)

  • Hahm, Nyun-Kun;Jun, Kee-Young;Kim, Sung-Nam;Lee, Seung-Hwan;Lee, Hoon-Goo;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2123-2125
    • /
    • 1997
  • In the induction motor control, the rotator flux estimation methods are used in the implement vector control of the induction motor instead of the potentical-meter or tacho-meter, a system is very sensitive in noise. In this paper, the parameters that do not affect the stablity of the system were applied in Off-Line tuning methods. In case of the rotator resistor that is sensitive. On-Line tuning methods applied in the steady state. We ascertained that the utility of a theory applied in stator flux orientation vector control through the simulation.

  • PDF

Simulations and Circuit Layouts of HTS Rapid Single Flux Quantum 1-bit A/D Converter by using XIC Tools (XIC tools을 사용한 고온 초전도 Rapid Single Flux Quantum 1-bit A/D Converter의 Simulation과 회로 Layout)

  • 남두우;홍희송;정구락;강준희
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.131-134
    • /
    • 2002
  • In this work, we have developed a systematic way of utilizing the basic design tools for superconductive electronics. This include WRSPICE, XIC, margin program, and L-meter. Since the high performance analog-to- digital converter can be built with Rapid Single Flux Quantum (RSFQ) logic circuits the development of superconductive analog-to-digital converter has attracted a lot of interests as one of the most prospective area of the application of Josephson Junction technology. One of the main advantages in using Rapid Single Flux Quantum logic in the analog-to-digital converter is the low voltage output from the Josephson junction switching, and hence the high resolution. To design an 1-bit analog-digital converter, first we have used XIC tool to compose a circuit schematic, and then studied the operational principle of the circuit with WRSPICE tool. Through this process, we obtained the proper circuit diagram of an 1-bit analog-digital converter circuit. Based on this circuit we performed margin calculations of the designed circuits and optimized circuit parameters. The optimized circuit was laid out as a mask drawing. Inductance values of the circuit layout were calculated with L-meter. Circuit inductors were adjusted according to these calculations and the final layout was obtained.

  • PDF