• 제목/요약/키워드: flux loss

검색결과 484건 처리시간 0.034초

A Study on the Iron Loss and Demagnetization Characteristics of an Inset-type Flux-Reversal Machine

  • Kim, Tae Heoung
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.297-301
    • /
    • 2013
  • Flux-reversal machine (FRM) is cost effective and suitable for mass production due to its simple structure. However, there is a notable permanent magnet flux leakage which deteriorates the performance. To compensate this drawback with a design method, an Inset-Permanent-Magnet-Type FRM (ITFRM) has been proposed. The ITFRM has permanent magnets perpendicular to the stator teeth surface, and thus, is much more difficult to demagnetize. In this paper, we deal with the iron losses and irreversible permanent magnet demagnetization characteristics of the ITFRM according to various design variables and driving conditions. To analyze the characteristics, a two-dimensional finite-element method (2D-FEM) considering nonlinear analysis of permanent magnets is used. As a result, we propose the design variables that have the largest effects on the iron losses and irreversible magnet demagnetization.

고지재생연구(제12보) -부상부유 처리의 미세분 분급 선택성과 효율 상승을 위한 처리조건- (Recycling of Wastepaper(12) -Froth-Flotation Conditions for Enhancement of Fines Fractionation Selectivity and Efficiency-)

  • 여성국;류정용;신종호;송봉근;서영범
    • 펄프종이기술
    • /
    • 제33권1호
    • /
    • pp.16-23
    • /
    • 2001
  • Hydraulic transport of fines up to the surface of flotation cell was supposed to be a mechanism of fines fractionation through the froth-flotation. Efficient fractionation of fines means efficient skimming out of flotation rejects as much as possible with least long fiber loss. The selectivity of fines fractionation was found to be mainly affected by long fibers flocculation degree in this study. Lack of sufficient flocculation of long fibers could lead to extensive loss of long fibers. It was also found that higher flotation flux caused higher flotation reject as well as the increase of long fiber loss, but did not affect the fine content ratio in the flotation reject. We controlled the flotation flux and the stock consistency, and chose a cationic polymer to maximize the flocculation of long fibers and to increase the amount of flotation reject. The highest efficiency of fines fractionation was obtained at 1.3% of stock consistency and at 100L/min of flotation flux in our experimental set up. The cationaic polymer we chose was found to be very effective in fiber flocculation and flotation froth stabilization. New definitions of fractionation efficiency were introduced in this study to compare the results more clearly.

  • PDF

낙동강 구미 보의 수면 열수지 계절 변화 (Seasonal Variation of the Surface Heat Budget in the Gumi Reservoir of Nakdong River)

  • 김학윤;서광수;조창범;김해동
    • 한국환경과학회지
    • /
    • 제25권8호
    • /
    • pp.1057-1063
    • /
    • 2016
  • The heat budget is investigated in the Gumi Reservoir of the Nakdong river. In warm climate season, solar radiation effects play a important role in the change of water temperature. The features of the surface heat balance are almost derived by the latent heat flux and the solar radiation flux. On the other hand, in cold climate season, change of heat stored in the water is mainly dominated by latent and sensible heat transfer between water and air, since flux of solar radiation and loss of outgoing long wave radiation balance approximately. For the annual averages, net flux of radiation, evaporation(latent heat) loss are dominant in the Gumi reservoir. The evaporation losses are dominant from spring to early winter. This means that the Gumi reservoir rolls like a lake of thermal medium or deep depth.

고속용 전동기에 사용되는 실리콘 규소 강판의 철손 계수 산정 (Iron Loss Coefficient Calculation of the Silicon Steel for High Speed Motor)

  • 장석명;조성국;조한욱;양현섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.128-130
    • /
    • 2003
  • For electrical machine designers, core loss data are usually provided in the form of tables or curves of total loss versus flux density or frequency. The aim of this work is to propose a mathematical model for the iron losses prediction in soft magnetic material$ with any frequency and flux density. In this paper, three formulas for calculating the iron loss coefficients are discussed. And the coefficients are applied to calculate the iron loss of the 25kW high speed motor.

  • PDF

맥동관냉동기의 정상상태 질량흐름에 의한 엔탈피손실 (Enthalpy Flow Loss by Steady Mass Streaming in Pulse Tube Refrigerators)

  • 백상호;정은수
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.623-631
    • /
    • 2000
  • Effects of the taper angle and the angular velocity of a pulse tube on the enthalpy flow loss associated with the steady mass streaming were analysis by two-dimensional analysis of a pulse tube with variable cross-section. It was shown that the steady mass flux can lead to a large steady second-order temperature. The enthalpy flow loss associated with the steady mass streaming increases as the angular velocity increases. For a pulse tube where the viscous penetration depth is far thinner than the inner radius, the enthalpy flow loss can be significantly reduced by tapering the pulse tube since both the steady mass flux and the steady second-order temperature decrease as the taper angle increase.

  • PDF

오버행을 가지는 SMC재질을 이용한 BLDC전동기의 3차원 철손 해석 (3-D Core Loss Calculation in BLDC Motor having Overhang made of SMC Material.)

  • 이상호;이지영;남혁;홍정표;허진;성하경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1043-1045
    • /
    • 2004
  • This paper deals with the core loss calculation of a BLDC motor made of Soft Magnetic Composite material. Since the teeth of motor partially have overhang in axial direction, 3 - dimensional equivalent magnetic circuit network (3D-EMCN) is used as an analytical method to get flux density of each element. The total core loss is calculated with the magnetic flux density and core loss curves of the SMC material. The calculated result is compared with core loss of the motor without overhang in stator teeth.

  • PDF

FINITE ELEMENT ANALYSIS OF ROTATIONAL HYSTERESIS LOSS USING TWO DIMENSIONAL PERMEABILITY TENSOR

  • Lee, Hak-Yong;Jung, Hyun-Kyo;Hahn, Song-Yop;Park, Gwan-Soo
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.837-840
    • /
    • 1995
  • Finite element analysis using two dimensional magnetic permeabillity tensor that can represents phase lag between magnetic field intensity and flux density under rotational flux is examined. Considered problem is confined to two dimensional magnetostatic case. And we applied proposed method to calculate the core loss of the test model and compare the result with that of experiment.

  • PDF

EVALUATION OF HEAT-FLUX DISTRIBUTION AT THE INNER AND OUTER REACTOR VESSEL WALLS UNDER THE IN-VESSEL RETENTION THROUGH EXTERNAL REACTOR VESSEL COOLING CONDITION

  • JUNG, JAEHOON;AN, SANG MO;HA, KWANG SOON;KIM, HWAN YEOL
    • Nuclear Engineering and Technology
    • /
    • 제47권1호
    • /
    • pp.66-73
    • /
    • 2015
  • Background: A numerical simulation was carried out to investigate the difference between internal and external heat-flux distributions at the reactor vessel wall under in-vessel retention through external reactor vessel cooling (IVR-ERVC). Methods: Total loss of feed water, station blackout, and large break loss of coolant accidents were selected as the severe accident scenarios, and a transient analysis using the element-birth-and-death technique was conducted to reflect the vessel erosion (vessel wall thickness change) effect. Results: It was found that the maximum heat flux at the focusing region was decreased at least 10% when considering the two-dimensional heat conduction at the reactor vessel wall. Conclusion: The results show that a higher thermal margin for the IVR-ERVC strategy can be achieved in the focusing region. In addition, sensitivity studies revealed that the heat flux and reactor vessel thickness are dominantly affected by the molten corium pool formation according to the accident scenario.

누설자속에 의한 대용량 변압기의 권선지지구조 및 외함의 와전류손실 계산에 관한 연구 (The Loss Calculation of Eddy Current of the Tank and Winding Supports in Transformers by the Leakage Flux)

  • 허우행;이동엽;김규탁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.948-950
    • /
    • 2005
  • This paper compared the test data with the loss when a conductor is exposed to the magnetic fieldof reactors after generating external magnetic field in specimen by means of an air core reactor model and the calculation of loss came from a tying the combination of FEM and integral method. It was applied to the loss measurement of transformers due to leakage flux.

  • PDF

자속구속형 고온초전도 사고전류제한기의 히스테리시스 특성 (Hysteresis Characteristics of Flux-Lock Type Superconducting Fault Current Limiter)

  • 임성훈
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.66-70
    • /
    • 2007
  • For the design to prevent the saturation of the iron core and the effective fault current limitation, the analysis for the operation of the flux-lock type superconducting fault current limiter (SFCL) with consideration for the hysteresis characteristics of the iron core is required. In this paper, the hysteresis characteristics of the flux-lock reactor, which is an essential component of the flux-lock type SFCL, were investigated. Under normal condition, the hysteresis loss of the iron core in the flux-lock type SFCL does not happen due to its winding structure. From the equivalent circuit for the flux-lock type SFCL and the fault current limiting experiments, the hysteresis curves could be drawn. From the analysis for both the hysteresis curves and the fault current limiting characteristics due to the number of turns for the 1st and 2nd windings, the increase of the number of turns in the 2nd winding of the flux-lock type SFCL had a role to prevent the iron core from saturation.