• Title/Summary/Keyword: flux flow step

Search Result 46, Processing Time 0.018 seconds

Performance evaluation of forward osmosis (FO) hollow fiber module with various operating conditions (중공사막 모듈을 이용한 정삼투 공정에서의 운영조건 변화에 따른 성능평가)

  • Kim, Bongchul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.4
    • /
    • pp.357-361
    • /
    • 2018
  • Forward osmosis (FO) process has been attracting attention for its potential applications such as industrial wastewater treatment, wastewater reclamation and seawater desalination. Particularly, in terms of fouling reversibility and operating energy consumption, the FO process is assumed to be preferable to the reverse osmosis (RO) process. Despite these advantages, there is a difficulty in the empirical step due to the lack of separation and recovery techniques of the draw solution. Therefore, rather than using FO alone, recent developments of the FO process have adapted a hybrid system without draw solution separation/recovery systems, such as the FO-RO osmotic dilution system. In this study, we investigated the performance of the hollow fiber FO module according to various operating conditions. The change of permeate flow rate according to the flow rates of the draw and feed solutions in the process operation is a factor that increases the permeate flow rate, one of the performance factors in the positive osmosis process. Our results reveal that flow rates of draw and feed solutions affect the membrane performance, such as the water flux and the reverse solute flux. Moreover, use of hydraulic pressure on the feed side was shown to yield slightly higher flux than the case without applied pressure. Thus, optimizing the operating conditions is important in the hollow fiber FO system.

A New VOF-based Numerical Scheme for the Simulation of Fluid Flow with Free Surface(I)-New Free Surface Tracking Algorithm and Its Verification- (자유 표면이 존재하는 유체 유동 해석을 위한 VOF방법의 기반의 새로운 수치 기법(I)-새로운 자유 표면 추적 알고리즘 및 검증-)

  • Kim, Min-Su;Sin, Su-Ho;Lee, U-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.12
    • /
    • pp.1555-1569
    • /
    • 2000
  • Numerical simulation of fluid flow with moving free surface has been carried out. For the free surface flow, a VOF(Volume of Fluid)-based algorithm utilizing a fixed grid system has been investigated. In order to reduce numerical smearing at the free surface represented on a fixed grid system, a new free surface tracking algorithm based on the donor-acceptor scheme has been presented. Novel features of the proposed algorithm are characterized as two numerical tools; the orientation vector to represent the free surface orientation in each cell and the baby-cell to determine the fluid volume flux at each cell boundary. The proposed algorithm can be easily implemented in any irregular non-uniform grid systems that are usual in finite element method (FEM). Moreover, the proposed algorithm can be extended and applied to the 3-D free surface flow problem without additional efforts. For computation of unsteady incompressible flow, a finite element approximation based on the explicit fractional step method has been adopted. In addition, the SUPG(streamline upwind/Petrov-Galerkin) method has been implemented to deal with convection dominated flows. Combination of the proposed free surface tracking scheme and explicit fractional step formulation resulted in an efficient solution algorithm. Validity of the present solution algorithm was demonstrated from its application to the broken dam and the solitary wave propagation problems.

Removal of Hardness Ions by Crossflow Ceramic Ultrafiltration Process with Adding Lime-soda Ash (석회-소다회를 주입한 십자흐름 세라믹 한외여과공정을 이용한 경도 이온 제거)

  • Park, Jin-Yong;Park, Bo-Reum
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.191-196
    • /
    • 2007
  • In the study, excess of lime-soda ash(L-S) was added to groundwater for chemical precipitation of hardness ions. After formation of the coagulated flocs, sedimentation step was replaced with crossflow ultrafiltration(UF) process using tubular ceramic membrane. As results, our treated water was below total hardness(TH) 10 mg/L as $CaCO_3$ from groundwater using washing water in a soymilk factory. Then, we investigated the change of permeat flux(J) and dimensionless permeate flux($J/J_0$) during experiments for variations of TMP(Trans-membrane pressure) or flow rate, to see effect of TMP or flow rate on membrane fouling by the coagulated Inorganic flocs. In the result, membrane fouling and rejection rate of total hardness were not affected by TMP and flow rate variations in the range of our experiments.

Simulation of Viscous Flow Past NACA 0012 Poil using a Vortex Particle Method (보오텍스 방법에 의한 순간 출발하는 2차원 날개 주위의 점성유동 모사)

  • Lee S. J.;Kim K. S.;Suh J. C.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.161-165
    • /
    • 2004
  • In the vortex particle method based on the vorticity-velocity formulation for solving the Wavier-Stokes equations, the unsteady, incompressible, viscous laminar flow over a NACA 0012 foil is simulated. By applying an operator-splitting method, the 'convection' and 'diffusion' equations are solved sequentially at each time step. The convection equation is solved using the vortex particle method, and the diffusion equation using the particle strength exchange(PSE) scheme which is modified to avoid a spurious vorticity flux. The scheme is improved for variety body shape using one image layer scheme. For a validation of the present method, we illustrate the early development of the viscous flow about an impulsively started NACA 0012 foil for Reynolds number 550.

  • PDF

Properties of $MgB_2$ Intragrain Nanobridges ($MgB_2$ 결정립 나노브릿지 특성에 관한 연구)

  • Hong, Sung-Hak;Lee, Soon-Gul;Seong, Won-Kyung;Kang, Won-Nam;Kim, Dong-Ho;Kim, Young-Kuk;Chung, Kook-Chae
    • Progress in Superconductivity
    • /
    • v.10 no.2
    • /
    • pp.74-78
    • /
    • 2009
  • Inter-grain nanobridges of the $MgB_2$ superconductor have been fabricated by focused-ion-beam(FIB) and their electrical transport properties were studied. The $MgB_2$ film was prepatterned into microbridges by a standard argon ion milling technique and then FIB-patterned into 100 nm$\times$100 nm bridges. Current-voltage characteristics showed a strong flux-flow type behavior at all temperatures with a trait of Josephson coupling near $T_c$. At low temperatures, the curves showed a two-step resistance-doubled transition with occasional hysteresis. The resistance-doubling transition is believed to be due to a two-channel flux-flow effect. The temperature-dependent critical current data showed $I_c(T){\propto}(1-T/T_c)^2$ near $T_c$, same as a normal barrier junction, and $I_c(T){\propto}(1-T/T_c)^{1.2}$ at low temperatures, similar to that of a film.

  • PDF

[ $Bi_2Sr_2CaCu_2O{8+\delta}$ ] Intrinsic Josephson Junctions in a Parallel Magnetic Field

  • Lee, J.H.;Chong, Yon-Uk;Lee, Su-Youn;Khim, Z.G.
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.110-114
    • /
    • 2000
  • We have investigated the Josephson vortex dynamics in $Bi_2Sr_2CaCu_2O{8+\delta}$ intrinsic Josephson junctions subjected to a magnetic field parallel to $CuO_2$ planes. We investigated mesas with $40\times40{\mu}m^2$ in size and containing 6 and 20. intrinsic junctions. The zero field I-V characteristics exhibited a typical hysteretic, multi-branched nature of the intrinsic Josephson effect. At high magnetic fields (H>1.5 T), I-V characteristics showed flux flow steps. The Swihart velocity obtained from this observation was about $4.2\times10^5$ m/s, which was the lowest mode electromagnetic wave velocity of N coupled stack. The experimental I-V curves fitted well into the simple model of Cherenkov radiation including Ohmic and non-linear dissipation terms. This suggests that the dissipation mechanism of Josephson vortex be due to both Cherenkov radiation and quasiparticle tunneling current.

  • PDF

A Study on the Analysis of Dynamic Characteristics of the Solenoid Valve of Automatic Transmission (A/T용 솔레노이드 밸브의 동특성 해석에 관한 연구)

  • Song, Chang-Seop;Lee, Yong-Ju;You, Se-Joon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.8
    • /
    • pp.122-130
    • /
    • 1995
  • To reduce the shock in shifting, the clutches and the brakes in automatic transmission have to be connected smoothly and disconnected rapidly. It is PCSV(Pressure Control Solenoid Valve) that paly this role of automatic transmission. In this paper, there were two steps in the analysis of the PCSV. The first step was modeling the elctromagnet by the permeance method. The second step was modeling the hydraulic circuit by the pressure differential equa- tion. In addition to this modeling, a experiment was performed and the commercial package program was used in order to justify modeling. The result of modeling coincide with the result of experiment and commercial package program. As a result, this modeling is usable in analysis of dynamic characteristics of the PCSV.

  • PDF

산소 및 아르곤 이온 보조빔을 이용하여 증착한 저온 Indim Tin Oside(ITO) 박막의 특성 연구

  • 김형종;김정식;배정운;염근영;이내응;오경희
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.100-100
    • /
    • 1999
  • 가시광선 영역에서 높은 광학적 투과성과 함께 우수한 전기 전도성을 갖는 ITO 박막은 디스플레이 소자나 투명전극재료 등 다양한 분야에서 응용성이 더욱 증대되고 있다. 증착기판으로서 유리를 사용할 때 생기는 활용범위 제한을 극복하고자 최근 유기물 위에 증착이 가능한 저온 증착방법에 대한 연구가 활발히 이루어지고 있다. 그 가운데 이온빔과 같은 energetic한 beam을 이용한 박막의 제조는 기판을 플라즈마 발생지역으로부터 분리시켜 이온빔의 flux 및 에너지, 입사각 등의 자유로운 조절을 통해 상온에서도 우수한 성질의 박막 형성 가능성이 제시되어 왔다. 본 연구에서는 ion beam assisted evaporation방법을 이용하여 ITO 박막을 성장시켰으며, ion-surface interaction 효과가 박막 성장주에 미치는 영향을 이해하기 위하여 먼저 반응성 산소 이온빔에 비 반응성 아르곤 이온빔을 다양하게 변화시켜가며 증착하였으며, 이와 더불어 산소 분위기에서 아르곤 이온빔에 의한 ITO 박막의 특성 변화를 각각 관찰하였다. 증착전 후의 열처리 없이 상온에서 비저항이 ~10-4$\Omega$cm 이하로 낮고 80% 이상의 투과율을 갖는 ITO 박막을 성장시켰다. 실험에서 이용된 e-beam evaporation 물질은 In2O3-SnO2(1-wt%)였으며, 이온빔 source는 산소에 의한 filament의 산화를 막기 위해 filament cathodes type이 아닌 rf(radio-frequency)를 사용하였다. 중요 증착변수인 이온빔의 flux 변화는 산소와 Ar의 flow rate를 MFC로 조절하고 rf power를 변화시켜 얻었으며, 이온빔 에너지는 가속 grid의 가속전압 변화와 ion gun과 기판사이의 거리 조절을 통해 최적화하였다. 이온빔의 에너지와 flux는 Faraday cup으로 측정하였으며, 성박된 박막의 특성은 UV-spectrometer, 4-point probe, Hall measurement. $\alpha$-step, XRD, XPS 등을 이용하여 광학적, 전기적, 구조적 특성을 분석하였다.

  • PDF

Weighted Averaged Flux Method for Computation of Shallow Water Equations (WAF 기법을 이용한 천수방정식 해석)

  • Kim, Woo-Gu;Jung, Kwan-Sue;Kim, Jae-Han
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.5
    • /
    • pp.777-785
    • /
    • 2003
  • A numerical model for the solution of two-dimensional free surface flow is developed on unstructured grid. By using fractional step method, the two-dimensional shallow water equations (SWE) are treated as two one-dimensional problems. Thus, it is possible to simulate computational hydraulic problems with higher computational efficiency. The one-dimensional problems are solved using upwind TVD version of second-order Weighted Averaged Flux (WAF) scheme with HLLC approximate Riemann solver. The numerical oscillations which are common with second-order numerical scheme are controlled by exploiting WAF flux limiter, Some idealized test problems are solved using this model and very accurate and stable solutions are obtained. It can be concluded as an efficient implement for the computation of SWE including dam break problems that concerning discontinuities, subcritical and supercritical flows and complex domain.

Numerical Simulation of Turbulent Heat Transfer in Locally-Forced Separated and Reattaching Flow (국소교란에 의한 박리 재부착 유동에서의 난류 열전달 수치해석)

  • Ri, Gwang-Hun;Seong, Hyeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.87-95
    • /
    • 2001
  • A numerical study was made of heat transfer in locally-forced turbulent separated and reattaching flow over a backward-facing step. The local forcing was given to the flow by means of sinusoidally oscillating jet from a separation line. A Rhee and Sung version of the unsteady $\kappa$-$\varepsilon$-f(sub)u model and the diffusivity tensor heat transfer model were employed. The Reynolds number was fixed at Re(sub)H=33,000 and the forcing frequency was varied in the range 0$\leq$fH/U(sub)$\infty$$\leq$2. The condition of constant heat flux was imposed at the bottom wall. The predicted results were compared and validated with the experimental data of Chun and Sung and Vogel and Eaton. The enhancement of heat transfer in turbulent separated and reattaching flow by local forcing was evaluated and analyzed.