• Title/Summary/Keyword: flux dam

Search Result 56, Processing Time 0.022 seconds

Characteristics of Sea Exchange in Gwangyang Bay and Jinju Bay considering Freshwater from Rivers (하천유출수를 고려한 광양만과 진주만의 해수교환 특성)

  • Hong, Doung;Kim, Jongkyu;Kwak, Inn-Sil
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.201-211
    • /
    • 2022
  • At the center of the Noryang waterway, the Gwangyang bay area (including the Yeosu Strait) is located at the west, and the Jinju bay area (including Gangjin bay and Sacheon bay) is located at the east. Freshwater from several rivers is flowing into the study area. In particula,r the event of flood, great quantities freshwater flow from Seomjingang (Seomjin river) into the Gwangyang bay area and from Gahwacheon (discharge from Namgang Dam) into the Jinju bay. The Gwangyang and Jinju bay are connected to the Noryang waterway. In addition, freshwater from Seomjingang and Gahwacheon also affect through the Noryang waterway. In this study, we elucidated the characteristics of the tidal exchange rate and residence time for dry season and flood season on 50 frequency, considering freshwater from 51 rivers, including Seomjingang and Gahwacheon, using a particle tracking method. We conducted additional experiments to determine the effect of freshwater from Seomjingang and Gahwacheon during flooding. In both the dry season and flood season, the result showed that the particles released from the Gwangyang bay moved to the Jinju bay through the Noryang waterway. However, comparatively small amount of particles moved from the Jinju bay to the Gwangyang bay. Each experimental case, the sea exchange rate was 44.40~67.21% in the Gwangyang bay and 50.37~73.10% in the Jinju bay, and the average residence time was 7.07~15.36days in the Gwangyang bay and 6.45~12.75days in the Jinju bay. Consequently the sea exchange rate increased and the residence time decreased during flooding. A calculation of cross-section water flux over 30 days for 7 internal and 5 external areas, indicated that the main essential flow direction of the water flux was the river outflow water from Seomjingang flow through the Yeosu strait to the outer sea and from Gahwacheon flow through Sacheon bay, Jinju bay and the Daebang waterway to the outer sea.

Handling Method for Flux and Source Terms using Unsplit Scheme (Unsplit 기법을 적용한 흐름율과 생성항의 처리기법)

  • Kim, Byung-Hyun;Han, Kun-Yeon;Kim, Ji-Sung
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.12
    • /
    • pp.1079-1089
    • /
    • 2009
  • The objective of this study is to develop the accurate, robust and high resolution two-dimensional numerical model that solves the computationally difficult hydraulic problems, including the wave front propagation over dry bed and abrupt change in bathymetry. The developed model in this study solves the conservative form of the two-dimensional shallow water equations using an unsplit finite volume scheme and HLLC approximate Riemann solvers to compute the interface fluxes. Bed-slope term is discretized by the divergence theorem in the framework of FVM for application of unsplit scheme. Accurate and stable SGM, in conjunction with the MUSCL which is second-order-accurate both in space and time, is adopted to balance with fluxes and source terms. The exact C-property is shown to be satisfied for balancing the fluxes and the source terms. Since the spurious oscillations in second-order schemes are inherent, an efficient slope limiting technique is used to supply TVD property. The accuracy, conservation property and application of developed model are verified by comparing numerical solution with analytical solution and experimental data through the simulations of one-dimensional dam break flow without bed slope, steady transcritical flow over a hump and two-dimensional dam break flow with a constriction.

Characterization of Membrane Fouling and It's Optimal Chemical Cleaning Method in MF Process using D dam water (D댐수를 이용한 정밀여과 공정에서 막오염 특성 및 최적 화학세정방법 조사)

  • Kim, Chung H.;Lim, Jae L.;Lee, Byung G.;Chae, Seon H.;Park, Min G.;Park, Sang H.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.559-569
    • /
    • 2007
  • The purposes of this study were to find the main foulant of membrane and the optimal chemical cleaning method for MF(microfiltration) drinking water treatment system using D dam water as water source. The MF pilot plant which can treat maximum $500m^3/d$ consisted of 3 racks and was operated for 10 months under various operation conditions. After 10 months operation, $1^{st}$ and $2^{nd}$ rack of membrane pilot plant system were cleaned chemically and the degree of the restoration of the fouled membrane in terms of the pure water flux was detemnined. Inorganic compounds which contained in chemical cleaning waste was analyzed by Inductively Coupled Plasma (ICP). One membrane module for 3rd rack was disjointed and membrane fouling materials, especially inorganic compounds were investigated by Electron Probe Microanlysis (EPMA) to elucidate the reason of TMP increase. And also, the various chemical reagents (1N HCl or $H_2SO_4$, oxalic acid as acid and 0.3% NaOCl as alkali) were tested by combination of acid and alkali to determine the optimal chemical cleaning method for the MF system using micro-modules manufactured using the disjointed module. It was verified that the inside and outside of membrane module was colorized with black. As a result of the quantitative and semi-qualitative analysis of membrane foulant by ICP, most of inorganic foulant was manganese which is hard to remove by inorganic acid such as HCI. Especially, it was observed by EPMA that Mn was attached more seriously in inside surface of membrane than in outside surface of that. It was supposed that Mn fouling in inside surface of membrane might be caused by the oxidation of soluble manganese (Mn(II)) to insoluble manganese ($MnO_2$) by chlorine containing in backwashing water. The optimal cleaning method for the removal of manganese fouling was consecutive cleaning with the mixture of 1N HCl and 1% of oxalic acid, 0.3% NaOCl, and 1N HCl showing 91% of the restoration of the fouled membrane.

A study on the selection of evapotranspiration observatory representative location in Chuncheon Dam basin (증발산량 관측 대표위치 선정에 관한 연구: 춘천댐 유역을 중심으로)

  • Park, Jaegon;Kim, Kiyoung;Lee, Yongjun;Hwag-Bo, Jong Gu
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.11
    • /
    • pp.979-989
    • /
    • 2022
  • In hydrological surveys, observation through representative location is essential due to temporal and spatial limitations and constraints. Regarding the use of hydrological data and the accuracy of the data, there are still insufficient observatories to be used in a specific watershed. In addition, since there is virtually no standard for the location of the current evapotranspiration, this study proposes a method for determining the location of the evapotranspiration. To determining the location of evapotranspiration, a grid is selected in consideration of the operating range of the Flux Tower using the eddy covariance measurement method, which is mainly used to measure evapotranspiration. The grid of representative location was calculated using the factors affecting evapotranspiration and satellite data of evapotranspiration. The grid of representative location was classified as good, fair, and poor. As a result, the number of good grids calculated was 54. It is judged that the classification of the grid has been achieved regarding topography and land use as a characteristic that appeared in the classification of the grid. In particular, in the case of elevation or city area, there was a large deviation, and the calculated good grid was judged to be a group between the two distributions.

Current status of site observations for evapotranspiration and soil moisture content in the K-water dam watershed (K-water 댐 유역 증발산량 및 토양수분량 관측 현황)

  • Cho, Younghyun;Kang, Tae Ho;Lee, Young Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.67-67
    • /
    • 2022
  • 국가 물관리 측면에서 증발산량과 토양수분량은 자연계 손실로서 국내 수자원 총량의 약43%(563억 m3/년)를 차지하며, 수자원의 계획과 개발, 물순환 과정 규명 및 다양한 수재해 분석 등을 위한 수문 요소이다. 정부는 2005년 「수문조사 선진화 5개년 계획」과 2008년 「제1차 수문조사기본계획(2010~2019년)」을 통해 2019년까지 증발산량과 토양수분량 관측소 확대(각각 25개 지점) 기반을 마련하였고 「수자원의 조사·계획 및 관리에 관한 법률」에 따라 매년 공인 수문 자료로 증발산량과 토양수분량을 측정하고 있다. 증발산량과 토양수분량은 댐 유역의 정밀한 물순환 해석에도 매우 중요한 정보로서 현재 K-water에서의 관측은 일부 시험유역(용담댐 유역)의 flux tower에 의한 에디공분산법(Eddy Covariance Method) 및 토양수분 센서(TDR, Time Domain Reflectometery)에 의한 지점 자료의 생산만 각각 이루어지고 있다. 본 연구에서는 K-water 댐 유역의 증발산량 및 토양수분량 관측 현황과 그간 관측된 자료의 특성을 각종 경향성 분석 등과 함께 소개하고자 한다, 증발산량의 경우는 2개소의 flux tower를운영(덕유산 지점 2011년 이후, 용담 지점 2017년 이후)하고 있으며, 토양수분량은 총 7개소(계북, 천천, 상전, 안천, 부귀, 주천 지점 2013년 이후, 장계 지점 2017년 이후)에 TDR센서를 설치, 계측 운영 중이다. 이렇게 관측된 자료는 매년 홍수통제소 주관 관련 전문가 공인심사를 통해 일자료 기준으로 한국수문조사연보에 수록되고 있으며, K-water에서도 연보를 통해 공개된 자료를 기준으로 공공데이터포털(data.go.kr) 등과 연계하여 온라인 자료 서비스 중이다. 한편, 최근 2020년 「제2차 수문조사 기본계획(2020~2029년)」에서는 수자원 위성 개발연구와 연계하여 위성을 활용한 증발산량과 토양수분량 산정 연구의 필요성이 강조되고 있다. 하지만 본 연구에서 살펴본 지점 자료만으로는 댐 유역을 포함한 광역단위의 시계열 공간정보를 생산하기 한계가 있으며, 댐 유역과 국내 전 지역의 공간 시계열 증발산량 및 토양수분량 자료 산정과 활용 방안에 대해 정립하고, 나아가 위성영상을 활용한 댐 유역 증발산량·토양수분량 관측 가이드라인 마련 등을 위해서는 국가적으로 많은 재원의 투입과 노력이 필요한 상황이다.

  • PDF

Micropropagation of Sweetpotato (Ipomoea batatas) in a novel $CO_2$-Enriched Vessel

  • Silva Jaime A. Teixeira da;Giang Dam Thi Thanh;Tanaka Michio
    • Journal of Plant Biotechnology
    • /
    • v.7 no.1
    • /
    • pp.67-74
    • /
    • 2005
  • To overcome various disadvantages of conventional cul-ture vessels for micropropagation, a novel disposable vessel, the 'Vitron', made of a multi-layered $OTP^{(R)}$ film and supported by a polypropylene frame, was developed. The film possesses superior properties such as: high light transmittance, low water vapor transmittance and thermal stability and in particular, high gas-permeability. Single nodal explants, which were excised from the multiple shoots derived from shoot-tip culture, were cultured in Vitron and polycarbonate vessels on $3\%$ sugar-containing agar on MS medium and placed at 3000 ppm $CO_2$-enrichment at a low photosynthetic photon flux density (PPFD) ($45{\mu}mol\;m^{-2}\;s^{-1}$). The in vitro and ex vitro growth, and the net photosynthetic rate of in vitro and ex vitro plantlets were significantly enhanced in the Vitron compared to those cultured in a polycarbonate vessel. Explants that were cultured on the same MS medium under low PPFD at various $CO_2$ concentrations were also cultured at 3000 ppm $CO_2$- enrichment at various PPFD: 30, 45, 60, 75 and $90{\mu}mol\;m^{-2}\;s^{-1}$. The best in vitro and ex vitro growth obtained for 3000 ppm $CO_2$-enrichment at $75{\mu}mol\;m^{-2}\;s^{-1}$ PPFD. The novel Vitron vessel, when placed under the two conditions, may replace conventional culture vessels for the successful micropropagation of sweetpotato.

A New VOF-based Numerical Scheme for the Simulation of Fluid Flow with Free Surface(I)-New Free Surface Tracking Algorithm and Its Verification- (자유 표면이 존재하는 유체 유동 해석을 위한 VOF방법의 기반의 새로운 수치 기법(I)-새로운 자유 표면 추적 알고리즘 및 검증-)

  • Kim, Min-Su;Sin, Su-Ho;Lee, U-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.12
    • /
    • pp.1555-1569
    • /
    • 2000
  • Numerical simulation of fluid flow with moving free surface has been carried out. For the free surface flow, a VOF(Volume of Fluid)-based algorithm utilizing a fixed grid system has been investigated. In order to reduce numerical smearing at the free surface represented on a fixed grid system, a new free surface tracking algorithm based on the donor-acceptor scheme has been presented. Novel features of the proposed algorithm are characterized as two numerical tools; the orientation vector to represent the free surface orientation in each cell and the baby-cell to determine the fluid volume flux at each cell boundary. The proposed algorithm can be easily implemented in any irregular non-uniform grid systems that are usual in finite element method (FEM). Moreover, the proposed algorithm can be extended and applied to the 3-D free surface flow problem without additional efforts. For computation of unsteady incompressible flow, a finite element approximation based on the explicit fractional step method has been adopted. In addition, the SUPG(streamline upwind/Petrov-Galerkin) method has been implemented to deal with convection dominated flows. Combination of the proposed free surface tracking scheme and explicit fractional step formulation resulted in an efficient solution algorithm. Validity of the present solution algorithm was demonstrated from its application to the broken dam and the solitary wave propagation problems.

Simulations of Thermal Stratification of Daecheong Reservoir using Three-dimensional ELCOM Model (3차원 ELCOM 모형을 이용한 대청호 수온성층 모의)

  • Chung, Se Woong;Lee, Heung Soo;Choi, Jung Kyu;Ryu, In Gu
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.922-934
    • /
    • 2009
  • The transport of contaminants and spatial variation in a deep reservoir are certainly governed by the thermal structure of the reservoir. There has been continuous efforts to utilize three-dimensional (3D) hydrodynamic and water quality models for supporting reservoir management, but the efforts to validate the models performance using extensive field data were rare. The study was aimed to evaluate a 3D hydrodynamic model, ELCOM, in Daecheong Reservoir for simulating heat fluxes and stratification processes under hydrological years of 2001, 2006, 2008, and to assess the impact of internal wave on the reservoir mixing. The model showed satisfactory performance in simulating the water temperature profiles: the absolute mean errors at R3 (Hoenam) and R4 (Dam) sites were in the range of $1.38{\sim}1.682^{\circ}C$. The evaporative and sensible heat losses through the reservoir surface were maximum during August and January, respectively. The net heat flux ($H_n$) was positive from February to September, while the stratification formed from May and continued until September. Instant vertical mixing was observed in the reservoir during strong wind events at R4, and the model reasonably reproduced the mixing events. A digital low-pass filter and zero crossing method was used to evaluate the potential impact of wind-driven internal wave on the reservoir mixing. The results indicated that most of the wind events occurred in 2001, 2006, 2008 were not enough to develop persistent internal wave and effective mixing in the reservoir. ELCOM is a suitable 3D model for supporting water quality management of the deep and stratified reservoirs.

OPTIMUM STORAGE REALLOCATION AND GATE OPERATION IN MULTIPURPOSE RESERVOIRS

  • Hamid Moradkhani
    • Water Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.57-62
    • /
    • 2002
  • This research is intended to integrate long-term operation rules and real time operation policy for conservation & flood control in a reservoir. The familiar Yield model has been modified and used to provide long-term rule curves. The model employs linear programming technique under given physical conditions, i.e., total capacity, dead storage, spillways, outlet capacity and their respective elevations to find required and desired minimum storage fur different demands. To investigate the system behavior resulting from the above-mentioned operating policy, i.e., the rule curves, the simulation model was used. Results of the simulation model show that the results of the optimization model are indeed valid. After confirmation of the above mentioned rule curves by the simulation models, gate operation procedure was merged with the long term operation rules to determine the optimum reservoir operating policy. In the gate operation procedure, operating policy in downstream flood plain, i.e., determination of damaging and non-damaging discharges in flood plain, peak floods, which could be routed by reservoir, are determined. Also outflow hydrograph and variations of water surface levels for two known hydrographs are determined. To examine efficiency of the above-mentioned models and their ability in determining the optimum operation policy, Esteghlal reservoir in Iran was analyzed as a case study. A numerical model fur the solution of two-dimensional dam break problems using fractional step method is developed on unstructured grid. The model is based on second-order Weighted Averaged Flux(WAF) scheme with HLLC approximate Riemann solver. To control the nonphysical oscillations associated with second-order accuracy, TVD scheme with SUPERBEE limiter is used. The developed model is verified by comparing the computational solutions with analytic solutions in idealized test cases. Very good agreements have been achieved in the verifications.

  • PDF

Evapotranspiration Estimation by The Eddy-Covariance in The Yongdam Dam Experimental Basin (에디공분산 관측시스템을 이용한 용담댐 시험유역 증발산량 산정연구)

  • Kim, Yong-Kuk;Lee, Hyun-Seok;Chae, Hyo-Seok;Kim, Young-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.274-274
    • /
    • 2012
  • 증발산량 관측은 오랜 기간 연구되어 왔으며, 미기상 관측 시스템의 최적화와 상호 공동비교 실험 및 자료 처리의 일관성을 유지를 위해 한국에는 KoFlux라고 하는 플럭스 네트워크가 2002년 1월에 구축되었다. 이를 시작으로 미기상 관측에 대한 관심이 많은 연구자들이 관측망 구축에 힘쓰고 있으며, 에디공분산 방법을 이용해 증발산량을 산정하고 있다. 에디 공분산 방법은 다른 방법에 비해 연직농도 차이가 적은 산림 위에서의 플럭스 값을 측정 할 수 있으며, 측정 시 식물 환경에 방해를 주지 않는 등의 장점이 있다. 하지만 자료 처리와 품질관리에 있어 연구자의 주관성에 의해 상당 부분 불확실성을 초래한다. 또한 다른 관측지점과의 일관적인 비교를 위해 좌표보정을 수행하며, 일반적으로 바람이 평평한 지역 위로 분다는 가정 하에 이루어진다. 좌표보정은 일반적으로 Planar Fit Rotation방법을 사용하며, 평판 분할은 지형에 따라 12개까지 분할하여 분석한다. 하지만 덕유산 플럭스관측 타워지점처럼 산지 특성이 뚜렷하고 1 m/s이하의 풍속 데이터의 빈도가 큰 경우 평판 분할 수의 제한이 발생한다. 이러한 문제를 해결하기 위해 좌표보정계수산정 방법에 따라 등간격의 평판분할 방법(Scenario A), 주풍향을 고려한 평판분할 방법(Scenario B)과 빈도에 의한 평판분할방법(Scenario C)으로 수행하였다. 또한 각 Scenario는 풍속의 제한 조건에 따라 CASE A(0.5 m/s 이상), CASE B(1.0 m/s이상)로 구분하여 분석하였다. 본 연구를 통해 제안 한 자료처리 절차는 첫째, 바람자료의 빈도 분석을 통한 지역특성 파악 둘째, 풍속제한 조건 설정 셋째, 바람과 수증기의 공분산 계산으로 요약된다. 덕유산 플럭스관측 타워지점의 경우 풍속 제한을 1.0 m/s이상에서 0.5 m/s이상으로 하향 조정하였으며, 평판 분할 방법은 Scenario C의 평판 수 12개를 채택하였다.

  • PDF