• Title/Summary/Keyword: flux angle

Search Result 508, Processing Time 0.033 seconds

A Study on the Performance of Waterjet Propulsion System for Small Naval Ship (소형 Waterjet 추진성능 검증에 관한 연구)

  • Kim, Kyoung-Bae;Cho, Dong-Joo;Park, Myung-Ku
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.6
    • /
    • pp.787-791
    • /
    • 2010
  • This paper describes the performance of small waterjet propulsion system and show the influence of performance for nozzle shape and area. The installed engine sets a limit on maximum power in below 1800 rpm for fuel saving. Our designated target is reached by redesign of the impeller considering engine characteristics and extention of nozzle pararell part. The results of the full-scale ships are compared with thoes of the model test. In the future, those experimental data will be applied to the relation study between engine characteristics and powering performance prediction.

Position Detection of a Capsule-type Endoscope by Magnetic Field Sensors (자계 센서를 이용한 캡슐형 내시경의 위치 측정)

  • Park, Joon-Byung;Kang, Heon;Hong, Yeh-Sun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.6
    • /
    • pp.66-71
    • /
    • 2007
  • Development of a locomotive mechanism for the capsule type endoscopes will largely enhance their ability to diagnose disease of digestive organs. As a part of it, there should be provided a detection device of their position in human organs for the purpose of observation and motion control. In this paper, a permanent magnet outside human body was employed to project magnetic field on a capsule type endoscope, while its position dependent flux density was measured by three hall-effect sensors which were orthogonally installed inside the capsule. In order to detect the 2-D position data of the capsule with three hall-effect sensors including the roll, pitch and yaw angle, the permanent magnet was extra translated during the measurement. In this way, the 2-D coordinates and three rotation angles of a capsule endoscope on the same motion plane with the permanent magnet could be detected. The working principle and performance test results of the capsule position detection device were introduced in this paper showing that they could be also applied to 6-DOF position detection.

An Encoder Fault Detection Scheme using Parity Equation for Vector Controlled Induction Motor Drives (벡터제어 유도전동기 구동장치를 위한 패리티 관계식을 이용한 엔코더 고장검출 기법)

  • Park, Tae-Geon;Ryu, Ji-Su;Lee, Kee-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2014-2017
    • /
    • 2001
  • In induction motor control systems driven by the indirect vector control scheme, the errorneous measurement of rotor speed results in incorrect flux angle estimate and consequently deteriorates the overall control performance. In this paper the effect of encoder fault on motor variables and control performance is analyzed by both theoretical approach and experimental study. A parity equation based on the power is suggested and applied to detect the incipient fault of encoder.

  • PDF

LED module for a desk lamp (탁상 스탠드용 LED모듈)

  • Kang, Seok-Hoon;Shin, Kyung-Ho;Yeo, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1713-1715
    • /
    • 2003
  • This paper describes an LED module for a desk lamp using 1[W] high flux while LEDs. The optimum length of the module is obtained from the lighting simulation of the target area of $500{\times}500[mm]$ on the desk, which in turn determines an optimum separation between LEDs. The main issue is to find the optimum separation which gives good illuminance uniformity and high coefficient of utilization at at various reflector structures. Two module configuations of linear and ring types are compared. As a result, good illuminance uniformity is obtained in the case of the ring module. The mofied twin type, however, gives better performance than the ring module, and shows the most performance at an separation angle of around $30^{\circ}$.

  • PDF

Effect of Mutual Coupling Between Test Leads on Ground Impedance Measurement (측정선의 상호유도작용이 접지임피던스의 측정에 미치는 영향)

  • Lee, Bok-Hee;Eom, Ju-Hong;Cho, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.71-74
    • /
    • 2003
  • Fall-of-potential method is used usually to measure the ground impedance of large scale grounding system exactly. Because the interlinked magnetic flux between closed loops to inject test current and to measure potential rise is existed in E-P-C straight line arrangement, mutual(or inductive) coupling influences greatly on the measurement correctness. Measurement errors produced from inductive coupling could be reduced by the arrangement methods of auxiliary electrodes. Right angle or P-E-C order arrangement methods were effective to reduce the inductive coupling and the decrease degree of measurement error was analysed as quantitative through an experiment.

  • PDF

Optimal Excitation Angles of a Switched Reluctance Generator for Maximum Output Power

  • Thongprasri, Pairote;Kittiratsatcha, Supat
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1527-1536
    • /
    • 2014
  • This paper investigates the optimal values of turn-on and turn-off angles, and ratio of flux linkage at turn-off angle and peak phase current positions of optimal control for accomplishing maximum output power in an 8/6 Switched Reluctance Generator (8/6 SRG). Phase current waveform is analyzed to determine optimal excitation angles (optimal turn-on and turn-off angles) of the SRG for maximum output power which is applied from a nonlinear magnetization curve in terms of control variables (dc bus voltage, shaft speed, and excitation angles). The optimal excitation angles in single pulse mode of operation are proposed via the analytical model. Simulated and experimental results have verified the accuracy of the analytical model.

Numerical Simulation of Bubble Motion During Nucleate Boiling (핵비등에서의 기포거동에 관한 수치해석)

    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.3
    • /
    • pp.389-396
    • /
    • 2001
  • Direct numerical simulation of bubble growth and merger process on a single nucleation site during partial nucleate boiling is performed. The equations governing conservation of mass, momentum and energy are solved using a finite difference method combined with a level set method for capturing the vapor-liquid interface. The level set method is modified to include the effects of phase change at the interface and contact angle at the wall. Also, a simplified formulation for predicting the evaporative heat flux in a thin liquid micro-layer is developed and incorporated into the level set formulation. Based on the numerical results, the bubble growth and merger pattern and its effect on the heat transfer are discussed.

Wettability Evaluation by Wetting Balance Test and Wetting Characteristics of Solders (웨팅밸런스법을 통한 젖음성 평가와 솔더의 젖음 특성)

  • Jeon, Wook Sang;Rajendran, Sri Harini;Jung, Jae Pil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.3
    • /
    • pp.1-6
    • /
    • 2019
  • Wettability is an important factor to decide solderability of solder, flux, other soldering-related materials and soldering conditions. The wettability also affects the reliability of solder joint. Wetting balance test is a good method for quantitatively measuring wettability between solder and substrate. The wetting balance test is easy to reproduce the wetting experiment and to measure the wetting time and force. And this test provides wetting curve to calculate the surface tension of the molten solder. Development of new solder has been continued in accordance with various and harsh environment in the electronics industry. In this paper, the principle of wetting balance test and recent research issues including nano-composite solder are explained.

Evaluation of Condensation Heat Transfer Correlations for Microfin Tubes

  • Han, Dong-Hyouck;Lee, Kyu-Jung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.4
    • /
    • pp.163-168
    • /
    • 2007
  • The feature of six existing condensation heat transfer correlations for microfin tubes were evaluated with the consideration of vapor quality, mass flux, geometries, and various refrigerants. The Kosky and Staub [15] and the Jaster and Kosky [16] correlations for smooth tube were used for the evaluation of the heat transfer enhancement factor (EF). For the prediction of zeotropic mixtures, most correlations show discrepancy with previous measurements. The Yu and Koyama [4] and the Shikazono et al. [8] correlations do not consider spiral angle effect. The Han and Lee [10] correlation shows fin height growth deteriorates heat transfer. Experimental verification to develop reliable condensation heat transfer correlation for microfin tubes is still needed with the consideration of geometrical effects and working conditions.

Fouling resistant membrane tailored by polyethylene glycol in oxidative environment for desalination

  • Kavaiya, Ashish R.;Raval, Hiren D.
    • Membrane and Water Treatment
    • /
    • v.10 no.5
    • /
    • pp.381-385
    • /
    • 2019
  • Surface modification is very efficient and scalable approach to achieve improved membrane performance. We treated Reverse Osmosis Thin Film Composite (TFC RO) membrane with various concentrations of Polyethylene Glycol (PEG), a hydrophilic polymer after activation with sodium hypochlorite. This treatment resulted in an increment of the water flux by 43% and the salt rejection by 2.36% for the 3000 mg/l PEG-treated membrane. Further, these PEG-treated membranes were exposed to a mixture of 3000 mg/l PEG and 1000 mg/l sodium hypochlorite for 1 hour. Further modification of this membrane by PEG and sodium hypochlorite mixture increased the water permeance up to 133% when compared with the virgin TFC RO membrane. We characterized the treated membranes to understand the changes in wettability by contact angle analysis, changes in surface morphology and roughness by scanning electron microscope (SEM) and atomic force microscope (AFM) analysis.