• Title/Summary/Keyword: fluorine

Search Result 787, Processing Time 0.027 seconds

Properties of fluorine-doped $SnO_2$ films prepared by the ultrasonic spray deposition (초음파분무법에 의해 제작된 $SnO_2(:F)$ 박막의 특성)

  • Byung Seok Yu;Sei Woong Yoo;Jeong Hoon Lee
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.4 no.3
    • /
    • pp.294-305
    • /
    • 1994
  • The influence of deposition parameter on the electrical, optical andsurface morphology of $SnO_2(:F)$ films prepared by ultrasonic spray deposition using DBDA and $SnCl_4.5H_2O$ as a source material was studied. Resistivity was decreased sharply with increasing F/Sn ratio in solution up to 0.6. Depending on the source material, $SnCl_4.5H_2O$ shows lower resistivity than DBDA. When F/Sn ratio in solution was 1, optical transmittance was higher DBDA than $SnCl_4.5H_2O$.

  • PDF

X-ray Photoelectron Spectroscopic Analysis of Modified MWCNT and Dynamic Mechanical Properties of E-beam Cured Epoxy Resins with the MWCNT

  • Lee, Young-Seak;Im, Ji-Sun;Yun, Seok-Min;Nho, Young-Chang;Kang, Phil-Hyun;Jin, Hang-Kyo
    • Carbon letters
    • /
    • v.10 no.4
    • /
    • pp.314-319
    • /
    • 2009
  • The surface treatment effects of reinforcement filler were investigated based on the dynamic mechanical properties of mutiwalled carbon nanotubes (MWCNTs)/epoxy composites. The as-received MWCNTs(R-MWCNTs) were chemically modified by direct oxyfluorination method to improve the dispersibility and adhesiveness with epoxy resins in composite system. In order to investigate the induced functional groups on MWCNTs during oxyfluorination, X-ray photoelectron spectroscopy was used. The thermo-mechanical property of MWCNTs/epoxy composite was also measured based on effects of oxyfluorination treatment of MWCNTs. The storage modulus of MWCNTs/epoxy composite was enhanced about 1.27 times through oxyfluorination of MWCNTs fillers at $25^{\circ}C$. The storage modulus of oxyfluorinated MWCNTs (OF73-MWCNTs) reinforced epoxy composite was much higher than that of R-MWCNTs/epoxy composite. It revealed that oxygen content led to the efficient carbon-fluorine covalent bonding during oxyfluorination. These functional groups on surface modified MWCNTs induced by oxyfluorination strikingly made an important role for the reinforced epoxy composite.

Optimization of Electrical/Optical Properties of ITO/Al Based Reflector for Vertical-type UV LEDs via SF6 Plasma Treatments (불소계열 플라즈마 처리를 통한 수직형 UV LED용 ITO/Al 기반 반사전극의 전기적/광학적 특성 최적화)

  • Shin, Ki-Seob;Kim, Dong-Yoon;Kim, Tae-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.11
    • /
    • pp.911-914
    • /
    • 2011
  • We optimize electrical and optical properties of thermal and SF6 plasma treated indium tin oxide (ITO)/Al based reflector for high-power ultraviolet (UV) light-emitting diodes (LEDs). After thermal and $SF_6$ plasma treatments of ITO/Al reflector, the specific contact resistance decreased from $1.04{\times}10^{-3}\;{\Omega}{\cdot}cm^2$ to $9.21{\times}10^{-4}\;{\Omega}{\cdot}cm^2$, while the reflectance increased from 58% to 70% at the 365 nm wavelength. The low resistance and high reflectance of ITO/Al reflector are attributed to the reduced Schottky barrier height (SBH) between the ITO and AlGaN by large electronegativity of fluorine species and reduced interface roughness between the ITO and Al, respectively.

DIAGNOSTIC ACCURACY OF $^{18}F$-FDG IN NODAL NEGATIVE ORAL SQUAMOUS CELL CARCINOMA (구강암 환자에서 경부 임파절 평가에 대한 $^{18}F$-FDG PET(Fluorine 18-Labelled Deoxyglucose Positron Emission Tomography)의 유용성)

  • Choi, Eun-Joo;Kang, Sang-Hoon;Kim, Ki-Ho;Nam, Woong;Kim, Hyung-Jun;Cha, In-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.6
    • /
    • pp.597-600
    • /
    • 2007
  • PET is one of the most widely used verification methods for evaluation of metastasis on the lymph nodes of the neck in oral cancer patients. The purpose of this study was to assess the correlation between PET findings and histopathologic findings in patients who had been diagnosed as squamous cell carcinoma and performed neck dissection. Thirty-four necks in 25 patients had been evaluated on pathologic lymph nodes and the data were compared with preoperative PET scan. The sensitivity of PET at the level of the neck was 72.7%, specificity was 60%, and accuracy was 79.2%. Since FDG-PET show high false-positive results, it should be used with other diagnostic tools for evaluation of lymph node metastasis.

Role of PET Scan in Gastric Cancer as a Diagnostic Tool (위암에시 PET의 임상적 역할)

  • Cheon, Gi-Jeong;Kim, Byung-Il;Lim, Sang-Moo
    • 대한위암학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.24-33
    • /
    • 2002
  • Clinical application of positron emission tomography (PET) is rapidly increasing for the detection and staging of cancer at whole-body studies performed with the glucose analogue tracer 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FDG). Although FDG PET cannot match the anatomic resolution of conventional imaging techniques in gastrointestinal and abdominal organs, it is particularly useful for identification and characterization of whole body at the same time. FDG PET can show foci of metastatic disease that may not be apparent at conventional anatomic imaging and can aid in the characterization of indeterminate soft-tissue masses. Most gastrointestinal cancer need to surgical management. FDG PET can improve the selection of patients for surgical treatment and thereby reduce the morbidity and mortality associated with inappropriate surgery. FDG PET is also useful for the early detection of recurrence and the monitoring of therapeutic effect. The gastrointestinal cancers, such as gastroeso-phageal cancer, colorectal cancer, liver cancer and pancreatic cancer, are common malignancies in Korea. PET is one of the most promising and useful methodology for the management of gastric cancer as well as other gastrointestinal cancers.

  • PDF

Electrochemical Evaluation on Corrosion Resistance of Anti-corrosive Paints

  • Moon, Kyung-Man;Lee, Myung-Hoon;Kim, Yun-Hae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.387-394
    • /
    • 2009
  • It has been observed that coated steel structures are rapidly deteriorated than designed lifetime due to acid rain caused by air pollution etc.. Therefore improvement of corrosion resistance of anti-corrosive paint is very important in terms of safety and economic point of view. In this study corrosion resistance for five kinds of anti-corrosive paints including acryl, fluorine and epoxy resin series were investigated with electrochemical methods such as corrosion potential, polarization curves, impedance and cyclic voltammogram measurements etc.. There were somewhat good relationships between values measured by electrochemical methods such as corrosion current density obtained by cathodic and anodic polarization curves, value of impedance estimated with AC impedance, and polarization resistance on the cyclic voltammogram, for example, corrosion current density was decreased with increasing of values of impedance and polarization resistance on the cyclic voltammogram. However their relationships between corrosion current density and corrosion potential were not well coincided each other. Consequently it is considered that although a corrosion potential of F101 of fuoric resin series shifted to negative direction than other anti-corrosive paints, its corrosion resistance, indicating on the cathodic and anodic polarization curves, AC impedance curves and cyclic voltammogram, was the most superior to other paints, whereas A100 containing arcylic resin showed a relatively poor corrosion resistance compared to other paints.

Standardized Uptake Values Highly Correlate with Tumor Size and Fuhrman Grade in Patients with Clear Cell Renal Cell Carcinoma

  • Polat, Emre Can;Otunctemur, Alper;Ozbek, Emin;Besiroglu, Huseyin;Dursun, Murat;Ozer, Kutan;Horsanali, Mustafa Ozan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7821-7824
    • /
    • 2014
  • Background: We investigated the correlation between standardized uptake value (SUVmax), tumor size and Fuhrman grade in patients with renal cell carcinoma (RC). Materials and Methods: We retrospectively analyzed the data of 54 patients with clear cell renal cell carcinoma histopathologically diagnosed who underwent fluorine-18 fluoro-2 deoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) between January 2005 and March 2014. Results: Avarage tumor sizes were $5.64{\pm}1.85$, $6.85{\pm}2.24$ and $7.98{\pm}2.45$ in low, medium and high SUVmax groups, respectively. The Spearman's correlation coefficient between the tumor size and SUVmax was 0.385 (p=0.004) and between the Fuhrman grade and SUVmax was 0.578 (p<0.001). Conclusions: SUVmax appears highly correlated with tumor size and Fuhrman grade in patients with histopathologically confirmed clear cell RC. Multicenter studies are needed to provide larger series for more accurate results.

Characteristics of Cr(III)-based Conversion Coating Solution to Apply Aluminum Alloys for Improving Anti-corrosion Properties

  • Shim, Byeong Yun;Kim, Hanul;Han, Chang Nam;Jang, Young Bae;Yun, Jeong Woo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.79-85
    • /
    • 2016
  • It is imperative to find environment-friendly coatings as an alternative to the currently used hexavalent chromate conversion coatings for the purpose of improving the anti-corrosion properties of aluminum alloys. Hence, in this study, the corrosion properties of a trivalent chromate conversion coating solution are analyzed and measured. Because of the presence of multiple components in trivalent chromate conversion coating solutions, it is difficult to control plating, attributed to their mutual organic relationship. It is of significance to determine the concentrations of the components present in these coatings; hence, qualitative and quantitative analysis is required. The coating solution contained not only an environment-friendly component chromium(III), but also zirconium, fluorine, sulfur, and potassium, in the coating film. These metals are confirmed to produce a film with improved corrosion resistance to form a thin layer. The excellent corrosion resistance for the trivalent chromate solution is attributed to various inorganic and organic additives.

Study on Toothbrushing Habits, Snack Intake Frequency, and Dental Caries in Primary School Students in Changwon City (창원지역 초등학생의 양치습관, 간식섭취빈도 및 충치실태)

  • Lee, Mee-Hoee;Youn, Hyun-Sook
    • Journal of the Korean Dietetic Association
    • /
    • v.17 no.4
    • /
    • pp.364-377
    • /
    • 2011
  • This study was conducted to provide basic information on toothbrushing habits, snack intake frequency, and current dental caries in elementary school students. A total of 188 students (105 boys and 83 girls) in Changwon city participated in this study. Dental examination was conducted by two dental hygienists in July, 2010. The results were as follows. Exactly 86.2% of students were shown to have dental caries, which includes a sealant and removed teeth due to decay. The average number of teeth with dental caries per student was 3.8. Exactly 60.6% of students were shown to maintain correct toothbrushing habits to prevent dental caries, but only 12.8% brushed their teeth immediately after a meal or snack. Exactly 82.4% percent of participants received toothbrushing education, 47.1% of them received it from an expert, 43.9% received from their parents, and 28.2% used tooth paste with fluorine. Regarding snack intake frequency, ice cream was the most consumed cariogenic food and white milk was the most consumed protective food. The >=7 teeth with dental caries group consumed higher frequency of carbonated beverages intake than the 'no dental caries' group (P<0.05), and the '5~6 teeth with dental caries' group consumed higher frequency of chocolate intake than 'no dental caries' group (P<0.05).

A Case of Chemical Burn Caused by Trifluoroacetic Anhydride that Mimicked a Hydrofluoric Acid Burn (불화수소산에 의한 것으로 오인된 Trifluoroacetic anhydride에 의한 화학화상)

  • Park, Jung-Soo;Kim, Hoon;Lee, Suk-Woo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.8 no.1
    • /
    • pp.43-45
    • /
    • 2010
  • A 22-year-old woman was referred to our emergency department for the treatment of a chemical injury on her arm. She had accidentally spilled 99% trifluoroacetic anhydride (TFAA) over her left forearm during an organic chemistry experiment. She visited a primary care unit, and then she was referred to our hospital for inactivation of the released fluoride ions. Her skin lesions were different from those caused by hydrofluoric acid (HF) injury. The injured area showed painful whitish maculae and patchy areas with accentuated rim. No vesiculation and bulla formation was detected. We intradermally injected a 5% solution of calcium through a 24-gauge needle into the burned skin. After the injection, she complained of more severe pain. Although TFAA contains fluorine, it does not release free fluoride ions on contact with the skin, unlike HF. In fact, application of calcium gluconate for TFAA burns is not recommended. Rather, it should be avoided since it increases pain and local abscess formation.

  • PDF