• Title/Summary/Keyword: fluoride removal

Search Result 96, Processing Time 0.023 seconds

Assessment of Field Application of Contaminated Sediment Removal Efficiency Using PVDF Combined Hybrid Tunnel Drainage (PVDF(Polyvinylidene Fluoride) 필름형 트랜스듀서 하이브리드 터널배수재에 대한 오염퇴적물 제거효율의 현장 적용성 평가)

  • Xin, Zhen-Hua;Moon, Jun-Ho;Kim, Young-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.513-519
    • /
    • 2019
  • Typically, contaminated sediments cause clogging of the drain pipe, which increases the residual water pressure in the drain pipe; this study constructed a system for improving drainage efficiency of tunnels by reducing physical and chemical obstructions through ultrasonic energy generated by a PVDF film. The developed hybrid drainage system utilized a PVDF material film fused with an existing drainage tunnel and maintenance system resulting in the ability to initialize the reverse piezoelectric effect, which was evaluated through an on site application. In order to investigate the maintenance performance of the tunnel drainage system, contaminated sediments were simulated in a drainage pipe to test the effect of ultrasonic conditions on drainage efficiency in the laboratory. As a result of applying the developed portable equipment, the ultrasonic energy was generated for about 20 minutes resulting in a reduction of 74.62% of the contaminated sediments and improving drainage efficiency. From the tunnel, acoustic pressure measurements were taken to calculate the response rate while taking into account the laboratory results. In addition, PVDF film was attached to the transverse and longitudinal side of the drainage pipes where contaminated sediments occur most often in the field tunnel. these calculations show contaminant removal was 90% effective.

Effects of chewable tablet containing sodium fluoride and xylitol on the oral hygiene state in the orthodontic patients (자일리톨과 불화나트륨을 함유한 저작성 정제가 교정환자의 구강위생에 미치는 영향에 관한 임상시험)

  • Yu, Sang-Hoon;Ahn, Sug-Joon;Lee, Shin-Jae;Baek, Seung-Hak;Kim, Tae-Woo;Chang, Young-Il;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.113-120
    • /
    • 2003
  • The aim of this study was to evaluate the effect a chewable tablet containing sodium fluoride and xylitol (DenPo, Hamizzle, Bucheon, Kyungki) on the oral hygiene state in the orthodontic patients.'rho subjects consisted of 30 adult orthodontic patients, who have worn the fixed orthodontic appliance at least 6 months. They were instructed to use the tablet forth a day, Gingival index (GI), plaque index (PI), and sulcus bleeding index (SBI) of upper and lower anterior and posterior regions were measured before using the tablet (T0), 2 weeks after using the tablet (T1), and 4 weeks after using the tablet (T2). The data were analyzed with Wilcoxon signed ranks tests. The results were as follows ; 1 PI was decreased significantly in the T1 and T2 stage compared with T0 stage in the both anterior and posterior regions (p<0.05). Although PI was decreased in the T2 stare compared with T1, there was not statistical significance (p>0.05). 2. GI and SBI showed similar results compared with PI. In the T1 and T2 stage, there was statistically significant decrease in the GI and SBI (p<0.05), This study showed that the DenPo tablet could be used as an adjunct to improve oral hygiene in the orthodontic patients. The decrease of the indices nay suggest that DenPo tablet could be effective in the plaque removal and prevention of gngival inflammation in the orthodontic patients.

A Study on Development of Alternative Non-aqueous Cleaning Agents to Ozone Depletion Substances and its Field Application (오존파괴물질 대체 비수계세정제 개발 및 현장 적용 연구)

  • Park, Yong-Bae;Bae, Jae-Heum;Lee, Min-Jae;Lee, Jong-Gi;Lee, Ho-Yeoul;Bae, Soo-Jung;Lee, Dong-Kee
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.306-313
    • /
    • 2011
  • Flux or solder is used in soldering process for manufacturing electronic parts such as printed circuit boards (PCB). After soldering process, residual flux and solder paste on the parts should be removed since their residuals could cause performance degradation or failure of parts due to their corrosion and electric leakage. Ozone depletion substances such as 1,1,1- trichloroethane (TCE) and HCFC-141b have widely been using for removal of residual flux and solder paste after soldering process In manufacturing of electronic parts until now. In this study, non-aqueous cleaning agents without flash point were developed and applied to industrial field for replacement of cleaning agents with ozone depletion. In order to develop non-aqueous cleaning agents without ethers, esters, fluoride- type solvents. And their physical properties and cleaning abilities were evaluated, and they were applied to industrial fields for cleaning of flux and solder on the PCB. And vacuum distillation apparatus were operated to determine their operating conditions and recycling yields for recycling of used cleaning agents formulated in this study. As a result of physical properties measurement of our formulated cleaning agents, they were expected to have good wetting and penetrating power since their surface tensions were relatively low as 18.0~20.4 dyne/$cm^2$ and their wetting indices are relatively large. And some cleaning agents holding fluoride-type solvents as their components did not have any flash point and they seemed to be safe in their handling and storage. The cleaning experimental results showed that some cleaning agents were better in their cleaning of flux and solder paste than 1,1,1-TCE and HCFC-141b. And industrial application results of the formulated cleaning agents for cleaning PCB indicated that they can be applicable to industry due to their good cleaning capability in comparison with HCFC-141b. The recycling experiments of the used formulated cleaning agents through a vacuum distillation apparatus also showed that their 91.9~97.5% could be recycled with its proper operating conditions.

Fluoride and nitrate removal by electro-coagulation for decentralized water treatment plants (전기응집을 이용한 소규모 수도시설의 불소 및 질산성질소 이온의 제거)

  • Han, Song-Hee;Chang, In-Soung;Back, Soun-Ok;Joung, Seun-Young;Lee, Cheol-Ku
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.115-116
    • /
    • 2010
  • 광역상수도의 경우 수자원공사 및 지방상수도 사업자들에 의해 전문적으로 수질을 관리하고 음용수를 보급하고 있으나 소규모 수도시설의 경우 전문능력을 갖춘 관리자가 아닌 마을의 대표자가 맡아 관리함에 따라 안정성 및 유지관리의 어려움이 자주 제기되고 있다.[1] 또한 소규모 수도시설의 경우 취수원으로 지하수나 계곡수를 이용하여 여과나 염소소독을 거쳐 음용수로 이용함에 따라 중금속 및 무기이온 등 각종 오염물질이 효과적으로 제거되지 않아 이를 사용하는 주민들이 불편함을 겪고 있는 실정이다. 환경부의 법정 수질 검사에 따르면 부적합 판정을 받은 곳의 대부분은 마을상수도와 소규모 급수시설인 것으로 나타났으며 초과 항목으로는 무기이온 중 특히 불소와 질산성질소 인 것으로 나타났다.[2] 이러한 문제점을 해결하고자 기존의 고도 정수처리 시설인 막여과, 오존처리, 활성탄 흡착 공정 등을[3-5] 적용하고 있으나 소규모 수도시설에 적용하기에는 유지관리, 규모, 경제적 측면 등 여러 한계점을 지니고 있다. 따라서 본 연구에서는 이러한 문제점을 해결하기 위한 방안으로 전기응집기술을 이용하여 음용수 수질기준을 초과하는 무기이온 중 불소와 질산성 질소를 제거하고자 하였다. 전기응집기술은 제거효율이 높고, 운전이 용이하며 부가적인 화학약품의 첨가가 불필요하다.[6,7] 또한 기존의 고도정수처리 기술에 비해 전기응집 공정은 처리효율과 경제적인 측면 모두를 만족시키고 있어 소규모 수도시설의 불소와 질산성질소를 효과적으로 제거할 수 있는 방안으로 판단된다. 본 연구에 사용된 실험장치는 직류전원공급장치 (DC power supply), 반응조, 전극으로 구성되어 있다. 직류전원공급장치는 최대전압 30 Volt, 최대 전류 30 Amper 까지 조절 가능하였으며 반응조의 크기는 14.5cm(w) ${\times}$ 9cm(L) ${\times}$ 22cm(H) 이고 실용적 1.5L이다. 반응조의 상부에는 전극이 고정될 수 있도록 0.5cm 간격의 홈을 만들어 제작 하였다. 전극은 가용성 전극인 알루미늄 (Al), 스테인레스스틸(SUS304)를 이용하였다. 이를 통해 전류밀도, 전극간격 등의 변수를 두어 최적의 전기응집 운전 조건을 파악하였으며 이는 소규모 수도시설의 수질개선 향상에 도움이 될 수 있을 것으로 판단된다.

  • PDF

The Separation of Particulate within PFC Decontamination Wastewater Generated by PFC Decontamination (PFC 제염 후 발생된 제염폐액 내 오염입자의 제거)

  • Kim Gye-Nam;Lee Sung-Yeol;Won Hui-Jun;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho;narayan M.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.32-39
    • /
    • 2005
  • When PFC(Perfluorocarbonate) decontamination technology is applied to removal of radioactive contaminated particulate adhered at surface during the operation of nuclear research facilities, it is necessary to develop a filtration equipment to reuse of PFC solution due to high price, also to minimize the volume of second wastewater. Contaminated characteristics of hot particulate was investigated and a filtration process was presented to remove suspended radioactive particulate from PFC decontamination wastewater generated on PFC decontamination. The range of size of hot particulate adhered at the surface of research facilities measured by SEM was $0.1{\sim}10{\mu}m$. Hot particulate of more than $2{\mu}m$ in PFC contamination wastewater was removed by first filter and then hot particulate of more than $0.2{\mu}m$ was removed by second filter. Results of filter experiments showed that filtration efficiency of PVDF(Poly vinylidene fluoride), PP(Polypropylene), Ceramic filter was $95{\sim}97\%$. A ceramic filter showed a higher filtration efficiency with a little low permeate volume. Also, a ceramic of inorganic compound could be broken easily on experiment and has a high price but was highly stable at radioactivity in comparison of PVDF and PP of a macromolecule which generate $H_2$ gas in alpha radioactivity environment.

  • PDF

Effect of Characteristic Change in Natural Graphite according to Complex Purification Process on Anode Performance for Lithium Ion Battery (복합 정제 공정에 따른 천연 흑연의 물리화학적 특성 변화가 리튬 이온 전지의 음극재 성능에 미치는 영향)

  • Ahn, Won Jun;Hwang, Jin Ung;Im, Ji Sun;Kang, Seok Chang
    • Applied Chemistry for Engineering
    • /
    • v.32 no.3
    • /
    • pp.290-298
    • /
    • 2021
  • A purification process was performed for the application of natural graphite as an anode material. The influence of the structural change and impurity content of graphite according to the process on the anode electrochemical characteristics was investigated. Natural graphite was chemically/physically purified by acid-treatment which used different amounts of solution of ammonium fluoride/sulfuric acid in the same ratio and thermal treatment used different temperatures (800~2500 ℃). Acid-treatment had limitation to remove impurities, and identified that all impurity contents was removed except some traces of atom such as Si by after progressed thermal-treatment until 2500 ℃. The anode materials characteristic of graphite treated by purification process was improved, and changes in the structure and impurity contents affected dominantly the capacity, rate property and initial Coulombic efficiency. Consequently, the complex purification process improved the graphite structure and also the performance of lithium ion battery by controlling the excessive formation of solid electrolyte interphase and expanding Li+ insertion space originated from the effective removal of impurities.