• Title/Summary/Keyword: fluorescent detection

검색결과 281건 처리시간 0.022초

Spectrofluorimetric determination of free cyanide ion with fluorescent safranine-O (형광시약 Safranine-O를 이용한 유리 시안화 이온의 분광형광법 정량)

  • Choi, Hee-Seon
    • Analytical Science and Technology
    • /
    • 제25권3호
    • /
    • pp.159-163
    • /
    • 2012
  • A spectrofluorimetric method has been developed for the determination of free $CN^-$ in real samples with fluorescent safranine-O. When safranine-O interacts electrostatistically with $CN^-$, the fluorescent intensity of safranine-O is decreased. Several experimental conditions such as pH of the sample solution and the amount of safranine-O were optimized. $Ag^+$ interfered higher than any other ions. Interference of $Ag^+$ could be disregarded because $Ag^+$ was scarcely contained or mostly complexed with $CN^-$ in selected real samples. With this proposed method, the linear range of $CN^-$ was from 5.0 to 110 ng/mL and the detection limit of $CN^-$ was 2.9 ng/mL. For validating this technique, real samples (Cu, Ag, Au electroplating wastewater, and untreated wastewater in university and in sewage treatment plant) were used. Recovery yields of 91.5%~106.0% were obtained. Based on experimental results, it is proposed that this technique can be applied to the practical determination of free $CN^-$.

Micro-LIF measurement of microchannel flow

  • Kim Kyung Chun;Yoon Sang Youl
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.65-74
    • /
    • 2004
  • Measurement of concentration distributions of suspended particles in a micro-channel is out of the most crucial necessities in the area of Lab-on-a-chip to be used for various bio-chemical applications. One most feasible way to measure the concentration field in the micro-channel is using micro-LIF(Laser Induced Fluorescence) method. However, an accurate concentration field at a given cross plane in a micro-channel has not been successfully achieved so far due to various limitations in the light illumination and fluorescence signal detection. The present study demonstrates a novel method to provide an ultra thin laser sheet beam having five(5) microns thickness by use of a micro focus laser line generator. The laser sheet beam illuminates an exact plane of concentration measurement field to increase the signal to noise ratio and considerably reduce the depth uncertainty. Nile Blue A was used as fluorescent dye for the present LIF measurement. The enhancement of the fluorescent intensity signals was performed by a solvent mixture of water $(95\%)$ and ethanol (EtOH)/methanol (MeOH) $(5\%)$ mixture. To reduce the rms errors resulted from the CCD electronic noise and other sources, an expansion of grid size was attempted from $1\times1\;to\;3\times3\;or\;5\times5$ pixel data windows and the pertinent signal-to-noise level has been noticeably increased accordingly.

  • PDF

A New Rhodamine B Hydrazide Hydrazone Derivative for Colorimetric and Fluorescent "Off-On" Recognition of Copper(II) in Aqueous Media

  • Tang, Lijun;Guo, Jiaojiao;Wang, Nannan
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권1호
    • /
    • pp.159-163
    • /
    • 2013
  • A new Rhodamine B hydrazide hydrazone 1 has been synthesized and investigated as a colorimetric and fluorescent "off-on" sensor for the recognition of $Cu^{2+}$ in $CH_3CN/H_2O$ (1:1, v/v, HEPES 10 mM, pH = 7.0) solution. Sensor 1 displayed highly selective, sensitive and rapid recognition behavior toward $Cu^{2+}$ among a range of biologically and environmentally important metal ions. Sensor 1 bind $Cu^{2+}$ via a 1:1 stoichiometry with an association constant of $1.92{\times}10^6\;M^{-1}$, and the detection limit is evaluated to be $7.96{\times}10^{-8}\;M$. The $Cu^{2+}$ recognition event is reversible and is barely interfered by other coexisting metal ions.

Determination of ${\alpha}-Keto$ Acids in Serum and Urine Using 1,2-Diamino-4,5-methylendioxybenzene as a Fluorescent Derivatizating Agent by High Performance Liquid Chromatography (HPLC법에 의한 1,2-디아미노-4,5-메틸렌디옥시벤젠을 형광유도체화제로 한 혈청 및 뇨 중의 ${\alpha}$-케토산의 분석)

  • Ok, Chi-Wan;Kim, Dae-Ki;Park, Song-Ja;Park, Jong-Sei
    • YAKHAK HOEJI
    • /
    • 제36권4호
    • /
    • pp.370-378
    • /
    • 1992
  • A simple and sensitive high performance liquid chromatographic method to quantitate ${\alpha}-keto$ acids in serum and urine was investigated. ${\alpha}-Keto$ acids react with 1,2-diamino-4,5-methylenedioxybenzene (DMB) in the presence of 2-mercapto-ethanol and sodium hydrogen sulfite to form highly fluorescent derivatives, substituted 6,7-methylenedioxyquinoxalinol. The derivatization procedure was performed in water bath at $100^{\circ}C$, and completed within 50 min. By the use of a reversed-phase column and multi-step gradient with two solvents, a mixture containing twelve of these derivatives were efficiently resolved within 35 minutes. The optimal wavelengh of the fluorescence detector are ${\lambda}_{ex}=364\;nm$ and ${\lambda}_{em}=445\;nm$. The quantitation of the individual ${\alpha}-Keto$ acids was reproducible with relative standard deviation of $3.0{\sim}7.9%$ and had a detection limits of $10{\sim}60$ fmol, except for p-hydroxyphenylpyruvic acid (960 fmol).

  • PDF

Determination of Aloesin in Plasma by High-Performance Liquid Chromatography as Fluorescent 9-Anthroyl Derivative

  • Kim, Kyeong-Ho;Lee, Jin-Gyun;Park, Jeong-Hill;Shin, Young-Geun;Lee, Seung-Ki;Cho, Tae-Hyung
    • Archives of Pharmacal Research
    • /
    • 제21권6호
    • /
    • pp.651-656
    • /
    • 1998
  • A sensitive high-performance liquid chromatographic (HPLC) method for the determination of aloesin in plasma was developed. After solid-phase extraction from plasma and derivatization of aloesin and compound AD-1, which was prepared from aloesin as a internal standard, with 9-anthroylnitrile in the presence of quinuclidine, the derivatives were separated on a Inertsil ODS-3 column using acetonitrile/methanol/water (3:1:6) as a mobile phase, and detected fluorimetrically at 460nm with excitation at 360nm. The detection limit of aloesin was 3.2ng/ml in plasma (S/N=3).

  • PDF

Detection of Near-membrane Calcium Ions in Live Tissues with a Two-Photon Fluorescent Probe

  • Shin, Yu-Na;Lim, Chang-Su;Tian, Yu Shun;Rho, Won-Young;Cho, Bong-Rae
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권3호
    • /
    • pp.599-605
    • /
    • 2010
  • A two-photon fluorescent probe (ACaCL) that can detect near-membrane $Ca^{2+}$ is reported. This probe can be excited by 780 nm fs pulses, shows high photostability and negligible toxicity, and can visualize near-membrane $Ca^{2+}$ in live cells and deep inside live tissues by two-photon microscopy.

Histological Detection of Phytoalexin Scoparone from Heat-Treated and UV-Illuminated Lemon Fruits After Inoculation with Penicillium digitatum

  • Kim, Jong-Jin;Yehoshua, Shimshon-Ben
    • The Plant Pathology Journal
    • /
    • 제17권5호
    • /
    • pp.271-275
    • /
    • 2001
  • Phytoalexin scoparone (6,7-dimethoxycoumarin) was induced in flavedo tissue of lemon fruit inoculated with Penicillium digitatum during heat treatment for 3 days at $36^{\circ}$. The compound was also induced in the flavedo tissue after UV illuminatiion. Induction of scoparone was deteected in the flavedo tissue by histological analysis. This fluorescent scoparone accumulated only on the 4-5 layers of cells adjacent to the inoculation site. Preinoculation with P. digitatum and subsequent heat-treatment induced resistance in the lemon fruit tissues after challenge-inoculation at the site of the first infection. the data obtained in the study suggest that lemon fruit acquired resistance against P. digitatum parallel with the scoparone production at the infection site.

  • PDF

Diagnosis of Viral Infection of Pensaeide (보리새우류의 바이러스 감염증의 진단)

  • 허문수;정초록;장경립
    • Journal of Life Science
    • /
    • 제9권4호
    • /
    • pp.453-459
    • /
    • 1999
  • Baculovirus(WSBV) was isolated from infected Penaeide was collected from shrimp farm at southern sea of Korea from 1993 to 1995. The Infectious virus was purified and used for diagnosis of infected shrimp. Anti-viral serum were used for immunological detection as enzyme linked immunoabsorbent assay(ELISA) and indirect fluorescent antibody technique(IFAT). In IFAT, stomach, lymphoid organ and antenae gland of infected shrimp showed fluorescent reaction. In ELISA, tissues of spontaneously infected shrimp appeared higher O.D. values than in artificial infected shrimp. Primer set was constructed from sequence of 420bp of cloned Baculovirus(WSBV) genome. Specific band for infected shrimp was detected in Polymerase chain reaction(PCR)

  • PDF

Development of Rapid Detection Method for Bacillus Anthrax and Brucella Abortus (탄저균과 부루셀라균의 신속 검출법 개발)

  • Choi, Jae-Gu
    • Journal of Environmental Health Sciences
    • /
    • 제33권5호
    • /
    • pp.434-440
    • /
    • 2007
  • The livestocks are sometimes infected with pathogenic microorganisms such as bird influenza, brucellosis, pig cholerae, and salmonella. However, it is difficult to predict the outcome of these diseases because the livestocks are mostly raised in the rural areas. Efficient systems for detecting and alerting the onset of livestock diseases are urgently required. In these studies, the fluorescent analysis method, luminescent analysis method, and frequently used gene amplification method (polymerase chain reaction) have been developed in order to detect the pathogenic microbes in the early stages of disease progression. By using these developed systems, damages due to the livestock diseases induced by microbes can be minimized. If we can detect livestock diseases in the early stage, the costs for diagnosis and treatment will be reduced, and the livestock can be quickly recovered.

Tune Metal Ion Selectivity by Changing Working Solvent: Fluorescent and Colorimetric Recognition of Cu2+ by a Known Hg2+ Selective Probe

  • Tang, Lijun;Guo, Jiaojiao;Huang, Zhenlong
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권4호
    • /
    • pp.1061-1064
    • /
    • 2013
  • A known $Hg^{2+}$ selective rhodamine B derivatised probe 1 was reinvestigated as a colorimetric and fluorescent probe for $Cu^{2+}$ through changing the applied solvent media. Probe 1 exhibited good selectivity and sensitivity to $Cu^{2+}$ in $CH_3CN-H_2O$ (7:3, v/v, HEPES 10 mM, pH 7.0) solution with a detection limit of $9.74{\times}10^{-7}$ M. The $Cu^{2+}$ sensing event was proved to be irreversible through hydrolysis of 1 to release rhodamine B.