• 제목/요약/키워드: fluorescence emission

검색결과 451건 처리시간 0.03초

Study on Argon Metastable and 4p State Neutral Atoms in Magnetized ICP and Helicon Plasmas Measured by Laser Induced Fluorescence and Plasma Emission

  • 서병훈;유신재;김정형;성대진;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.579-579
    • /
    • 2013
  • We study on Argon metastable and 4p state neutral atom density in magnetized ICP Helicon plasmas by Laser Induced Fluorescence and plasma emission. The results show that metastable density is too low at the center of chamber due to significant neutral depletion. Otherwise, 4p state is high at the center of chamber because electron density is very high. Power and pressure dependence of metastable and 4p state neutral atom have been spatially measured in the radial direction of cylindrical chamber.

  • PDF

플루오레신나트륨의 농도 범위 분석 (Analysis for Concentration Range of Fluorescein Sodium)

  • 이다애;김용재;윤기철;김광기
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권2호
    • /
    • pp.67-74
    • /
    • 2020
  • Brain tumors or gliomas are fatal cancer species with high recurrence rates due to their strong invasiveness. Therefore, the goal of surgery is complete tumor resection. However, the surgery is difficult to distinguish the border because tumors and blood vessels have the same color tone and shape. The fluorescein sodium is used as a fluorescence contrast agent for boundary separation. When the external light source is irradiated, yellow fluorescence is expressed in the tumor, which helps distinguish between blood vessels and tumor boundaries. But, the fluorescence expression of fluorescence sodium depends on the concentration of fluorescein sodium and such analytical data is insufficient. The unclear fluorescence can obscure the boundaries between blood vessels and tumors. In addition, reduce the efficiency of fluorescence sodium use. This paper proposes a protocol of concentration range for fluorescence expression conditions. Fluorescent expression was observed using a near-infrared (NIR) color camera with corresponding dilution using normal saline in 1 ml microtube. The flunoresence emission density range is 1.00 mM to 0.15 mM. The fluorescence emission begin to 1.00 mM and the 0.15 mM discolor. The discolor is difficult to fluorescence emission condition obserbation. Thus, the maximum density range of the bright fluoresecein is 0.15 mM to 0.30 mM. When the concentration range of fluorescein sodium is analyzed based on the gradient of fluorescence expression and the power measurement, the brightest fluorescence is expected to facilitate the complete resection of the tumor. For the concentration range protocol, setting concentration ranges and analyzing fluorescence expression image according to saturation and brightness to find optimal fluorescence concentration are important. Concentration range protocols for fluorescence expression conditions can be used to find optimal concentrations of substances whose expression pattern varies with concentration ranges. This study is expected to be helpful in the boundary classification and resection of brain tumors and glioma.

Nitrobenzene Functionalized Hexahomotrioxacalix[3]arene

  • Kang, Jong-Min;Cheong, Na-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권7호
    • /
    • pp.995-997
    • /
    • 2002
  • The synthesis and characterization of a nitrobenzene modified hexahomotrioxacalix[3]arene 1 are described.When calixarene 1 bound with ammonium ions carrying fluorescence group, the fluorescence of ammonium ions were effectively quenched and chang e of emission intensity provided the information of ammonium ion binding events to the calixarene 1.

Kinetics of Cl Atom Reactions. Anomaluous Fluorescence Behavior of Some Cl Atomic Transitions

  • Kwang-Yul Choo
    • Bulletin of the Korean Chemical Society
    • /
    • 제1권1호
    • /
    • pp.1-4
    • /
    • 1980
  • During the study of the kinetics of Cl atom reactions by atomic fluorescence method we observed anomalous fluorescence emission for some atomic transitions. Instead of usual decrease of the fluorescence intensity by adding substrate, 1363 A transition $(^2P^{\circ}_{3/2}{\to}^2P_{1/2})$ intensity increased by adding substrate. From the normally behaved fluorescence lines the absolute rate constant for the reaction, Cl + $CH_3Cl{\to}$, was found to be $4.2{\times}10^{-13}$ cc/molecule sec at $20^{\circ}C$.

Planar Laser-Induced Fluorescence (PLIF) Measurements of a Pulsed Electrothermal Plasma Jet

  • Kim, Jong-Uk;Kim, Youn J.;Byungyou Hong
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1808-1815
    • /
    • 2001
  • The characteristics of a pulsed plasma jet originating from an electrothermal capillary discharge have been investigate using laser-induced fluorescence (LIF) measurement. Previous emission measurements of a 3.1 kJ plasma jet show trial upstream of the Mach disk the temperature and electron number density are about 14,000 K and and 10$\^$17/ cm$\^$-3/, while downstream of the Mach dick tole values are about 25,000 K and 10$\^$18/ cm$\^$-3/, respectively. However, these values are barred on line-of-sight integrated measurements that may be misleading. Hence, LIF is being used to provide both spatially and temporally resolved measurements. Our recent work has been directed at using planar laser-induced fluorescence (PLIF) imaging of atomic copper in the plasma jet flow field. Copper is a good candidate for PLIF studies because it is present throughout the plasma and has electronic transitions that provide an excellent pump-detect strategy. Our PLIF results to date show that emission measurements may give a misleading picture of the flow field, as there appeals to be a large amount of relatively low temperature copper outside the barrel shock. which may lead to errors in temperature inferred from emission spectroscopy. In this paper, the copper LIF image is presented and at the moment, relative density of atomic copper, which is distributed in the upstream of the pulsed plasma jet, is discussed qualitatively.

  • PDF

Synthesis of a Novel Near-Infrared Fluorescent Dye: Applications for Fluorescence Imaging in Living Cells and Animals

  • Chen, Tongbin;Lai, Yijun;Huang, Suisheng
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권10호
    • /
    • pp.2937-2941
    • /
    • 2013
  • Fluorescence imaging is considered as one of the most powerful techniques for monitoring biomolecule activities in living systems. Near-infrared (NIR) light is advantageous for minimum photodamage, deep tissue penetration, and minimum background autofluorescence interference. Herein, we have developed a new NIR fluorescent dye, namely, RB-1, based on the Rhodamine B scaffold. RB-1 exhibits excellent photophysical properties including large absorption extinction coefficients, high fluorescence quantum yields, and high photostability. In particular, RB-1 displays both absorption and emission in the NIR region of the "biological window" (650-900 nm) for imaging in biological samples. RB-1 shows absorption maximum at 614 nm (500-725 nm) and emission maximum at 712 nm (650-825 nm) in ethanol, which is superior to those of traditional rhodamine B in the selected spectral region. Furthermore, applications of RB-1 for fluorescence imaging in living cells and small animals were investigated using confocal fluorescence microscopy and in vivo imaging system with a high signal-to-noise ratio (SNR = 10.1).

형광분석을 이용한 지문방식의 해수중 유기인의 분석 방법 (Development of Analytical Method of Organophosphates in Sea water by Finger Printing Fluorescence Spectroscopy)

  • 박미옥
    • 한국수산과학회지
    • /
    • 제30권3호
    • /
    • pp.377-387
    • /
    • 1997
  • 해수로 유출되고 있는 유기인제 살충, 살균제의 형광 분석법에 의한 finger print식 분석 방법을 개발하기 위해, 벼 농사에 가장 많이 사용되어지는 Hinosan과 Kitazin을 포함하는 10가지의 표준 용액을 조제하여, 형광 특성을 측정하였다. $220nm\~520nm$ 구간의 흡수 파장을 이용하여, 여기 (excitation)시켜 얻은 형광스펙트럼들을 이차원 평면 위의 형광세기 표시를 등고선 모양으로 표시하였다. 이 contour들은 각 조사된 유기인제에 대해 특징적인 형태로 관찰되었다. 조사된 10가지의 유기인제 농약의 형광 contour들은, 봉우리가 한 개로 된 DDVP를 포함한 8가지의 유기인제와 두 개의 봉우리로 나타난 Ateric을 포함한 두 가지의 유기인제 농약으로 나뉘어진다. 또한 최대 흡수파장의 영역별로 보면, 단일한 봉우리를 보이는 많은 유기인제는 약 280nm에, Ateric을 포함한 두 종류의 유기인제는 260nm에서, 그리고 장파장에서 최대 형광파장을 보여준 Monopho, Thaconyl의 최대 흡수파장은 비교적 장파장쪽으로 치우친 300nm와 340nm인, 다른 유기인제의 최대 형광파장과 서로 겹치지 않는 영역에서 나타났다. 그러나, 280nm에서 최대 흡수파장을 나타내는 유기인제 중에 Kitazin, Locsion, Meta는 약 2nm이하의 근소한 차이를 두고 최대 형광세기를 308nm주변에서 나타내었다. 이러한 그룹의 분별을 위해, HPLC-형광 자료를 이용하면 용리시간 차이에 의한 분리와 identification이 가능했다. 형광 contour가 매우 유사한 Kitazin, Locsion과 Meta를 비교하면, Kitazin은 $16\~20$분 대에 나타나는 peak들이 매우 미약할 뿐 아니라, 용리시간 9.6분에 나타난 현저한 단일 peak가 다른 형광 특성이 비슷한 유기인제인 Locsion이나 Meta와의 구분이 용이하게 해 준다. 그러나, Locsion과 Meta는 chromatogram의 용리시간이나, 세부적인 작은 peak 특징은 다르나, 그 pattern이 유사하여, 분석상 불확실성이 내재될 가능성이 있다.

  • PDF

EXCITED-STATE TWISTED INTRAMOLECLILAR CHARGE TRANSFER OF p-N,N-DIMETHYLAMINOBENZOIC ACID IN AQUEOUS CYCLODEXTRIN SOLUTIONS: TIME-RESOLVED FLUORESCENCE STUDY

  • Kim, Yong-Hee;Cho, Dae-Won;Yoon, Min-Joong
    • Journal of Photoscience
    • /
    • 제3권3호
    • /
    • pp.153-158
    • /
    • 1996
  • The effects of $\alpha$- and $\beta$-cyclodextrins (CD) on the twisted intramolecular charge transfer (TICT) behavior of p-N,N'-dimethylaminobenzoic acid (DMABA) in buffered aqueous solution have been investigated by examining formation and decay behaviors of the TICT-typical dual fluorescence. The ratio of the TICT emission to the normal emission (I$_a$/I$_b$) increases linearly $\alpha$-CD concentration increases, while in the presence of $\beta$-CD it shows nonlinear dependences on the CD concentration. The analysis of the CD-dependent changes of the I$_a$/I$_b$ and absorption spectra demonstrates formation of 1:1 inclusion complexes between DMABA and CDs. The decay time of the normal emission (ca. 700 ps) is little affected by the formation of $\alpha$-CD inclusion complex, whereas it increases upto ca. 1.6 ns upon formation of $\beta$-CD inclusion complex. The TICT emission for the $\beta$-CD inclusion complex exhibits two decay components while it shows a single component for the $\alpha$-CD inclusion complex, indicating formation of one or two types of inclusion complex in the presence of $\alpha$-CD or $\beta$-CD, respectively. These results are attributed to the CD cavity size dependence on patterns of complexation between CDs and DMABA. The CD size dependences of the TICT fluorescence properties with the orientation of the guest molecule demonstrate that the specific hydrogen bonding between the carboxylic acid group and water plays an important role in the excited-state TICT.

  • PDF

Porphyrin-Cored Arylether Dendrimers with Vinyl Groups in the Periphery

  • Lim, So-Yeon;Choi, Dae-Ock;Shin, Eun-Ju
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권7호
    • /
    • pp.1353-1358
    • /
    • 2008
  • Benzyl arylether dendrimers with zinc porphyrin core and terminal vinyl groups have been synthesized and their photophysical properties and the influence of dendritic environments were investigated. Free base porphyrin-cored benzyl arylether dendrimers 1a-1c and 3a-3c, and their zinc derivatives 2a-2c and 4a-4c have been prepared. Absorption spectra are similar for all porphyrin-cored benzyl arylether dendrimers, except that absorption intensity at 280 nm increases in the higher generation of dendrimer. Fluorescence spectra are similar with two bands for all free base porphyrin dendrimers 1a-1c and 3a-3c, although fluorescence intensity ratio of shorter wavelength emission band to longer wavelength band varies with the generation of dendrimer. Emission efficiencies of 1a-1c and 3a-3c are lower than that of TTP. Emission efficiencies of 2a-2c and 4a-4c are higher than that of ZnTTP. Absorption and emission properties of 1a-1c, 2a-2c, 3a-3c, and 4a-4c were affected negligibly with dendritic environments.

Aggregation-Induced Emission (AIE) 기반의 Turn-On 형광센서를 이용한 수질 속 중금속 납 이온의 효율적인 검출 (Efficient Detection of Heavy Metal Lead Ions in Aqueous Media using Aggregation-Induced Emission (AIE)-based Turn-on Fluorescence Sensor)

  • 최해민;성현정;차주연;이성호
    • 한국환경과학회지
    • /
    • 제32권11호
    • /
    • pp.757-765
    • /
    • 2023
  • Lead, a heavy metal widely employed in various industries, continues to pose a threat to both human health and the environment. Therefore, the development of a sensor capable of rapidly and accurately detecting lead(II) ions in real-time at contaminated sites is crucial. In this study, we have engineered a fluorescent sensor with the ability to efficiently detect lead(II) ions under actual environmental conditions, including tap water and freshwater. The compound, tetraphenylethylene carboxylic acid derivative (TPE-COOH), exhibits high selectivity and sensitivity toward lead(II) ions in aqueous solution, where the interaction between TPE-COOH and lead(II) ions leads to its aggregation, thus triggering a fluorescence "turn-on" based on the aggregation-induced emission (AIE) mechanism. Impressively, compound TPE-COOH proficiently detects lead(II) ions within a range of 30 to 100 𝜇M in tap water and freshwater, even in the presence of various interfering substances.