• Title/Summary/Keyword: fluid society

Search Result 16,447, Processing Time 0.04 seconds

Fluid Sensor and Algorithm for Trouble Detection of Solar Thermal System (태양열 시스템 고장진단을 위한 유체센서와 알고리즘)

  • Lee, Won-Chul;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.351-356
    • /
    • 2014
  • Typical trouble patterns in solar thermal systems include working fluid leakage and freezing other than breakdown of pump. A fluid sensor for measuring electric resistance of fluid was developed and installed at the top of the collector piping in order to check the fault of solar system. Working fluid level in the pipe was determined by measuring electric resistance from a fluid sensor. On the base of this, it was confirmed that the fluid sensor diagnoses leakage of fluid. Electric resistance of propylene glycol aqueous solution was measured in the range of $0{\sim}70^{\circ}C$ and 0~40% of concentration. The response surface analysis was performed by using a central composite design, and the regression equation was derived from the relationship between electric resistance, temperature, and concentration. Through the experiment in a real solar system, we can estimate a concentration of working fluid when a pump is not operating and predict a possibility of freezing. Finally, an effective algorithm for trouble shooting was proposed to operate and maintain the solar system.

Analysis of the Macroscopic Traffic Flow Changes using the Two-Fluid Model by the Improvements of the Traffic Signal Control System (Two-Fluid Model을 이용한 교통신호제어시스템 개선에 따른 거시적 교통류 변화 분석)

  • Jeong, Yeong-Je;Kim, Yeong-Chan;Kim, Dae-Ho
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.1
    • /
    • pp.27-34
    • /
    • 2009
  • The operational effect of traffic signal control improvement was evaluated using the Two-Fluid Model. The parameters engaged in the Two-Fluid Model becomes food indicators to measure the quality of traffic flow due to the improvement of traffic signal operation. A series of experiment were conduced for the 31 signalized intersections in Uijeongbu City. To estimate the parameters in the Two-Fluid Model the trajectory informations of individual vehicles were collected using the CORSIM and Run Time Extension. The test results showed 35 percent decrease of average minimum trip time per unit distance. One of the parameters in the Two-Fluid Model is a measure of the resistance of the network to the degraded operation with the increased demand. The test result showed 28 percent decrease of this parameter. In spite of the simulation results of the arterial flow, it was concluded that the Two-Fluid Model is useful tool to evaluate the improvement of the traffic signal control system from the macroscopic aspect.

The Study on Pressure Oscillation and Heat Transfer Characteristics of Oscillating Capillary Tube Heat Pipe Using Mixed Working Fluid (혼합 작동 유체를 이용한 진동 세관형 히트 파이프의 압력 진동과 열전달 특성에 관한 연구)

  • Jeong, Hyeon-Seok;Kim, Jeong-Hun;Kim, Ju-Won;Kim, Jong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.318-327
    • /
    • 2002
  • In this paper, heat transfer and pressure oscillation characteristics on oscillating capillary tube heat pipe(OCHP) according to input heat flux, mixture ratio of working fluid and inclination angle were investigated and were compared single working fluid(R-142b) with binary mixture working fluid(R-142b-Ethano1). OCHP was made to serpentine structure of loop type with 10 turns by drilling the channels of length 220mm, width 1.5mm, and depth 1.5mm on the surface of brass plate. In this study, R-l42b and R-l42b-Ethanol were used as working fluids, the charging ratio of working fluids was 40(vol.%), the input heat flux to evaporating section was changed from 0.3W/㎠ to 1.8W/㎠, and mixture ratio of working fluid was R(100%), R(95%)-E(5%), R(90%)-E(10%), and R(85%)-E(15%). From the experimental results, it was found that the effective thermal conductivity of single working fluid was better than that of binary mixture working fluid. But, in case of binary mixture working fluid, critical heat flux was higher than that of single working fluid. And, the higher the mixture ratios of working fluid, the lower heat transfer performance. In case of pressure oscillation, as the inclination angle was lower, pressure wave was more irregular. These phenomena were more serious when the working fluid was binary mixture. Besides, when mixture ratio was higher, saturated pressure was increased, more irregular wave was observed and the mean amplitude was increased. For the same input heat flux, inclination angle and charging ratio, when pressure oscillation has sinusoidal wave, mean amplitude was small, and saturated pressure was low value, the heat transfer was excellent.

Acoustic Interface Element on Nonconformal Finite Element Mesh for Fluid-Structure Interaction Problem (비적합 유한요소망에 적용가능한 유체-구조물 연결 요소)

  • Cho, Jeong-Rae;Lee, Jin Ho;Cho, Keunhee;Yoon, Hyejin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.163-170
    • /
    • 2023
  • In the fluid-structure interaction analysis, the finite element formulation is performed for the wave equation for dynamic fluid pressure, and the dynamic pressure is defined as a degree of freedom at the fluid nodes. Therefore, to connect the fluid to the structure, it is necessary to connect the degree of freedom of fluid dynamic pressure and the degree of freedom of structure displacement through an interface element derived from the relationship between dynamic pressure and displacement. The previously proposed fluid-structure interface elements use conformal finite element meshes in which the fluid and structure match. However, it is challenging to construct conformal meshes when complex models, such as water purification plants and wastewater treatment facilities, are models. Therefore, to increase modeling convenience, a method is required to model the fluid and structure domains by independent finite element meshes and then connect them. In this study, two fluid-structure interface elements, one based on constraints and the other based on the integration of nonsmooth functions, are proposed in nonconformal finite element meshes for structures and fluids, and their accuracy is verified.

Ultrasonic Characterization of Fluid Mud: Effect of Temperature (부유퇴적물의 초음파 특징: 온도의 효과)

  • Kim, Gil-Young;Kim, Dae-Choul;Kim, Jeong-Chang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.4E
    • /
    • pp.140-145
    • /
    • 2004
  • A laboratory study was carried out to investigate the change of ultrasonic velocity as a function of temperature for fluid mud (i.e., suspension). Pulse transmission technique with ultrasonic wave was used for ultrasonic velocity measurement. The five samples for fluid mud were prepared for concentration range of $30.6{\%}\;(1.24\;g/cm^{3}\;in\;density),\;23.3{\%}\;(1.19\;g/cm^{3}),\;11.5{\%}(1.10\;g/cm^{3}),\;7.8{\%}\;(1.08\;g/cm^{3}),\;and\;3.8{\%}\;(1.05\;g/cm^{3})$ by weight. The ultrasonic velocity in fluid mud was investigated to increase $(approximately\;2.83\;to\;4.95\;m/s/^{\circ}C)$ with increasing temperature, due to the effect of viscosity and compressibility of water with changing temperature. But the increasing rate tends to decrease at temperature higher than $30^{\circ}C,$ caused by the effect of viscosity. The concentration of fluid mud more affect to the ultrasonic velocity at higher temperature range than that at lower temperature. Overall the temperature effect on the ultrasonic velocity in fluid mud was a similar rate as for distilled water and seawater, suggesting fluid mud significantly depends on the behavior of water.

A Study on the Effect of Machining Precision and Shop Floor Environment due to Cutting Fluid Usage (절삭유 사용이 가공정밀도 및 작업환경에 미치는 영향에 관한 연구)

  • Hwang, Joon;Chung, Eui-Sik;Heo, Sung-Jung
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.1004-1007
    • /
    • 2001
  • This paper presents the experimental results to verify the environmental consciousness with economic balances due to cutting fluid behaviors, effectiveness in machining process. Even though cutting fluid improves the machined part quality through the cooling and lubracating effects, its environmental impact is also increased according to the cutting fluid usage. Because cutting fluid are used by experience than science on shop floors, its environmental impact are more serious to human health hazard, shop floor environments. In this study a few cutting parameters are adopted as the machinability index (i.e. ; tool wear and surface roughness), and aerosol mist diffusion rate of cutting fluid as the environment consciousness index. These indeces are analyzed quantitatively via a few experiements. The results of this study can be facilitate the optimization of cutting fluid usage in achieving a balanced environmental consciousness consideration with economic view.

  • PDF

Development of an Injection Nozzle and an Electromagnet Module for a MR Fluid Jet Polishing System (MR Fluid Jet Polishing 시스템을 위한 분사노즐 및 전자석 모듈 개발)

  • Lee, Jung-Won;Cho, Yong-Kyu;Ha, Seok-Jae;Shin, Bong-Cheol;Cho, Myeong-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.767-772
    • /
    • 2012
  • Generally, abrasive fluid jet polishing system has been used for polishing of complex shape or freeform surface which has steep local slopes. In the system, abrasive fluid jet is injected through a nozzle at high pressure; however, it is inevitable to lose its coherence as the jet exits a nozzle. This problem causes incorrect polishing results because of unstable and unpredictable workpiece material removal at the impact zone. In order to solve this problem, MR fluid jet polishing method has been developed using a mixture of abrasive and MR fluid which can maintain highly collimated and coherent jet by applied magnetic field. Thus, in this study, an injection nozzle and an electromagnetic module, most important parts in the MR polishing system, were designed and verified by magnetic field and flow analysis. As the results of experiments, it can be confirmed that stable fluid jets for polishing were generated since smooth W-shapes and uniform spot size were observed regardless of standoff distance changes.

Machining Performance of Optical Glass with Magnetorheological Fluid Jet Polishing (MR 유체 제트 연마를 이용한 광학유리의 가공성능)

  • Kim, Won-Woo;Kim, Wook-Bae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.8
    • /
    • pp.929-935
    • /
    • 2011
  • As a deterministic finishing process for the optical parts having complex surface, machining performance of the magnetorheological(MR) fluid jet polishing of optical glass are studied and compared with a general water jet polishing. First, design of the jet polishing system which has the special electromagnet-nozzle unit for stabilizing the slurry jet based on MR fluid and the change of jet shape as magnetic field is applied are explained. Second, for the BK7 glass, machining spot and its cross section profile are analyzed and the unique effect of MR fluid jet polishing is shown. Third, both material removal depth and surface roughness are explored in order to investigate the polishing performance of MR fluid jet. With the same ceria abrasives and amount in the polishing slurries, MR fluid jet shows superior machining performance compared to water jet and the difference of material removal mechanism and its resulting performance are described.

The Role of Synovial Fluid in the Micro-scale Frictional Response of Bovine Articular Cartilage from Atomic Force Microscopy (원자힘 현미경을 이용한 활액이 소 연골의 미세 마찰특성에 작용하는 역할)

  • Park, Seong-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.11
    • /
    • pp.119-125
    • /
    • 2008
  • The objective of this study was to compare micro-scale friction coefficients with and without synovial fluid, and micro-scale measurements were performed using atomic force microscopy (AFM) with a $5{\mu}m$ spherical probe. Four cylindrical cartilage specimens were harvested from two fresh bovine humeral heads (4-6 months old). $Average{\pm}standard$ deviation values of the micro-scale AFM frictional coefficients calculated from the liner fit of friction versus normal force was $0.177{\pm}0.012$ and $0.130{\pm}0.010$ with and without synovial fluid coating on AFM probe respectively, showing its reduction by ${\sim}27%$ with synovial fluid. To the best of our knowledge, this experimental study investigates the first such comparisons of frictional response of articular cartilage with and without synovial fluid coating on AFM probe, and provides significant insights into the role of synovial fluid in the articular cartilage friction and lubrication independently of the confounding effect of fluid pressurization in the articular cartilage.

The Dynamic Characteristics of Rotating Cantilever Pipe Conveying Fluid (회전하는 유체이송 외팔 파이프의 동특성 해석)

  • 윤한익;손인수
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.1
    • /
    • pp.26-32
    • /
    • 2003
  • The vibrational system of this study is consisted of a rotating cantilever pipe and the flow in the pipe. The equation of motion is derived by using Lagrange equation. The influences of the rotating angular velocity and the velocities of fluid flow in the pipe have been studied on the dynamic characteristics of a rotating cantilever pipe by numerical method. The tip-amplitude of axial vibration and maximum tip-deflection of axial direction of cantilever pipe are directly proportional to the velocity of fluid and rotating angular velocity of pipe In the steady state. respectively The bending tip-amplitude of cantilever pipe is inversely proportional to the velocity of fluid in the steady state. When the rotating angular velocity is 5 rad/s, the velocity of fluid increase with increasing the natural frequency of axial vibration at second mode and third mode, but the natural frequency axial direction of first mode is decreased. The natural frequency of lateral direction is decreased due to increase of the rotating angular velocity. It identifies that the Influence of velocity of fluid give much variation lower mode of vibration in lateral direction. And the Influence of velocity of fluid give much variation higher mode of vibration in axial direction.