• Title/Summary/Keyword: fluid slip

Search Result 150, Processing Time 0.039 seconds

A Pilot Study on Environmental Factors Contributing to Childhood Home Slip-Down Injuries (가정 내 낙상으로 인한 아동 손상의 유발 환경 인자에 관한 예비연구)

  • Ryu, Jeong-Min;Seo, Min Hoo;Kim, Won-Young;Kim, Won;Lim, Kyoung-Soo
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate environmental factors contributing to childhood home slip-down injuries. Methods: Among a total of 2,812 injured children in our Customer Injury Surveillance System (CISS), we performed a prospective study on 262 children with home slip-down injuries who visited the pediatric emergency department of Asan Medical Center between March 2008 and February 2009. We made a frequency analysis on parameters such as activities just before the accident, the presence of any obstacles or lubricant materials, specific home place in the home where the injuries occurred, flooring materials on which the slip-down happened, additional objects hit after slip down, the site and kind of injury, the duration of therapy, and the disposition. Results: Walking was the most common activity just before the injury. Because rooms and bathrooms were most common places in the home for slip down injuries, laminated papers/ vinyl floor coverings and tiles were the most common flooring materials used in the places where the injuries occured. Most commonly, no obstacles caused the children to slip down, but the furniture, stairs, doorsills, wetness, or soapy fluid followed after that. Over half of the children who slipped (58%) also collided with other than the floor itself after the slip-down, most common objects hit were the edges of the furniture, and doorsills, followed by stairways. The head and neck were the most commonly injured sites, and a laceration was the most common kind of injury. Most children needed less than 1 week of therapy, only 4 children (1.53%) admitted. There were no mortalities. Conclusion: The environmental factors contributing to slip-down injuries were the bathroom, laminated papers/vinyl floors, the furniture, stairs, doorsills, and wetness or soapy fluid. Especially, the furniture, stairs, and doorsills can be both primary obstacles and secondary collision objects. For the safety of our children, we must consider these factors on housing, when decorating or remodeling our house.

Autonomous Vehicle Driving Control Considering Tire Slip and Steering Actuator Performance (타이어 슬립과 조향작동장치의 성능을 고려한 무인자동차 자율주행 제어)

  • Park, C.H.;Gwak, G.S.;Jeong, H.U.;Hong, D.U.;Hwang, S.H.
    • Journal of Drive and Control
    • /
    • v.12 no.3
    • /
    • pp.36-43
    • /
    • 2015
  • An autonomous vehicle control algorithm based on Ackerman Geometry is known to be reliable in low tire slip situation. However, vehicles at high speed make lateral errors due to high tire slip. In this paper, considering the tire slip of vehicles, the steering angle is determined based on the Ackerman Geometry and is supplemented tire slip angle by the Stanley steering algorithm. In addition, to prevent the tire slip, the algorithm, which restricts steering if a certain level of slip occurs, is used to reduce the lateral error. While many studies have been extended to include vehicle slip, studies also need to be carried out on the tire slip depending on hardware performance. The control algorithm of autonomous vehicles is compensated considering the sensor noise and the performance of steering actuator. Through the various simulations, it was found that the performance of steering actuator was the key factor affecting the performance of autonomous driving. Also, it was verified that the usefulness of steering algorithm considering the tire slip and performance of steering actuator.

Development of Wall Slip Models for Rarefied Gas and MEMS Thermal Fluid Flows (희박기체 및 MEMS 열유동장 해석을 위한 벽면 슬립모델 개발)

  • Myong, Rho-Shin;Cho, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.7
    • /
    • pp.90-97
    • /
    • 2002
  • Wall slip models are essential to the study of nonequilibrium gas transport in rarefied and microscale condition that can be found in gas flows associated with aerospace vehicle, propulsion system, and MEMS. The Maxwell slip model has been used for this type of problem, but it has difficulty in defining the so-called accommodation coefficient and has not been very effective in numerical implementation. In the present study, on the basis of Langmuir's theory of the adsorption of gases on metals, a physical slip model is developed. The concept of the accommodation coefficient and the difference of gas particles are clearly explained in the new model. It turned out that the Langmuir model recovers the Maxwell model in the first-order approximation. The new models are also applied to various situations including internal flow in a microchannel. Issues of validation of models are treated by comparing analytic results with experiment.

A study on low-noise and high-efficiency sirocco fan development (저소음 고효율 시로코 팬 개발에 관한 연구)

  • Park, K.J.;Lee, S.H.;Son, B.J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.02a
    • /
    • pp.63-72
    • /
    • 1998
  • This study Is on the performance prediction and design of sirocco fan. Slip coefficient is very important factor for the performance analysis of centrifugal-type fan. Because generally used slip coefficient equations of backward curved centrifugal fan are not appropriate for forward curved sirocco fan, in this study a proper slip coefficient equation for sirocco fan is suggested. Using this equation performance prediction program for sirocco fan is composed and also included the total noise prediction that include turbulent noise at the fan Inlet and boundary layer noise. A comparison between the values obtained from performance prediction program and experimental values shows that the program predicts the sirocco fan performance in a practical rate.

  • PDF

${\mu}-PIV$ Visualization of Flow in Hydrophilic and Hydrophobic Micro-nozzle (친수성 및 소수성 마이크로 노즐 내 유동 ${\mu}-PIV$ 연구)

  • Byun, Do-Young;Kim, Ji-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.15-18
    • /
    • 2006
  • Recently, experimental visualization of microscale fluid transport has attacted considerable attention in designing microelectromechanical systems. Fluid-surface interactions on hydrophobic and hydrophilic surfaces can play a key role in passively controlling microfluidics. Here we investigate the slip boundary condition depending on the surface characteristics; hydrophilic, hydrophobic wettabilities. Using the micro-PIV, velocity profiles are measured in the glass (hydrophilic), PDMS (hydrophobic) microchannels.

  • PDF

Design Method of the Sirocco Fan Considering Aeroacoustic Performance Characteristics (공력음향학적 특성을 고려한 시로코 팬의 설계 방법)

  • Lee, Chan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.2
    • /
    • pp.59-64
    • /
    • 2010
  • A design method of Sirocco fan is developed for constructing 3-D impeller and scroll geometries, and for predicting both the aerodynamic performance and the noise characteristics of the designed fan. The aerodynamic blading design of fan is conducted by blade angle, camber line determinations and airfoil thickness distribution, and then the scroll geometry of fan is designed by using logarithmic spiral. The aerodynamic performance of designed fan is predicted by the meanline analysis with flow blockage, slip and pressure loss correlations. Based on the predicted performance data, fan noise is predicted by two models for cutoff frequency and broadband noise sources. The present predictions for the performance and the noise level of actual fans are well agreed with measurement results.

HALL EFFECTS ON HYDROMAGNETIC NATURAL CONVECTION FLOW IN A VERTICAL MICRO-POROUS-CHANNEL WITH INJECTION/SUCTION

  • BHASKAR, P.;VENKATESWARLU, M.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.24 no.1
    • /
    • pp.103-119
    • /
    • 2020
  • In this work, the hydromagnetic and thermal characteristics of natural convection flow in a vertical parallel plate micro-porous-channel with suction/injection is analytically studied in the presence of Hall current by taking the temperature jump and the velocity slip at the wall into account. The governing equations, exhibiting the physics of the flow formation are displayed and the exact analytical solutions have been obtained for momentum and energy equations under relevant boundary conditions. The impact of distinct admissible parameters such as Hartmann number, Hall current parameter, permeability parameter, suction/injection parameter, fluid wall interaction parameter, Knudsen number and wall-ambient temperature ratio on the flow formation is discussed with the aid of line graphs. In particular, as rarefaction parameter on the micro-porous-channel surfaces increases, the fluid velocity increases and the volume flow rate decreases for injection/suction.

A Study on Vortex Pair Interaction with Fluid Free Surface

  • Kim, K.H.;Kim, S.W.
    • Journal of ILASS-Korea
    • /
    • v.10 no.4
    • /
    • pp.26-31
    • /
    • 2005
  • Today, the research to examine a fact that interaction between the air and the fluid free surface affects the steady state flow and air. We proved the interaction between vortex pairs and free surface on each condition that is created by the end of delta wings. Another purpose of this study is to investigate the effect of surface active material which call change the surface tension and we must consider when we refer to turbulent flow on surface tension. Therefore, this research examined the growth process of vortex pairs on condition of clean, contaminated free surface and wall after we made vortex pairs through counter rotating flaps. The results of this study suggest that vortex pairs in clean free surface rise safely but the vortex pairs in contaminated free surface and rigid, no slip is made secondary vortex or rebounding. However the secondary vortex in rigid, no slip is stronger than before. and we can find the vortex shape which roll up more completely. However, these will disappear by the effect of wall.

  • PDF